Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.0 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED DUE TO LOWEST | |
| 2 | L2₹25.5 L+₹2.1 L (8.91%)Rejected-AOC FLAT NO B 205 S NO 296 2 DIVINE HOMES PORWAL ROAD LOHEGAON PUNE 411047 | PUNE | MAHARASHTRA | 411047 | L2 | Rejected-AOC REJECTED DUE TO NOT LOWEST | |
| 3 | L3₹26.8 L+₹3.4 L (14.4%)Rejected-AOC 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L3 | Rejected-AOC REJECTED DUE TO NOT LOWEST |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
6 Sept 2022, 6:00 pmClosed
GE (AF) LOHEGAON
GE (AF) LOHEGAON, PUNE -411032
REPAIR AND MAINTENANCE OF PUMP SETS, SUBMERSIBLE PUMP SETS, MISC WORKS, CLEANING AND DISINFECTING UG SUMPS, OH RESERVOIRS AT 2 WG AND 9 BRD UNDER GE (AF) LOHEGAON AT AIR FORCE STATION PUNE
2022_MES_544851_1
8603/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) LOHEGAON
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (AF) LOHEGAON
₹76,000
Yes
4 Nov 2022
11 Aug 2022
13 Sept 2022
11 Aug 2022
6 Sept 2022
25 Aug 2022
Amount
Taking out the submersible pump/Openwell Submersible Pump set for repairs and lowering down after repairs the submersible pump set of any capacity & of any type from the bore well to a depth of not exc. 70 mtrs including scrapping of the existing paint of submersible pump set and applying two coats of anti corrosive paint over a coat of primer complete after repair / replacement of spares and commisssioning complete all as specified and directed. [NOTE: COST OF REPAIR SHALL BE MEASURED AND PAID AGAINST RELEVANT ITEM]
Repairs to submersible Pump set of electric driven of any type make and capacity upto 5 HP incl rewinding of the motor with same gauge and weight of PVC insulated copper conductor incl renewal of thrust plate, CI bowl, pump shaft, impeller, Bearing, strainer, bush cable gaurd etc. reassembling, testing and commissioning complete all as specified and directed.
Repairs to Non clog ,Open well submersible Pump set of electric driven of any type make and capacity upto 5 HP incl rewinding of the motor with same gauge and weight of PVC insulated copper conductor incl renewal of Mechanical seal, Bearing ,thrust plate, CI bowl, pump shaft, impeller , strainer, bush cable gaurd etc. reassembling, testing and commissioning complete all as specified and directed.
Renewal of column pipe 50 mm dia heavy duty ISI marked , 10 feet length both ends machine threaded with long thread heavy duty socket complete all as specified and directed.
Replacement of unserviceable PVC weather proof cable and replacement with new PVC weather proof copper cable for size 3 core 2.5 sqmm suitable for submersible pump set complete all as specified and directed.
Replace of non return valve gun metal 50 mm bore complete all as specified and directed.
Replace of non return valve gun metal 150 mm bore complete all as specified and directed.
Taking out old unserviceable MCCB 400 Amps and replacing the same with new MCCB 415 V,25 KA ,4 Pole ,400 Amps complete all as specified and directed.
Taking out old unserviceable MCCB 200/250 Amps and replacing the same with new MCCB 415 V,25 KA ,4 Pole ,200/250 Amps complete all as specified and directed.
Taking out old unserviceable MCCB 160 Amps and replacing the same with new MCCB 415 V,25 KA ,4 Pole ,160 Amps complete all as specified and directed.
Taking out old unserviceable MCCB 100 Amps and replacing the same with new MCCB 415 V,25 KA ,4 Pole ,100 Amps complete all as specified and directed.
Taking out old unserviceable MCCB 63 Amps and replacing the same with new MCCB 415 V,25 KA ,4 Pole ,63 Amps. complete all as specified and directed.
Material and labour for reparing/maintenance of existing electrical panel boards of pump sets by replaing worn out spares as starter/single phase preventor/ relay /contactors MCCB's / MCB's / switch gear / cable glands/ lugs pin type, U type etc, cleaning of panel board, tightening of cable connection to avoid sparking, insulating bus bars bracket portion of conductor and to ensuring proper function of the panel board complete all as specified and directed. NOTE: ( I ) Cost of spares as starter /single phase preventor/voltmeter/Amp meter/ relay / contactor /MCCB's/ MCB's / Switch gear / cable gland etc shall be measured and paid against relevant item. (ii) Cost of lugs (pin type / U Type) ,insulation taps shall be included in quoted rate. (iii) Cost of fixing of spares shall deemed to be included in quoted rate.
Renewals/replacing the following spares to the existing elecrical panels complete all as specified and directed.
Indicator Lamp LED Type
S & F Digital Voltmeter, 3phase, 0-500v,class-I, suitable as per existing
S& F Ammeter ,3 phase for range 0-200A Class-I, suitable as per existing
S&F in replacement of old unserviceable contactor of capacity upto 45 A, power operating voltage 415 V AC Capacity 3 pole with AC coil etc (Make: L & T,TC)
S&F in replacement of old unserviceable contactor 0f capacity upto 95 A, power operating voltage 415 V AC Capacity 3 pole with AC coil etc (Make: L & T,TC)
S&F in replacement of old unserviceable contactor of capacity upto 110/120 A, power operating voltage 415 V AC Capacity 3 pole with AC coil etc (Make: L & T,TC)
Over load relay with range 16 to 45 A (Make: L & T)
Over load relay with range 45 to 88 A (Make: L & T)
S& F Single phase preventor including Timer, 415 V suitable for 100 HP motor.
Dismantling the centrifugal Pump of capacity Upto 3HP including disconnecting suction and delivery etc and reassembling after replacement of necessary spares including greasing and painting of 2 coats of synthetic enamel paint using spray machine complete all as specified and directed. [NOTE: Replacemnt of worn out spares will be measured and paid separately].
Ditto all as per Ser Item No 15.00 above but for the capacity of 5 HP to 7.5 HP complete all as specified and directed.
Ditto all as per Ser Item No 15.00 above but for the capacity of 10 HP to 15 HP complete all as specified and directed.
Ditto all as per Ser Item No 15.00 above but for the capacity of 20 HP to 30 HP complete all as specified and directed.
Ditto all as per Ser Item No 15.00 above but for the capacity of 40HP to 50HP complete all as specified and directed.
Ditto all as per Ser Item No 15.00 above but for the capacity of 60HP to 75 HP complete all as specified and directed.
Ditto all as per Ser Item No 15.00 above but for the capacity of 90HP to 100HP complete all as specified and directed.
Supply and replace following worn out spares of Centrifugal/monoblock pump sets complete all as specified and directed.
Bearing as per existing Size suitable for up to 3HP motor complete all as specified and directed.
Bearing as per existing Size suitable for 5HP to 7.5 HP motor complete all as specified and directed.
Bearing as per existing Size suitable for 10 HP to 12.5 HP motor complete all as specified and directed.
Bearing as per existing Size suitable for 20 HP to 30HP motor complete all as specified and directed.
Bearing as per existing Size suitable for 40HP to 50 HP motor complete all as specified and directed.
Bearing as per existing Size suitable for 60HP motor complete all as specified and directed.
Bearing as per existing Size suitable for 75 HP motor complete all as specified and directed.
Bearing as per existing Size suitable for 90 HP motor complete all as specified and directed.
Bearing as per existing Size suitable for 100 HP motor complete all as specified and directed.
Rubber bush for coupling as per existing size for upto 30 HP motor complete all as specified and directed.
Rubber bush for coupling as per existing size for upto 50HP motor complete all as specified and directed.
Rubber bush for coupling as per existing size for upto 75 HP motor complete all as specified and directed.
Rubber bush for coupling as per existing size for upto 90 HP motor complete all as specified and directed.
Rubber bush for coupling as per existing size for upto 100 HP motor complete all as specified and directed.
Gland packing upto 30 HP pump complete all as specified and directed.
Gland packing for 40 HP motor complete all as specified and directed.
Gland packing for 50 HP motor complete all as specified and directed.
Gland packing for 60 HP motor complete all as specified and directed.
Gland packing for 75 HP motor complete all as specified and directed.
Gland packing for 90 HP motor complete all as specified and directed.
Gland packing for 100 HP motor complete all as specified and directed.
Supply and replace old worn out coupling with new Tyre coupling including machining, suitable to shaft dia of pump and motor of 5HP,12.5HP,20HP complete all as specified and directed.
Supply and replace old worn out coupling with new Tyre coupling including machining, suitable to shaft dia of pump and motor of 30HP,40HP,50HP complete all as specified and directed.
Supply and replace old worn out coupling with new Tyre coupling including machining,suitable to shaft dia of pump and motor of 60HP, 75HP, 90HP, 100HP complete all as specified and directed.
Overhauling/servicing of Suction sweeper assembly trolley mounted with mud pump motor head 11.5 mtr make; Kirloskar for swimming pool complete all as specified and directed. Notes:- including spares require for making the assembly serviceable deemed to be included in subjected item.
Taking down electric motor 3 phase, 415 Volt capacity 1/2HP TO 3 HP, incoming disconnection electric connections, dismantling slots, taking out burnt windings and rewinding the motor with super enameled copper wire as per existing size including insulating material and varnishing, greasing, painting with super enameled paint as per colour coad assembling the motor after rewinding and mounting at its own position, replacing the old nut, bolts and testing complete all as specified and directed.
Ditto all as per Ser Item No. 27.00 above but for the capacity of 5HP complete all as specified and directed.
Ditto all as per Ser Item No. 27.00 above but for the capacity of 10HP,12.5HP complete all as specified and directed.
Ditto all as per Ser Item No. 27.00 above but for the capacity of 15HP,20HP complete all as specified and directed.
Ditto all as per Ser Item No. 27.00 above but for the capacity of 30HP complete all as specified and directed.
Ditto all as per Ser Item No. 27.00 above but for the capacity of 40HP complete all as specified and directed.
Ditto all as per Ser Item No. 27.00 above but for the capacity of 50HP complete all as specified and directed.
Ditto all as per Ser Item No. 27.00 above but for the capacity of 60HP complete all as specified and directed.
Ditto all as per Ser Item No. 27.00 above but for the capacity of 75HP complete all as specified and directed.
Ditto all as per Ser Item No. 27.00 above but for the capacity of 90HP complete all as specified and directed.
Ditto all as per Ser Item No. 27.00 above but for the capacity of 100HP complete all as specified and directed.
Taking out unserviceable foot valve 80 mm dia from the UG sump and S & F new foot valve 80 mm dia ball type incl rubber gasket, bolts, buts complete all as specified and directed.
Taking out unserviceable foot valve 100 mm dia from the UG sump and S & F new foot valve 100mm dia ball type incl rubber gasket, bolts, buts complete all as specified and directed.
Taking out unserviceable foot valve 150 mm dia from the UG sump and S & F new foot valve 150mm dia ball type incl rubber gasket, bolts, buts complete all as specified and directed.
Supply and fix spares for pumps of DSM 150/45, DSM 100/36, DSM 125/45, DBHS
Impeller 1st , II nd Stage
Pump Shaft
Shaft sleave
Cartridge bearing DE/NDE
Through bush
Split gland coupling
Wear ring
Lantern Ring
Gland coupling
Supply and replacing Automatic DOL starter suitable up to 5 HP submersible/ centrifugal pump set (Make : as Per existing Make)
Supply and replacing Automatic star Delta starter suitable 7.5 HP to 12.5 HP submersible/ centrifugal pump set (Make : as Per existing Make)
Replacement of nuts bolts to top & bottom cover of DSM pump 100 HP, 90 HP, 75 HP.
Supply & fixing in replacement LT cable 1100 volts grade PVC insulated multistranded copper conductor cable single core of size 35 sqmm.
Servicing of Magnetic level sensor i/c removing, cleaning, greasing, checking for wear and tear, refixing, testing, installing, commissioning complete all as specified and directed. Note : Spares if needed are not included in the above
Supply only in repair/replacement of Water Level Controller 5 Level/ 10 Level complete all as specified and directed.
Supply and fix in repair/replacement of Magnetic Level Sensor Make : RDS/CRISTAL
Supply and Fix Wire connection for Water level sensors and indicator of twelve core including installlation, testing and commissioning complete all as specified and directed.(Make: Sinetrac or equivalent)
M&L for seven stage cleaning and sterilization of inside the RCC/ Steel Underground/semi underground/Over head/Sedmentation/clear water sumps of capacity As mentioned through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY. Make: rays Cleantech/ Inus watertech/ satya enterprise:- (a). First Stage is to drain out the water by using exit valve or high capacity dewatering system. (b). Second stage is cleaning all the algae formation inside the tank by using TERBAC G10/ Inoxi-60/NB-69 a laboratory tested branded chemical of the company ans scrubbing the walls of the tanks. (c). Third strage is fresh water cleaning by high speed jet pump. (d). Fourth stage and first bacteria screening is decertification by using TERBAC-G5/ Inohor-5/NB-10 a Govt Laboratory certified brannded halogen compound. (e). Fifth stage is cleaning the floor of water tank by industrial vaccum cleaner. (f) . Sixth stage is the second bacterio screening and sterilizing method by using ultra violet ray within the tnk and kills all suspended bacteria. (g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified, branded strong oxidizing agent TERBAC-G65/Inoxi-60/NB-69 . NOTE:-(i) COMPANY WILL SUBMIT GOVERNMENT LABORATORY TEST CERTIFICATE OF TERBAC-G5/INCHOR-5/NB-10, TERBAC-G65/ INOXIi-60/NB-69, BEFORE CLEANING, FIX THE STICKER MENTIONING THE DATE OF CLEANING & NAME OF SITE AND ALSO PROVIDE CERTIFICATE CONFIRMING THE COMPLETION OF STERILIZATION OF WATER TANKS MENTIONING THE NAME OF STATION AND DATE OF CLEANING. ALL THE CLEANING & STERILIZATION STAFFS SHOULD BE UNDER ACCIDENTAL INSURANCE COVERAGE.) (ii) OUTLET PIPE OF OHT SHOULD BE PLUGGED BEFORE CLEANING THE OHT TO AVOID.ENTERING SCALS AND THE SAME SHELL BE RECONNECTED AFTER CLEANING THE OHT AND THE QUOTED RATE IS DEEMED TO INCLUDE FOR THE ROVISION . (III) STERILIZATION TEAM WILL BE COMPRISED OF AT LEAST 30% MEMBERS WHO ARE MINIMUM 03 MONTS CERTIFICATE HOLDER IN WATER TANKS STERILIZATION. (IV) CONTRACTOR WILL BE RESPONSIBLE FOR RECTIFICATION OF COMPLAINTS OCCURRED DURING CLEANING THE TANK IE. NO WATER IN TANK/OVER FLOW DUE TO BROKEN OF FLOAT VALVE/ BLOCKAGE TO BE INCLUDED IN QUOTED RATE. NOTE:-THE WORK SHALL BE CARRIED THROUGH SPECILIZED AGENCY.
Ditto all as per Ser Item No. 50.00 above but for UG sump 100000 gallons capacity
Ditto all as per Ser Item No. 50.00 above but for UG sump 10,000 gallons capacity
Ditto all as per Ser Item No. 50.00 above but for UG sump 50000/30000 gallons capacity
Ditto all as per Ser Item No. 50.00 above but for O H Reservoir 300000 glns capacity
Ditto all as per Ser Item No. 50.00 above but for O H Reservoir 50000 glns capacity
Ditto all as per Ser Item No. 50.00 above but for O H Reservoir 150000 glns capacity
Ditto all as per Ser Item No. 50.00 above but for O H Reservoir 10000 glns capacity
Ditto all as per Ser Item No. 50.00 above but for O H Reservoir 25000 glns capacity
Cleaning fire static tank for fire fighting system drain out of water and taking out the sludges from the bottom of the static tank and clean surface by scraping and two coats of white cement wash of capacity up to 10000 Glns complete all as specified and directed.
Cleaning fire static tank for fire fighting system drain out of water and taking out the sludges from the bottom of the static tank and clean surface by scraping and two coats of white cement wash of capacity 10001 to 15000 Glns complete all as specified and directed.
Cleaning fire static tank for fire fighting system drain out of water and taking out the sludges from the bottom of the static tank and clean surface by scraping and two coats of white cement wash of capacity 15001 to 25000 Glns complete all as specified and directed.
Cleaning fire static tank for fire fighting system drain out of water and taking out the sludges from the bottom of the static tank and clean surface by scraping and two coats of white cement wash of capacity 50000 Glns complete all as specified and directed.
S&F spare parts of chlorine dozers at various loaction complete all as specified and directed.
Pump head (ferrules 1/4 & duckbill included)
Pump Tube (pack of 5)
Injection cheack valve 3/8"
3/8 " white suction/discharge tubing
Check valve duck bill only (pack of 5)
Connecting nut 3/8 "
Connecting nut 3/8 with adapter(pack of 5)
Ferrule 1/4 " (pack of 24)
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not lessthan 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip of size 25x4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
XLPE insulated, armoured heavy duty electric cable withn aluminium conductor, 1100 volts grade, cross-sectional area 185 sq. mm,3.5 core complete all as specified and directed.
XLPE insulated, armoured heavy duty electric cable withn aluminium conductor, 1100 volts grade, cross-sectional area 95 sq. mm,3.5 core complete all as specified and directed.
Supply and fix wall mounted metal enclosure consist of On load change over of capacity 250 Amps 415V, 4 pole to be installed complete all as specified and directed.
Painting of pipes with new paint after scrapping the old paint of size 200mm, 250mm, 300mm complete all as specified and directed.
Painting of pipes with new paint after scrapping the old paint of size 50mm, 100mm, 150mm complete all as specified and directed.
BSK Construction
metro electrical services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .