Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LAccepted-AOC THIRU R KRISHNAMURTHY CONTRACTOR NO 5 864 MARIAMMAN KOIL STREET KULLAPALAYAM PERIYABUSAMUTHIRAM POST PUDUCHERRY 605 102 | VILLUPURAM | TAMIL NADU | 605102 | L1 | Accepted-AOC LOWEST TENDERER | |
| 2 | Rejected-Technical | - | Rejected-Technical L2 |
Tender Value
₹7.3 L
EMD Value
₹14,510
Closing Date
7 Mar 2022, 3:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Commissioner, OM
II cross, Jawahar Nagar Puducherry-5
Improvements to the Karumathi shed including construction of bathroom at Pakkamudayanpet in Thattanchavady Constituency.
2022_DLA_9435_1
OM/e-tenders/564/2021-22
Open Tender
Civil Works
Works
120 days
THATTANCHAVADY
Please refer Tender documents
3 documents required · 3 mandatory
₹525
₹14,510
3 Nov 2022
1 Mar 2022
7 Mar 2022
1 Mar 2022
7 Mar 2022
1 Mar 2022
90 days
Amount
CODE NO. 2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms , lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed , within a lead of 50m -All kinds of soil.
CODE NO.2.27A.1 Supplying and filling with gravel (excluding rock) in trenches , plinth, sides of foundations etc . In layers not exceeding 20 cm in depth consolidating each deposited layers by ramming and watering etc .complete including all lead and lift
CODE NO: 4.1.10 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size)
CODE NO.5.1.3 Providing and laying in position specified grade of reinforced cement concrete , excluding the cost of centering , shuttering , finsishing and reinforcement - All work upto plinth level 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
CODE NO.5.2.3 Reinforced cement concrete work in walls (any thickness) , including attached pilasters, buttresses , plinth and string courses , fillets , columns , pillars , piers , abutments , posts and struts etc. upto floor five level excluding cost of centering , shuttering , finishing and reinforcement - 1:2:4 (1 cement : 2coarse sand :4 graded stone aggregate 20mm nominal size)
CODE NO.5.3 Reinforced cement concrete work in beams, suspended floors , roofs having slope up to 15degree landings , balconies , shelves , chajjas , lintels , bands , plain window sills , staircases and spiral stair cases upto floor five level excluing the cost of centering ,shuttering, finishing and reinforcement , with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
CODE NO.5.9.1 Centering and shuttering including strutting , propping etc and removal of form for - foundations, footings, bases of columns etc for mass concrete
CODE NO.5.9.3 Centering and shuttering including strutting , propping etc and removal of form for - Suspended floors , roofs , landings , balconies and access platform
CODE NO.5.9.5 Centering and shuttering including strutting , propping etc and removal of form for - Lintels , beams , plinth beams , girders , bressumers and catilevers
CODE NO.5.9.6 Centering and shuttering including strutting , propping etc and removal of form for - Columns , Pillars , Piers ,Abutments , Posts and Struts
CODE NO.5.12 Providing , hoisting and fixing upto floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement , with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
CODE NO.5.22.6 Steel reinforcement for R.C.C.work including straightening , cutting , bending , placing in position and binding all complete upto plinth level – Thermo -Mechanically treated bars (TISCON / VIZAG / IISCO / SAIL / JSW) Fe - 415 or more
CODE NO.6.1.2 Brick work with common burnt clay F.P.S. (non modular ) bricks of class designation 3.5 in foundation and plinth in – cement mortar 1:6 (1 cement : 6 coarse sand)
CODE NO.6.4.2 Brick work with common burnt clay F.P.S (non modular ) bricks of class designation 3.5 in superstructure above plinth level upto floor five level in all shapes and sizes in - cement mortar 1:6 ( 1 cement : 6 coarse sand)
CODE NO.6.13.1 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level upto floor V level – cement mortar 1:3 (1 cement : 3 coarse sand)
CODE NO.10.5.1 Providing and fixing 1mm thick M.S.sheet door with frame of 40x40x6 mm angle iron and 3mm M.S.gusset plates at the junctions and corners , all necessary fittings complete, including applying a priming coat of approved steel primer - Using M.S.angels 40x40x6mm for diagonal braces
CODE NO.10.25.2 Steel work welded in built up sections / framed work , including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required – in gratings, frames, guard bar, ladder, railings, brackets,gates and similar works
CODE NO.11.3.1 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc .complete - 40mm thick with 20mm nominal size stone aggregate
CODE NO.11.36A Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) , of approved make (Jhonson / Asian / Somany / Nitco) in all colours , shades of size 200 x 300 mm as approved in skirting , risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement with pigment of matching shade complete – size 200x300 mm
CODE NO.11.40 Providing and laying rectified glazed ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make (Somany / Nitco / Jhonson) in all colours , shades, except white, ivory, grey, fume red brown, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigments etc., complete
CODE NO.12.20 Providing and laying pressed clay tiles (as per approved pattern 18mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound , laid over a bed of 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete
CODE NO.12.41.2 Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes – 110 mm diameter
CODE NO.12.42.5.2 Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - bend 87.5 degree - 110 mm bend
CODE NO.12.42.6.2 Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - shoe (plain) -110mm shoe
CODE NO.12.43.2 Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50mm hard wood plugs , screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc., complete - 110mm
CODE NO.13.8.3 12 mm cement plaster of mix 1:5 (1 cement : 5 fine sand)
CODE NO.13.16.1 6mm cement plaster of mix 1:3 (1 cement : 3 fine sand)
CODE NO.13.28.3 12mm thick plain cement mortar bands in cement mortar 1:4 (1cement : 4 fine sand) – raised band
CODE NO.13.46.1 Finishing walls with acrylic smooth exterior paint of required shade - New work (two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm
CODE NO.13.61.1 Painting with synthetic enamel paint of approved brand and manufacutre to give an even shade - Two or more coats on new work
CODE NO.15.2.2 Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead-Nominal concrete 1:4:8 or leaner mix (including equivalent design mix)
CODE NO.15.7.4 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead - in cement mortar
CODE NO.15.23.1 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead – for thickness of tiles 10mm to 25mm
CODE NO.15.56 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead
CODE NO.18.9.11 Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing . This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall ) - 20mm nominal outer dia pipes
CODE NO.18.15.2 Providing and fixing brass bib cock of approved quality - 20 mm nominal bore
CODE NO.18.48A Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI: 12701 marked , with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank - Circular Tank
CODE NO.8.3B Printing new letters and figures of any shade with synthetic enamel paint black or per letter any other approved colour to give an even shade - English and Roman
Balaraman
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_9714.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .