Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 LAccepted-Finance 1128 SECTOR 22 B NEAR AROMA PETROL PUMP CHANDIGARH UT 160022 UDYAM CH 01 0016982 04AACCT5404E1ZV B R MII STATUS AS NOT VERIFIED | CHANDIGARH | CHANDIGARH | 160022 | ₹2.1 L | L1 | Accepted-Finance L1 |
| 2 | L2₹2.2 LRejected-Finance 315 INDUSTRIAL AREA II PANCHKULA 134113 | PANCHKULA | HARYANA | 134113 | ₹2.2 L | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical 1090 GROUND FLOOR SECTOR 18 C CHANDIGARH | - | - | Rejected-Technical Not qualified technical bid |
Updated dates
Tender Value
₹2.5 L
EMD Value
₹5,000
Closing Date
30 Apr 2026, 12:00 pmClosed
Er. Chander Shekhar
Office of the Executive Engineer, Electrical Division No. 3 Sector-4, Chandigarh.
PROVIDING CONSTRUCTION OF EXTENSION BLOCK IN DISPENSARY (HEALTH AND WELLNESS CENTRE), SECTOR-11, UT, CHANDIGARH (MANUAL FIRE ALARM SYSTEM.
2026_CHD_91814_1
E3/47W/14
Open Tender
Electrical Works
90 days
Chandigarh
AS PER NIT
2 documents required · 2 mandatory
₹0
₹5,000
10 Jun 2026
17 Apr 2026
30 Apr 2026
17 Apr 2026
30 Apr 2026
17 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
DSR 28.1.11 Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. Each 52258.00 6 zone panel for fire alarm system 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required- 2 Nos.(one to act as standby) Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set. Announcement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set. Amplifier change over switch for inter changing amplifier- 1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No. Gooseneck microphone with stand and ON/OFF switch -1 No. Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required -1 set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt, 30 AH each sealed maintenance free batteries -1 set. | - | - | - | - | |
Two Loop Panel. | - | Each | - | - | |
DSR Item No. 28.2.14 Supplying, installation, testing & commissioning of addressable manual call point complete as required. | - | Each | - | - | |
DSR Item No. 28.3.3Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. | - | Each | - | - | |
Supplying and installation of Red/ Green LED laser etched emergency exit signage double sided pedant type made out or powder coated MS housing and etched acrylic sheet indicator with reflective light source>2 W LED, emergency backup of min. 4 hours, 6 V 3.2 AH SMF/ SLA battery, SMPS power supply suitable for operation on 230 AV 50 Hz AC supply as per the requirement at all prominent locations to guide the way out of the building to the building users in case of fire. The size of the letter should be sufficient for visibility of the people as per MBC-2016. The exit sign board should be of Thorn/ Prolite/ Auto Glow/ Autolite/ Glowlite/ Honeywell make only. | - | Each | - | - | |
DSR Item No. 28.5.2Supplying & laying of 2x1.5 sq mm fire alarm armored cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required. | - | P.Mtr. | - | - | |
DSR 1.20 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required | - | - | - | - | |
25 mm | - | P.Mtr. | - | - | |
Providing AMC for fire alarm system. under the AMC the supplier shall provide comprehensive Maintenance service of the fire alarm including the spares & there shall be no hidden cost, preventive Maintenance service of the equipment under AMC must be carried out once in fortnight. During the period of AMC service/repair calls are to be attended by the supplier within two hours from the time of such calls. The defective equipment should be repaired on the same day at purchaser’s location. In case of major defects requiring the defective card/item/equipment to be taken to the supplier workshop. It should be returned within a weeks’ time duty repaired & immediate substitute card/item/equipment will be provided by the supplier for the smooth operation of the fire sensing system. The to &frotransportation of the card/item/equipment will be the responsibility of the supplier. Delays in attending the calls & or repairing the defective equipment be yond time limit of one day will attract penalty @ Rs.500/-per day. The bidder will undertaken the supplies of necessary Maintenanceequipment & spare parts will be made available for all the equipment & the complete system for a period of 5 years on continuing basis 1st year free & thereafter for four year on paid basis. The bidder shall quote the rate on per year basis. | - | - | - | - | |
AMC for 2nd year @ 5% | - | P.Year | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 25.66 MB
BOQ_112329.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid