Chief Engineer Jabalpur Zone
HQ Chief Engineer Jabalpur Zone Ridge Road Jabalpur Cantt 482001
PROVN OF OFFICE COMPLEX CLASSROOM AND BATHROOM AT TRAINING CELL FOR TRAINING OF JAK RIF REGIMENTAL CENTRE AT JABALPUR MIL STN
2025_MES_730506_1
752999A PROVN OF OFFICE COMPLEX CLASSROOM AND BATHROOM AT TRAINING CELL FOR TRAINING OF JAK RIF JBL
Open Tender
Civil Works
Lump-sum
545 days
JABALPUR
AS PER NIT
7 documents required · 7 mandatory
₹2,000
GE P No 01 Jabalpur
₹3.7 L
Yes
3 Nov 2025
22 Sept 2025
12 Feb 2026
1 Nov 2025
5 Feb 2026
17 Jan 2026
.Duct work shall be rigid and straight without kinks.All exposed ducts within the conditioned space shall have slip joints. Flanged joints shall not be used.Powder coated alumium Grill and Volume control damper should be used.Ducts shall be supported independently from the building structure and adequately, to keep the ducts true to shape. The support spacing shall be not more than 2 m.Duct connections to the air-handling unit shall be made by inserting a double canvas sleeve .The steel sheets shall be hot dip galvanized with MAT finish with coating of minimum 120 grams per square meter (GSM) of Zinc, GI sheets shall be lead free, eco friendly and RoHS compliant.
Sch 'A' Part-II (External Electric Supply) Lump sum price worked out by the contractor for (External Electric Supply) as listed in Schedule 'A' Part-II against the lump sum price inserted by the MES.
Item No 01 : Design and Construction of Office complex, classroom & bathroom (Building Plinth Area : 1318.35 Sqm) with permanent specification, RCC Framed Construction, Provn of ATT & APP, M-25 Concrete, exterior emulsion (emulsion paint/ weather coat), roof treatment with polymeric water water proofing treatment, complete all specified in soil bearing capacity report, design basis report design basis report drawings and tender documents.
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
Sch 'A' Part-III (External Water Supply) Lump sum price worked out by the contractor for (External Water Supply) as listed in Schedule 'A' Part-III against the lum
p sum price inserted by the MES.
Sch 'A' Part-IV (Road, Path Curvert) Lump sum price worked out by the contractor for (Road, Path Curvert) as listed in Schedule 'A' Part-IV against the lump sum price inserted by the MES.
Item No 18 : M&L Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.40 M x 3.0 M depth complete
Sch 'A' Part-VI (Area Drainage) Lump sum price worked out by the contractor for (Area Drainage) as listed in Schedule 'A' Part-VI against the lump sum price inserted by the MES.
Sch 'A' Part-VII (Site Clearance) Lump sum price worked out by the contractor for (Site Clearance) as listed in Schedule 'A' Part-I against the lump sum price inserted by the MES.
Note for Srl No 2 to 12 The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 2 to 12 by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule
(a) MCCB 4 Pole 160 Amps, 36 KA with Rotary Handle, microprocessor release adjustable amp Ics = 100% Icu as per IEC 60947-2 , Adjustable Over load from 0.5 to 1*In , Adjustable Short Circuit from 2 to 10*Ir , Adjustable Neutral Protection - N, N/2,OFF for 4 Pole MCCB , Inbuilt Thermal Memory- 01 No (incoming)
(b) Digital Voltmeter 3 Phase Class-1 50Hz - 01 No.
(c) Digital Ammeter 3 Phase Class-1 50Hz - 01 No.
(d) Indicator Lamps (LED type) & bakelite fuseshowing R,Y, G phase - 01 set
(iv) Auto control time switch, timer control for different 24 hours adjustable type including power contractor of capacity 20 amps complete - 01 Nos (1 x Garden Light)
OUT GOING
(i) MCCB 4 Pole 125 Amps,25 KA at 415 volts - 02 No.(1 No Trg Cell + 1 No Standby)
(ii) MCB 4 P 63 Amps,16 KA 415 volts - 01 Nos (Centralised Cooler)
Item No 02 : M& L for cable root indicator MS sheet embossed with LT 1100 Volts Volts UG made with CI Plate 6 mm thick fixed with MS angle Iron of size 30x30x4mm of length 400 mm long including PCC work 1:2:4 type B1 of size 150x150x150 mm complete all as specified & directed
Item No 03 : M& L for cable root indicator MS sheet embossed with HT 11000 Volts UG made with CI Plate 6 mm thick fixed with MS angle Iron of size 30x30x4mm of length 400 mm long including PCC work 1:2:4 type B1 of size 150x150x150 mm complete all as specified & directed
Item No 04 : Supply, installing, testing and commissioning out door type LT Panel of suitable size, Floor mounted, CPRI approved factory made totally enclosed, dust and vermin proof, shutter in front and in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and external surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in : -
Item No 05 : S & F Integral decorative LED bollard with IP 65/66 protection suitable for 10 watts LED with necessary elecrical connections with adequate size of Nuts and Bolts including junction box with 6-32 A MCB of size complete as all specified and as directed.
Item No 06 : Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 32x 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Item No 07 : Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 25 X 4 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Item No 08 : S&F earth continuity conductor or main earth lead of 32 X 6 mm GI strip with saddles and fixing screw etc for roof conductor and down conductor fixed to wall on batten or recess or ground for connecting earthing to various equipments as required complete all as directed.
Item No 09 : S&F earth continuity conductor or main earth lead of 25 X 3.15 mm aluminium strip with saddles and fixing screw etc for roof conductor and down conductor fixed to wall on batten or recess or ground for connecting earthing to various equipments as required complete all as directed.
Item No 10 : Supply and fix junction box made out of polycarbonate with IP 55/IP 65 protection of size 155 x 210 x 92 mm,having terminals for termination of cable with necessary nuts and bolts, including -02 Nos polycarbonate cable gland, 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps in and including fixing clamp of FI 50 x 6mm with necessary nuts and bolts complete all as directed.
Item No 11 : Material and labour for LT 1100 volts (Earthed) grade heat shrinkable end termination jointing kit indoor type complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70-150 sqmm complete all as specified and as directed.
Cooling Appliances
BUSBAR :- (i) 300 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round) insulators of suitable size and good insulation resistance
BUSBAR :- (i) 150 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round) insulators of suitable size and good insulation resistance
(a) MCCB 4 Pole 160 Amps, 36 KA with Rotary Handle, microprocessor release adjustable amp Ics = 100% Icu as per IEC 60947-2 , Adjustable Over load from 0.5 to 1*In , Adjustable Short Circuit from 2 to 10*Ir , Adjustable Neutral Protection - N, N/2,OFF for 4 Pole MCCB , Inbuilt Thermal Memory- 01 No (incoming)
(b) Digital Voltmeter 3 Phase Class-1 50Hz - 01 No.
(c) Digital Ammeter 3 Phase Class-1 50Hz - 01 No.
(a) MCCB 4 Pole 100 Amps, 25 KA with Rotary Handle, microprocessor release adjustable amp Ics = 100% Icu as per IEC 60947-2 , Adjustable Over load from 0.5 to 1*In , Adjustable Short Circuit from 2 to 10*Ir , Adjustable Neutral Protection - N, N/2,OFF for 4 Pole MCCB , Inbuilt Thermal Memory- 01 No (incoming)
(e) Copper wound with CTR 300/5 - 03 Nos
(f) Copper wound with CTR 200/5 - 03 Nos
(i) MCB 4 P 'C' Series 32 Amps, 415 volts - 03 Nos
Item No 12 : Material and labour for preparation of new steel surfaces of any description over 10 cm width or girth and applying one coats of black bituminous paint complete all as specified and as directed.
Item No 13 : Supply and fixing of ducted cooler top/down discharge - 03 Nos/Floor nominal air delivery of 25000 CMH ,1.5 KW Motor power,cooling capacity upto 1600 sq ft UV Stablized High Grade Plastic of Tank capacity 70 litres Fan Dia 620 mm with Honeycomb pads of thickness 100 mm with 80 % minimum cooling efficiency,with 3 phase starter ,hanger hook and L shaped bracket including supply ,Installation ,commissioning and balancing of site fabricated Galvanised Sheet Steel (GSS) ducts conforming to IS: 277. Duct with 1:3 Ratio of 22G 0.7 mm and 24G 0.6 mm sheet from machine to ceiling height and ceiling to the alumium grills should rectangular shape ducting complete with neoprene rubber gaskets,nitrile rubber acoustic insulation of size 19 mm (inside) ,thermal insulation of size 6 mm (outside ),elbows,splitter damper vanes,hangars,supports
Item No 14 : Supply, installing, testing and commissioning out door type LT Panel of suitable size, Floor mounted, CPRI approved factory made totally enclosed, dust and vermin proof, shutter in front and in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arr
angement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and external surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in : -
Item No 15 : Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA
Item No 16 : Supplying and laying and jointing for (SN 8) DWCPE 180mm (OD)/ 163 (ID) conforning to IS-16098:2013 part -I with and incl jointing materials complete
Item No 17 : M&L RCC Septic tank conventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-25 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 50 users.
Schedule 'A' Part-II
(External Electric Supply)
Supply and laying or fixing or passing in trenches/ on pole/ through pipes,11000 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 70 sqmm, 3 core conforming to IS 7908 / (PART-I) 1988 with the latest amendments including jointing materials such as cable glands & lugs etc and testing on completion all as directed. Note:- Excavation, earth work, sand cushioning and cable protection shall be measured and paid separately.
Supply and laying or fixing or passing in trenches/ on pole/ through pipes,1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor conforming to IS 7908 / (PART-I) 1988 with the latest amendments including jointing materials such as cable glands & lugs etc and testing on completion all as directed etc of the under mentioned type and sizes :-
(a) 3.5 core x 70 sqmm
(b) 2 core x 6 sqmm (Garden lighting & Post top Lantern)
(c) 4 Core X 25 Sqmm (Centralised Cooler)
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes,etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified and as directed.
M/L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
M/L for Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
Supply and laying sand cushioning with dry and clean washed sand over and under the under ground cable in trenches, ducts for cable protection 150 mm below & 80 mm above the cable as protection of cable complete as specified & directed. Note : Punned thickness of sand shall be measured & paid.
Supplying and laying unreinforced precast concrete cable cover, class LV Type 2 flat, size 300mm x 180mm x 40mm complete all as specified and directed by Engr in charge.
Supplying and laying unreinforced precast concrete cable cover, class HV Type I, flat, size 300mm x 180mm x 40mm complete all as specified and directed by Engr in charge.
Supply and fixing steel tubular swaged pole, type 410 SP 55 (Overall length 11.00 meter) conforming to IS-2713 (Part 1 to 3) 1980 complete with cast iron base plate, finial taper plug, bolts, nuts and washers, screws. Pole shall be painted with two coat of black bituminous throughout internally and externally upto planting depth and the remaining external portion shall be painted with two coats of aluminium paints over a coat of red oxide primer, including painting white & red alternate strips of 30cm each externally from ground level upto 1.2m with synthetic enamel paint and writing numbering of poles with black paint on yellow background complete all as specified and as directed. (Note: Excavation and earth work and PCC shall be measured and paid separately under respective items)
M&L for cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminum paint complete all as specified and dircted.
Supply and fixing of switch air break gang operated triple pole mechanically operated horizontal type out door with all other fittings/ accessories mounted on & including porcelain insulators and steel frame with operating mechanism worked from ground level with & including operating rod of 32mm dia GI pipe medium grade (ISI marked) with MS handle with locking arrangement, for current rating up to 400 Amp 11000 Volts including dropout fuse set 15 insulators to suit gang operated triple pole 11 KV switch, connecting, commissioning and testing on completion complete all as specified and directed. Make:- JAIPURIA or PACTIL or BHEL or MEI as approved by GE.
(a) 50 mm Dia
(b) 80 mm Dia
M&L for PCC (1:2:4) type B2 using 40 mm graded stone aggregate as in foundation, filling, mass concrete and pilasters, buttresses columns, posts etc complete all as specified & directed.
M&L for Precast Reinforced Cement Concrete(RCC) 1:4:8 type D2 using 40 mm graded stone aggregate as in landings, cover slab (for manholes etc) and sim
ilar work including necessary form work and minimum reinforcement as per relevant IS code and set in CM 1:6 complete all as specified and directed. ( Note :Reinforcement shall be measured and paid for separately.)
M&L for 40 to 80mm graded broken stone aggregate for spreading/ loose filling in the substation or other places where directed including stacking materials in regular heap/ stack for measurement complete all as specified and directed.
(a) One cable box on primary (HV) side having cable glands suitable for OH conductor (consisting of 3 Nos porcelain HT bushings with brass/ gun metal bushing rods complete with nuts and washers). (b) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushing with GM bushing rods complete with GM nuts, and washers with one No. cable gland suitable for reception of outgoing LT armoured cables of suitable size. (c) Oil conservator tank with filter type, drain valve and oil level gauge.
Each set
M&L for GI tube light grade with all fitting laid in trenches of fixed to pole of size:-
M & L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25 x 20 cm size complete all as specified and directed.
Supply, fix for LED post top lantern 40 watt light fitting made of cast aluminium spigot housing with decorative opal acrylic diffuser with IP 65 protection complete with all accessories fixed on GI pipe 50 mm dia complete all as specified and directed.
Supply and fixing LED Solar street light fitting 36 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor with all connected accessories like nuts bolts clamps etc complete all as directed.
Material and labour for anti-climbing device, spike type fabricated from structural steel comprising of MS flat 20mmx6mm, MS round bar pointed, 8mm dia, 20cm length welded on MS flat fixed with nuts, bolts, washers and welding with and including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
S & F drop out fuse unit explusion type for out door air break gang oprated switch single pole mounted on and including two numbers insulators for 11 KV working pressure fixed to MS channel with nuts, bolts and washer etc and current carry capacity above 50 Amp upto and 100 Amp complete all as specified and as directed.
Supply only chain link MS galvanisd fencing, any size or type complete all as specified and directed.
Fixing only chain link fencing including line wire, any mesh, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wires complete all as specified and as directed.
Supply and fixing mild steel Fe 410-W (Gde-E- 250) quality-A, framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
Total carried over to BOQ Rs.
Schedule 'A' Part III
(External Water supply)
(ii) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase - 02 set
Supply and lay pipe galvanized, “Medium class”, including fitt
ings of dia 50 mm and all as directed.
Supply and lay pipe galvanized, “Medium class”, including fittings of dia 40 mm and all as directed.
Supply and lay pipe galvanized, “Medium class”, including fittings of dia 25 mm and all as directed.
Supply and lay pipe galvanized, “Medium class”, including fittings of dia 20 mm and all as directed.
S&F gun metal gate valve of following sizes screwed down high pressure with handle, Iron wheel (ISI marked) complete all as directed.
(a) 50mm bore
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes,etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified and as directed.
M/L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
M/L for Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part IV
(Road, Path Curvert)
Suraface excavation n.exc 30 cm deep and averaging 15 cm and getting out in soft/loose soil
Removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point.
M & L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering
Cement concrete type D-2 1:4:8 (using 20 mm graded aggregate) as in foundation filling and mass concrete , sub base complete all as directed.
Material and labour for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with aproved colour, design & attern as in foothpath, parks, lawns, drive ways or light traffic arking etc. of required strenght, thickness & size / shape, made by table vibrating method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding / laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra cement complete all as specified and directed.
M&L PCC 1:2:4 type B-1 (using 20 mm graded stone agg) as in seismic and other similar bands, coping, bed block or similar work including necessary form work complete all as specified.
Providing and laying at or near ground level factory made kerb stone incl earth work of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part V
(Sewage Disposal)
Excavating in trenches in any type of soil , n exc 1.5 m wide and n. exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soil complete all as specified and as directed.
Excavating in trenches in any type of soil , n exc 1.5 m wide and exc. 1.5 m in deep and n.exc 3.0m deep for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out soil complete all as specified and as directed
Returning, filling in, including spreading ,leveling, watering and well ramming in layers n. exc 25 cm with soil complete all as specified and as directed.
Removal of excavated material (soil) to a distance exc 50 m n. exc 250 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed.
M&L for concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:4:8 complete
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc.
M&L for Brick work with sub class B bricks straight or curved on plan exc. 6m mean radius built in cement mortar (1:4).complete all as specified and as directed.
M&L, 15mm thick rendering on any faces of stone, concrete or brick work in CM 1:4 surface finished even and fair complete all as specified and as directed.
M&L for 15 mm thick rendering in cement mortar (1:3) on brick / concrete/ stone surfaces mixed with water proofing compound as per manufacturer instruction , finished even and smooth using extra cement complete all as specified and as directed.
Supply only water proofing compound.
M&L for cement concrete type C2 1:3:6 (40mm graded stone aggregate) in foundations, filling and mass concrete complete
M&l for cement concrete 1:2:4 type B1 (20 mm graded stone aggregate) as in coping complete
M&L Precast cement concrete Type B-1 1:2:4 (Using 20 mm graded stone aggregate) in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:6 complete all as specified and as directed.
S&F TMT steel bars 6 to 8mm in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia) all as specified and directed
S&F TMT steel bars 5mm dia and over, up to and including 10mm dia in stirrups spcers and binders.
M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
M&L for cement concrete type B2 , 1:2:4 using 40 mm gradded stone aggregate in surface channels and drains complete
M&LRCC Septic tank conventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-25 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 50 users.
M&L Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.40 M x 3.0 M depth complete
M & L for DWCPE (SN8) 180 (OD)/163(ID) mm diameter Pipes laid on 150 mm thick bed with excavation in any type of soil, from 0.70 upto 1.65 mtr depth including manholes/drop manhole of standard size made of Brick masonry/ RCC/Precast RCC with SFRC ventilating cover and frame. Includes all items and activities to execute and make sewer line functional. As per IS 16098 (Part 2) : 2013 para A-4.1.2.4(a) any form of cement concrete structural bedding would not be necessary under normal conditions, even for maximum combined loading (wheel load + backfill).
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part VI
(Area Drainage)
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed.
M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L PCC in foundations, filling and mass-concrete type D2 (1:4:8) using 40 mm graded stone aggregate complete all as specified and directed.
M&L for RCC M-25 Design Mix as in fdn. all as specified
M & L 10mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces and finished the surface even & smooth without using extra cement complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in cills, PCC blocks, coping, bed plates, seismic and other similar bands, plinth bends, etc including weathering slightly rounded or chamfered angles and throuting, inclusing necessary form work etc complete all as specified and directed
M&L RCC type B 1, 1:2:4 (20mm graded agg) as in walls, retaining wall,basement walls etc
M&L Precast cement concrete Type B-1 1:2:4 (Using 20 mm graded stone aggregate) in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:6 complete all as specified and as directed.
Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9 mm dia or securing with clips complete.
Returning filling in including spreading levlling ,atering and well ramming in layers nexc 25cm thick complete all as specified and directed.
Removing excavated soil exc. 50m but not exceeding 250 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part VII
(Site Clearance)
Suraface excavation n.exc 30 cm deep and averaging 15 cm and getting out in soft soil.
Excavating over areas, n exc 1.5 m deep and getting out soft/Hard Soil
Earth filling (for site development) incl raising (or lowering) not exc 1.5 m high earth spreading in layers n.exc 30 cm thick watering and rolling and finishing to reqd size and shape etc
Removing excavated material to a distance exc 500m but n exc 1.5km, depositing where directed at a level n exc 1.5 M above the starting point.
Total carried over to BOQ Rs.
SIGNATURE OF CONTRACTOR
DATED _________
Item No 20 : Construction of brick masonry valve pit of size 1200 mm x 1200mm x 900 mm (internal dimensions) with one brick thick wall in cement mortar 1 : 4 on 100 mm thick PCC 1:4:8 type D2 (using 40mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in benching and coping and 10mm thick cement plaster in CM (1:4) internally and externally upto 15cm below ground level providing valve pit cover 40x40x6mm angle iron frame all-round fixed by means of 4 Nos holdfast 150mm long made out of flat iron 40x6mm embedded in PCC block (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) of size 230x200x100mm incl provn of hinges welded with angle iron frame and MS cover 3mm thck sheet, MS handle of suitable length and size welded with MS cover and suitable locking arrangement and applying two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation and earth work in soft/loose soil complete all as shown on drawing and as specified.
(Arboriculture)
Excavation in post holes (or similar holes) each n.exc. 0.50 Cum in self/loose soil getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 CM, watering and removing surplus soil, to a distance n.exc. 50 M. and making good surplus complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
S&F framed work as in door or gates of angle or other section with gusset places, rails, braces etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including hooks, hinges complete all as specified and directed by Engineer-in-Charge. (for tree guard)
S&F Welded steel wire fabric n. exc 4kg per sqm in weight, complete to wood or steel members complete all as directed.
Preparation of two coats of synthetic enamel paint on new steel surfaces of any description, over 10cm in width or girth,not otherwise described including preparation over a coat of red oxide Zinc chrome prime complete all as specified and directed complete all as specified and directed.
Total carried over to BOQ Rs.
Signature of Contactor
Item No 20 : Construction of brick masonry valve pit of size 1200 mm x 1200mm x 900 mm (internal dimensions) with one brick thick wall in cement mortar 1 : 4 on 100 mm thick PCC 1:4:8 type D2 (using 40mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in benching and coping and 10mm thick cement plaster in CM (1:4) internally and externally upto 15cm below ground level providing valve pit cover 40x40x6mm angle iron frame all-round fixed by means of 4 Nos holdfast 150mm long made out of flat iron 40x6mm embedded in PCC block (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) of size 230x200x100mm incl provn of hinges welded with angle iron frame and MS cover 3mm thck sheet, MS handle of suitable length and size welded with MS cover and suitable locking arrangement and applying two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation and earth work in soft/loose soil complete all as shown on drawing and as specified.
INCOMING
(Cooling Appliances)
Each job
Total carried over to BOQ Rs.
Signature of Contactor
Earthing complete with galvanised steel earth plate 60×60cm ×3.15mm thick electrode earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32×6mm by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), cast iron frame, funnel with wire mesh,GI watering pipe of 20 mm bore medium grade and lugs, with and including galvanised iron strip 32×6mm with GI protection pipe of 15 mm medium grade 7.5 meter long, etc complete all as specified.
M/L for Demolition of road/path /concrete in ground floors and pavings PCC 1:2:4 type B1 n exc 15 cm thickness (below or above ground level) .complete all as specified and as directed.
(b) 25mm bore
(c ) 20mm bore
Supply & fix aluminium strips 25x3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as directed by Engr - in - Charge .
S&F test point terminal block made out of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw , drolled , cutting upper & lower portion for incoming & outgoing including double insulators two coat of synthic enamel paint complete as directed .
Supply and fix air termination rod single pointed aluminium rod length 12 mm dia & 300 mm long .
M&L for 100 mm thick PCC 1:2:4 TYPE B1 using 20mm graded stone aggregate as in floor.
Supply and errect vertically Galvanised, medium grade pipe 20 mm diameter complete with fittings for raising height for air termination rods all as specified and directed.
Total carried over to BOQ Rs.
Signature of Contactor
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
BOQ_819713.xls
BOQ • 0.52 MB
tender.pdf
Tender Documents • 5.32 MB
C1.pdf
PDF • 0.14 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .