Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹63.7 LAccepted-Finance 565 566 ANNA NAGAR HOUSING UNIT II PONGALUR ROAD VEERAKERALAM SUGERCANE INSTITUTE POST COIMBATORE 641007 | COIMBATORE | COIMBATORE | TAMIL NADU | 641007 | ₹63.7 L | L1 | Accepted-Finance As per the quoted rate |
| 2 | L2₹64.6 L+₹90,943.70 (1.43%)Accepted-Finance | ₹64.6 L+₹90,943.70 (1.43%) | L2 | Accepted-Finance As per the quoted rate |
| 3 | Rejected-Technical | - | - | Rejected-Technical Due to noncompliance of BQR conditions |
| 4 | Rejected-Technical 002 1 NATHAKADU SRI MAHALAKSHMI DYEING PRINTING MILLS CAMPUS BHAVANI MAIN ROAD ERODE 638004 | ERODE | ERODE | TAMIL NADU | 638004 | - | - | Rejected-Technical Due to noncompliance of BQR conditions |
Tender Value
Refer Docs
EMD Value
₹58,400
Closing Date
18 Dec 2020, 2:00 pmClosed
The Chief Engineer/Distribution/TANGEDCO/Trichy
The Chief Engineer,Distribution,TANGEDCO,Thennur,Trichy
Laying of UG cable 3 Core x 400 sq. mm as main 33 KV source feeder from 110-33-11 KV Aachaalpuram SS to the existing 33 -11 KV Arasur Substation UG cable laying lead from Aachaalpuram SS to CH- 5.341KM in Arasur section of Sirkali Division
2020_EB_186867_1
CE/D/TRY/69/2020-21
Open Tender
Composite Works
Works
120 days
Aachaalpuram, Nagapattinam
As per the tender specification
4 documents required · 4 mandatory
₹0
₹58,400
Yes
1 Feb 2021
5 Dec 2020
19 Dec 2020
5 Dec 2020
18 Dec 2020
5 Dec 2020
Amount
Removing the black topping of 30 CM thickness and farming cable open trench of road crossing 60 CM wide and 135 CM deep (clear) including cost of using machinary providing danger lights, indication arrangements wherever necessary Labour, Lead, Lift, Tools and Plants etc., complete. The removed Tar blacks debris shall be removed stork at free place of site for requested by Highways and corporation departments.
Earth work excavation in all soils including slush and silt under water requiring the aid of basket and vessels and forming cable trench at road crossing 60 CM wide and 105 CM deep (clear) including cost of signal boards, danger lights, indication arrangements wherever necessary and providing shoring and struthing arrangements wherever necessary all labour, lead, lift, tools and plants etc., complete. The excavated earth should be placed in one side of trench preparably on foot path side, not to obstruct free flow of traffic
Using machine for a width of 60 CM to a depth of 40 CM (Achaluram ss to CH 5341Rm)
Using labour to a breath of 60 CM and a depth of 95 CM (Achaluram ss to CH 5341Rm) in Arasur Section of Sirkali Division.
Providing M.S.barri cading 1.5 m height using M.S.sheet 4 mm thick MS angle 50x50x8 m base channel 100 x 50 of all materials leads, lifts, labour, welding and erection, transporting at site, placing in position. Shifting to new location after completing works tools & plants etc., complete
Laying PVC pipes 200mm dia including cost of jointing pastecoupling and other required items including cost of all labour lead, lift,etc., complete. (200mm dia PVC pipes will be supplied by TANGEDCO)
Erection of GI pipes 180mm dia including cost of fixing charge, necessary clamp etc., complete (Materials Supplied Tangedco).
Laying plain cement concrete 1:3:6 using 20 mm BG metal for fixing PVC pipe in the UG cable in proper alignment and level as per standard specification including cost of all materials, labour, lead, lift,curing etc., complete
Transporting of 33 KV cable drums including cost of looding at stores, unloading of 33 KV cable drums each weighting approximately 7 Tonne in lorries using truck mounted crane for both loading and unloading including cost of labour, required etc.,
Laying of 3X400 sq. mm 33 KV XLPE UG (3RUN)cable by means of winch over rollers provided by contractor. The rate includes the cost of pulling the steel wire rope from which side to drum side providing labour as required at site for tying the cable in free foil formation with nylon rope etc., complete (Cable supplied by TANGEDCO) (Achaluram ss to CH 5341Rm)
Refilling with river sand in layers well consolidated as per standared specification including cost of all materials, labour, lead, lift etc., complete. (Achaluram ss to CH 5341Rm)
Placing the cover slab for cable protection, including cost of all materials, lead, lift, etc., complete.
Refilling with excavated earth in layers and well consolidated as per standared specification including cost of all materials, labour, lead, lift etc., complete
Transporting and cleaning the excess excavated and debris then and there immediately to avoid any hinderence to the normal flow of traffic and public beyond a distance of 5 km trem the work spot as per the direction of Engineer in charge including loading and unloadings etc., complete.
Transporting of 33 KV empty drums loading at site and devolution of empty 33 KV steel cable drum each weighting 1 to 1.5 T from various work site and balance cable if any to departmental stores.
Providing watch and ward (unskilled) at site as instructed by the Engineer incharge at site.
Bailing out water from cable french while excavating and also while laying cable using 5 HP diesel pump including cost of fuel, operator etc., complete.
Erection of straight through Heat shrinkable outdoor type 3X400 Sq.mm Cable joint kit including cost of all materials lead ,lift, errection and testing etc., complete (Materials Supplied by the Tangedco).
Erection of Heat shrinkable outdoor type 3X400 Sq.mm Cable termination kit including cost of all materials lead ,lift, errection and testing etc., complete
Erection of double pole structure with AB switch provision for 33KV UG cable (3X400 sqmm) including cost of all materials,such as lead,lifting,fixing and termination of cables (In and Out)both ends,and commissioning etc.,(Materials Supplied by the Tangedco).
Erection of Four pole structure with AB switch provision for 33KV UG cable (3X400 sqmm) including cost of all materials,such as lead,lifting,fixing and termination of cables (In and Out)both ends,and commissioning etc.,(Materials Supply by Tangedco)
Casting and placing of RCC offset slab (cable route indication slab)of size 750x750x60 mm castingin RCC 1:3:6 using 12 to 20 mm HBG metal with necessary reinforcement,piling,shuttering,curing,transport from cast yard to various locations & fixing the slab along 33 KV cable.
(a)Cable route marker for every 100m (engraving TANGEDCO Power cable)
(b)Cable joint location marker (engraving TANGEDCO Cable Joint)
Supply and laying of Warning tape (Yellow colour as TANGEDCO printed) of size 150mm wide and thickness P100 microns (0.1mm) as per std specifications including cost of all materials,lead,lift,labour and laying at the depth of 0.5 m below the ground level etc., complete.
State High Ways Road crossing of 3x400 sq mm 33 KV UG Cable by Horizontal boring method location including cost of all materials lead ,lift, Transporting, cable laying, HDPE Pipe, Bold nuts, Materials etc, complete.( as per the direction of Highways)
SENTUR CONSTRUCTIONS
SREE SRINIVASA ASSOCIATES
PD PROMOTORS PVT LTD
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
finance_223433.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .