Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC NEAR JAMIA MASJID HOSPITAL ROAD UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹7.2 L+₹16,260 (2.31%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹9.6 L+₹2.6 L (36.9%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | Rejected-Technical | - | Rejected-Technical Due to HQ CENC declared Unenlisted and Unenlisted document are not submitted. | |
| 5 | Rejected-Technical | - | Rejected-Technical Due to NO remark in WLR QE Mar 2023 of HQ CEUZ. |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
29 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(I) 873 EWS
Garrison Engineer (Indep) 873 Engineer Works Section PIN 913 873 C/O 56 APO
REPAIR / MAINTENANCE RO PLANTS, SOLAR WATER HEATING SYSTEM AND OTHER CONNECTED WORK AT GHATIMORE, KAPRA, BHALRA, CHINTA, NASKA, DUGGA, CHINCHORA AND JAIGHATI UNDER GE (I) 873 EWS
2023_MES_603746_1
NIT-30 of 2023-24
Open Tender
Civil Works
Item Rate
270 days
Bhaderwah
As per NIT
7 documents required · 7 mandatory
₹500
GE(I) 873 EWS
₹20,000
Yes
12 Sept 2023
16 Jun 2023
1 Aug 2023
16 Jun 2023
29 Jul 2023
17 Jul 2023
Amount
On-site Repair / Maintenance and Servicing of RO/filteration plants by dismantling, checking all parts i.e. Pre-filter, granular activated carbon block filter, membrane, UV disinfection / filtration system, adaptor, pressure pump set, main pump motor, solenoid valve, flow controller, all gauges, filling of anti-scalent liquid, checking functioning of all type meters, electric wiring, contactors & relay, switches, valves and replacement of old unserviceable parts, checking of leakages of any part of plants and pipe line by new parts and pipe line including re-assembling the same as original and reinstalling at same place including re-connecting with the existing water supply system and testing at full capacity discharge of filtered water complete all as specified and as directed of the following description :- (a) RO Plant of 25 Ltrs/Hours capacity
(b) RO Plant of 50 Ltrs/Hours capacity
(b) RO Plant of 100 Ltrs/Hours capacity
(e) RO Plant of 2500 Ltrs/Hours capacity Notes for Serial Item No 1 :- (i). Spare parts required for replacement of the defective parts to make the RO Plant fully functional shall be measured and paid separately under appropriate item of this Schedule as 'Supply only'. (ii). The Contractor will ensure that all RO plants are functional throughout the contract period by detailing his technical team once in each quarter though out the contract period for servicing and maintenance.
(iii). In the eventually of any RO plants not working after the last service and before the next service, the contractor will attend the complaint within 72 hours of intimation of the complaint through SMS / e-mail / WhatsApp message from JE (E/M) / AGE (E/M). The Visit charge due to any such complaint shall be deemed to be included in the quoted rates against Serial item No 36 & 37 and nothing extra shall be admissible on this account. (iv). In case the Contractor fails to attend the complaint and does not make the plant serviceable within stipulated time frame of 72 hours, a Panel Recovery of `500.00 per day per plant will be deducted for each day of delay. (v). The Contractor may claim part payment for each quarter as per the work done. Contractor shall produces Job card duly indicating details of parts replaced duly signed by the User Rep, JE (E/M) & AGE (E/M).
Supply only Bib tap 20mm bore standard of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 125 grams), complete all as specified and directed.
Supply only Bib tap 15mm bore standard of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 90 grams), complete all as specified and directed.
Supply only Stop Valve, cast copper alloy, 20mm bore, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., complete all as specified and directed.
Supply only Stop Valve, cast copper alloy, 15mm bore, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., complete all as specified and directed.
Supply only PVC tubing of 14mm bore, complete all as specified and directed. Make : Renuka/ Kent / Eureka Forbes
Supply only PVC tubing of 12mm bore, complete all as specified and directed. Make : Renuka/ Kent / Eureka Forbes
Repair / Maintenance of feeding Pump of 0.37KW to 0.5HP installed in RO plant at various location by disconnecting of RO plant carefully for repair, rewinding with super enamelled copper winding wire of suitable size, greasing, change of capacitor, bearing etc and reassembling of pump at its original position, complete all as specified and directed.
Repair / Maintenance of Pressure Pump of 1 to 2 HP installed in RO plant at various location by disconnecting of RO plant carefully for repair, rewinding with super enamelled copper winding wire of suitable size, greasing, change of capacitor, bearing etc and reassembling of pump at its original position, complete all as specified and directed.
Supply and fix in replacement of feeding Pump suitable for small water filtration plant of rating 0.37 KW/ 0.5 HP, 230 volts, 50 Hz, Single Phase, 20 meter head and discharge rate 40 LPM, complete all as specified and directed. Make : Crompton Greaves / Kirloskar / Siemens
Supply only Pressure Pump suitable for small water filtration plant of rating 0.75/1.0 KW/HP, 230 volts, 50 Hz, 3 stage & discharge rate 750 LPH, complete all as specified and directed. Make : Crompton Greaves / Kirloskar / Siemens
Supply only Pressure Pump suitable for small water filtration plant of rating 1/1.50 KW/HP, 230 volts, 50 Hz, 5 stage and discharge rate 750 LPH, maximum head 47 meter, complete all as specified and directed. Make : Crompton Greaves / Kirloskar / Siemens
Supply only Pre-Filter (Micronic Filter) candle of following size, complete all as specified and directed. (Make : Renuka / Kent / Eureka Forbes) (a) RO Plant of 25 Ltrs/Hours capacity
(b) RO Plant of 50 Ltrs/Hours capacity
(c) RO Plant of 100 Ltrs/Hours capacity
Supply only Carbon block Filter of following size, complete all as specified and directed. (Make : Renuka / Kent / Eureka Forbes) (a) RO Plant of 25 Ltrs/Hours capacity
(b) RO Plant of 50 Ltrs/Hours capacity
(c) RO Plant of 100 Ltrs/Hours capacity
Supply only Media Cylinder/water treatment vessel of following capacity, complete all as specified and directed. (Make : Renuka / Kent / Eureka Forbes) (a) RO Plant of 25 Ltrs/Hours capacity
(b) RO Plant of 50 Ltrs/Hours capacity
(c) RO Plant of 100 Ltrs/Hours capacity
(d) RO Plant of 2500 Ltrs/Hours capacity
Supply only Membranes of following capacity, complete all as specified and directed. (Make : Renuka / Kent / Eureka Forbes) (a) RO Plant of 25 Ltrs/Hours capacity
(b) RO Plant of 50 Ltrs/Hours capacity
(c) RO Plant of 100 Ltrs/Hours capacity
Supply only new Adaptors of following capacity, complete all as specified and directed. (Make : Renuka / Kent / Eureka Forbes) (a) RO Plant of 25 Ltrs/Hours capacity
(b) RO Plant of 50 Ltrs/Hours capacity
(c) RO Plant of 100 Ltrs/Hours capacity
Supply only ultra violet rays (UV) panel of RO plant, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
Supply only ultra violet bulb (UV) for any capacity of RO plant, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
Repair / maintenance / replacement of control panel and its parts inclusive paint, making identification marks of all indicators like pressure gauge, Ammeter, Voltmeter etc all defective parts to be replaced and make in serviceable codition all as specified and directed. (Note:- All required replacement of parts in panel will be inclusive in quoted rate of this job. No extra cost of parts will be pay to contractor)
Supply only distributor handle of following capacity, complete all as specified and directed. (Make : Renuka / Kent / Eureka Forbes / Hi Tech) (a) RO Plant of 25 Ltrs/Hours capacity
(b) RO Plant of 50 Ltrs/Hours capacity
(c) RO Plant of 100 Ltrs/Hours capacity
(d) RO Plant of 2500 Ltrs/Hours capacity
Supply only flow restrictor adjuster of following capacity, complete all as specified and directed. (Make : Renuka / Kent / Eureka Forbes) (a) RO Plant of 50 Ltrs/Hours capacity
(b) RO Plant of 50 Ltrs/Hours capacity
(c) RO Plant of 100 Ltrs/Hours capacity
Supply only anti-scalant dosing punp with connecting flexible pipe complete all as specified and directed. (Make : Renuka / Kent / Eureka Forbes)
Repair / servicing of chemical dosing electric operated at site replacement of unservieable spares ie. NRV, inlet outlet pipe, strainer, foot valve, regulator, indicator switch as required and make in serviceable codition all as specified and directed. (Note:- All required replacement of parts will be inclusive in quoted rate of this job. No extra cost of parts will be pay to contractor)
Supply only micronic shell (Filter housing) of size 20 inch complete all as specified and directed. (Make : Renuka / Kent / Eureka Forbes)
Supply only micronic shell (Filter housing) of size 10 inch complete all as specified and directed. (Make : Renuka / Kent / Eureka Forbes)
Supply only Anti-scalant Liquid (membrane protector), complete all as specified and directed. (Make : Renuka / Kent / Eureka Forbes)
Supply only elbow for CPVC of 1/2 inch size, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
Supply only elbow for CPVC of 3/4 inch size, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
Supply only CPVC union of 1/2 inch size, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
Supply only CPVC union of 3/4 inch size, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
Supply only capacitor of 10 MFD, complete all as specified and directed. Make : L&T / ABB / Siemens / GE
Supply only Solenoid Valve, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
Supply only CPVC pipe Adhesive, complete all as specified and directed.
Supply only Taflon Tape for RO, complete all as specified and directed.
Supply & Filling Chlorine Dosing Tank of RO/Filtration plaant of SUPER CHLOR TOTAL a solution of Hypochlorous Acid (HOCL) for chlorination of drinking water disinfection solution having residual effect, clear colour less and potent germicide non corrosive and non foaming stable upto 100 degree C for drinking water as and when required in HDPE jericane of 35 Ltrs capacity having the following features (Make : Renuka Tech) (a) Potent germicide (b) Slime control (c) High residual effect to avoid contaminator (d) Less Hazardous (e) Work at low dosage in post disinfection (f) No after taste. (g) Most reliable in operation (h) Eco friendly and biodegradable
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Galvanised iron pipe of the following size medium grade with all fittings such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc. supplied and laid in trenches/on walls / floors / ceilings wih clamps complete all as specified and directed Make : Jindal / TATA / Prakash Tubes
(a) 50mm bore
(b) 40mm bore
(c) 25mm bore
(d) 20mm bore
(e) 15mm bore
Dismantling and refixing the complete unit of unserviceable solar water heater Capacity 100 LPD plate with new solar water heater plate of the following installed at various sites complete overhauling, cleaning, servicing all serviceable accessories including repairing/ replacing of all defective parts such as copper tubes, toughned glass, hot water tank, nuts, bolts, wasahers and all other minor accessories as required at site including painting to solar water heater by rubbing the old paint and applying with two coats of synthetic enamelled paint by spray painting and testing the same after repair, complete all as specified and directed (Note: Replacement of spares shall be measured and paid for seperately.)
Supply only the following items / spares in replacement for Solar Heaters of various capacities complete all as specified :- (a) Heating element (Electric rod) of capacity upto 2 KW having rubber washer of size 1 ¼” or 1 ½” complete.
(b) Heating element (Electric rod) of capacity upto 1.5 KW having rubber washer of size 1 ¼” or 1 ½” complete.
(b) Glycol (Anti freezing solution) for filling in copper tubes complete.
(c) Toughened glass 6mm thick for collector for heat transmission including making connection
(d) Make up water tank
(e) Coupling gasket
(f) Temp Gauge 0 degree centigrade to 120 degree centigrade
(g) Dead flange with nut, bolts and washers complete.
(h) Float valve assembly 15mm dia complete.
(j) Thermostat suitable for solar heater complete.
Supply and fixing Gun metal globe / gate valve ISI Marked with and including jointing meterial and taking out old unserviceable valves complete all as specified and directed of following sizes :- Make : Advance / Bir / Leader / Sant/ RAMCO
(a) 40mm bore
(b) 25mm bore
(c) 20mm bore
(d) 15mm bore
S&F in replacement MCB SP 6 to 32 Amp 10 KA 240 Volts, 50 Hz, 'C' curve complete all as specified and directed. (Make : ABB / Siemens / Legrand/ Havells / Scheinder)
S&F in replacement MCB SPN 32 Amp 10 KA 240 Volts, 50 Hz, 'C' curve complete all as specified and directed. (Make : ABB / Siemens / Legrand/ Havells / Scheinder)
S&F in replacement MCB SPN 40-63 Amp 10 KA 240 Volts, 50 Hz, 'C' curve complete all as specified and directed. (Make : ABB / Siemens / Legrand/ Havells / Scheinder)
S&F in replacement MCB TPN 25 to 63Amp 10 KA 240 Volts, 50 Hz, 'C' curve complete all as specified and directed. (Make : ABB / Siemens / Legrand/ Havells / Scheinder)
S&F in replacement Sheet metal enclosure factory made single door for DB 240 volts with 200 Amps rated bus bar SPN 4 Way and making good disturbed surfaces of walls, complete all as specified and directed.
M&L in replacement Sub main wiring with two single core PVC insulated multistranded un-sheathed FRLS cable of size 4.0 Sqmm with stranded copper conductor, drawing into PVC ccasing caping of size 20/30mm and accessories) with continuous PVC insulated multistranded unsheathed FRLS cable earth wire of 2.5 Sqmm dia including taking out unserviceable sub main wiring, complete all as specified and directed. Note : Two run of 4.0 Sqmm wire, one run of 2.5 Sqmm wire and one run of PVC casing caping shall be considered as one unit length.
Note for all items : If any complaint which inform to the contractor by AGE or JE through telephone or verbal direction and the same will not attend by the contractor within one day, failing which a penalty of Rs 1000/- per day will be imposed.
R C TRADERS
SWASTIK TRADERS
Bidder Name
SWASTIK TRADERS
CITY TOP ELECTRICAL WORKS
R C TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .