Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹36.7 L+₹2.6 L (7.78%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹39.5 L+₹5.4 L (16.0%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
18 Sept 2023, 6:00 pmClosed
GE MINNIRBAY
GE MINNIEBAY JUNGLIGHAT POST MINNIEBAY PORT BLAIR 744103
PROVN OF HIGH MAST LIGHT WITH 12 NOS LED LIGHT FITTINGS AT NAD DOLLYGUNJ AND PROVN OF LIGHT ILLUMINATION OF ROAD AT INS UTKROSH AND SPL REPAIRS TO STATIC TANKS (T-20 AND T-21) AT BV YARD UNDER GE MINNIEBAY PORT BLAIR
2023_MES_614795_1
8294/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
MINNIEBAY PORT BLAIR
As per tender documents
10 documents required · 10 mandatory
₹500
GE MINNIEBAY
₹80,000
Yes
18 Oct 2023
21 Aug 2023
20 Sept 2023
22 Aug 2023
18 Sept 2023
5 Sept 2023
Amount
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and as directed by Engr-in-Charge
Demolition of Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engr-in-Charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specially provided for complete all as specified and as directed by Engr-in-Charge.
M&L for Reinforced Cement Concrete M30 grade (Design Mix) using 20mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs and mass concrete including formwork all as specified and as directed by Engr-in-Charge.
M&L for Reinforced Cement Concrete M30 grade (Design Mix) using 20mm graded stone aggregate as in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footing including attached pilasters and buttresses including formwork complete all as specified and as directed by Engr-in-Charge.
M&L for CRS TMT bars 10mm dia and over cut to length, bent to shape required incl cranking, bending, spirally for hooping for columns, hooking end and binding with and incl mild steel wire not less than 0.9mm dia or securing with clip quality confirming to deformed or twisted bars complete all as specified and as directed by Engr-in-Charge..
M&L for taking down cement plaster on brick wall and racking out joints hacking for key sucrubing down with water etc complete all as specified and as directed by Engr-in-Charge.
M&L for rendering 15mm thick in two layers of first layer 10mm thick in CM (1:6) and second layer 5mm thick rendering in CM (1:4) using water proofing compound (WPC will be paid separately) on brick masonry or stone or block masonry or concrete surfaces complete all as specified and as directed by Engr-in-Charge.
Supply only Integral water proofing compound ISI marked complete all as specified and as directed by Engr-in-Charge.
M&L for 100mm thick plain cement concrete 1:2:4 type B-1 Nominal mix using 20 mm graded stone aggregate as in flooring including formwork complete all as specified and as directed by Engr-in-Charge
S&F framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks & similar work conforming to Fe 290-0 Gde E-165 complete all as specified and as directed by Engr-in-Charge
M&L for preparation of new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engr-in-Charge
M & L for preparation of new plastered surfaces and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed by Engr-in-Charge
M&L for removing loose and broken concrete/ masonary surface by chiseling/ mechanically etc from the roof slab, column, beam and similar structural members cutting edges, cleaning the dismantled portion with wire brush etc to make the reinforcement naked and remove dust, dirt and other foreign particle etc and removig to debries 50m from site complete all as specified by Engineer-in-Charge.
M&L for applying single component polymer based rust-remover (pH value –12 ) and applying polymer based anti corrosive primer (pH value-9) to all exposed reinforced bars as manufacturer instruction complete all as specified by Engineer-in-Charge.
M&L for applying one coat of epoxy bonding coat as per manufacture's instruction to bind with old concrete / wall surfaces of soffit of slab, coloumn, beam and similar structural members for new cement surface complete all as specified and as directed by Engr-in-Charge.
M&L for applying polymer modified cement mortar rendering 15mm average thick in CM 1:3 on concrete surface duly mixing polymer modifier, finished even and smooth without using extra cement all as per manufacturer's instructions complete all as specified and as directed by Engr-in-Charge.
M&L for drilling 15mm dia holes in to RCC slab / wall / Column /beams to a depth of 100 to 150 mm and fixed with polyster resin grout mixed mechanically and pour the same into the hole and insert the shear connector and finish the top; allow the same to set complete all as per manufacturer's instructions and as directed by Engineer-in-Charge.
S&F of hard down steel wire fabric not exceeding 4 Kg / sqm cut to lengths, bent to shape required and tying with annealed MS wire not less than 0.9mm dia welding to existing reinforcement complete all as specified and as directed by Engineer-in-charge.
M&L for pressure guniting 40 mm average thickness in cement mortar 1:3 to all affected RCC structures including necessary scaffolding modyfying with mortar with polymer based resin & hardener complete all as per manufacturer's instructions including making good as directed by the Engineer-in-Charge. Note : Due to rebound during the pressure application, some wastage factor not more than 10% shall be considered for calculation purpose as per manufacturer's recommendations.
M&L for applying curing compound on gunited surface for complete curing as per manufacturer's instructions complete all as specified and as directed by Engr-in-Charge. NOTE FOR ITEM NO 14 to 21 : (i) The successful contractor shall execute the structural repair and rehabilitation work through the Manufacturer's authorised applicator only and the copy of the agreement/certification for the same shall be submitted to the Accepting officer for approval before the execution of the work. An amount of 5 % of the quoted amount subject to a minimum Rs.50,000/- shall be retained against security deposit against the structural repair work under the respective items and gurantee bond for the same shall be also submitted in Non Judicial stamp paper duly notarized along with the deposit amount & carrying out Structural NDT test from NABL approved lab for enhanced strength after the completion of work. The contractor shall quoted accordingly and no claim shall be entertained later.
M & L for writing letters or figures (Block , Roman , Italic or Indian) n exc 30 cm high using synthetic enamel paint complete all as specified and as directed by Engr-in-Charge
Supply , Install , testing & commissioning of 16m high mast lighting system with all accessories including all fittings and fixtures complete all as specified and as directed by Engr-in-Charge. The light system consist of following specifications:- (a) Mast shaft shall be in three sections, hot dip galvanised and suitable for wind velocity as per IS 875 Par 3. (b) It shall also include accessories for high mast including head frame, stainless steel wire 6 mm dia rope,integral motor,connector,manual handle,lightining finial ,construction, double drum winch, Galvanised Lantern carriage arrangement suitable for 12 luminaries symmetrically & its control gear boxes and lightning finial. (c) The mast shall have an integral Power Tool installed inside the base compartment for its motorised operation also manual operation (d) Design and casting of suitable RCC foundation with M-30 grade concrete. Size and depth of foundation shall be assessed by considering SBC of soil as per actual site condition. Rate of soil testing from IIT/NIT/ other NABL approved lab for finding out SBC shall be included in the quoted rate and report shall be submitted before execution of the work
(e) M&L for High mast light foundation / bedding with PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as per manufacturing instructions complete. (f) S & F foundation bolts manufactured from special steel along with nuts, washer, anchor plate and templates. (g) S & F LED type single dome aviation obstruction light - 01 Nos and including all connected wiring complete. Make : Bajaj , Crompton or equivalent. (h) M&L for foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete M-30 grade shall be as per manufacturer's recommendations. Foundation drawing shall be submitted to GE duly signed by manufacturer, contractor and recommended by Engineer-in-Charge for approval before execution of work at site. The necessary soil testing shall be carried by IIT/NIT/ other NABL approved labs and its report shall be submitted before the execution of the work and cost of the same shall deemed to be included in this quoted rate.
(j) M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete. (k) S & F outdoor stand mounted feeder pillar box 3.15mm thick CRCA sheet, CPRI approved with 32A TPN MCB incomer, single dial time switch, 25A TP contactor for the automatic switching of luminaries, power tool control with 2 Nos 9A contactors and raise lower push button, Incoming 35 sq. mm and out going 16 & 2.5 sq. mm terminals complete all as specified and as directed by Engr-in-Charge. (l) S & F LED floodlight 200 W -12 Nos incluing all accessories and silicon filled ported driver, IP 66 protection, driver must have BIS registered complete all as specified and as directed by Engr-in-Charge. (m) Trailing cable PVC armoured type from luminaries to the base of pole and from base to feeder pillar box. (n) Provision of lightning finial at the top of the pole.
M & L for earthing complete with GI earth electrode of size 60cmx60cmx6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level wuith top edge of earth plate at a depth not less than 1.5 metre below normal ground surrounded from all sides by 15cm thick and packed layer of charcoal dust and conmmon salt filling in alternate layers cleaned connected to and including GI earth strip 32 x 6mm size upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected light grade 50mm dia 5 mtr long GI pipe connected to main control board and GI pipe light grade 20mm bore for watering and including funnel wire mesh, RCC pit cover 50mm thick with 10mm dia reinforcement 100mm c/c and PCC chamber pit with pcc 1:2:4 Type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part -I 2009 complete all as specified as directed by Engr-in-Charge
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized earth strip of 25x4mm size by means of bolts, nuts, check nuts and washers of galvanized iron or steel and connected from earth plate electrode to main switch board/ earthing test point including watering arrangement with 20 mm GI pipe medium grade,40 mm GI pipe light grade for earth strip protection, PCC 1:3:6 type C1 chamber, MS funnel, wire gauge, 50mm thick precast RCC cover in Type B1, including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to a distance n.exc 50m, charcoal and salt complete all as shown in electrical plate No. 3 of Schedule Part-I 2009 and connected to earthing test point all as specified or indicated and testing on completion
Supply & erect steel tubular swaged poles complete in true vertical position, with GI base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP - 31, 9.0m long, with polycarbonate cable junction box with IP-67 rating of suitable size with aluminium lugs one incoming and out going with terminal set independently complete all as specified and directed by Engr-in-Charge. Note : Cost of foundation for fixing of poles shall be measured and paid separately under relevant item of this schedule
Supply & erect steel tubular swaged poles complete in true vertical position, with GI base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP - 31 11.0m long, with polycarbonate cable junction box with IP-67 rating of suitable size with aluminium lugs one incoming and out going with terminal set independently complete all as specified and directed by Engr-in-Charge. Note : Cost of foundation for fixing of poles shall be measured and paid separately under relevant item of this schedule
S&F LED security lights fitting 90 Watt, new generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with high power LED as light source including all connecting accessories complete all as specified as directed by Engr-in-Charge. Make : Cat part No LSTP-90-CDL of CROMPTON or equivalent in PHILIPS/ Havells
S&F security light for downward illumination LED, 120 W /240V streetlight made up of pressure die cast housing with high efficiency LEDs as lighting source and lens embedded PC cover having top opening separate driver compartment with IP 66 protection and impact resistance of IK07 including all fittings complete as specified and as directed by Engr in charge Make : Havells , model No.ENDURAOMNIPLUSSL 120WLED757SASYTOPC
S&F LED Beam/Flood light fitting 4x100 Watt 6500 K - 286mm x 236mm complete with all accessories internally pre-wired and including with all necessary fitting accessories and testing & completion complete all as specified and directed.
S & F street light bracket 40mm dia medium grade ISI marked 1.5m, bend in suitable shape and fixed with clamps of suitable size and numbers with nuts, bolts & washers etc. complete all as specified and directed by Engr-in-Charge.
Supply, lay, testing and commissioning under ground cable XLPE insulated, armoured heavy duty electric cable, 1100 volts grade with stranded aluminium conductor in trenches including suitable size of double grip cable gland and jointing etc complete all as specified as directed for the following sizes complete all as specified and as directed by Engr-in-Charge :-
4 core 16 Sqmm.
3.5 core 50 Sqmm.
3.5 core 95 Sqmm.
3.5 core 120 Sqmm.
Excavation in trenches, not exceeding 1.50m wide and not exceeding 1.50m in depth for foundations, trenches of cable or pipe lines etc or and getting out in soft / loose soil complete all as specified and as directed by Engr-in-Charge.
Excavation in trenches, not exceeding 1.50m wide and not exceeding 1.50m in depth for foundations, trenches of cable or pipe lines etc or and getting out in hard / dense soil or roads complete all as specified and as directed by Engr-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm complete all specified and as directed by Engr-in-Charge.
Removing excavated surplus soil to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point complete all specified and as directed by Engr-in-Charge.
Supply, laying of DWC (double Wall corrugated) HDPE pipe ISI marked of inner dia 75 mm and outer dia 90mm polyethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure under ground cable complete all as specified and as directed by Engr-in-Charge.
Supply, laying of DWC (double Wall corrugated) HDPE pipe ISI marked of inner dia 100 mm and outer dia 120mm polyethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure under ground cable complete all as specified and as directed by Engr-in-Charge.
Supply, laying of DWC (double Wall corrugated) HDPE pipe ISI marked of outer dia of 77 mm and inner dia 63 mm polyethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure under ground cable complete all as specified and as directed by Engr-in-Charge.
Supply and commissioning of LT cubical outdoor type enclosure (Box type) CPRI approved, made out of CRCA sheet 3.15 mm thick totally enclosed with front opening, with projected an raised platform of suitable size weather and vermin proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switch gear about load termination, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 with necessary arrangement for the below mentioned items complete & powder coating, necessary internal electric connection as required and provision of the following:- Note : Drawing of LT panel CPRI approved from one of the makes specified in tender shall be submitted by the contractor duly approved by Engineer-in-Charge. (a) MCCB 250 Amp 4 Pole 50 Hz 415 V with rupturing capacity 36 kA - 01 No (b) MCCB 63 Amp 4 Pole 50 Hz 415 V with rupturing capacity 25 kA - 03 Nos (c) MCCB 100 Amp 4 Pole 50 Hz 415 V with rupturing capacity 25 kA- 03 Nos (d) MCB TPN 40 Amp - 02 Nos (e) Digital Volt meter 0-500V AC single phase (f) Digital Ammeter 0-20 A (g) Indicating lamp - RYB
Supply and commissioning of LT cubical outdoor type enclosure (Box type) CPRI approved manufacturer made out of CRCA sheet 3.15 mm thick totally enclosed with front opening, with projected an raised platform of suitable size weather and vermin proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switch gear about load termination, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 with necessary arrangement for the below mentioned items complete & powder coating, necessary internal electric connection as required and provision of the following:- Note : Drawing of LT panel CPRI approved from one of the makes specified in tender shall be submitted by the contractor duly approved by Engineer-in-Charge. (a) MCCB 200 Amp 4 Pole 50 Hz 415 V with rupturing capacity 36 kA- 01No (b) MCCB 100 Amp 4 Pole 50 Hz 415 V with rupturing capacity 25 kA - 03 Nos (c) MCCB 63 Amp 4 Pole 50 Hz 415 V with rupturing capacity 25 kA - 03 Nos (d) MCB TPN 40 Amp -2 Nos (e) Digital Volt meter 0-500V AC single phase (f) Digital Ammeter 0-20 A (g) Indicating lamp - RYB
S&F unarmoured electric power cable (Heavy duty) with stranded copper conductor for 1100 volts grade of 3 core 1.5 Sqmm cross sectional area for street lights including PVC conduits of suitable size complete all as specified and as directed by Engr-in-Charge
Supply & Laying GI pipe, medium grade, of 80mm bore ISI marked for passing cable in trenches, under road/walls etc complete all as specified and as directed by Engr-in-Charge
M & L for Plain cement concrete 1:4:8, type D-2, Nominal mix using 40 mm graded stone aggregate as in foundation, filling and mass concrete all aspecified and as directed by Engr-in-Charge
M&L for Plain cement concrete 1.3.6 type C2, Nominal mix using 40mm graded stone aggregate in foundations filling and mass concrete all aspecified and as directed by Engineer-in-Charge
M&L for Plain cement concrete 1:2:4 type B1, Nominal mix using 20mm graded stone aggregate for pole coping including necessary form work all as specified and as directed by Engineer-in-Charge
S & F PVC Junction box IP-67 ISI marked suitable for MCB SP including nut bolts washer clamps etc complete to be fixed on the steel tubular all as specifed and as directed by Engr-in-Charge Note:- MCB SP shall be measured and paid under respective item of the schedule.
S & F MCB SP 6-32 Amps 'C' series AC 230 Volts breaking capacity 16KA all as specifed and as directed by Engr-in-Charge .
S & F astronomical timer switch for security light, to be fixed on existing LT panel, range 6W to 12W confirming to IS/IEC 60947-1 provided with protection degree IP 54, Extrended with brand coil, with FRLS internal wiring, inbuild short circuit protection,Class H insulation all aspecified and as directed by Engr-in-Charge
S & F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 6mm dia galvanised iron or steel wire including connecting with the earth pit complete all aspecified and as directed by Engr-in-Charge
M&L for road cutting, removing of material , returning filling and PCC 1:2:4 Nominal mix using 20mm graded stone aggregate for laying of LT UG cable /Galvanised Iron Pipe/Rex Pipe all as specified and as directed by Engineer-in-Charge.
M/S VISHAL CONSTRUCTION
M/s G K Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .