| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹29.7 L+₹63,204 (2.17%)Rejected-Finance | L2 | Rejected-Finance Quoted amount is more than L1 | |
| 3 | L3₹30.0 L+₹86,562 (2.98%)Rejected-Finance 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | L3 | Rejected-Finance Quoted amount is more than L1 | |
| 4 | L4₹35.4 L+₹6.3 L (21.7%)Rejected-Finance SHANTI KUNJ CHESIRE HOME ROAD BARIATU RANCHI 834009 JHARKHAND | RANCHI | JHARKHAND | 834009 | L4 | Rejected-Finance Quoted amount is more than L1 | |
| 5 | L5₹35.6 L+₹6.5 L (22.5%)Rejected-Finance B 1203 VRINDA RESIDENCY BARIATU ROAD RANCHI JHARKHAND 834009 | RANCHI | RANCHI | JHARKHAND | 834009 | L5 | Rejected-Finance Quoted amount is more than L1 |
Tender Value
₹38.8 L
EMD Value
₹77,600
Closing Date
23 Nov 2023, 6:00 pmClosed
Shri Sahil Ratusaria, IDSE
Garrison Engineer Ranchi, 7th Club Road Ranchi, PIN-834001
PROVN OF UNDERGROUND CABLES FOR ELECTRICITY SUPPLY AND CONNECTED WORK AT JAMSHEDPUR MIL STN UNDER GE RANCHI
2023_MES_625469_1
8400/1202/E8
Open Tender
Civil Works
Item Rate
180 days
Ranchi
Class D Cat b (i)
6 documents required · 6 mandatory
₹500
GE Ranchi
₹77,600
Yes
9 Feb 2024
28 Oct 2023
25 Nov 2023
29 Oct 2023
23 Nov 2023
10 Nov 2023
Amount
Supply , installation , testing and commissioning in replacement indoor type cubical panel board suitable for 3 phase 4 wire 415 volt , 50 Hz and factor fabricated in an approved factory having modem fabrication process powder coating make it dust /vermin proof outer shall be made out of 3 mm thick CRCA sheet & MS angle section 50x50x6mm frame , factory fabricated double door system locakble / openable by keys from both side having chromium plated 19mm dia fancy locks, louvers & air vent gaskets for natural flow outer shall completly vermin proof inner shell be made out of 1.6mm thick CRCA sheet duly compartmentalized. 1.Incoming : LT ACB of 800 Amp Fix type , 4 pole 415 volt , 50 Hz icu 36 KA (icu=75%icu )thermally adjustable between 70-100 % 1 No. 2.Outgoing : (a) MCCB 400 Amp , 4 pole , 415 volt , 50 Hz icu 36 KA (icu=100% icu ) thermally adjustable between 70-100 % 2 Nos Make Indonesian ,HPL, Havelles (b) MCCB 250 Amp,4 pole ,415 volt ,50 HZ icu 36 KA (icu=100% icu ) thermally adjustable between 70-100 % 2 No sMake Indonesian ,HPL, Havelles (c) MCCB 125 Amp,4 pole ,415 volt ,50 HZ icu 36 KA (icu=100% icu ) thermally adjustable between 70-100 % 2 Nos Make Indonesian ,HPL, Havelles (d) Digital pannel multi function meter to measuer current , voltage , Frequency & power factor having programmable with CT size 96 mm x 96 mm accuracy class 1.0 Make HPL, L & T Indicating lamps 22.85mm dia LED type , 240 volt AC 03 Nos 600 Amp and 01 Nos 400 Amp aluminium basbar.
Supply and Laying LT cable in trenches/through pipes/ducts or on poles/walls jointing to O/H conductor, LT panels, main switch with cable size aluminum lugs and testing. XLPE insulated, armoured heavy duty electric cables with aluminum conductor, 1100 volt grade, all as specified directed by Engineer In charge of cross sectional area and core of following sizes:- Note : Excavation and earth work , sand, pipe and stone patti will be measured and paid separately
Size of cable 16 Sq.mm 4 Core
Size of cable 25 Sq.mm 3 1/2 core
Size of cable 50 Sq.mm 3 1/2 core
Size of cable 70 Sq.mm 3 1/2 core
Size of cable 95 Sq.mm 3 1/2 core
Size of cable 120 Sq.mm 3 1/2 core
Excavation in trenches not exc 1.5m wide and n. exc 1.5M deep for foundation / trenches and getting out for soft / loose soil.
Removing excavated material any type n exc 50m and depositing at a level n.exc 1.5M above ground.
Returning/filling in layers, spreading leveling, watering and well ramming in layers n.exc 25m in sof/loose soil.
S&L quarry ' M ' sand for cushioning for cable protection in trenches 8 cm before laying cable and 15 cm deep over the cable complete
M&L laying Bricks, common burnt clay building sub-class 'B' old size bricks for protection of cable in trenches complete all as directed by Engineer-in-Charge.
M&L Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 32x 6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth strip protected by galvanized iron 40 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of strata, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed by Engineer -in-charge. NOTE :- (i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) Item includes the cost of 7.5M GI pipe for protection of earth lead. Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.5 M earth lead. Any variation in length shall be adjusted through deviation order. (iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate
M&L of GI tubing light grade of size 80 mm for protection of cable in trenches/on pole, complete all as specified and directed.
M&L in of GI tubing light grade of size 50 mm for protection of cable in trenches/on pole complete all as specified and directed.
S & F junction box made from SMC/FRP sheet ready made of size 300 x 200 x 105 mm with aluminium bus bar of 100 Amp capacity for RYB and neutral made in suitbale size fixed inside the junction box with necessary supporting insulators fixed on hylem sheet fixed to pole /Wall with MS clamp 20 X 3 mm and nuts & bolts, MCB SP 6 Amp 10 KA 240 V - 1 No and aluminum lugs for connecting cables complete all as specified and directed.
S&F connecting and testing timer switch panel box size 400mm x 350mm x 170mm dust and vermin proof made of 16 gauge MS sheet factory made duly painted with two coat of synthetic enamel paint recommended colour over a coat of red oxide primer and mounted inside the following timer switch pannel box shall be fixed on one pole/wall in feeder pillar box with flat iron clamp 40x6 mm or other suitable fixing arrangement complete all as specified and directed. (a) MCB triple pole 32 Amps 230 Volt-01 No (b) Analog electro mechanical time switch 24 hours with minimum setting 30 minutes for daily working contract rating 16 Amps, 240 volts AC with initial charging battery backup having supply and reserve failure upto 150Amp hours and coil voltage 415 volts (c) AC contactor, 3 pole ML-2, 415 VOLTS, 50HZ (d) Internal Wiring with PVC insulated stranded copper conductor of suitable size and making Electric Connection -01 Nos (e) By pass MCB Single pole 32/40 Amps, 230 Volts-01 Nos. Note:- Time switch pannel box shall be fixed on one pole/wall in feeder pillar box with flat Iron clamp 40 x 6 mm or other suitable fixing arrangement complete all as specified and directed.
Supply, installation, testing and commissioning CPRI approved Make LT panel wall mounted cubical canopy type, outdoor dust and vermin proof made out of CRCA sheet 3.15 mm thick steet sheel and 40x40x6 mm angle iron section with hinged cubical doors front side openable having locking arrangements and all accessories complete as per IE rule with powder coated paint over one coat of red oxide primer complete with required fixing arrangements etc and all accessories incl necessary PCC (1 : 3 : 6) type C2 as in foundation complete all as specified and directed., comprising of the following : Incoming: (i) 250 Amp MCCB 4 Pole, 36KA - 01 No. (ii) Aluminium Bus Bar 400 Amps 4 way (iii) Digital type Ameter , range 0 to 400 Amp with slector switch and CT Make : AE (iv) Digital type Volt meter, range 0 to 500 Volt with slector switch and PT. Make : AE (v) Indicator lamp RYB LED. Outgoing: (i) 100 Amp MCCB 4 Pole, 25KA - 2 No. Make - Havells, (ii) 63 Amp MCCB 4 Pole, 25KA - 1 No. Make - Havells (iii) MCB TPN 63 Amps 25 KA Make - Legrand (iv) 3.15 mm thick CRCA Sheet and angle iron 40 X 40 X 6 mm frame (v) Timer controll unit with all accessories - 01 No
S&F LT feeder piller box 3.15 mm thick out door type, CPRI approved with 600 Amp Aluminium bus bar for RYB and half for neutral with necessary control wiring Ammeter , Volt meter, Indicating lamp and CT's comple following Incoming: (i) MCCB 400 Amp,4 pole 25 KA - 01 Nos ( As incoming) (ii) Digital Volt Meter 0-500 Volt - 01 Nos (iii) LED type Indicating lamps -03 Nos Outgoing: (i) MCCB 200 Amp ,4 pole 16 KA - 01 Nos (ii) MCCB 125 Amp ,4 pole 16 KA - 01 Nos (iii) MCCB 63 Amp ,4 pole 16 KA - 01 Nos (iv) MCCB 36 Amp ,4 pole 16 KA - 01 Nos (v) Digital Ammeter 0 - 500 Amp -01 Nos (vi) CT's 500 /5 Amp - Set of three
M/S Akash Enterprises
Raj Construction
BHARATI ENTERPRISES
arics infrastructure
Excel Enterprises
RC GUPTA AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .