Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 LAccepted-AOC 3712 3714 PHASE IV G IDC VATVA AHMEDABAD GUJARAT 382445 | AHMADABAD | GUJARAT | 382445 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L1₹80.2 LAccepted-AOC 1 B R W COMPOUND NEAR UNIVERSAL BUSINESS PARK OFF SAKI VIHAR ROAD ANDHERI EAST MUMBAI MAHARASHTRA 400072 | MUMBAI SUBURBAN | MAHARASHTRA | 400072 | L1 | Accepted-AOC L1 Bidder | |
| 3 | L2Rejected-Finance 1312 CHIRANJIV TOWER NEHRU PLACE NEHRU PLACE SOUTH DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | L2 | Rejected-Finance L2 Bidder | |
| 4 | L2Rejected-Finance 160 BABA NAGAR VILLIVAKKAM TIRUVALLUR TAMIL NADU 600049 | THIRUVALLUR | TAMIL NADU | 600049 | L2 | Rejected-Finance L2 Bidder |
Tender Value
Refer Docs
Closing Date
17 Apr 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Mr. Nilesh Sathe
thyssenKrupp Industrial Solutions (India) Private Limited (Formerly Uhde India Private Limited) Uhde House, L B S Marg, Vikhroli (W), Mumbai - 400083, India
SUPPLY OF STRAINERS FOR P25 PROJECT AT IOCL PANIPAT REFINERY
2023_REFHQ_164361_1
6745-PPM-000-CA-PI66
Limited
Mechanical - Piping, materials, flanges, valves, seals
Supply
150 days
IOCL Panipat Refinery
Please refer Tender documents.
6 documents required · 6 mandatory
Exempted
20 Mar 2024
21 Mar 2023
18 Apr 2023
21 Mar 2023
17 Apr 2023
30 Mar 2023
SUPPLY OF STRAINERS
STRAINER Y-TYPE,SS, 600,0, MFG. STD., FLGD,B16.5,RF, BOLTED COVER, REMOVABLE SCREEN., PERFORATED PLATEASTM E674, MESH ASTM E0216, MESH SIZE 40 MESH, SHALL BE PROVIDED WITH 3/4", THREADED TAP AND SOLID, THREADED PLUG AS DRAIN CONN., A351 GR.CF8M, STR.ELEMENT SS 316, ET SP WD SS316 + GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.CLEAR STRAINER AREA TO NOMINAL, AREA RATIO SHALL BE 3(AT, UNCLOGGED CONDITION).
STRAINER Y-TYPE,CS (IBR), 150,0, MFG. STD., FLGD,B16.5,RF, BOLTED COVER,REMOVABLE SCREEN., PERFORATED PLATE ASTM E674, MESH ASTM E2016, MESH SIZE40 MESH, SHALL BE PROVIDED WITH 3/4", THREADED TAP AND SOLID, THREADED PLUG AS DRAIN, FOR STRAINER SIZE, 2" AND ABOVE AND 1/2" DRAIN, FOR BELOW 2"., A216 Gr.WCB, STR.ELEMENT SS 304, ET SP WD SS316 + GRPH, A193 Gr.B7/A194Gr.2H, COVER A216 Gr.WCB, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED, 3.CLEAR STRAINER AREA TO NOMINAL AREA, RATIO SHALL BE 3(AT UNCLOGGED CONDITION)
STRAINER Y-TYPE,CS, 800,0, MFG. STD., SW ENDS,B16.11, Y TYPE , REMOVABLE SCREEN, PERFORATED PLATE ASTM E674, MESH ASTM E2016, MESH SIZE 40 MESH, A105N, INTERNALS SS304, ET SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.CLEAR STRAINER AREA TO NOMINAL AREA, RATIO SHALL BE 3(AT UNCLOGGED CONDITION)
STRAINER Y-TYPE,CS, 800,0, MFG. STD., SW ENDS,B16.11, Y TYPE , REMOVABLE SCREEN, PERFORATED PLATE ASTM E674, MESH ASTM E2016, MESH SIZE 40 MESH, A105N, INTERNALS SS304, ET SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.CLEAR STRAINER AREA TO NOMINAL AREA, RATIO SHALL BE 3(AT UNCLOGGED CONDITION)
STRAINER Y-TYPE,CS (H2 SER.), 800,0, MFG. STD., SW ENDS,B16.11, Y TYPE , REMOVABLE SCREEN, PERFORATED PLATE ASTM E674, MESH ASTM E2016, MESH SIZE MESH 40, A105N, INTERNALS SS 304, ET SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002., 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004.
STRAINER Y-TYPE,CS (NACE+H2), 800,0, MFG. STD., SW ENDS,B16.11, Y TYPE , REMOVABLE SCREEN, PERFORATED PLATE ASTM E674, MESH ASTM E2016, MESH SIZE 40 MESH, A105N, INTERNALS MONEL, ET SP WD SS316+GRPH, A193Gr.B7M/A194Gr2HM, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005, 3.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004, 4.CLEAR STRAINER AREA TO NOMINAL AREA, RATIO SHALL BE 3(AT UNCLOGGED CONDITION)
STRAINER Y-TYPE,SS, 800,0, MFG. STD., SW ENDS,B16.11, Y TYPE , REMOVABLE SCREEN, PERFORATED PLATE ASTM E674, MESH ASTM E2016, MESH SIZE 40 MESH, A182 Gr.F316, INTERNALS SS 316, ET SP WD SS316+GRPH, A193GR.B7/A194GR.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
STRAINER Y-TYPE,AS, 800,0, MFG. STD., SW ENDS,B16.11, Y TYPE , REMOVABLE SCREEN, PERFORATED PLATE ASTM E674, MESH ASTM E2016, MESH SIZE 40 MESH, A182 Gr.F9, INTERNALS SS 316, ET SP WD SS316+GRPH, A193 Gr.B16/A194Gr.4, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
STRAINER Y-TYPE,CS (IBR), 800,0, MFG. STD., SW ENDS,B16.11, Y TYPE , REMOVABLE SCREEN,, PERFORATED PLATE ASTM E674, MESH ASTM E2016, MESH SIZE40 MESH, A105N, INTERNALS SS304, ET SP WD SS316 + GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED, 3.CLEAR STRAINER AREA TO NOMINAL AREA, RATIO SHALL BE 3(AT UNCLOGGED CONDITION)
STRAINER Y-TYPE,CS (IBR), 800,0, MFG. STD., SW ENDS,B16.11, Y TYPE , REMOVABLE SCREEN,, PERFORATED PLATE ASTM E674, MESH ASTM E2016, MESH SIZE40 MESH, A105N, INTERNALS SS304, ET SP WD SS316 + GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED, 3.CLEAR STRAINER AREA TO NOMINAL AREA, RATIO SHALL BE 3(AT UNCLOGGED CONDITION)
BASKET STRAINER,AS, 300,0, MFG. STD., FLGD,B16.5,RF, DESIGN BASKET TYPE, DRAIN & VENT CONN. 2",FLGD,RF, THE DRAIN SHALL BE PROVIDED AT, THE SIDE OF THE STRAINER AT, THE BOTTOM., NORMALIZED & TEMPERED,, MESH ASTM E2016, MESH MESH 40, PERFORATED PLATE ASTM E674, A234 Gr.WP9-W, WN FLG A182 GR.F9, TOP COVER A182 GR.F9, SPWD SS316 + GRPH, A193 Gr.B16/A194Gr.4, SCREEN SS 316, OTHER INTER. EQUIVALENT TO, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
STRAINER T-TYPE,CS, 150,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS SS304, SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA
STRAINER T-TYPE,CS, 150,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS SS304, SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA
STRAINER T-TYPE,CS, 150,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS SS304, SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA
STRAINER T-TYPE,CS, 150,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS SS304, SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA
STRAINER T-TYPE,CS, 150,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS SS304, SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA
STRNR T-TYPE,CS,INT EPOXY COAT, 150,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, INTERNAL EPOXY COATED, A234 Gr.WPB-W, INTERNALS SS304, SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA, 4.FOR INTERNAL COATING REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0023
STRNR T-TYPE,CS,INT EPOXY COAT, 150,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, INTERNAL EPOXY COATED, A234 Gr.WPB-W, INTERNALS SS304, SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA, 4.FOR INTERNAL COATING REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0023
STRNR T-TYPE,CS,INT EPOXY COAT, 150,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, INTERNAL EPOXY COATED, A234 Gr.WPB-W, INTERNALS SS304, SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA, 4.FOR INTERNAL COATING REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0023
STRNR T-TYPE,CS,INT EPOXY COAT, 150,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, INTERNAL EPOXY COATED, A234 Gr.WPB-W, INTERNALS SS304, SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA, 4.FOR INTERNAL COATING REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0023
STRAINER T-TYPE,CS (NACE), 150,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-W, INTERNALS SS 316L, SP WD SS316+GRPH, A193Gr.B7M/A194Gr2HM, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA, 4.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
STRNR T-TYPE,CS,INT EPOXY COAT, 150,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, INTERNAL EPOXY COATED, A234 Gr.WPB-S, INTERNALS SS304, SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA, 4.FOR INTERNAL COATING REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0023
STRAINER T-TYPE,CS (NACE), 150,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS SS 316L, SP WD SS316+GRPH, A193Gr.B7M/A194Gr2HM, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA, 4.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
STRAINER T-TYPE,CS (NACE), 150,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS SS 316L, SP WD SS316+GRPH, A193Gr.B7M/A194Gr2HM, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA, 4.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
STRAINER T-TYPE,CS (NACE+H2), 150,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS MONEL, SP WD SS316+GRPH, A193Gr.B7M/A194Gr2HM, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA, 4.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005, 5.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
STRAINER T-TYPE,CS, 150,0, TKIS DRAWING, BW ENDS,SCH XS, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS SS304, SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA
STRAINER T-TYPE,CS (NACE+H2), 150,0, TKIS DRAWING, BW ENDS,SCH XS, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS SS304, SP WD SS316+GRPH, A193Gr.B7M/A194Gr2HM, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA, 4.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005, 5.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
STRAINER T-TYPE,CS (NACE), 150,0, TKIS DRAWING, BW ENDS,SCH XS, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS SS 316L, SP WD SS316+GRPH, A193Gr.B7M/A194Gr2HM, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA, 4.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
STRAINER T-TYPE,CS (NACE+H2), 150,0, TKIS DRAWING, BW ENDS,SCH XS, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS MONEL, SP WD SS316+GRPH, A193Gr.B7M/A194Gr2HM, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA, 4.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005, 5.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
STRAINER T-TYPE,CS, 300,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS SS304, SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA
STRAINER T-TYPE,CS, 300,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS SS304, SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA
STRAINER T-TYPE,CS, 300,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS SS304, SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA
STRAINER T-TYPE,CS, 300,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS SS304, SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA
STRAINER T-TYPE,CS, 300,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS SS304, SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA
STRAINER T-TYPE,CS, 300,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS SS304, SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA
STRAINER T-TYPE,CS (H2 SER.), 300,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS SS304, SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA, 4.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
STRAINER T-TYPE,CS (H2 SER.), 300,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS SS304, SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA, 4.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
STRAINER T-TYPE,CS (H2 SER.), 300,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS SS304, SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA, 4.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
STRAINER T-TYPE,CS (NACE), 300,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS SS316L, SP WD SS316+GRPH, A193Gr.B7M/A194Gr2HM, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA, 4.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
STRAINER T-TYPE,CS (NACE+H2), 300,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS SS316, SP WD SS316+GRPH, A193Gr.B7M/A194Gr2HM, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA, 4.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005, 5.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
STRAINER T-TYPE,CS (NACE+H2), 300,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS MONEL, SP WD SS316+GRPH, A193Gr.B7M/A194Gr2HM, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA, 4.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005, 5.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
STRAINER T-TYPE,CS, 300,0, TKIS DRAWING, BW ENDS,SCH XS, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS SS304, SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA
STRAINER T-TYPE,CS, 300,0, TKIS DRAWING, BW ENDS,SCH XS, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS SS304, SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA
STRAINER T-TYPE,CS (H2 SER.), 300,0, TKIS DRAWING, BW ENDS,SCH XS, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-W, INTERNALS SS304, SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA, 4.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
STRAINER T-TYPE,CS (NACE), 300,0, TKIS DRAWING, BW ENDS,SCH XS, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-W, INTERNALS SS316L, SP WD SS316+GRPH, A193Gr.B7M/A194Gr2HM, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA, 4.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
STRAINER T-TYPE,CS (NACE), 300,0, TKIS DRAWING, BW ENDS,SCH XS, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-W, INTERNALS SS316L, SP WD SS316+GRPH, A193Gr.B7M/A194Gr2HM, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA, 4.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
STRAINER T-TYPE,CS (NACE), 300,0, TKIS DRAWING, BW ENDS,SCH XS, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS SS316L, SP WD SS316+GRPH, A193Gr.B7M/A194Gr2HM, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA, 4.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
STRAINER T-TYPE,CS (NACE), 300,0, TKIS DRAWING, BW ENDS,SCH XS, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-S, INTERNALS SS316L, SP WD SS316+GRPH, A193Gr.B7M/A194Gr2HM, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA, 4.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
STRAINER T-TYPE,CS, 300,0, TKIS DRAWING, BW ENDS,SCH NON-STD, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-W, INTERNALS SS304, SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA
STRAINER T-TYPE,CS (NACE), 300,0, TKIS DRAWING, BW ENDS,SCH NON-STD, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WPB-W, INTERNALS SS316L, SP WD SS316+GRPH, A193Gr.B7M/A194Gr2HM, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA, 4.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
STRAINER T-TYPE,CS, 600,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, A234 GR.WPB-S, INTERNALS SS 304, SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA
STRAINER T-TYPE,CS, 600,0, TKIS DRAWING, BW ENDS,SCH 80, DESIGN DRAWER TYPE, FLANGED COVER, A234 GR.WPB-S, INTERNALS SS 304, SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA
STRAINER T-TYPE,CS, 600,0, TKIS DRAWING, BW ENDS,SCH XS, DESIGN DRAWER TYPE, FLANGED COVER, A234 GR.WPB-S, INTERNALS SS 304, SP WD SS316+GRPH, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA
STRAINER T-TYPE,AS, 300,0, TKIS DRAWING, BW ENDS,SCH XS, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WP5-S CL.1, INTERNALS SS 316, GASK SP WD SS316+GRPH, A193 Gr.B16/A194Gr.4, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA
STRAINER T-TYPE,AS, 300,0, TKIS DRAWING, BW ENDS,SCH NON-STD, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WP5-W CL.1, INTERNALS SS 316, GASK SP WD SS316+GRPH, A193 Gr.B16/A194Gr.4, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA
STRAINER T-TYPE,AS, 300,0, TKIS DRAWING, BW ENDS,SCH STD, DESIGN DRAWER TYPE, FLANGED COVER, NORMALIZED & TEMPERED, A234 Gr.WP9-S CL.1, INTERNALS SS 316, GASK SP WD SS316+GRPH, A193 Gr.B16/A194Gr.4, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA
STRAINER T-TYPE,AS, 300,0, TKIS DRAWING, BW ENDS,SCH XS, DESIGN DRAWER TYPE, FLANGED COVER, NORMALISED AND TEMPERED, A234 Gr.WP9-S CL.1, INTERNALS SS 316, GASK SP WD SS316+GRPH, A193 Gr.B16/A194Gr.4, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA
STRAINER T-TYPE,AS, 600,0, TKIS DRAWING, BW ENDS,SCH 160, DESIGN DRAWER TYPE, FLANGED COVER, A234 Gr.WP9-S CL.1, INTERNALS SS 316, GASK SP WD SS316+GRPH, A193 Gr.B16/A194Gr.4, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. FOR STRAINER DIMENSIONAL DETAILS, REFER DOC. 6745-PIP-000-TB-0008, 3.MESH 5 WITH 0.041 in. DIA. WIRE AND 63%, OPEN AREA. THE EFFECTIVE AREA OF THE, SCREEN ASSEMBLY SHALL NOT BE LESS THAN, 150% OF THE PIPE CROSS SECTIONAL AREA
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .