CWE Chandimandir
HQ CWE Chandimandir, PIN-134107
CWE/CHM(U)-52/2026-27 REPAIR AND MAINTENANCE OF 11 KVA HT VCBs, RMUs DISTRIBUTION TRANSFORMER, EARTHING AND CONNECTED ITEMS AT COMMAND HOSPITAL (WC) UNDER GE (U) CHANDIMANDIR
2026_MES_783007_1
CWE/CHM(U)-52/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (U) Chandimandir
Class E, Cate b(ii)
8 documents required · 8 mandatory
₹500
GE (U) Chandimandir
₹20,000
31 Aug 2026
6 Aug 2026
2 Sept 2026
6 Aug 2026
31 Aug 2026
24 Aug 2026
6 Aug 2026 - 13 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Material and labour for opening of HT, 11KV, 630 Amp, VCB front and back side complete after taking shutdown HT breaker, Timing test, CRM test, insulation resistance test, calibration test, check motor charge mechanism, potential transformer resistance measurment, checking control power cable connection, cleaning the dusting inside & out side of VCB, greasing, oiling the mechanical parts and relay setting of VCB and Complete servicing and testing overload relay, digital voltmeter, digital ammeter, indication lamp and all the protective equipment inside the VCB to be serviced and working properly with necessary replacement of defective equipments complete all as specified and as directed by Engineer-in-Charge. | 9 | Each Job | 1.25 | ₹11.25 |
| 2Supply Only following spare parts suitable for VCB 630 Amp, 11 KV | |||||
| 2.01 | Supply only REJ 601 over current earth fault relay | 1 | Each | - | - |
| 2.02 | Supply only Master Trip Relay 24V DC | 1 | Each | 100 | ₹100 |
| 2.03 | Supply only VCB housing spout | 6 | Each | 53 | ₹318 |
| 2.04 | Supply only copper closing/ trippling coil | 3 | Each | 10 | ₹30 |
| 2.05 | Supply only VCB Jaw contact | 9 | Each | 11 | ₹99 |
| 2.06 | Supply only 11 KV VCB mechanism assembly | 1 | Each | 53 | ₹53 |
| 2.07 | Supply only Auxiliary for VCB | 2 | Each | - | - |
| 3 | M&L for setting of 3 phase over current + earth fault relays by secondary injection of current with suitable equipment for over current & earth fault with high set and low set including necessary checking of trip circuit, relay circuit, closing circuit, alarm circuit, DC supply circuit, AC supply circuit and repair of same as required for 11 kV VCB after disconection of incoming and out going HT XLPE cable connection and reconnection of cable ends at existing terminals after completion of relay setting complete all as specified and as directed by Engineer-in-charge. | 2 | Each Job | 1.25 | ₹2.5 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
Tenderdocuments52.pdf
Tender Documents • 0.57 MB
Additional52.pdf
Additional Documents • 0.47 MB
BOQ_877270.xls
BOQ • 0.48 MB
Amdt1.pdf
PDF • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].