Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.0 LAccepted-AOC 27 WESTERN STREET ROOM NO 307 KOLKATA 700012 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700012 | ₹31.0 L Quoted ₹32.2 L | L1 | Accepted-AOC Approved |
| 2 | L2₹35.1 L+₹2.9 L (8.95%)Rejected-Finance | ₹35.1 L+₹2.9 L (8.95%) | L2 | Rejected-Finance Not the lowest bidder |
| 3 | L3₹35.1 L+₹3.0 L (9.23%)Rejected-Finance 28 GREEN PARK PO BELGHARIA KOLKATA WEST BENGAL 700 056 | 24 PARAGANAS NORTH | WEST BENGAL | 700056 | ₹35.1 L+₹3.0 L (9.23%) | L3 | Rejected-Finance Not the lowest bidder |
| 4 | L4₹35.9 L+₹3.7 L (11.6%)Rejected-Finance | ₹35.9 L+₹3.7 L (11.6%) | L4 | Rejected-Finance Not the lowest bidder |
| 5 | L5₹37.0 L+₹4.9 L (15.1%)Rejected-Finance 309 VINAYAK TOWER CUTTACK PURI ROAD BHUBANESWAR 751 006 | KHORDHA | ODISHA | 751006 | ₹37.0 L+₹4.9 L (15.1%) | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
14 Dec 2020, 6:00 pmClosed
GE I R and D Chandipur
GE I R and D Chandipur Post Chandipur Dist Balasore 756025
REWIRING REPAIR/ REPLACEMENT OF ELECT FITTING AND FIXTURE AND EARTHING OF MD AND TECH ACCN AT PXE CHANDIPUR (3RD CALL)
2020_MES_384124_3
8584/CDP
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Chandipur
Please Refer Tender Documents
6 documents required · 6 mandatory
₹500
Yes
GE I R and D Chandipur
₹58,000
Yes
21 Dec 2020
7 Dec 2020
16 Dec 2020
7 Dec 2020
14 Dec 2020
9 Dec 2020
Amount
Taking down carefully copper/aluminium point wiring for light, fans, socket or power point including sunken MS boxes, fittings such as switches, ceiling roses, call bell, pendants, regulators, socket, etc by unscrewing from board carefully and making good disturbed surfaces of walls, floors etc. with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as specified & directed.
M&L Point wiring with two runs of FR grade PVC insulated unsheathed stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FR grade PVC insulated unsheathed stranded copper conductor as for earth continuity wire to be drawn in and including PVC casing & caping (medium grade) not less than 25 mm width with fittings & fixtures including sunk MS sheet metal switch / terminal box 1.22 mm thick upto (200x300) mm size duly covered with backelite sheet cover 3.00mm thick fixed with brass screws and continutiy conductor shall be connected to common earth dolly for one light point / one fan point controlled by one 5/6 amps, one way switch complete all as specified & directed. Make of wire: Finolex / Polycab / Plaza Make of PVC Casing-N- Caping : Plaza / Prestoplast / Precision
M&L for point wiring with FR grade PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm for earth continuity wire, to be drawn in and including PVC rigid conduit heavy duty of size not less than 25 mm dia with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one light / fan point controlled by one 5/6 amps, one way switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FR grade PVC insulated unsheathed stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FR grade PVC insulated unsheathed stranded copper conductor as for earth continuity wire to be drawn in and including PVC casing & caping (medium grade) not less than 25 mm width with fittings & fixtures including sunk MS sheet metal switch / terminal box 1.22 mm thick upto (200x300) mm size duly covered with backelite sheet cover 3.00mm thick fixed with brass screws and continutiy conductor shall be connected to common earth dolly for one call bell point controlled by one, one way bell push complete all as specified & directed. Make of wire: Finolex / Polycab / Plaza Make of PVC Casing-N- Caping : Plaza / Prestoplast / Precision
M&L Point wiring with two runs of FR grade PVC insulated unsheathed stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FR grade PVC insulated unsheathed stranded copper conductor as for earth continuity wire to be drawn in and including PVC casing & caping (medium grade) not less than 25 mm width with fittings & fixtures including sunk MS sheet metal switch / terminal box 1.22 mm thick upto (200x300) mm size duly covered with backelite sheet cover 3.00mm thick fixed with brass screws and continutiy conductor shall be connected to common earth dolly for one 3 pin socket outlet 5/6 Amps on same board with other switch complete all as specified & directed. Make of wire: Finolex / Polycab / Plaza Make of PVC Casing-N- Caping : Plaza / Prestoplast / Precision
M&L Point wiring with two runs of FR grade PVC insulated unsheathed stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FR grade PVC insulated unsheathed stranded copper conductor as for earth continuity wire to be drawn in and including PVC casing & caping (medium grade) not less than 25 mm width with fittings & fixtures including sunk MS sheet metal switch / terminal box 1.22 mm thick upto (200x300) mm size duly covered with backelite sheet cover 3.00mm thick fixed with brass screws and continutiy conductor shall be connected to common earth dolly for one 3 pin socket outlet 5/6 Amps on independent board controlled with one 5/6 Amps, one way switch complete all as specified & directed. Make of wire: Finolex / Polycab / Plaza Make of PVC Casing-N- Caping : Plaza / Prestoplast / Precision
M&L Point wiring with two runs of FR grade PVC insulated unsheathed stranded copper conductor of size 2.5 Sqmm (phase & neutral) and one run of 2.5 Sqmm FR grade PVC insulated unsheathed stranded copper conductor as for earth continuity wire to be drawn in and including PVC casing & caping (medium grade) not less than 25 mm width with fittings & fixtures including sunk MS sheet metal switch / terminal box 1.22 mm thick upto (200x300) mm size duly covered with backelite sheet cover 3.00mm thick fixed with brass screws and continutiy conductor shall be connected to common earth dolly for one 5/15 Amps socket outlet on independent board controlled with one 15 Amps, one way switch complete all as specified & directed. Make of wire: Finolex / Polycab / Plaza Make of PVC Casing-N- Caping : Plaza / Prestoplast / Precision
Taking down unserviceable sub main /Sub circuit wiring of any type and size including conduit, batten wiring for necessary repair/replacement.
M&L Sub main wiring using two runs of FR grade PVC insulated, unsheathed, stranded, copper conductor cable of size 2.5 Sqmm and one run of 2.5 Sqmm FR grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including PVC Casing caping (medium grade) including accessories of suitable size not less than 25 mm width complete all as specified and as directed. Note : Two runs of 2.5 Sqmm copper wire,one run of 2.5 Sqmm wire & one run PVC Casing-N-caping shall be measured as one unit. Make of wire: .(Make of wire: Finolex/Polycab/Plaza Make of PVC Casing-N- Caping :-Plaza/Prestoplast/Precision)
M&L Sub main wiring using two runs of FR grade PVC insulated, unsheathed, stranded, copper conductor cable of size 2.5 Sqmm and one run of 2.5 Sqmm FR grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including PVC rigid conduit of size not less than 25 mm dia including accessories concealed in wall including making good disturbed surfaces of walls, floors etc. with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as specified and as directed. Note : Two runs of 2.5 Sqmm copper wire,one run of 2.5 Sqmm wire & one run PVC Casing-N-caping shall be measured as one unit. Make of wire: .(Make of wire: Finolex/Polycab/Plaza Make of PVC Casing-N- Caping :-Plaza/Prestoplast/Precision)
M&L Sub main wiring using two runs of FR grade PVC insulated, unsheathed, stranded, copper conductor cable of size 4.0 Sqmm and one run of 4.0 Sqmm FR grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including PVC Casing caping (medium grade) including accessories of suitable size not less than 25 mm width complete all as specified and as directed. Note : Two runs of 4.0 Sqmm copper wire,one run of 4.0 Sqmm wire & one run PVC Casing-N-caping shall be measured as one unit. Make of wire: .(Make of wire: Finolex/Polycab/Plaza Make of PVC Casing-N- Caping :-Plaza/Prestoplast/Precision)
M&L Sub main wiring using two runs of FR grade PVC insulated, unsheathed, stranded, copper conductor cable of size 4.0 Sqmm and one run of 4.0 Sqmm FR grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including PVC rigid conduit of size not less than 25 mm dia including accessories concealed in wall including making good disturbed surfaces of walls, floors etc. with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as specified and as directed. Note : Two runs of 4.0 Sqmm copper wire,one run of 4.0 Sqmm wire & one run PVC Casing-N-caping shall be measured as one unit. Make of wire: .(Make of wire: Finolex/Polycab/Plaza Make of PVC Casing-N- Caping :-Plaza/Prestoplast/Precision)
M&L Sub main wiring using two runs of FR grade PVC insulated, unsheathed, stranded, copper conductor cable of size 6.0 Sqmm and one run of 6.0 Sqmm FR grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including PVC Casing caping (medium grade) including accessories of suitable size not less than 25 mm width complete all as specified and as directed. Note : Two runs of 6.0 Sqmm copper wire, one run of 6.0 Sqmm wire & one run PVC Casing-N-caping shall be measured as one unit. Make of wire: .(Make of wire: Finolex/Polycab/Plaza Make of PVC Casing-N- Caping :-Plaza/Prestoplast/Precision)
M&L Sub main wiring using two runs of FR grade PVC insulated, unsheathed, stranded, copper conductor cable of size 6.0 Sqmm and one run of 6.0 Sqmm FR grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including PVC rigid conduit of size not less than 25 mm dia including accessories concealed in wall including making good disturbed surfaces of walls, floors etc. with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as specified and as directed. Note : Two runs of 6.0 Sqmm copper wire,one run of 6.0 Sqmm wire & one run PVC Casing-N-caping shall be measured as one unit. Make of wire: .(Make of wire: Finolex/Polycab/Plaza Make of PVC Casing-N- Caping :-Plaza/Prestoplast/Precision)
S&F Switch piano, flush type, single pole, one way 5/6 Amps, 240V complete all as directed by Engineer-in-Charge. Make:- Anchor/Cona/Roma.
Fixing only Switch piano, flush type single pole, one way, 5 Amps (Serviceable switch obtained from Sl Item No. 1 shall be reused).
S&F Bell push Switch, flush type, single pole, one way 5/6 Amps, 240V complete all as directed by Engineer-in-Charge. Make:- Anchor/Cona/Roma.
S&F Call Bell ,single pole, AC, 230 Volts complete all as directed by Engineer-in-Charge. Make:- Anchor/Cona/Roma.
S&F Switch socket combination 2 in 1, 5 pin, 5/6 Amps flush type 240 Volt . Make:- Anchor/ Cona/Roma.
Fixing only Switch socket combination (Serviceable switch socket combination obtained from Sl Item No. 1 shall be reused)
S&F Switch socket combination 5/15 Amps flush type,6 pin,5 in 1. Make:- Anchor/Cona/Roma
Fixing only Switch socket combination 15/16 Amps (Serviceable Switch socket combination obtained from Sl Item No 1 shall be reused)
S & F Ceiling rose surface bakelite, PVC/Polycarbonite, 63.5 mm x 23.5 mm, 3 terminals, isolated body, complete all as specified and as directed. Make:- Anchor / Cona/Roma.
Fixing only ceiling rose (Serviceable Ceiling rose obtained from Sl Item No 1 shall be reused)
S&F Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings. Make:- Anchor / Cona/Roma.
Fixing only lamp holder (Serviceable Lamp holder obtained from Sl Item No 1 shall be reused)
Supply and fixing of Step type electronic regulator flush type on the existing phonolic laminated sheet etc as required (Make : .Anchor/Cona/Roma)
S&F MCB DB made of sheet steel phosphatised, powder painted, double door with bus bar, neutral link, earth bar and din rail of TPN 4 way, 415 Volts fixed in wall, making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces including taking out old DB with fittings & fixtures complete all as specified (Make : STANDARD/HAVELLS/L&T/LEGREND )
S&F MCB DB made of sheet steel phosphatised, powder painted double door with bus bar, neutral link, earth bar and din rail of SPN 4 way, 240 Volts fixed in wall, making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces, including taking out old DB with fittings & fixtures complete all as specified. (Make : STANDARD/ HAVELLS/L&T/LEGREND )
S&F MCB DB made of sheet steel phosphatised, powder painted double door with bus bar, neutral link, earth bar and din rail of SPN 6 way, 240 Volts fixed in wall, making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces, including taking out old DB with fittings & fixtures complete all as specified. (Make/Model :Cat No:DBSPN006DD of L&T or STANDARD/ LEGREND )
S&F MCB DB made of sheet steel phosphatised, powder painted with bus bar, neutral link, earth bar and din rail of SPN 8 way, 240 Volts double door fixed in wall, making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces, including taking out old DB with fittings & fixtures complete all as specified.(Make : STANDARD/L&T/LEGREND
S&F MCB DB made of sheet steel phosphatised, powder painted double door with bus bar, neutral link, earth bar and din rail of SPN 12 way, 240 Volts fixed in wall, making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces, including taking out old DB with fittings & fixtures complete all as specified. (Make : STANDARD/ L&T/LEGREND )
Supply and fixing of VTPN DB double door,IK 09,IP43-Metal door, 4 way, made of CRCA sheet steel ,RAL 9003,powder coated with bus bar, neutral link, earth bar withprovision for DU125A MCCB,4 pole as incomer and SP/TP MCBs as Outgoings, making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces including taking down old one. (Make/Model- DBVTL004DD of L&T or Equivalent of HPL/LEGRAND.
S&F MCCB 4 pole, with fixed thermal & magnetic release of breaking capacity 30 kA, 415 Volts, 63 Amps.(Make: L&T,Cat No.CM9793OOJ2 or Standard/Legrand)
S&F MCCB 4 pole, with fixed thermal & magnetic release of breaking capacity 30 kA, 415 Volts, 100 Amps.(Make: L&T,Cat No.CM9793OOK2 or Standard/Legrand)
S&F MCCB 4 pole, with fixed thermal & magnetic release of breaking capacity 30 kA, 415 Volts, 125 Amps.(Make: L&T,Cat No.CM90679OOLO or Standard/Legrand)
S&F Isolator, FP, 415 Volt 63 A, breaking capacity 35 KA (Make L&T,Cat No.BF406300 or Standard/Legrand)
S&F Isolator, FP, 415 Volt 100 A, breaking capacity 35 KA (Make L&T,Cat No.BF410000 or Standard/Legrand)
S&F MCB, SPN. 6-32 Amps rating 240, volt, 'C' series, 10 kA (Make L&T,Cat No.BB20320D or Standard/Legrand)
Fixing only MCB SPN 6-32 Amps, rating 240 volts, 'C' series, 10 KA (Serviceable MCB obtained from Sl Item No. 28 to 32 shall be reused).
S&F MCB, SP, 6-32 Amps, 240 volt, 'C' Series, 10 kA ( Make L&T,Cat No.BB10320D or Standard & Legrand / HPL).
Fixing MCB SP 6-32 Amps (Serviceable MCB obtained from Sl Item No.28 to 32 shall be reused).
Supply and fixing of Round surface mounted LED Slim panel of capacity 12 watt PDC white finish aluminium housing with high translucent frosted plastic diffuser of robust Luminaire with efficacy of 100lm/w including connecting up with twin core 0.50 Sqmm twisted flexible copper conductor cable including taking down old light fittings. (Make/Model No:-LCDSPLN-R-12-CDL(PEARL NIOS-R) of Crompton or equivalent of Bajaj/Jaguar/ Century Magik)
Supply and fixing 1x10 watt ( 2ft ) LED Baton indoor decorative type Integral sleek polycarbonate LED Channel with white acrylic cover complete with all accessories internally pre-wired and including connecting up with twin core 0.50 Sqmm twisted flexible copper conductor cable including taking down old light fittings complete all as specified and directed. ( Make /Model No :-BCLSB 10 NW of Bajajor equivalent of Crompton/Jaguar/ Century Magik.
Supply and fixing Highly robust industrial Box type LED extruded Batten type indoor decorative type luminaire suitable for LED Tube 2 x 16/20 watt (4ft ) complete with all accessories internally pre-wired and including connecting up with twin core 0.50 Sqmm twisted flexible copper conductor cable including taking down old light fittings complete all as specified and directed. ( Make /Model No :-IGP162LT8-16( ECO-I )of Crompton or equivalent of Bajaj/Jaguar/Phillips)
Supply and fixing Highly robust industrial Box type LED extruded Batten type indoor decorative type luminaire suitable for LED Tube 1 x 16/20 watt (4ft ) complete with all accessories internally pre-wired and including connecting up with twin core 0.50 Sqmm twisted flexible copper conductor cable including taking down old light fittings complete all as specified and directed. ( Make /Model No :-IGP161LT8-16( ECO-I )of Crompton or equivalent of Bajaj/Jaguar/Phillips)
S&F LED Polycarbonate T8 Tube with in built driver with metal heat sink double sided connection of capacity 1x 20 watts including connecting up with twin core 0.50 Sqmm twisted flexible copper conductor cable including taking down old light fittings all as specified and directed, Make/Model No:-LT8-20-865-(2) ULTRON of Crompton or equivalent of Bajaj/ Phillips/ Jaquar
S&F in repairs heavy anchor bolts made of mild steel of size 10mm dia 75mm long including necessary drilling on wall for fixing of steel frame all as specified & directed.
Supply and fixing sheet metal encloser box including Plug and socket with 20 Amps MCB (SP) with taking down old U/S existing sheetmetal enclosure. ( Make L&T/Legrand /Standard).
Supply and fixing sheet metal encloser box including Plug and socket with 20 Amps MCB (SPN) with taking down old U/S existing sheetmetal enclosure. ( Make L&T/Legrand /Standard).
Disconnecting electrical wire from ceiling rose, taking down ceiling fan of any type/size/sweep and make, removing dust & other substances from bearing, bush by using kerosene oil, carrying out fresh lubrication using grease and to make the fan noise free for smooth functioning (including replacement of worn-out / unserviceable capacitor, connector, canopy, bearing, down road, clamps, PVC cable etc), replacement of split pin, nut, bolts,screws,washers and assembling the repaired fan including painting with one coat of synthetic enamel paint of existing colour code including writing MES No with black synthetic enamel paint complete including testing and hanging the fan as its own position, connection with point wiring complete all as directed by Engineer-in-Charge. (NOTE : Spare parts to be replaced shall be measured and paid separately as supply only items here-in-after.)
Disconnecting electrical wire from ceiling rose, taking down exhaust fan 300 mm / 380 mm sweep and make, removing dust & other substances from bearing, bush by using kerosene oil, carrying out fresh lubrication using grease and to make the fan noise free for smooth functioning (including replacement of worn-out / unserviceable capacitor, connector, canopy, bearing, louvers, PVC cable etc), replacement of nut, bolts,screws,washers and assembling the repaired fan including painting with one coat of synthetic enamel paint of existing colour code including writing MES No with black synthetic enamel paint complete including testing and fixing the fan as its own position, connection with point wiring complete all as directed by Engineer-in-Charge. (NOTE : Spare parts to be replaced shall be measured and paid separately as supply only items here-in-after.)
Disconnecting electrical wire from ceiling rose, taking down wall mounting fan size upto 600 mm sweep and make, removing dust & other substances from bearing, bush by using kerosene oil, carrying out fresh lubrication using grease and to make the fan noise free for smooth functioning (including replacement of worn-out / unserviceable capacitor, connector, canopy, bearing, louvers, PVC cable etc), replacement of nut, bolts,screws,washers and assembling the repaired fan including painting with one coat of synthetic enamel paint of existing colour code including writing MES No with black synthetic enamel paint complete including testing and fixing the fan as its own position, connection with point wiring complete all as directed by Engineer-in-Charge. (NOTE : Spare parts to be replaced shall be measured and paid separately as supply only items here-in-after.)
Rewinding of the motor of AC ceiling Fan of any make and size (1200 / 1400 mm sweep) with super enamelled copper wire of existing gauge to obtain the specified and satisfactory RPM as per manufacturers specification, including replacement of all insulation materials, varnishing heating, drying, assembling of stator & rotor, etc. and testing complete all as directed by Engineer-in-Charge.
Rewinding of the motor of exhaust fan of any make / type and size 300 mm / 380 mm sweep with super enamelled copper wire of existing gauge to obtain the specified and satisfactory RPM as per manufacturers specification, including replacement of all insulation materials, varnishing heating, drying, assembling of stator & rotor, etc. and testing complete all as directed by Engineer-in-Charge.
Rewinding of the motor of wall mounted fan of any make/type and of size up to 600 mm sweep with super enamelled copper wire of existing gauge to obtain the specified and satisfactory RPM as per manufacturers specification, including replacement of all insulation materials, varnishing heating, drying, assembling of stator & rotor, etc. and testing complete all as directed by Engineer-in-Charge.
Supply only shaft for ceiling fan of size 1200 mm / 1400 mm.
Supply only PVC holder stand for capacitor of ceiling fan 1200 mm / 1400 mm sweep.
Supply only ball bearing of any size and type suitable for any type / make / size of ceiling fan.
Supply only ball bearing of exhaust fan of any type/make and size (300 /380 mm sweep) .
Supply only capacitor 230 Volts AC 50 HZ and rated capacity 2.5 MFD for ceiling fan.
Supply only capacitor 230V AC 50 HZ and rated capacity 3.15 MFD for exhaust fan.
Supply only PVC insulated, sheathed twin twisted stranded copper conductor flexible cable of size 1.5 Sqmm.
Supply only gun metal bush of suitable size for exhaust fan of any type / size as per existing type.
S&F 'S' type MS hook and clamps MS rod of 300 mm long of 10 mm dia for hanging/fixing of ceiling fan including cemented work all as specified & directed.
Supply only MS anodized bolts with anodized nuts, spring washers split pin etc size 50 mm long 10 mm dia half threaded type with split pin hole for hanging of ceiling fan.
S&F down rod of suitable size including gromet/ reel type rubber pad with clamp & bolts, nuts and washers suitable for housing ceiling fan.
S&F in repairs louvers shutter made of MS sheet metal 1.2mm thick for round base and 0.8mm thick for flaps confirming of mounting edges frames made of MS Flat of size 25mmx3mm thick including heavy duty rust proof passivated bolts, of size 50mm long 8mm dia to be fixed on wall after drilling and duly painted by two coats of synthetic enamelled paint (spray painting) over a coat of primer for exhaust fans up to size 380 mm sweep.
Supply and fixing Metallic Fan Blade suitable for Exhaust fan of size 300 mm sweep all as directed.
Supply and fixing Metallic Fan Blade suitable for Exhaust fan of size 380 mm sweep all as directed.
Supply and fixing PVC canopy suitable for ceiling fan of any type / make / size for both end of down rod all as directed.
S&F in repairs of PVC plug top 5 Amps, 3 pin,230 volts complete all as directed. (Make:Anchor/Cona/Roma)
S&F in repairs of PVC plug top 15 Amps, 3 pin,230 volts complete all as directed. (Make:Anchor/Cona/Roma)
Supply and Replacement of incoming cable with 3-core,PVC Stranded copper conductor of sizes 2.5 sq.mm with taking down of old unserviceable incoming cables all as specified and directed, Make- Polycab or equivalent of Richa/Mescab/Gloster
Taking out unserviceable geyser of any make and capacity for necessary repair/replacement including refixing the same in original position after repair including one coat of white synthetic enamel paint including preparation of old disturbed surfaces with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as specified. (NOTE : spare parts shall be paid separately under supply only rate)
Supply and fixing PVC connection pipes inner wiremesh type 15mm size of length 450 mm for hot and cold with both ended brass flare nuts for geyser connection. (Make:Prayag/Marc/Jaquar)
Supply and fixing thermostat with auto cut for setting temperature 0- 90C.
Supply and fixing indicator lamp red/green colour with transparent covers.
Supply and fixing gun metal safety valve all as per existing size not less than 15 mm.
Supply and fixing heating element thread/push type as per existing size & shape of capacity 1.5 KW complete all as specified and directed including taking out of unserviceable one .
Supply and fixing heating element thread/push type as per existing size & shape of capacity 2.0 KW complete all as specified and directed including taking out of unserviceable one .
Supply and fixing geyser apparatus assembly for 25 ltrs capacity chromium coated as per existing size and shape including replacement of stud bolt, nut, washer etc. and rubber gasket complete all as directed.
Supply and fixing geyser apparatus assembly for 50 ltrs capacity chromium coated as per existing size and shape including replacement of stud bolt, nut, washer etc. and rubber gasket complete all as directed.
Repair to copper tank or capacity 25/50 ltrs capacity geyser of any make/type at rusted portion of the tank by gas welding/brazing with copper rod electrode including refixing of all other accessories and rubber gasket complete all as directed.
S&F Anchor bolts mild steel of sizes 8.0 mm x 100 mm for installations of Geyser of any make and capacity.
S&F Anchor bolts mild steel of sizes 10 mm x 100 mm for installations of Geyser of make and capacity.
Taking down carefully unscrewing from boards/outlet boxes, fittings and fixtures of flame proof fixtures such as junction/terminal box hose conduit pipe etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces and all as specified.
M&L point wiring for flame proof with FRLS type PVC insulated, unsheathed, 1100 Volts grade, with single core multistranded copper conductor 1.5 Sqmm (for phase and neutral) and 1.5 Sqmm for continuous earth wire drawn through and including ERW rigid stove enamelled steel conduit 20mm dia with fittings and accessories for one light point controlled by one I-way rotary switch including taking dwon old point wiring including all accessories complete all as specified and directed .(Make of wire: Finolex/Polycab/Plaza,Make of conduit:Tata/Jindal/Prakash)
S&F flame proof, weather proof, rotary switch with termination box in plain cover LM-6,16A,Single pole 250V including aluminium body enclosure with threaded cover and toggle action switch operated by a shrouded knob single pole,16 Amps with cable direct entries complete all as direct by Engineer-in-Charge. (Make- SUDHIR Cat part No. RI/0A/1010-2A or equivalent of Shyam/Baliga)
Supply and fixing flame proof junction box, two ways with spigotted cover LM-6 cable entry 25 mm dia hole aluminium constructed of any size and any type complete all as directed .(Make- SUDHIR, Cat No. JB/OOA/105-3 or equivalent of Shyaam/Baliga)
Supply and fixing flame proof threaded type junction box,Four ways with spigotted cover LM-6 cable entry 25 mm dia hole / M25, aluminium constructed of any size and any type complete all as directed .(Make- SUDHIR, Cat No. JB/153 or equivalent of Shyaam/Baliga)
Taking down unserviceable sub main /Sub circuit wiring for flame proof fittings of any type and size including conduit, batten wiring for necessary repair/replacement.
M&L sub main wiring with Two runs of single core PVC insulated, unsheathed, stranded copper conductor (FRLSH) cable 1100 Volts grade 4 Sqmm and One runs of FRLSH grade 4.0 Sqmm PVC insulated stranded copper conductor as earth wire drawn in and including ERW 25 mm dia stove enamelled steel rigid conduit (ISI mark ) with flame proof fittings & fixtures like bend, elbow, couplings, GI saddle clips etc and connecting up complete all as specified and directed. (NOTE :- Two runs of 4 Sqmm wire ,One run of 4.0 Sqmm wire with one run of ERW conduit shall be measured as one unit).(Make of wire: Havells/Polycab/Plaza Make of conduit:Tata/Jindal/Prakash)
M&L sub main wiring with 4 runs of single core PVC insulated, unsheathed, stranded copper conductor,4.0 Sqmm (FRLSH) cable 1100 Volts grade and 2 runs of FRLSH grade 4.0 Sqmm PVC insulated stranded copper conductor as earth wire drawn in and including ERW 25 mm dia stove enamelled steel rigid conduit (ISI mark ) with flame proof fittings & fixtures like bend, elbow, couplings, GI saddle clips etc and connecting up complete all as specified and directed. (NOTE :- four runs of 4 Sqmm wire , two run of 4.0 Sqmm wire with one run of ERW conduit shall be measured as one unit).(Make of wire: Havells/Polycab/Plaza Make of conduit:Tata/Jindal/Prakash)
S&F LED flameproof Tube light fixture suitable for T-8 tube of 1 x 16/20 Watt complete with all accessories duly prewired and including connecting up with twin core 1.5 Sqmm twisted flexible copper conductor cable of suitable size and recmmended for Gas/Vapor group of IIA & IIB and Zone 1 & 2. IP65 Protected including taking down old FTL flameproof fitting complete all as directed by Engr-in-charge. (Make: Crompton Cat No. EXTN1LT8-16/20 or equivalent of Shyaam/Bajaj).
S&F LED flameproof Tube light fixture suitable for T-8 tube of 2 x 16/20 Watt complete with all accessories duly prewired and including connecting up with twin core 1.5 Sqmm twisted flexible copper conductor cable of suitable size and recmmended for Gas/Vapor group of IIA & IIB and Zone 1 & 2. IP65 Protected including taking down old FTL flameproof fitting complete all as directed by Engr-in-charge. (Make: Crompton Cat No. EXTN2LT8-16/20 or equivalent of Shyaam/Bajaj).
S&F flame proof, weather proof flexible metallic hose conduit from junction box to tube light fitting of size M20/3/4" conduit M x M / FM x M / Fx F 300mm complete all as directed by Engineer-in-Charge.(Make: SUDHIR , Cat No- FH/199 or Equivalent of SHYAAM / BALIGA).
S&F flame proof, weather proof flexible metallic hose conduit from junction box to tube light fitting of size M20/3/4" conduit M x M / FM x M / Fx F 500mm complete all as directed by Engineer-in-Charge.(Make: SUDHIR , Cat No- FH/199 or Equivalent of SHYAAM / BALIGA).
S&F flame proof switch/socket and plug combined, LM-6 of capacity 32 Amps, 500 Volts, Three Phase (3P+Earth) with suitable entry for steel conduit and connecting up complete all as directed by Engineer-in-Charge. (Make : SUDHIR, cat part No SS/187 or equivalent of SHYAM/BALIGA ).
S&F flame Proof switch/socket and plug combined LM-6 of capacity 16 Amps, 250 Volts, Single Phase (2P+Earth) (horizontal pins) with suitable entry for steel conduit and connecting up complete all as directed by Engineer-in-Charge. (Make : SUDHIR, cat part No SS/OA/1010-1 or equivalent of SHYAM/BALIGA ).
S&F flame proof switch/socket and plug combined LM-6 of capacity 63 Amps, 500 Volts, three phase (3P+Earth) with suitable entry for steel conduit and connecting up complete all as directed by Engineer-in-Charge. (Make : Sudhir cat part No SS/214 or equivalent of SHYAM/BALIGA)
S&F in repairs air termination single pointed aluminium rod 12mm dia 300mm long fixed on GI pipe 40mm bore light grade 1.5mtr long or fixed to floor all as specified and directed by Engineer-in-Charge.
M&L in repairs test point terminal block made out of gun metal (or) phosphorus bronze size 75x75x25mm drilled and screwed with and including 3 Nos 8mm dia 25mm long hexagonal head screws complete all as directed by Engineer-in-Charge.
S&F in repairs Aluminium Lightning conductor/Strip of size 25 x 3.15 mm dia with saddles and fixing screws etc.for roof conductors and down conductors fixed to wall or batten or recess or chases or drawn in conduit/pipe or fixed to poles or any other indicated situations above the ground etc.all asspecified and directed .
M&L Earthing with galvanized steel pipe electrode, 40 mm bore,medium grade, 2.5 mtrs length buried directly in ground preferable vertically in ground with top edge not less than 1.25 meters deep below normal ground level connected to galvanised iron Strip of size 25x 4.0 mm as earth lead by means of bolts, nuts, check nuts and washers etc, GI earth lead strip duly protected by 40 MM dia GI pipe (light grade) and connected to control switch as directed including necessary earth work in soft/loose soil and disposal of soil to a distance not exceeding 50 Mtrs, PCC (1:3: 6) type C1 as in concrete pit,50mm thick precast RCC (1:1.5:3) type A1 as in cover slab duly reinforced with 8 mm dia TMT bar @ 100 mm c/c both way and two nos lifting handle made cut of 10 mm dia TMT bar and set in cement mortar (1:4),funnel,charcoal and salt,in alternate layer,testing etc complete and as specified in electrical plate No 2 of SSR part-I including taking down old earthing pit.
M&L Earthing with galvanized steel earth plate electrode of size 60cm x 60cm x 6 mm thick,buried directly in ground(earth pit not less than 2.25 meters deep below ground Level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanised ironStrip of size 25x 4.0 mm as earth lead by means of bolts, nuts, check nuts and washers etc, GI earth lead strip duly protected by 20 MM dia GI pipe (light grade) and 20 MM GI pipe (medium grade) for watering and connected to control switch as directed including necessary earth work in soft/loose soil and disposal of soil to a distance not exceeding 50 Mtrs, PCC (1:3: 6) type C1 as in concrete pit,50mm thick precast RCC (1:1.5:3) type A1 as in cover slab duly reinforced with 8 mm dia TMT bar @ 100 mm c/c both way and two nos lifting handle made cut of 10 mm dia TMT bar and set in cement mortar (1:4),funnel,and salt,in alternate layer,testing etc complete and as specified in electrical plate No 3 of SSR part-I including taking down old earthing pit.
S&F in repairs Earth Continuity conductor or main earthingstrip fixed to wall or batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situations for earthing etc. as required 25x 4.0 mm dia galvanized iron strip or steel wire .
RPL SYNDICATE CO
J B NATH AND SON
Rounaq Enterprise
Shree Mahavir Associates
KRISHNA ENTERPRISES
M/SNeelachal Enterprises
BHARUKA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .