Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 LAccepted-AOC AB 253 SALT LAKE KOLKATA 700064 | KOLKATA | KOLKATA | WEST BENGAL | 700064 | L1 | Accepted-AOC L1 | |
| 2 | L2₹4.1 L+₹1,800 (0.44%)Rejected-Finance | L2 | Rejected-Finance 2nd Lowest | |
| 3 | L3₹4.2 L+₹10,164 (2.50%)Rejected-Finance VILL P O JAMBEDIA DIST BANKURA PIN 722139 | JAMBEDIA | BANKURA | WEST BENGAL | 722139 | L3 | Rejected-Finance 3rd Lowest |
Tender Value
Refer Docs
EMD Value
₹8,153
Closing Date
18 Mar 2025, 10:55 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AE/BMCESD/PWD
Kenduadihi, Gobindanagar Hospital campus, Bankura-722102
Annual Maintenance estimate of E.I work at Main Building of Bankura Sammilani Medical College and Hospital, under BSMC and H Electrical section-II, PWDte. (2024-25)------ Renovation and rectification of EI work at various location within Radiotherapy
2025_WBPWD_825046_1
WBPWDTE/AE/BMCESD/NIQ-62/Q of 2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Wise
7 days
AE/BMCESD/BANKURA
Please refer Tender documents.
3 documents required · 3 mandatory
₹8,153
Yes
7 Aug 2025
7 Mar 2025
20 Mar 2025
7 Mar 2025
18 Mar 2025
7 Mar 2025
Amount
Dismentling the existing damage, defective & non functioning Electrical accessories by Co's own tools & tackles by maintening normalcy as far as possible as per direction of EIC.
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on angle iron frame on wallwith nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse - 160A, Make - L&T/Siemens/Havells. (At Radiotherapy building)
Supplying and fixing 240/415 V Isolator on din rail of existing DBs and necessary connection Make-Legrand / Siemens, as to GS. (At Labour room) 415 V, 63A FP
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex/ Havells/KEI approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire for ECC, with drop Concealed type if reqd as per direction of EIC to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175 mm x 100 mm x 65 mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish. (At Radiotherapy & OPD building) Average run 10 mtr
Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required. (At Radiotherapy building) 200 mm x 150 mm x 65 mm
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works (At DEIC) 4 Module
6 Module
8 Module
12 Module
Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required (At DEIC)
Supply & Fixing 240 V 16 A Piano key type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required (At DEIC)
Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (At DEIC)
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (At DEIC)
Supply & Fixing 240 V, 6A, plug socket with separate 6A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150 x 100 x 65 mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. (At Radiotherapy building)
Supply & Fixing 240 V, 1 x 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F150 x 100 x 65 mm MS (16SWG) switch board and bakelite /perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. (Gynae OT, HDU & Radiotherapy building)
Distribution wiring in 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex / Havells/ KEI / Gloster /approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. 2 x 1.5 sqmm + 1 x 1.5sqmm (for Separate Plug)
2 x 2.5 sqmm + 1 x 1.5sqmm (for Power plug )
2 x 4 sqmm + 1 x 2.5 sqmm ( for AC machine )
Supplying of 1.1 KV Grade following sizes Cu. Armoured PVC/ XLPE Cable (Control cable) ( Make : Havells/ Glostar/ KEI/PWD Approved) as per direction of EIC (At Labour room) 4 core 6 sqmm ( for AC machine )
Supplying of 1.1 KV Grade following sizes Al. Armoured PVC/ XLPE Cable ( Make : Havells/ Glostar/ KEI/PWD Approved) as per direction of EIC. (At Radiotherapy building) 4 core 35sqmm ( from VTPN to MCBPBDB )
4 core 95 sqmm ( from Panel to VTPN )
Laying of cable from upto 4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting
Laying of cable from 4 core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting
Laying of cable from 4core 90 sqmm to 150 sqmm on wall/surface incl. S & F MS clams with earthing attachment in 2x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4 core 35sqmm
4 core 95 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. 4 core 35sqmm
4 core 95 sqmm
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S 1.5 sq mm
Supply of 250 V 50 HZ high flo oscillating type metal body Wall Bracket( Tornedo - 2 ) fan operated by pull cord switch with inbuilt regulator ( Make -CG/ Orient/ PWD Approved) 18" (450 mm). (At MCH & OPD building)
Fixing of Wall Bracket on wall with necessaryS&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length etc to complete the installation and mending good the damages as per direction of EIC
Supply of exhaust fan (Make -- EPC, Heavy duty/equivalent make) of following sizes as per direction of EIC. (At OPD & Radiotherapy building) 23 cm (9"), 1370 RPM
Fixing only exhaust fan after making hole in wall and making hole in wall good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of dia. 23 cm (9")
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mmdia x 62 mm long) (For Al) 23 cm (9")
Supply & Delivery of 4 feet single commercial LED type fluorescent light fittings complete with all accessories similar to Philips make cat No. TMC 501 P1 x T - LED 22 W P3 241 with Master LED Tube lamp of 1200 mm , 18W 865 T 81- 2100 ln corresponding to Wipro / Bajaj / Crompton/ Havells / PWD approved as per direction of EIC.
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. (At Radiotherapy building)
Supplying & Fixing angular holder (Anchor) on 3" wooden double round block incl. S&F 9 Watt LED lamp (Make Philips / Wipro / Bajaj / Crompton/ Havells / PWD Approved) as per direction of EIC. (At Radiotherapy building)
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc as per G.S. (At PMSSY building)
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
Supply & Fixing of 250V 50 HZ OLP- 30A single phase A.C Starter ( Make -Electron, / PWD Appvd ) suitable for 1.5 / 2.0 TR Airconditioner Machine incl S & F suitable size G I box (16 SWG) flushed in wall with voltage check, Amp check, Time check incl. making connection as per direction of EIC. (At Radiotherapy & PMSSY building)
Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting. (At Labour room & Radiotherapy building) 250 x 250 x 100 mm
GENUINE ENGINEERING WORKS (BID ID -6245748)
UJJWAL MUKHERJEE (BID ID -6238748)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .