Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance PLOT NO 33 34 SAINAGAR NAGOLE HYDERABAD 500 068 | MEDCHAL MALKAJGIRI | TELANGANA | 500068 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance PLOT NO 28 SANTOSHIMA COLONY WEST MARREDPALLY SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | Admitted-Finance |
| 4 | Rejected-Technical | Rejected-Technical Not enlisted in requisite category |
| 5 | Rejected-Technical | Rejected-Technical Not enlisted in requisite category |
Tender Value
₹48.2 L
EMD Value
₹96,400
Closing Date
3 Jul 2025, 6:00 pmClosed
GE(I) R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
PROVISION OF PARKING SHED IN FRONT OF HPL BUILDING AT CHESS HIGH MAST LIGHTS AND ALLIED WORKS AND REPAIR REPLACEMENT OF LIFT AGAINST BER AT AVC BUILDING AT RCI HYDERABAD
2025_MES_713647_1
8284
Open Tender
Civil Works
Item Rate
335 days
GE(I) R AND D RCI
MES enlisted Class D category a i, b i and c ii Un enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT
8 documents required · 8 mandatory
₹500
Yes
GE(I) R AND D RCI, HYDERABAD
₹96,400
Yes
15 Jul 2025
12 Jun 2025
5 Jul 2025
12 Jun 2025
3 Jul 2025
26 Jun 2025
Amount
Excavating holes in all kinds of soil more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil, as directed within a lead of 50 m and lift upto 1.5 m
P & L 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work upto plinth level 1:2:4(1 cement 2 ccoarse asand (zone iii) derived from naturalsources 4 grade stone aggregate 20mm nominal size derived from natural sources
Centering and shuttering including strutting propping etc and removal of form for lintless, beams, plinth beams, girders bressumers and cantileversfoundations, footings bases of columns etc for mass concrete
Providing and laying upto to floor five level reinforced cement concrete in foundation, columns and beams and the like excluding the cost of centering shuttering finishing and reinforcment with 1:1.5:3(1 cement, 1.5 coarse sand and(zone-III) and 3 coarse aggregate stone 20mm nominal zize derived from natural sources)
S&F steel reinforcement for R C C work including straigthening cutting bending placing in position and binding all complete upto pinth level, TMT bars of grade Fe 500 D or more
S&F steel reinforcement for R C C work including straigthening cutting bending placing in position and binding all complete upto above pinth level (lintle bend roof beam and slab etc), TMT bars of grade Fe 500 D or more
M&L Brick work with Sub class 'B' bricks straigh or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed
15mm thick rendering in CM 1:4 on other than fair faces of brick work or concrete surfaces and finished the surface fair and even with water proofing compound minimum 2% without using extra cement complete (Note WPC will be paid seperately)
Distermpering with oil bound washable distemer of approved brand and manufacture to give an even shade . New work (two or more coats) over and including water thinable priming coat with cement primer Sqm complete all as specified and directed
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Removing excavated soil to a distance n.exceeding 50m and depositing where directed at level n.exc 1.5m above starting pont complete all as specified and directed
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Provising and fixing bolts inluding nuts and washers compete
S&F, Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Painting with synthetic enamel paint two or more coats on new steel work of approved brand and manufacture to give an even shade over a priming coat wth ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works complete all as specified and as directed.
Taking down of old unserviceable LT Cable of any size all as specified and directed
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area laid in trenches / duct or fixed to wall / passing through pipe on pole with suitable size cable glands, crimping type cable lugs for stranded aluminum conductor of following sizes complete all as specified and directed :-
(a) 4 core X 25 Sqmm
(b) 3.5 Core X 35 Sqmm
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting ou
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed. Note :- Thickness of sand cushion after punning down shall be measured as 18cm for payment purpose.
M & L for brick protection cover of old size bricks common burnt clay building bricks sub class ’B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent bricks not exceeding 10 mm complete all as specified.
M & L cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling including excavation for laying of cable pipe all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
Supply & fix, LED floodlight 150W system lumens 18000lm, luminaire with pressure die cast aluminium (ADC12) housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT > 5700K, IP 66 optical and electrical compartment i.e. Built-in potted driver & impact resistance of complete luminaire > IK07. Power Factor >0.95 with mains, Surge Protection- Min 10KV along with Over voltage/ Overload, short circuit/ miss-wiring protection with other safety test as per IS 15885 Part-2/Sec 13. Universal Voltage driver to operate wide voltage range from 100 V to 270V, 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB . LED Light fixture with 150W System Power consumption. LED Efficiency> 120m/w, nominal CRI >70. Luminaire manufacturer should have in- house facility accredited by NABL certified agency & Design & Development facility certified by ISO 9001:2008. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V acomplete all as specified and as directed by Eng-in-charge . Make :Havells/Phillips/Crompton
M&L for repairing of 16.5/20.0m long high mast system with the help of suitable equipment tools and plants(crane) and wiring of luminaries with all wiring material and labour.The scope of work includes the following :- a) Dismantling completely the high mast system 20m height b) Checking of wire rope and pulleys c) Lantern carriage luminaries repairing d) Checking of winch motor operation and complete lubrication Notes: 1) The quoted rate is deemed to include for labour charges including crane and minor repairs. 2) Necessary spares which are required will be measured and paid for separetely under relevant items.
Dismantling complete existing highmast with foundation and M&L for repairing of 16.5/20.0m long high mast system with the help of suitable equipment tools and plants(crane) and wiring of luminaries with all wiring material and labour.The scope of work includes the following :- a) Foundation bolts manufactured from special steel along with nuts, washers, anchor plates and templates complete all as directed by Engr-in-Charge. (b) The Aviation obstruction light LED type (c) Design and casting of suitable shallow foundation with M-25 design mix concrete for high mash considering the safe soil bearing capacity of soil as 10T/Sqm at min1.2 meters depth / as recomended by manufacturer , How ever the soil bearing capacity be checked/ confirmed as per site condition and got approved by the GE before commencement of work d) Checking of wire rope and pulleys e) Lantern carriage luminaries repairing f) Checking of winch motor operation and complete lubrication Notes: 1) The quoted rate is deemed to include for labour charges including crane and minor repairs. 2) Necessary spares which are required will be measured and paid for separetely under relevant items.
Supply and fix stainless steel wire rope of 6 mm dia 7/19 construction to fix high mast lantren and two point suspention mechanism complete all as speciefed and directed.
Supply laying, passing through high mast pole & testing PVC insulated PVC sheathed cable galvanized steel strip or wire armoured electric control cable (Heavy duty) with stranded copper conductor of size 2.5 sqmm, 5 core.
Taking down, transport to workshop , Re-winding of electric motor 3 phase installed at highmast pole of capacity upto 0.5/1 HP and refixing of the same including necessary arrangement complete all as directed
Supply and fixing of LT FEEDER PILLAR BOX BOTH SIDE OPENABLE with projected Globe roof for rain water protection,manufactured by a CPRI approved Manu-facturer Dust and Vermin Proof , suitable for 440 Volt 3 Phase 4 Wire System made out of 3.00 mm thick CRCA Sheet of size .75MX.75MX.40M and built upon Rigid Frame Work having Front and Rear hinged double shutter Doors with Neoprene Rubber Gasket, Epoxy Powder Coated including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeded with 50X6mm Mild Steel Angle Iron Frame and 600mm above the Normal Ground Level comp -lete with PCC Foundation in Cement Concrete 1:2:4 (20mm Graded Stone Aggregate) and Test-ing after Installation complete all as specified and comprising of the following :– (for controlling of hIgh mast light)
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI med grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC 1 : 3 : 6 type C-1 , 50 mm thick pre cast RCC 1 : 2 : 4 type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar ,GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 5 of MES SSR Part-I and including taking down old one complete.
Material and labour for taking down old existing unserviceable / BER passenger lift capacity 408 Kg to serve upto 3 floors (G+2 floors) ground plus two floors complete all as directed. Design, Supply, installation, commissioning & testing of 544 Kg/ 8 persons passenger lift (SS HONEY COMB FINISH WITH HALF VISION PANNEL DOORS WITH TOUCH PANEL) with shaft speed 1 mtr/sec,travel height 7.3 meter lift with single speed motor 415 volts, 3 phase, AC 50 HZ supply confirming to IS-14665, suitable to serve 3 stops & 3 openings(G+2 floors), Single entrance car with AC variable voltage & variable frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with / without attendant, centre opening doors with drive (electric motor driven mechanism, sliding stainless steel doors, automatic rescue device (ARD) system 3D infra red sensor in full height of door & built in voice announcing system without hand set in car, without machine room & near ground floor with landing door complete all as specified. Note :- Old unserviceable Lift & Lift accessories will be deposited to E/M store yard. Make: KONE/SCHINDLER/OTIS
CONTROLLER (LCB): Microprocessor based LSVF closed loop controller with VVVF drive unit for existing duty load, speed, stops and simplex full collective operation with incorporation of features like, Auto Rescue Device (ARD), energy efficiency, non fire lifts, enclosure meeting with the standards of EMC (Electo Magnetic Compatibility), Automatic by-pass, overload device, Automatic self levelling, Alarm bell/buzzer, Anti Nuisance, New reference system in hoist ways suitable for the new LSVF controller including magnets, cams and limit switches with mounting accessories and protection.
LIFT CAR CABIN : (a) Car frame/ sling fabricated from suitable steel angle or channel section all as per IS. (b) Car roof, provided with a car top rail / balustrade and suitable warning notice for fall hazard. (c) Car cabin (Dimentions:1300 mm wide x 1100 mm deep x 2200 mm high) enclosures and false ceiling with stainless steel (SS 304) hairline finish or / and stainless steel (SS 304) Scratch Resistant finish and flooring with granite / marble colour, texture, Design as approved by Engr-in-Charge. (d) Noiseless pressure fan or blower provided in lift cabin with supply grill matching with the interior of the cabin. (e) Recess mounted LED lighting and in addition to normal lighting and emergency light unit using sealed Nickel/Cadmium Maintenance freee battery power pack with charger and LED lamp to operate automatically and to illuminate the car for minimum 30 minutes in case of power failure. (f) Round Bend Handrail Silver brushed stainless steel (ST4) at Rear Wall fabricated with polished stainless steel at height & locations suitable for physically challenged passengers. (g) scratch resistant cabin enclosure at least one third of the size at middle portion on rear panel through out the height of the cabin. (h) Car cabin:SS silver brushed, Door type :Two-panel centre opening Vision Panel with Honey comb finishes (i) Dimentions :Well Dimension: 2450 mm width and 2015 mm depth, Head Room height:4690 mm , Pit Height:1600 mm , MAP Floor Position: Topmost floor (TOP), Door dimensions 900 mm wide x 2000 mm internal height
CAR OPERATING PANEL : Touch type Stainless Steel "Car Operating Panel" with the following devices. (a)Car Door Finish:Vision Panel with Honey comb finishes along with Additional Features: Yes Gong in Car, Emergency Rescue Device with audio announcer, Nudging service, Lift Announcer, Square Spot Light LED, 1 Hour Fire rated for landing door. (b) Alarm button, provided with a yellow pictogram to indicate the alarm button provision. (c) Fan / Blower switch. (d) Door open and close button. (e) The main floor / exit floor push button, protruded 5 mm beyond the other floor buttons with illumination. (f) "Up" & "Down" direction indicators indicating travel direction. (g) Key operated switch for "Attendant" and "Automatic" operation. (h) Overload panel along with audio / visual indication. (i) Door hold button, which extends normal door open period by up to 30 seconds. The extended time can be cancelled by actuation of door close button. (j) / scrolling digital car position indicator with LED / LCD illumination indicating the landing at which the car is stopped or passing.
(k) Hall buttons combined with digital position indicator with SS hairline finish face plate suitable for simplex full collective operation at lobby floor of all landings (G+2 floor) (l)Car Panel Finish:- Side walls: Honeycomb textured Stainless Steel, Rear wall: Honeycomb textured Stainless Steel ,Front wall: Honeycomb textured Stainless Steel (m) Ceiling & Lighting: Integrated roof LS4 Stainless Steel Square Spot Light LED. (n) Flooring: 20 mm Customer provide Granite Stone Car skirting material: Stainless steel Hairline AISI441, Floor number: 1 TO 3, Floor Mark: 0,1,2 (o) Interfloor distance: 3650 mm (p) Landing door material: Vision Panel with Honey comb finishes, Car operating panel: 1 Full Height Dark grey brushed stainless steel (ST16) Tempering glass Segmented LCD display Round flush mounted KDS96 (q) Landing Signalization: Tempering glass (TG) Segmented LCD display Flush Mounted Tempered glass Round,flush mounted KDS96.
CAR & LANDING DOORS: (a) The landing doors complete with headers, sills, frames etc. as required and entrances for lifts protected by automatic power operated, center opening, with finishing matching with car ( Stainless steel scratch Resistant finish), single skin construction all as per IS. (b) Positive acting Door Drive powered by A.C. motor rigidly connected to the door and controlled by a VVVF unit and simultaneously open the car and landing doors and maintain the doors fully open or closed at each landing (G+2 floor), suitable for Attendant / Automatic operation and smooth opening of door without any jerk and closing of door without any banging noise, mounted on steel members forming part of the car sling. (c) A multiple beam full height infrared electronic door detector, to regulate the closing motion of the doors for entry of the passengers. (d) Each landing door to be provided with an interlock, to prevent movement of the car away from the landing until the doors are locked in the closed position with an electric contact for the door to prevent car movement away from the landing unless the door is in fully closed position. (e) The car and the landing doors are to be provided with two point suspension sheave type hangers complete with tracks. Sheaves and rollers of steel with moulded nylon collar and shielded ball bearings and the tracks of suitable steel section with smooth surface.
DRIVING SHEAVES, GOVERNOR ROPES AND SUSPENSION ROPES: (a) Self lubricated, round standard wire ropes manufactured from high grade steel and special flexible material the combined breaking strength calculated with factor of safety . (b) The end of the lift ropes, properly secured to the the car and counter weight hitch plates as the case may be with adjustable rope shackles having individual tapers babbit sockets and with a suitable shackle spring, seat washer, shackle nut & lock & shackle nut split pin or any other suitable arrangement. Note: The Contractor has to produce test certificate for the ropes.
VOICE SYNTHESIZER : Digital type capable of site programming, giving a choice of background music (with option at the site to choose or reject) and capable of providing following messages in English language. "Arrival at the floor & its designation".
HOISTWAY HARNESS AND TRAVELLING CABLES: (a) hoist way harness and travelling cables suitably suspended to relieve strains in individual conductors suitable for closed loop controller and fixtures, run from a junction box on the top of the car to a junction box located in the shaft bear mid point of travel and from these junction boxes conductors run to the various locations. (b) Travelling cables shall be provided for signals, controls, lights, fans, alarm bell, emergency circuit and music .Extra 10 percent of the total capacity .
PIT LADDER & SWITCHES: (a) Fixed pit ladders between the bottom landing and the pit floor, safe from all falling hazards. (b) Two pit stop switches, with mushroom red head ( it shall be locked off when pushed and reset manually) one at bottom landing level in the shaft & the other on the pit (First stop switch shall be accessible from the lower landing on opening of the landing door and the second switch from the pit floor) which when in the STOP position, shalll prevent any movement of the lift car including movement during inspection operation, until both the switches are set in the run POSITION. (c) Terminal limit switches, to slow down and stop the car automatically at the terminal landings and final limit switches to automatically cut off power should the car travel beyond the terminal landings. (d) Fireman switch at lobby floor. (e) Safety operated switch. (f) intercom.
Standard Specifications includes: (a) Correction drive to next level,(b) Emergency Alarm @ Main Floor , (c)Car Call backwards,(d) Overload function, (e) constant indication/Buzzer,(f) Bypass load Function, (g) Auto Cut off Fan and Light,(h) Manual Rescue Operation,(i) Centralized Hoisting for lesser vibration and smooth travel, (j) Pit Ladder, (k) Micro movement Led Based Buttons, (l) L.W.D. (Load Weighing Device), (m) Direction & Position Indicator In Car & Landing, (n) Advanced Car Position Indication, (o) Automatic Brake Test function every 11hours, Every run brake supervision,(p) Phase reversal functioning, (q) Signal Fixtures, +10% to –10% Voltage Fluctuation Withstanding Capacity, (r) Door Close Button, (s) Door Open Button, (t) Car Emergency Light, (w) Fireman Drive, (x) Curtain of Light 169 Beams, (y) Accurate Relevelling, (z) Automatic, Closed Door, Car door lock
Note: (a) The contractor should visit the site to assess the exact scope of work prior to quoting the tender. (b) The rate quoted shall be inclusive of the following : (i) Fixing car and counter weight brackets,allingnment of guide rails and fixing counter weight frame , car frame with balancing couter weights.. Complete machine unit over speed governor (OSG), necessary machine fixing channels. (ii) Additional safety aspects for machine room (First Aid Box, Co2 / Foam based fire hydrant cylinders, Danger plates, Rubber mats in front of each controller. Electric shock treatment charts and any other safety item that may be required by authorities) and in lift car including lift identification plates and DOS AND DONTS plates made of SS with engraved letters in English language as directed by Engineer-in-Charge. (iii) Two galvanized iron 32X6 mm size earth strips running all along the hoist way and from machine room to earth pit including connecting from necessary terminals and suitable clamps completre. (iv) Painting of all lift metal work with one shop coat of rust inhibiting paint in the factory and painted with finishing coats on site. (v) Civil works involving fixing landing operating panel, Landing fascia, guide rails, sills limit switches, embedding in wall etc. complete.
(vi) The charges for obtaining Lift fitness certificate per year for a period of minimum two years from the Lift Inspector of the Telanga state. (vii) Design and Engineering Fabrication, Manufacturing, Inspection and testing, packing forwarding, transportation to site, unloading at site, transportation, Erection and Commissioning, trial run and carrying our Performance / Acceptance Tests at site and Handing over of complete Elevator. (viii) 24 months warranty & AMC from the date of handing over of elevator from OEMS only. (ix) Civil and structural works, Architraves for all landings, Single &Three Phase Permanent power supply upto Head/Machine room, Reducer Channels, if required, Bulk Head lighting in lift shaft.size),MCBS AT Head/Machine room.Two earthing lines & Earth Bars upto Head/Machine room.Scaffolding,Dismantling of old lift,Hoisting beam &Load hooks etc. complete all as directed and specified. (c) Any civil / architectural / structural damage or changes (if any) to walls / floors/ architraves / fascades / ceilings / doors that the contractor may cause during work process will have to be rectified to its original form at his own cost, risk and responsibility. (x) Contractor shall produce 24 months warranty certificate from the date of installation of lift from OEM.
Supplying and fixing following modular switch 6A on the existing modular plate & switchbox including connections but excluding modular plate etc. as required.
Supplying and fixing following modular socket 2 module 3/5 pin 6A on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Supplying and fixing following modular switch 16A on the existing modular plate & switchbox including connections but excluding modular plate etc. as required.
Supplying and fixing following modular socket 6 pin 16A on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 12Module (200mmX150mm) modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
S&F in replacement, recess mounting 36W, 4x1 LED luminaire suitable for Armstrong/Grid ceiling with high performance LEDs complete with all accessories including driver pre-wired complete all as specified. Make: Havells Cat No: VENUSNEOHE4X1PLR36WLED 857S or Techno commercially equivalent in Philips/Wipro. NOTE -A)Any accessories or frame required for proper fixing of light fixture will be provided by contractor without any extra cost. B) If ceiling cutting required skilled labour will be provided by contrator for proper fixing and finish after installation of light without any extra cost.
Supplying and fixing Wall mounting air circulators 400mm sweep,230V Complete all as specified and directed
Universal refrigeration and Engineering Company (BID ID -3345562)
BEKKAM CONSTRUCTIONS (BID ID -3345506)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .