Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LAccepted-AOC 45 PIR BABA TARUSHAW ROAD HALWARA AD LUDHIANA 141106 | HALWARA | LUDHIANA | PUNJAB | 141106 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹34.2 L+₹84,057.92 (2.52%)Rejected-Finance GROUND FLOOR TRACTOR MARKET KAITHAL ROAD ASSANDH KARNAL HARYANA 132039 | KARNAL | HARYANA | 132039 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹35.9 L+₹2.5 L (7.53%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹36.2 L+₹2.8 L (8.34%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹38.8 L+₹5.4 L (16.3%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
21 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Halwara
GE (AF) Halwara
PROVN/AUGMENTATION/UPGRADATION OF INTERNAL/EXTERNAL ELECTRICAL INFRASTRUCTURE OF SGT AND BELOW SMQS PH-I AT AF STN BARNALA UNDER GE (AF) HALWARA
2023_MES_576539_1
GE/HAL-70/2022-23
Open Tender
Civil Works
Item Rate
183 days
GE (AF) Halwara
MES ENLISTED CONTRACTORS CLASS D CATEGORY b(i)
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Halwara
₹86,000
Yes
24 Feb 2023
21 Jan 2023
23 Feb 2023
21 Jan 2023
21 Feb 2023
6 Feb 2023
Amount
PHASE-1 work (item No 1 to 8) :- Surface excavation in solft/loose not exceeding 30cm deep and averging 15cm deep and getting out complete all as specified and directed.
Removing excavated soil not exeeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for hard core of broken bricks of gauge not exceeding 63mm, depositing, spread and levelled in layers not exc 15cn thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 50mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregates) as in subbase to floors finished fair and even without using extra cement complete all as specified and directed.
M&L for 60mm thikc (M-35 grade) machine pressed precast concrete interlocking paver block rubber finish with grey cement and pigments of any shape and size confirming to IS 15658-2006 complete alll as specified and directed.
M&L for 60mm thikc (M-35 grade) machine pressed precast concrete interlocking paver block rubber finish with grey cement of any shape and size confirming to IS 15658-2006 complete alll as specified and directed.
M&L for sand filling under floors or foundations including watering and consolidation complete alll as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in benching and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
Phase-II work (Sl item No 9 to 27) M&L in replacement of sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLS stranded copper conductor drawn in concealed PVC conduit dia 25mm “medium quality” conduit including 6.00 Sq mm (Nominal Area) copper cable as earth continuity conductor after chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and covers including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer - in - Charge.
M&L sub-main wiring with two single core cables PVC insulated and un-sheathed 4 sqmm (Nominal Area) FRLS stranded copper conductor drawn in concealed PVC conduict dia 20mm “medium quality” conduit including 4.00 Sq mm (Nominal Area) copper cable as earth continuity conductor after chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and covers including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer - in - Charge.
S & F in repairs sheet metal enclosure for double door DBs made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted VTP & N 4 ways, 415 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCCB and isolators etc including fixing in Wall with Cement mortar complete all as specified and directed by Engineer - in - Charge. (Make - Havells / Standard / Indo Asian )
S&F MCCB TPN 63 Amps with breaking capcity 25kA ,Fixed TM and 415 volts AC Supply ISI marked complete all as specified and directed by Engineer - in - Charge. (Make - Havells / Legrand / Indo Asian)
S & F MCB ‘C’ series type suitable for 240 volts, AC supply 5 to 30 Amps , S P & N with over load and short circuit protection and rupturing capacity not less than 10KA including providing DB Box two way, single door and fixing in wall complete all as specified and directed by Engineer - in - Charge. (Make - Havells / Legrand / indoasian)
M & L for AC Box having Single pole enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 A, C series complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 03 of 2009 SSR Pt-I and testing on complete including earth work in any type of soil, PCC 1:2:4 type B-0 as in earth pit and cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, common salt, charcoal and testing on completion, all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exeeding 1.5 m deep, getting out the excavated earth nd making bottom surface to required gradient complte all as specified and directed. Note:-Excavation work will be doing through manually and adequate man power should be deployed at site.
M&L for removal of excavated material such as soils n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Returning filling in, and including spreading and leveling in layers not exceeding 25 cm thick complete all as specified & directed.
M&L for dry river washed sand filling in cable trenches for protection of cables with two layers below and above cable and punned down to speicified thickness complete all as specified and as directed. Note: Punned down thickness shall only be measured for payment.
Material and labour well burnt old size sub Class ‘B’ bricks, laid flat, in trenches for cable protection complete all as specified and as directed.
Supply, laying and testing 16 Sqmm 2 core cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade,confirming to IS7098(Part1)1988 with stranded aluminium conductor complete all as specified and directed. Note:- Before laying of cable contractor shall be produced original purchase voucher with batch/drum serial number and OEM cabel test certificates.
All as per Sl item No 21 above but 35 Sqmm 3.5 core
All as per Sl item No 21 above but 95 Sqmm 3.5 core
All as per Sl item No 21 above but 120 Sqmm 3.5 core
All as per Sl item No 21 above but 185 Sqmm 3.5 core
Supply, install, testing and commissioning LT Panel-1, Outdoor type, dust and vermin proof, totally enclosed, platform mounted, factory made having front openable shutter with locking arrangement made out of CRCA steel sheet 3.15 mm thick with MS angle iron frame work of size 40 mm x 40 mm x 6 mm thick, duly painted all as specified including necessary foundation bolts, PCC (1:2:4), type B-1 platform of suitable size for mounting the panel, suitable for 415 Volts, 50 Hz, three phase, 4 wire system with suitable insulated aluminium busbar of capacity not less than 600 Amps and shall be complete with internal wiring with copper conductor and including the following accessories:- INCOMING (i) MCCB conforming to IS:13947 (Part-II), IEC-947, TPN (4 pole), 400 Amps, 415 volts, 50 Hz, rupturing capacity 36 KA, with adjustable thermal and adjustable magnetic setting - 01 No (ii) LED Multifucntional Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs (iii) LED indicating lamps with colour Red, Yellow, Blue (03 Lights) - 01 Set OUTGOING (i) MCCB conforming to IS:13947 (Part-II), IEC-947, 4 pole, 63 Amps, 415 volts, 50 Hz, rupturing capacity 25 KA, with adjustable thermal and adjustable magnetic setting = 06 Nos (for Each block 06 Nos Block)
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized iron strip 32×6mm (up to 7.5m in length from earth plate) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shwon in electrical plate no 3 of SSR part 1 including Charcoal, Rock salt, necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS bar 8mm dia 150mm c/c reingorcement, watering funnel, 15 mm dia light grade for protection of earth electrode, 20 mm dia for watering all as speicified and directed and tested on completion.
SWARN SINGH AND CO.
SANGAM ENGINEERS
R D Bansal
S K BANSAL AND CO.
M/s Kataria Construction Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .