Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹19.7 Cr
EMD Value
₹11.3 L
Closing Date
24 Feb 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Yes (up to 2 members)
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
WORKS
13 conditions · 2 needing a document upload
The Tender Cost is more than 50 Lakhs, hence eligibility criteria is applicable. The firm has to be submit the Annexure VIB as per GCC 2022 along with relevant documents duly signed by CA. Terms and conditions are as per GCC 2022.
The Tender Cost is more than 50 Lakhs, hence eligibility criteria is applicable. The Similar Type of work, Work of supply, installation & commissioning of DAC OR any signaling work involving supply, installation & commissioning of DAC.
2 conditions
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The consignee of the tender is SSE(SIG)Warora PVC clause is not applicable. The maintenance period is 12 months from actual date of completion.
Provision of Digital Axle counters in vulnerable location like water log, coal mud and muck track circuits for enhanced safety and efficiency between Nagri-Tadali section of Nagpur Division
16-2026-SNT-NGI-TAE-DAC
16-2026-SNT-NGI-TAE-DAC
Open
Works - General
11 Months
Nagpur, Maharashtra
₹0
₹11.3 L
24 Feb 2026
30 Jan 2026
258 items across 4 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 16,58,83,549.69 | ||
| — | 4.00 | — | — | ||
| Supply of Relay rack assembly complete with scaffolding, fixtures and accessories including MS Bars for fixing of relay plug board, string rods, fuse strips with bracket, 11 way Bus bars with cover and mounting brackets, runway for cable/wires, frame, base assembly etc. Siemens type & as per extant practice on C.Rly. Typical part list as per Annexure-II and Rack arrangement as per sketch no SK-727 and Rack plan as approved by Engineer in charge. | — | — | — | 1,43,134 | |
| — | 2.00 | — | — | ||
| Supply of Main cable Termination rack complete with scaffolding, fixtures & accessories including square bars for mounting 8-way terminal blocks, ladder, string rods, frame, base assembly, insulators, J bolt , nut/bolts & fasteners, backelite sheet, etc. Siemens type and as per extant practice of Central Railway. Typical part list as per Annexure-III and rack arrangement shall be as per sketch No.SK-727 with latest alterations. | — | — | — | 61,374.16 | |
| — | 1.20 | — | — | ||
| Supply of PVC Indoor cable 1x60x0.6mm dia color coding of insulation of inner core shall be in six color viz Blue, Red, Grey, Green,Brown & Black conforming to IRS 76/89 (Amd.3) or latest. | — | — | — | 3,68,768.88 | |
| — | 1.20 | — | — | ||
| Supply of PVC Indoor cable 1x40x0.6mm dia color coding of insulation of inner core shall be in eight color viz Blue, Red, Grey, Green, Brown, Black, Yellow & White conforming to IRS 76/89 (Amd.3) or latest. | — | — | — | 2,41,920.77 | |
| — | 1.20 | — | — | ||
| Supply of PVC flexible copper cable single core, multistrand 1x10 Sq.mm (80 conductor each diameter 0.40 +/- 0.01) as per IS 694/2010. with latest amendment if any with insulation thickness of 1.0 mm nominal conductor resistance 1.91 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3)or latest. | — | — | — | 1,68,818.35 | |
| — | 1.20 | — | — | ||
| Supply of PVC flexible copper cable single core, multistrand 1x16 Sq.mm (126 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS: 694/2010. with latest amendment if any with insulation thickness of 1.0mm nominal conductor resistance 1.121 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3)or latest. | — | — | — | 2,50,790.59 | |
| — | 6.00 | — | — | ||
| Supply of wire 16/0.2 (Blue, Red, Grey, yellow, Brown, Black, White as per site engineer instruction) finolex/polycab/delton make. IRS:S-76/89 (Amd.3), BS: 4808 Part-2. Wire to be procured from RDSO approved vender. | — | — | — | 39,683.4 | |
| — | 24.00 | — | — | ||
| Supply, installation, wiring, testing & commissioning of Microcontroller based Power Supply Autochangeover device complete along with accessories using Contractor's own wiring & fixing material as per following configuration- (i) Power Supply - AC/DC. (ii) Voltage 24V to 150V. (iii) Current Up to - 45Amp. Note: The work shall be done as per instructions of Railway's Engineer in- charge | — | — | — | 8,85,679.68 | |
| — | 300.00 | — | — | ||
| Supply of cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4, SA- 23749 & Spec No.IRS S 75/2006 Rev.02 with latest amendment. Fuse block shall be suitable for round head type voltage fuses. | — | — | — | 50,976 | |
| — | 30.00 | — | — | ||
| Supply of QBAT track Relay, AC immunized, 2F-2B, contacts, 9 ohms. Complete with plug, board, retaining clip and connectors as per RDSO/SPN/84 Ver. 2.0 with Amendment No.1 or latest. | — | — | — | 1,95,797.4 | |
| — | 30.00 | — | — | ||
| Supply of QNA1K relay 1000 ohm, 6F/6B 24V DC as per BRS :931A, IRS:S60, IRSS354 & IRS:S23 and RDSO Spec. STS/E/Relays/UEA (PI) dtd.30.05.1997 Annexure II (IRS:S60/78 with Amendment no.1 , IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1) | — | — | — | 1,20,891 | |
| — | 60.00 | — | — | ||
| Supply of Relay & plug board QN1 / 50V/ 8F-8B Metal to carbon DC neutral- BRS:930,IRS:S60/78 with Amendment no.1 , IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1 | — | — | — | 3,18,883.2 | |
| — | 12.00 | — | — | ||
| Supply of Automatic media changeover of Modems working on redundant channels for data transmission on OFC/Quad/Micowave Radio. | — | — | — | 4,25,139.84 | |
| — | 12.00 | — | — | ||
| Supply of MODEM compatible with existing UFSBI system to work on back up media (either VF channel on OFC P/Mux or 2 Mbps E1 channel from STM or direct dark single mode optic fibre cable upto 30 km distance. | — | — | — | 8,72,949.84 | |
| — | 12.00 | — | — | ||
| Resin cored wire as per specification No.IS:1921-1975 with Alloying element percentage as 63% SN (Tin) nd / 37% Pb (Lead) with percentage of various impurities not exceeding the values Sb (Antimony 0.2% maximum, Cu (Copper) 0.1% maximum, As (Arsenic) 0.05% maximum, Fe (Iron) 0.02% maximum & other impurities mainly AI, Zn & Cd shall be limited. The flux shall be free from corrosive action as per clause 5.2 & flux percentage may be used as per requirement. | — | — | — | 15,264.48 | |
| — | 120.00 | — | — | ||
| Lacing thread rolls, black, wax coated (100 mtrs) | — | — | — | 8,071.2 | |
| — | 24.00 | — | — | ||
| Design, fabrication and supply of fuse Auto changeover system for 32 Nos external non detorating type fuses or 'G' type fuses from 0.6A Amp to 4A Amp capacities used in signaling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. As per RDSO spec. RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any. | — | — | — | 6,55,523.04 | |
| — | 72.00 | — | — | ||
| Supply of Hand Cuff Locks / Godrej Navtal lock with Three common keys. | — | — | — | 20,815.2 | |
| — | 1200.00 | — | — | ||
| Supply of round head type non detoriating type low voltage cartridge fuse as per specn No. IRS/S/78/92 with latest amendments - 2A/4A/6A capacity | — | — | — | 87,792 | |
| — | 60.00 | — | — | ||
| Supply of Apparatus case with godown locks with detachable handle on both the doors.a) Single Case as per Drg No SK 783-1 & 2. with latest alteration. | — | — | — | 10,09,041.6 | |
| — | 12.00 | — | — | ||
| Supply of Apparatus case with godown locks with detachable handle on both the doors. b)Half Case as per Drg No SK 783-1 & 2. with latest alteration. | — | — | — | 1,59,823.92 | |
| — | 72.00 | — | — | ||
| Supply of earth electrode assembly as per Drg.No.CR/S&T/SK-815 | — | — | — | 80,796.96 | |
| — | 72.00 | — | — | ||
| Maintenance Free Earth as per RDSO/SPN/197/2008 or latest consisting of : 1) Copper bond steel electrode 3 Mtr long 17mm dia with copper bonding thickness of min. 250micron & UL listed & marked-01 No. (2) Earth enhancement compound RDSO Approved in sealed bag of 10 kgs - 03 No. (3) Copper strip 150 x 25 x 6mm - 02 No (4) Copper Strip 300 x 25 x 6mm- 01 No (5) 35 Sqmm Copper Cable to connect earth electrode to MEEB - 15Mtr Approx. | — | — | — | 13,31,408.16 | |
| — | 600.00 | — | — | ||
| Supply of 35 Sq. mm. multistrand single core PVC insulated copper for connecting earth bus bar to earth electrode. | — | — | — | 2,58,420 | |
| — | 4000.00 | — | — | ||
| Supply of Channel Pins single groove, galvanised, 7 mm suitable for 4mm dia bonding wire as per spec No. IRS: S 17-75 Revision 3. | — | — | — | 9,440 | |
| — | 429.00 | — | — | ||
| Supply of Digital Axle counter Multi section type complete system including the central Evaluator and final track clearance relay for each section, Reset boxes, LV boxes, All track side units with detection point complete assembly & fixing arrangement for each detection point, clamps deflector for either side of each detection points, monitoring console for monitoring all the DPs at a time installed at a station/RH/IBH etc. with all other accessories fully wired and fully equipped as per RDSO specification No.RDSO/SPN/176/2013 (ver.3) or latest and manufacturers specification. The equipment must also include the following: a) System must have remote monitoring and health diagnostics feature as per RDSO specification. b) Surge protection device, c) 20% spare slots for the both detection heads and track section in the evaluator for future and emergency provision. Each set also consisting of a) Double rail contact of standard length of cable as per site requirement and mounting accessories - Equal to no. of DP. b) Deflectors to safe guard Rail contact will be TWICE the no. of DPs. c) Protecting tube from DP to railhead as per requirement. d) Diagnostic PC as per specification and other accessories (as per Annexure-VI) e) Pre-wired cabinet/rack - No. as per site requirement. f) 6 nos. Electrostatic Discharge Wrist Band for cards/modules protection. | — | — | — | 14,59,76,636.52 | |
| — | 401.00 | — | — | ||
| SUPPLY of Electronic timers for DAC reset arrangement 3 sec to 30 sec with 2NO/2NC contact working voltage 24V/60V DC. Siemens/ABB/L&T or SELEC(642X A programmable electronic timer switch) make. | — | — | — | 11,29,480.66 | |
| — | 6.00 | — | — | ||
| Supply of Multi strand twin twisted core shielded cable of 28 - 30/0.2 mm for Axle counter as per IRS spec. 76/89 with Amendment No.03 or latest amendments, if any. Unit(1 Set= Per 100 meters) | — | — | — | 89,250.48 | |
| — | 18000.00 | — | — | ||
| Supply of RCC pipes half round of size 300 mm dia outer and 250 mm dia internal 1 mtr long matching to IS No.458/2003 amendment-1 with Rev.4. | — | — | — | 77,52,600 | |
| — | 6000.00 | — | — | ||
| Supply of modular terminal block of 2.5 sq. mm 2 IN 2 OUT type disconnect type terminal along with as per RDSO SPN/189/2004 Rev 3.0. The current capacity of 16 Amps and more. The terminal should have marking at centre to view description from front. Material to be procured from RDSO approved firms only. | — | — | — | 7,08,000 | |
| — | 71.00 | — | — | ||
| Supply of DIN Channel for the terminals 1 Mtrs each | — | — | — | 15,666.86 | |
| — | 497.00 | — | — | ||
| Supply of End plates for modular terminal block | — | — | — | 11,729.2 | |
| — | 568.00 | — | — | ||
| Supply of End Clamp for modular terminal block | — | — | — | 10,053.6 | |
| — | 71.00 | — | — | ||
| Supply of Marker Card as per customer spec (10x10) | — | — | — | 5,948.38 | |
| — | 12.00 | — | — | ||
| Operating tool (operating tool, screw driver & stripper) as per Annexure-VII. | — | — | — | 1,02,886.56 | |
| — | 6.00 | — | — | ||
| Supply of Digital measuring wheel for measuring cable trench/route make: Stanley or Freemens make or similar reputed make. | — | — | — | 27,300.48 | |
| — | 300.00 | — | — | ||
| Supply of Paints as per relevant IS specification preferably Asian / Apcolite/ Dulux make in different colour in one kg/2 kg pack | — | — | — | 1,08,324 | |
| — | 180.00 | — | — | ||
| — | — | — | 5,83,675.2 | ||
| — | 6.00 | — | — | ||
| Suply, Installation, Testing & Commissioning of Aspiration (Air Sampling Type) Detection unit complying to RDSO/SPN/217/2025 Ver 3.1 or latest. As per latest VDS approved/Listed. | — | — | — | 15,76,829.28 | |
| — | — | — | 2,17,73,778.9 | ||
| — | 18.00 | — | — | ||
| Installation of Relay Rack Assembly including IDF pillars if any complete with wall supports, scaffolding, ladders, runway for cables, Relay/Relay group base plates, fixing of Tag blocks etc. The work shall be done as per approved plan, extant practice on C.Railways & the instructions of Rly engineer at site. | — | — | — | 26,719.92 | |
| — | 6.00 | — | — | ||
| Installation of Cable Termination Rack Assembly complete including wall supports, scaffolding, Disconnecting links/ARA terminal, 96 way tag block with tag block cover & other necessary accessories etc. The work shall be done as per approved plan, extant practice on C.Railways & the instructions of Rly engineer at site. | — | — | — | 7,249.92 | |
| — | 6.00 | — | — | ||
| Installation of LT Power panel/power distribution panel/Auto Changeover Panel, power supply equipmnts such as Rectifiers Transformers, Battery chargers etc., mounting of program switches on bakelite sheet of size 300 mm x 300 mm x 8 mm fitted to MS angle (size 25mm x 25mm x 5mm) brackets, wiring as per requirements. Necessary wires to be supplied by Rlys, lugs & glands to be supplied by contractor. | — | — | — | 1,47,037.44 | |
| — | 80.00 | — | — | ||
| Fixing of Q series relay base plate/metal to metal relay mini group and major group base plate, laying, bunching, lacing, dressing & packeting of 60/40 core PVC indoor cable/flexible wire and termination 60/40 core cable/flexible wire on tagblock/base plate & base plates & soldering. This includes fuse wiring, bus bar looping etc. required for keeping installation ready for circuit wiring work & panel throughing work. The work shall be done as per approved plan, extant practice on C.Rly & the instruction of Rly. Engineer at site. Unit(Per Tag Block=1 set) | — | — | — | 48,899.2 | |
| — | 12.00 | — | — | ||
| Installation, testing and commissioning of Automatic Media Changeover of modems working on redundant channels for data transmission on OFC / Quad (Unit - one pair Qty 1 set) | — | — | — | 3,17,608.8 | |
| — | 24.00 | — | — | ||
| Wiring, fixing & commissioning of modules of fuse 0.6 to 4 Amp rating alarm system having change over arrangement and potential free contact wiring at Datalogger IDF. Etc as per instructions of Railway Engineer. (Module of 32 nos fuses) | — | — | — | 15,207.84 | |
| — | 18.00 | — | — | ||
| Lettering & Numbering of detail and description writing of particulars of terminations & equipmlents on relay rack, relays, cable termination rack, battery & power equipment, IPS, operating panel, axle counter etc constituting entire system with contractor's own paint and writing material ("Asian/Dulux" make enamel paints to be used). The work shall be done as per extant practice on C.Rly & instruction of Rly engineer at site. | — | — | — | 6,159.6 | |
| — | 6.00 | — | — | ||
| Excavation and Casting of main signal foundation as per Drg No SK 801 with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for casting of foundation will have to be brought by the contractor at his own cost. | — | — | — | 53,361.96 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
16-2026-SNT-NGI-TAE-DACTD_compressed.pdf
InspectionAgency.pdf
DPPlan.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .