Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.1 LAccepted-AOC HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹46.7 L+₹33,790.10 (0.73%)Rejected-AOC I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | L2 | Rejected-AOC OTHER THAN L1 BIDDER | |
| 3 | L3₹46.8 L+₹42,399.20 (0.91%)Rejected-AOC | L3 | Rejected-AOC OTHER THAN L1 BIDDER | |
| 4 | L4₹48.6 L+₹2.2 L (4.75%)Rejected-AOC 201 GANAPATI SANKUL AGASHIVNAGAR MALKAPUR KARAD SATARA MAHARASHTRA 415539 | SATARA | MAHARASHTRA | 415539 | L4 | Rejected-AOC OTHER THAN L1 BIDDER | |
| 5 | L5₹49.3 L+₹2.9 L (6.35%)Rejected-AOC | L5 | Rejected-AOC OTHER THAN L1 BIDDER |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
27 Jun 2020, 6:00 pmClosed
GE SATWARI
GE SATWARI
PROVN OF INSTALLATION OF 150 KVA 3PH TRANSFORMER, SPL REPAIR TO OT CORRIDOR,SUMMER APPLIANCES AND CERTAIN OTHER WORKS UNDER GE SATWARI
2020_MES_347457_1
GEJM-48/20-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE SATWARI
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE SATWARI
₹96,000
Yes
7 Aug 2020
30 May 2020
29 Jun 2020
30 May 2020
27 Jun 2020
13 Jun 2020
Amount
Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 m depth for foundation laying of cable ect or for shaft wells cesspits manholes per holes etc 10sqmm on plan and n.exe 1.5m in depth and getting out in any type of soil .complete all as sepecified dirceted by engr-in-charge.
All as per item No 1 above but exceeding 1.5 mtr and not exceeding 3 mtr depth..complete all as sepecified dirceted by engr-in-charge.
Returning, filling in incl. spreading, leveling, watering and well ramming in layers not exc. 25 cm thick in any type of soil complete all as specified and directed by Engineer-in-charge.
Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point. .complete all as sepecified dirceted by engr-in-charge.
Supply and spreading sand Dry cushioning to cable providing with a layer of sand 8cm deep before laying the cable and 15cm deep after laying and stretching the cable in trenches complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying dry bricks over cable laid in trenches as mechanical protection to cable with width equal to the length of bricks with well burnt sub class 'B' bricks complete all as specified
M&L cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate for foundation of pole/stay/strut etc complete all as specified.
M & L cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for pole pedestal (PCC) including necessary form work etc complete all as specified.
Plain cement concrete M-15(Nominal Mix) using 20 mm graded crushed stone aggregate in PCC block complete all as specified and as directed by Engineer-In-Charge.
Material and labour for plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in floors,foundations filling and mass concrete.complete and all as specified directed by engr-in-charge.
Brick work with old size brick curved or straight on plan exceeding 6m area radius built in CM 1.6 bricks crushing strength not less than 75 kg/square cm.complete and all as specified directed by engr-in-charge.
Material and labour rendering 15mm thick on fair of brick surface in cement mortar 1:4 finished even and fair complete all as specified.
M&L for preparing newly plastered surfaces of wall and applying two coats of cement base paint over a coat of white wash.complete and all as specified directed by engr-in-charge.
M&L hardcore of broken stone of gauge exc 63mm & n.exc 100mm deposited spread and leveled in layers n.exc 15cm thick watered and well rammed to a true surface. complete and all as specified directed by engr-in-charge..
M&L for PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate as in sub base of floor 75mm thick finished even and fair without using extra cement.complete and all as specified directed by engr-in-charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing surface with neat cement slurry with 3.0 kg of cement per sq. metre, removing serviceable tiles to store and rubbish off the Cantt area complete all as directed
Taking down cement plaster of any description on brick or stone walls or from concrete surface including raking out joints, hacking for key, scrubbing down with water etc, and removing unserviceable material outside cantt area, complete all as specified.
Refixing shutter of any desciption exc 1.00 Sqm and n exc 2.00 sqm each in same opening etc complete all as specified and as directed.
Refixing shutter of any desciption exc 2.00 Sqm and n exc 4.00 sqm each in same opening etc complete all as specified and as directed.
Taking down chowkats or frames with shutter (Aluminium door) (without taking off shutter from the frame) exc 1.5 Sqm & n.exc 4 Sqm each including cutting holes for taking out hold fast or dismantling brick work and removing from site all as specified.
Material and labour Vitrified Ceramic(Double Charged) edge cut joint free coloured or printed any shade tiles 10 mm thick (square/ rectangular) polished area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm , in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match and set in neat cement slurry and pointed with coloured/white cement to match over 15 mm thick screed bed in CM 1:4 complete all as specified and as directed by Engr-In-Charge. Make Somany, Kajaria (Sample as approved & Kept in GE's sample room)
Description all as item No 21 but as in vertical surfaces dado/ skirting over a backing coat of CM 1:4, 10 mm thick complete all as specified and as directed by Engineer-in-charge. Make Somany, Kajaria (Sample as approved & Kept in GE's sample room)
Material and labour glazed ceramic coloured Digital tiles in vertical surface 300x450x7 mm thick, set and jointed in neat cement slurry and pointed white or colored cement to match the surface over 10 mm thick CM 1:4 complete all as specified and as directed by Engineer-in-charge. Make Somany, Kajaria (Sample as approved & Kept in GE's sample room)
Supply and fixing 4mm thick aluminium composite panel (coloured sheet) and in additional other accessories for fitting complete all as specified by Engr-in-Charge.
Supply and fixing in repair double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and as directed.
S&F in repair Brass Mortice lock with brass handles and fittings , 4 lever vertical type, size 100 mm including complete accessories complete all as specified. Make:- Links Locks/ Godrej
Rendering 15mm thick on fair faces of brick or concrete surface walls, in cement mortar 1:6 , rendering is to be finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
Material and labour for preparation of new plastered surfaces of walls & applying two coats of oil bound distemper over two coat of wall care putty of less than 2 mm thick and one coat of primer complete all as specified.
M&L for preparation of old decorated concrete/ plastered surfaces of walls, Pillars, cornices etc by booming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots & rubbing with sand paper and applying two coat of oil bound distemper on old decorated wall surface including two coats of wall care putty of less than 2 mm thick on uneven surface as and where required.
Supply,installed , testing and commissioning outdoor type,step down transformer 11000/433 volts (at no load) AC, 3 phase 50 Hz capacity 160 KVA, core type, double copper wound,oil immersed,naturally cooled,oil natural, Air natural (ONAN) with external cooling fins, delta connected on primary side (HV) star connected on secondary side (LV) in accordance with vector symbol, DYN 11 (vector group) with neutral brought out on secondary side (LV side) and having tapping at + 2.5% to +7.5% HV side to be changed by means of hand operated off load tap change gear. The maximum temperature rise should not exceed 45 degree celcius in oil and 55 degree celcius in HV.LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celcius. The transformer shall be IS:1180 Part-1:2014 (Level-II) and BEE Certified and shall comprise of the followings:- (a) 03 Nos porcelain bushing with arcing horn on HV side suitable for 11 KV complete withbushing,copper rods, nuts and washers. (b) One cable box on LT side ( Secondary side) consisting of four Nos porcelain bushing with copper rods, complete with nuts and washers, with two Nos cable gland suitable for reception/taking out of XLPE insulated heavy duty armoured cable including gland, joint and jointing materials complete. (c ) Oil conservator with filter type frain valve and oil level gauge. (d) De- hydrating breather with first fill dehydrating agent (silica gel). (e) Explosive vent.
(f) Thermometer pocket on tank cover. (g) One Nos 100 mm dia, dial type thermometer , vapor pressure type, having range 0 - 120 degree celsius with metal guard having maximum perimeter reading temperature indicator with resisting device for transformer. (h) Two earthing terminals on tank cover to facilitate fixing of 32 X 6 mm galvanised iron earth strip for earthing of neutral & body. (i) Rating plate and terminal making plate. (j) Oil level gauge. (k) Oil drain/ fillter valve. (l) Lifting lugs. (m) Oil filling hole with cap/plug with connecting plate complete. (n) Air release valve plug. (o) Four plain solid cast steel detachable rollers. (p) Extra bushing for neutral , outside the LT cable box for providing independent earthing for neutral. (q) First filling of new and unused transformer oil IS-35/93 (fourth revision) marked (Make - savita/Power Oil) filtered and tested up to 40 KV dielectric strength at 2.5 mm air gap between testing Note:- (i) Certificate of dielectric strength shall be submitted by the contractor after filling the oil.
Supply and fix HT XLPE insulated AB cable 3-core X 95 sq mm + 1 x 70 sq mm all as specified directed by engr-in-charge.
S&F outdoor type cable end termination jointing kit heat shrinkable complete with all accessories and jointing materials suitable mounting on channel/angle iron for HT ABC cable 3 core x 95 sqmm + 1 x 70 sqmm (kit shall be not older than 3 months from the date of manufacture) complete all as specified and directed
Supply laying & testing in replacement of XLPE insulated, Armoured, electric cable heavy duty with alumimium conductor 11000 volt (E) grade of size 95 Sqmm x 3 core.
S&F outdoor type cable end termination jointing kit heat shrinkable complete with all accessories and jointing materials suitable mounting on channel/angle iron for 3 core 70 to 120 Sqmm XLPE HT cable (kit shall be not older than 3 months from the date of manufacture) complete all as specified and directed.
Material & labour for HDPE pipe of size 40 mm dia grade PE 63 rating PN 10 suitable for protection of strip complete all as specified.
Supply & Errecting in truelly vertical position steel tubular swaged poles complete with CI base plate, finial taper plug bolts, nuts & screws 11 mtr long type 410 SP-55 complete all as specified and directed by engr-in-charge. and Painting to new steel tubular pole HT with two coat of paint synthetic enamel in 30cm strips alternate layers with black & white colour upto 1.5 mtr length from GL complete all as specified.and marking Nos on pole all as specified and directed by Engg in Charge
Supply and fixing in replacement of galvanized steel stay assembly complete with stay rod 20mm dia including stay strand 7/4 mm fixed for stay of poles including necessary MS clamp of 50x6mm flat iron nuts and bolts, loop insulators complete all as specified and directed by Engr-in-Charge. Note:- Earth work, PCC shall be measured and paid separately.
Standard cable route indicator 10 cm dia, CI plate 6 mm thick embossed with raised lettering HT cable 11000 volts painted with luminous paint and mounted on angle iron 25x25x3mm and 0.6 mtr long embedded in PCC block 1:2:4 (size 30 cm x 15 cm x 15 cm) type B-1 using 20mm graded stone aggregate complete all as specified
M & L cross arms bracing support clamps, back plate etc fabricated from structural steel section with bolts, nuts, washers,welding, bending cold or hot,drilling holes for bolts in any shape and size as directed or indicated and painted with one coat of red oxide and two coats of aluminium paints complete all as sepecified dirceted by engr-in-charge.
Anti climbing device, spikes type, fabricated out of MS bars (round, square or flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the poles, spike welded to flat iron, including on primer coat, one under coat and two finishing coats of silver aluminium paint including preparation of surfaces complete all as sepecified directed by engr-in-charge.
Supply & fixing danger notice plate 250 mm x 200 mm made of mild steel sheet 1.6mm thick & vitreous enamelled white on both sides and with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for HT 11 KV as required.complete and all as specified directed by engr-in-charge.
Supply & fixing danger notice plate 200 mm x 150 mm made of mild steel sheet 1.6mm thick & vitreous enamelled white on both sides and with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for LT 440 Volts as required..complete all as sepecified directed by engr-in-charge.
S & Install,including replacement of Air break, gang operated switch with 15 Nos insulators, outdoor type pole, mechanically operated, suitable for vertical operations, single break, provided with locking arrangement (including 50mm Godrej lock with two keys) mounted on and including steel frame and HT post type insulators copper alloy, high pressure, with operating mechanism having operating rod of 20 mm dia GI pipe (medium grade) operating from 1.2m above GL complete including drop out fuses conforming to IS-1318 of 1972, rated voltage 11 KV and for current rating 400 Amp all as specified.
Lightning arrestors (set of three), expulsion type, HT metal oxide surge arrestor polymeric type, complete with all fittings, transmission class rated voltage 125 KV contionous operating voltage at 8/20 impulse, 75 KV discharge capacity 65 Kilo amp suitable for 11000 volts complete all as specified and directed
M& L For Earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx6 mm thick buried directly in ground to a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by 15 cm thick packed layer of charcoal and common salt and connected with and including GI strip of size 32 x 6 mm by means of bolts, nuts, check nuts and washers of GI 40 mm bore GI pipe light grade from earth plate up to testing point for protection of GI strip and 20 mm bore GI pipe (light grade) with wire mesh and funnel for watering including necessary excavation and earth work, (in any type of soil) PCC chamber (1:3:6) type C-2 with RCC cover with complete all as shown in electrical plate No 3 of MES schedule Part I of SSR Part-I 1991 complete all as specified Note : (i) RCC pit cover shall be precast of RCC (1:2:4) type B-1, 80 mm thick, reinforcement with 8 mm tor steel in lieu of CI cover and the rate includes in the unit rate of item (ii) Earth electrode shall be projected upto test pit using necessary arrangement with suitable size GI pipe and the rate in the unit rate of item (iii) RCC cover shall be painted with red paint over a primer coat and the rate includes in the unit rate of item
M&L For Earthing complete with galvanized steel earth plate electrode 60 cm x60cmX6 mm thick buried directly in ground to a depth not less than 3 mtr below normal ground level with top edge of earth plate at a depth not less than 2.40 mtr below ground level, earth plate surrounded by 15 cm thick packed layer of charcoal and common salt and connected with and including GI wire of size 4 mm by means of bolts, nuts, check nuts and washers of GI connected to MCB DB/LT panel 15mm bore of GI pipe (light grade) from earth plate up to testing point for protection of GI wire and 40 mm bore GI pipe (light grade) with wire mesh and funnel for watering including necessary excavation and earth work, (in any type of soil) PCC chamber (1:3:6) type C-2 with RCC cover with suitable size of handle made out of 8mm dia MS bars and angle iron 40 x 40x 3mm frame for cover complete all as shown in electrical plate No 3 of MES schedule Part I of SSR Part-I 2009 complete all as specified Note : (i) RCC pit cover shall be precast of RXX (1:2:4) type B-1, 80 mm thick, reinforcement with 8 mm tor steel in lieu of CI cover and the rate includes in the unit rate of item (ii) Earth electrode shall be projected upto test pit using necessary arrangement with suitable size GI pipe and the rate in the unit rate of item (iii) RCC cover shall be painted with red paint over a primer coat and the rate include in the unit rate of item
GI strip 32 x 6mm as earth continuity conductor for loop earthing complete with fixing of seddles, nuts bolts, washers, secrews complete all as specified and directed.
Aluminium strip 25 x 3.15 mm for connecting earthing to LA and GODs on poles including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed by Engineer-in- Charge.
LT XLPE insulated, armoured, heavy duty electric aluminium conductor, PVC sheathed galvanized steel strip or wire, armoured electric power cables, with aluminium stranded conductor 1100 volts grade, cross sectional area, 120 Sqmm, 3.5 core laid in trenches/road crossing/under floor / on walls/ on poles including testing complete all as sepecified dirceted by engr-in-charge.
Dismentaling, taking down unserviceable feeder pillar and Supply, installation, testing & commissioning in renewal of totally enclosed feeder pillar outdoor type fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type (independent cabin including locking arrangement for each MCCBs, bus bar chamber enclosed complete suitable for operating on 415 Volt 50 Hz AC supply internally wired with copper conductor having legs 90 cms made out of 50x50x6 mm angle iron grouted on brick masonary platform upto 45 cms. Brick masonary platform should be 60 cms above the Ground Level. Comprising the following:- Note:- (i) The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar. (ii) Fabrication of feeder pillar box to be approved by CPRI width of the panel not less than 75 cms. (iii) Cost for construction of platform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate), deemed to be included in the item rate. No Extra payment will be made. (iv) MCCB's should be connected with extensions terminals at both side (incoming and outgoing).
INCOMING (a) MCCB 320 Amp 4 pole 36 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Makes: Legrand(DPX^3) Cat No.422006 or equivalent to Schneider(NSX)/Siemens(3VL) - 01 No as incoming BUS BAR (a) 01 set of 500 Amps TPN aluminium bus bar of suitable length and of crossection as per design with colour codding. Bus bars shall be designed to with stand a fault level of 36 KA at 415 volts. OUTGOING (a) MCCB 4 pole 250 Amp, 36 KA with thermal and magnetic release with Ics=100% Icu conferming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and overload protection:12 IN Make:- Legrand Cat No. 420249 or equivalent make of SIEMENS(3VL) - 02 Nos as outgoing (b) MCCB 100 Amp 3 pole 16 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Makes: Legrand(DPX^3) Cat No.420005 or equivalent to Schneider(NSX)/Siemens(3VL) - 01 Nos as outgoing
M&L for Framed work of steel structure GDE Fe410-0 or Fe 310-Oas in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled or weilded for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete and all as specified directed by engr-in-charge.
S&F chainlink fencing pvc coated green colored 4mm dia galvanised steel wire, 150x100mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling complete all as specified and directed by engr-in-charge.
Material and labour for ENDURA CITYLINER NEO 60W LED IP66 new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaire with high power LED as light source including electronic driver 60W LED 6000k. Havells cat no:- LHETAXU7PN6JO60 OR equivalent in philips/C&G.complete and all as specified directed by engr-in-charge.
Material and labour for JETA 50 NEW LED IP65 Energy saving IP65 flood light luminaire with high power COB LED as light source. including electronic driver 45W LED 5000k. Havells cat no:- LHEPCZUEIN6W030 OR equivalent in PHILIPS/CROMPTON GREAVES
Supply & laying GI pipe light grade 80mm bore under road, path or along poles as cable protection complete and all as specified directed by engr-in-charge.
Supply & laying GI pipe light grade 40mm bore under road, path or along poles as cable protection complete and all as specified directed by engr-in-charge.
S&F street light bracket made out of 40mm dia GI pipe light grade of length up to 1.2mtr as required bent to shape required with and including 2 nos 50x6mm Msflat iron clamps complete all as specified and directed.
Supply, installation, testing & commissioning of invertor type air cooled split unit air conditioner electric driven AC 230 V, 50 Hz single phase of capacity 1.5 TR, BEE minimum 3 Star rated with cooling and intelligent heating facility incl its fixing accessories with fwg specification: Rated cooling capacity: 18000 Btu/Hr,Rated Current cooling: 7.8 Amp, Rated heating capacity: 18000 Btu/Hr, Copressor type: High EER twin Rotary, Anti dust/Anti-bacterial Filter, Dehumidifier, Refrigerant gas: R32, Operation: LCD Remote with self dignosis facility all as specified and directed. Make: Voltas, Model: 183 VH SZS or its equivalent in Hitachi Cat No RAU018IUEA, Carrier. Note: Rate includes powder coated stand (bracket) for fixing of outdoor unit.
Supply, installation, testing and commissioning of window type room air conditioner electric driven AC 230 V, 50 Hz single phase of capacity 1.5 TR (4500 K Cal per Hr) min BEE 3 Star rated with cooling and intelligent heating facility incl grill/wood cutting, extra copper wire, stand & other accessories, with fwg specification: Anti-bacterial/Dust Filter, Dehumidifier, Refrigerant gas: R22/ R32,Operation: LCD Remote with self dignosis facility all as specified and directed. Make: Hitachi Cat No- RAW118KYH or its equivalent in Voltas, Carrier. Note- for item No 63 & 64 rate includes lowering and disconnection of electrical connection of existing AC any type and depositing in store yard.
Supply and fix water cooler electric driven (single phase), having storage capacity of 40 Ltrs and nominal cooling capacity 40 Ltrs per hours with fwg specification: Fully Stainless steel (FSS) water tank,trough and faucet. Partial Stainless steel (PSS): Pre coated outer body for better corrosion resistance. Plastic parts that come in contact with water atr food grade quality. No of cold water tap: 01, Refrigerant: R-134a, Compressor: Hermetic type with suction gas cooled motor, equiped with overload protector, Themostat: Automatic controls tempratures, Power supply: AC 230 V +/- 10%, 50 Hz, single phase. Make: Voltas/ Blue Star/
M&L for framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including, bending and welding angles, as necessary, gusset plates, riveting, etc n exc 10 kg each brackets, confirming to Fe. 290. Gde-E-165 for making stand of desert cooler/AC (window type) all as specifed and directed.
S&F SRCD DBOX socket residual current device with steel enclosures, powder coated with socket and MCB SPN 20 Amp and make flush with wall all as specifed and directed. Make:Havells Cat No: DHDDCDP025202003 or its equivalent in Indoasin, Legrand, Crompton.
S&F in replacement sub main wiring with two single core PVC insulated,unsheathed, stranded copper conductor cable 4 Sqmm with 2.5 Sqmm PVC insulated, unsheathed, stranded copper conductor cable as earth wire in and including rigid PVC consealed conduit 20mm dia or higher, medium grade ISI marked and earth wire connected to common earth point all as specified & directed.
Supply, installation, testing, commissioning of high mast complete motorized alongwith wiring from MCB to flood light fittings, foundation, excavation, return filling, RCC/PCC including form work, foundation bolts, nuts, washers, anchor plate and template etc as per following specifications :- (a) General specifications (i) Height of mast - 16 mtrs, (ii) Material of construction : BS EN 10025/IS 2062, (iii) Thickness of material - Top section 3mm, bottom section 4mm, (iv) Cross section of mast (number of sides)-20 sided polygon, (v) Length of individual section - Top sec : 8.35 mtrs, Bottom sec : 8.35mtrs, (vi) Diameter - Base dia : 460mm, top dia : 150mm, (vii) Types of joints - stress slip fit joints. (viii) Length of overlap-1.5 times the dia of intersection, (ix) Metal protection treatment - Hot dip galvanised as per IS 4759/IS 2629, (x) Thickness of galvanisation - average 70 microns, (xi) Size of door opening at base of mast - 1200mmx 300mm, (xii) Types of locking on door panel - Close fitting door with allen key locking with suitable reinforcement to avoid buckling at base of mast. (xiii) Lightening protection finial - GI single spike of length 1200mm, (xiv) Size of base plate - Dia : 670mm, Thickness : 30mm, (b) Dynamic loading as prevailing at site (i) Max wind speed : 180 Km/hr, (ii) Number of foundation bolts - 08 Nos, (iii) PCD of foundation bolts - 590mm,(iv) Dia of foundation bolts - M30, (v) Length of foundation bolts - 850mm (c) Lantern Carriage (i) Material of construction - 40 NB /ERW CKASS B-MS PIPE, (ii) Dia of lantern carriage ring-800mm (ID), (iii) Construction - 8 arms welded, (iv) Number of joints - 2 segments, (v) Load carrying capacity - 16 luminaries, symmerical
(d) Winch : (i) Number of drums per winch- double drum, (ii) Gear Ratio - 50:1, (iii) Capacity - SWL750 Kgs, (iv) Method of operation - Motor or manual, (v) Lubrication arrangements - Self Lubricating in permanent oil bath, (vi) Type of lubricant - SAE 90/140 (e) Stainless steel wire rope (i) Grade - AISI 316, (ii) Dia of SS rope - 6mm, (iii) Construction of SS Rope - 7/19, (iv) Number of SS Ropes - 03 Nos of 6mm for lantern carriage, 02 Nos of 6mm for double drum winch, (v) Thimbles and terminals - Provided, (vi) Breaking load capacity - 2350 Kgs per SS wire rope. (f) Trailing cable (i) Type - Flexible copper 5 core 2.5 sqmm FRLSH 02 Nos, (ii) Material - EPR insulated PCP sheathed/PVC, (iii) Make - IS approved, (iv) No of circuits per mast - Two (g) Power tool (i) Model - Integral, (ii) Capacity (HP) - 1.5 HP, (iii) Number of speed - Single speed, (iv) Reversible / non reversible - Reversible, (v) Input supply - 415 Volts/240 Volts, (vi) Torque limitor - Withmechanical trippping facility. (h) Aviation light :-LED aviation light 6W luminaries integral LED light comprising of polycarbonate enclosure alongwith suitable fixing arrangements with rolled steel equal angle of 25 x 25 mm for making structure suitable for aviation obstruction light including welding, bending cold/hot drilled holes for nuts, bolts and washers of any shape or size as required base all as speficied and directed by Engr-in-Charge. Make Philips/Bajaj /Jaquar/Halonix Note :- Cost of Excavation, return filling, PCC/RCC inclduing form work, foundation bolts, nuts, washers, anchor plate, and template all as per manufacture drawing complete all as specified and directed and no extra cost will be deemed to be included in the item rate and no extra will be paid to the contractor.
Supply, laying and testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured, heavy duty electric cable with aluminum conductor, LT 1100 Volts grade, cross section area 10 Sqmm x 4 core laid in trenches complete all as specified and as directed by the Engineer-in-Charge
Material and labour for SECURE 200W LED rectangular LED flood light with innovative thermal management and available with multiple optics and equipped with IP 66 protection. Make :- Cromption cat part No LSFO-200-CDL/60 or equivalent in Philips/Havells/Jaquar
Supply, installation, testing & commissioning of totally enclosed feeder pillar outdoor type fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type (independent cabin including locking arrangement for each MCCBs, bus bar chamber enclosed complete suitable for operating on 415 Volt 50 Hz AC supply internally wired with copper conductor having legs 75 cms made out of 40x40x4 mm angle iron grouted on brick masonary platform upto 30 cms. Brick masonary platform should be 60 cms above the Ground Level. Comprising the following:- .Note:- (i) The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar. (ii) Fabrication of feeder pillar box to be approved by CPRI width of the panel not less than 45 cms. (iii) Cost for construction of platform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate), deemed to be included in the item rate. No Extra payment will be made. (iv) MCB's should be connected with extensions terminals at both side (incoming and outgoing).
Aluminium strip 25 x 3.15 mm for connecting earthing to LA and GODs on poles including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed by Engineer-in- Charge.
Supply and Fixing in replacement of LED Street Light 45W 6000K in aluminium pressure die cast housing with toughned glass cover (IP-66 rating) with high power LEDs as light source including electronic LED driver and 10 KV external SPD. Jaquar Cat Part No LSRT01S045XC and equivalent make of Havells/Wipro/ Philips
Supply and Fixing in replacement of LED Street Light 60W 6000K in aluminium pressure die cast housing with toughned glass cover (IP-66 rating) with high power LEDs as light source including electronic LED driver and 10 KV external SPD. Jaquar Cat Part No LSRT01S060XC and equivalent make of Havells/Wipro/ Philips
Supply and fixing Flood light fitting LED type 120 Watt New generation energy saving & environmental friendly long life pressure die cast housing with lens (IP-65 rating) with high power LEDs as light source and electronic driver 120 W LED 6000K complete all as directed. Make:- Jaquar Cat Part No LFLD02S0120XC and equivalent of Phillips / Wipro all as specified and as directed by EIC.
S&F in PVC wire with two run single core PVC insulated cable copper conductor 1.5 sqmm and 1.5 sqmm for earthing from looping box to street light fitting terminal complete with thimbles all as specified and directed by Engg-in-charge.
Air termination single pointed aluminium rod 12 mm dia and 300mm long fixed with 40mm dia, 4 mtr long GI Pipe incl providing flat iron clamps, nuts & bolts, embedding the GI pipe in PCC M-10 block (nominal mix) of size 30 x 30 x 40cm and connecting complete all as specified directed by Engr-in-charge. Note: GI pipe,and Pcc will be measured and paid separately.
GI tubing (light grade) 40mm dia for holding of air termination rod.
Aluminium strip 25 x 3.15 mm with saddle on min distance of 0.5 mtr through out the aluminium strip and PCC blocks and fixing screws etc for roof conductors and down conductors above ground, Structural steel work as in cross arms, bracings, supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed by Engineer-in- Charge.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3nos 8mm dia 25mm long hex head screw.
Supply and fixing GI wire 4 mm dia for interlinking the air terminals
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4 core all as specified and directed.
Supply & laying PVC insulated, PVC sheathed cable with stranded copper conductor of size 1.5 sq mm 2 core sheathed 1100 Volts grade all as specified and directed.
Supply and installation LT feeder pillar box of suitable size 0.25 M x 0.30 M and 0.15 M deep minimum size cubical outdoor type having bus bar chamber with suitable Al bus bar 100 amps rating-04 Nos suitable for pole mounting 415 volts three phase 4 wire 50 HZ AC supply system all as specified and directed complete. Note:The box shall be dust and vermin proof IP-65 class protection made otu of 3.15 mm thick sheet steel and angle iron 20x20x5 mm front openable incl locking arrangement all as specified and directed. Make: Jaima, Electricfield, Powercontrol.
Supply and fix steel tubular swaged poles type 410 SP-22 (8.5 meter long) (having hole at top end and bottom end for cable passing( complete with CI base plate and finial including foundation and coping all as specified and directed. Note: PCC, excavation and earth work should be measured and paid separately under relevent items.
Supply and fix LED Street light fitting 45 Watt New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium housing IP66 protection and impact resistance roadway luminaire with high power LEDs as light source and electronic driver 45 W LED incl GI bracket of length not less than 1.2 mtr with 02 Nos clamp for fixing with pole incl nuts, bolts washer and connection wire all as specified and directed. Make : C&S Cat No LTESS 18x2.5 HPLED or equivalent in Crompron Greaves/Philips
M & L for point wiring One light/fan/bell point controlled by one, one way switch piano type 5 Amp with 1.5 sqmm (Nominal Area) FR-LS PVC insulated sheathed multistranded copper conductor, 1100 Volts grade through PVC conduit medium duty (ISI Marked) concealed with accessories such as bends, cross, elbow, tees etc. of suitable size including MS pressed steel cadmium plated terminal box not less than 1.6 mm thick for mounting Modular type switches, sockets, fan regulators etc and 3 mm thick laminated sheet top cover (ISI marked) including continuous earth wire FR-LS PVC insulated unsheathed 1.5 Sq mm(nominal area) copper conductor multistarnded, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified for the following
Description all as item No 90 but One 3 pin 5 Amps socket outlet on same board controlled by one, one way 5 Amps piano switch.
Description all as item No 90 but One 3 pin socket outlet on independent Board controlled by one one way piano switch 5 Amp
M & L for point wiring with 2.5 sqmm (Nominal Area) FR-LS PVC insulated sheathed multi stranded copper conductor, 1100 Volts grade for 3 Pin socket outlet 15 Amps on independent board through MS conduit medium duty (ISI Marked) concealed with accessories such as elbow, tees,internal & external bend etc. of suitable size including MS pressed steel cadmium plated terminal box of 1.6 mm thick for mounting switch socket combination and 3 mm thick ISI marked laminated sheet top cover including continuous earth wire FR-LS PVC insulated 2.5 Sq mm copper multi stranded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified.
Supply and fix modular switch 6 Amps, 1 module complete
Supply and fix modular switch 16 Amps, 1 module complete
Supply and fix modular socket out 6 Amps, 2 module complete
Supply and fix modular socket out 16 Amps, 2 module complete
S&F stepped type electronic fan regulator flush modular type all as specified and directed.
S&F ceiling rose PVC/Polycorbonate surface bakelite 65x50 mm having three terminals complete.
S&F ceiling fan 1200 mm sweep 3 blade, opal white, AC 230 volts single phase incl connecting from ceiling rose/ connector with suitable size flexible copper conductor PVC insulated seathed cord complete. Make: Crompton/ Bajaj/ Havells
S&F desert cooler electric driven (single phase), having nominal air flow capacity of 4000 CuM per hour (or nearest size), (GI sheet body) with suitable size flexible copper conductor PVC insulated seathed cord complete. Make: Crompton/ Usha/ khaitan
S&F batten holder PVC/Polycarbonate insulated body with back plate suitable for batten fitting including LED buld of 15 watt all as specified and directed.
S&F E-lite LED 18 watt tube light fitting with tube rod including its connection with 2 core flexible copper conductor cable with suitable size complete with all accessories all as specified & directed.Make: Cromton/ Havells/ Philips
S&F sheet metal enclousure for MCB DB single pole and neutral 8 way with 200 Amps rated bus bar 240 volts double door type.
S&F MCB single pole 240V AC 6 to 32 Amps 'C' seried all as specified & directed. Make: Indoasian/ Legrand/ HPL
S&F MCB single pole & neutral 240V AC 32 Amps 'C' series all as specified & directed.
S&F 1100 volt grade heavy duty cable PVC insulated aluminium conductor, served with innerseathing of PVC tape and overall PVC seathed in service of PVC seathed in service connections sus-pended by insulating hangers not more than 1metre apart including 4 mm suspension wire one twin core cable flat or circular of size 10 sq mm 2 core multistranded all as specified and directed
SATISH AND CO
M/S S K Electricals Regd
Prakash Trading Corporation
CELMAC REGD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .