MAJOR AJIT CHOUDHARY
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore State West Bengal Pin 721303
REPAIR AND MAINTENANCE OF SUMMER, COOLING APPLIANCES, INTERNAL WIRING, FANS, FITTINGS FIXTURE, DG SET, FIRE ALARM SYSTEM, EARTHING INFRASTRUCTURE AND OTHER ALLIED WORKS AT AF STN SALUA UNDER GE (AF) KALAIKUNDA
2023_MES_601938_1
C/8878/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
AF STN SALUA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF KALAIKUNDA
₹99,400
Yes
28 Jul 2023
8 Jun 2023
14 Jul 2023
8 Jun 2023
13 Jul 2023
24 Jun 2023
Amount
Comprehensive servicing for Window Type Air Conditioner of any make and capacity installed at various location by carrying out necessary repairs,cleaning of filters, adjustments of assemblies, sub-assemblies, check the level of refrigerant, arresting the leakage of any type, replacement of parts, calibration including cleaning of condensor & evaporator coils fins with mild detergent and descaling of condensor coil for window etc. through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed. MAKE LG/Carrier/Samsung/Amtrex/Videcon/Hitachi/Blue star
Comprehensive servicing for Split Type Air Conditioner of any make and capacity installed at various location by carrying out necessary repairs,cleaning of filters, adjustments of assemblies, sub-assemblies, check the level of refrigerant, arresting the leakage of any type, replacement of parts, calibration including cleaning of condensor & eveporator coils fins with mild detergent and descaling of condensor coil for Split etc. through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed. (NOTES:- (Applicable for BOQ Serial Item No. 1 to 2 here in before) (i)S&F spare parts will be measured and paid separately under relevant item.) (ii) The Contractor shall provide the following comprehensive services arising out of wear and tear of the normal running of Air Conditioners including maintenance of all mechanical, electrical and electronic parts /sub-assemblies. The preventive maintenance report will be as per the Original Equipment manufacturer's instructions and as specified in Particular Specification. (iii) Breakdown Maintenance : The Authorised Service Engineer of OEM or OEM Certified Agencies will carry out all breakdown maintenance after receiving information (written or oral) from GE (AF) KALAIKUNDA officials or their representatives, The OEM's authorised service representative or OEM certified agencies will carry out the required repairs of the units and appraise GE,Engineer-in-Charge and JE the status of the break down repair at site. No payment shall be made on account of any breakdown service during maintenence period including defect liablity period . (iv) The Service Engineer will be called in case of any breakdown and the same shall be attended within 24 Hours of lodging of complaint, failing which a penal recovery of Rs.200.00 (Rupees Two Hundred Only) per day till such time the unit is attended and complaint is resolved,will be recovered from the outstanding dues to the Contractor. (v) Cost of minor items like teflon tape,insulation tape, metal washers, fibre/rubber washers, screws, small nuts & bolts and like shall be deemed to be inclusive of the quoted rate. (vi) Spares required for replacement of defective ones will be measured and paid seperately .Each maintenance job shall be covered period of 09 Months
Shifting of split type AC from MES yard / existing location to the new location, filling the opening of old location with cement mortor, applying white wash on wall with existing colour of the site and making opening holes on brick wall at new location, well finish with cement mortor (1:3) , applying white wash, distemper etc on wall to match with existing colour of the adjacent surface , installation and commissioning with replacement of insulation of suction & discharge line as per OEM recommendation complete all as directed
Shifting of window type AC from MES yard / existing location to the site/ new location where directed & installation by making necessary opening of brick wall/ window and preparing gap well finished by cement mortor(1:3) applying white washing or as per existing finish in matching with the existing colour, disposal of waste material/ filling gap with ply wood on front side of AC and outer corner of ply wood applying two coats of enamelled paint over a coat of primer on plywood surface to match the existing location all as directed by the Engr-in-Charge.
Comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations Water Cooler of any make and capacity installed at various locations by carrying out necessary repairs, adjustments of assemblies, sub-assemblies, check the level of refrigerant, arresting the leakage of any type, replacement of parts, calibration etc. through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE, including refixing the same at the location where directed including making/connecting of water and electric connection complete all as specified and dierected. Make of water cooler : Voltas/Bluestar/Shriram/Videocon or any make.
Comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations 165 to 340 Litres capacity refrigerators installed at various locations by carrying out necessary repairs,adjustments of assemblies, sub-assemblies, check the level of refrigerant, arresting the leakage of any type, replacement of parts, calibration etc. through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE, complete all as specified and directed. [Make: LG/Voltas/Godrej/Kelvinator/Whirlpool/Blue Star]
Supply and fixing in replacement of Printed Circuit Board suitable for 2TR Capacity Split Unit Air Conditioners including remote, as per OEMs specifications, complete suitable for existing type etc all as directed by Engr in charge .
All as per Srl item No 07.00 here-in-before but for 1.5 TR Capacity Split Unit Air Conditioners including remote, as per OEMs specifications, complete suitable for existing type etc all as directed by Engr in charge . . Make LG/equivalent as approved by GE
Disconnecting, dismantling and taking out existing burnt out compressor from window/Split type Air conditioner 2 TR Capacity and supply and fixing sealed unit compressor of existing capacity 2 TR, single phase, 230 V AC supply initialy filled with compressor oil as per OEMs specifications, and testing on load for 24 hrs in summer complete all as specified and as directed Note Contractor has to submit purchase voucher and warranty certificate from OEM before submission of his claim to department.
All as per srl item No. 8.00 here-in-before but Cap 1.5 TR Single phase 230 volts AC 50 Hz complete all as specified and as directed Note Contractor has to submit purchase voucher and warranty certificate from OEM before submission of his claim to department.
All as per srl item No 8.00 here-in-before but suitable for water cooler of capacity 40 to 60 Ltr per Hour single phase 230 volts supply complete all as specified and as directed .Note Contractor has to submit purchase voucher and warranty certificate from OEM before submission of his claim to department.
All as per srl item No. 8.00 here-in-before but suitable for water cooler of capacity 80 to 120 Ltr per Hour single phase 230 volts supply complete all as specified and as directed .Note Contractor has to submit purchase voucher and warranty certificate from OEM before submission of his claim to department.
Disconnecting, dismantling & taking out existing burnt out compressor from domestic type refrigerator Cap upto 286 Ltr S&F hematically sealed compressor unit as per OEMs specifications, existing Make & model including initial charging of sealed compressor with refrigerant gas & testing on load on 24 hrs for smooth functioning complete all as specified and as dire cted Note Contractor has to submit purchase voucher and warranty certificate from OEM before submission of his claim to department.
All as per Ser Item No. 12.00 here-in-before but suitable for Cap 300/310 Ltrs per hrs single phase 230 volts AC supply complete all as specified and as dire cted Note Contractor has to submit purchase voucher and warranty certificate from OEM before submission of his claim to department.
All as per Ser Item No. 12.00 here-in-before but suitable for chest type Deep freezer Cap 300 Ltrs per hrs single phase 230 volts AC supply complete all as specified and as dire cted Note Contractor has to submit purchase voucher and warranty certificate from OEM before submission of his claim to department.
All as per Ser Item No. 12.00 here-in-before but suitable for chest type Deep freezer Cap 500 Ltrs per hrs single phase 230 volts AC supply complete all as specified and as directed Note Contractor has to submit purchase voucher and warranty certificate from OEM before submission of his claim to department.
Supply & fixing in replacement of AC blower fan motor for AC suitable for 2 TR AC s as per OEMs specifications,suitable for operation on 230 Volt AC supply at 50 HZ complete all as specified and as directed Note Contractor has to submit purchase voucher and warranty certificate from OEM before submission of his claim to department.
All as per Ser Item No.17.00 here-in-before but suitable for 1.5 TR AC window type AC suitable operate on 230 Volt AC supply at 50 HZ complete all as specified and as dire cted Note Contractor has to submit purchase voucher and warranty certificate from OEM before submission of his claim to department.
All as per srl item No.17.00 here-in-before but suitable for water cooler of Cap 40/80 Ltrs complete all as specified and as dire cted Note Contractor has to submit purchase voucher and warranty certificate from OEM before submission of his claim to department.
All as per Srl item No 17.00 here-in-before but suitable for water cooler of Cap 150 Ltrs complete all as specified and as dire cted Note Contractor has to submit purchase voucher and warranty certificate from OEM before submission of his claim to department.
Supply & fixing in replacement of Capacitor 4 MFD as per OEMs specifications,complete all as specified and as directed
Supply & fixing in replacement of Capacitor 36 MFD as per OEMs specifications,complete all as specified and as directed
Supply & fixing in replacement of Capacitor 45+6 MFD as per OEMs specifications,complete all as specified and as directed
Supply & fixing in replacement of Capacitor 50/55+5 MFD as per OEMs specifications,complete all as specified and as directed
Supply & fixing in replacement of Thermostat switch for water cooler/Window AC as per OEMs specifications,complete all as specified and as directed
Supply & fixing in replacement of Drier stainer filter suitable for AC/Water cooler/Refrigertor as per OEMs specifications,complete all as specified and as directed
S&F in replacement of single pole and neutral enclouser with a two pin and earth plug and socket complete with one MCB single pole 20/25 Amps as per OEMs specifications,complete all as specified and as directed
S&F in replacement of Elastomeric Nitrile Foam Rubber 1/6'' size as per site requirement of approved as per OEMs specifications,complete all as specified and as directed
All as per Srl item No 28.00 here-in-before but 1/8'' size as per site requirement of approved make all as spd and directed .
All as per Srl item No 28.00 here-in-before but 5/8'' size as per site requirement of approved make all as spd and directed .
S&F in replacement of Copper pipe of size 1/4'' of approved as per OEMs specifications,complete all as specified and as directed
All as per item No 31.00 here-in-before but size 1/2'' of as per OEMs specifications,complete all as specified and as directed
All as per item No 31.00 here-in-before but size 5/8'' of approved make as per OEMs specifications,complete all as specified and as directed
S&F in replacement of overload relay 1/6 or 1/8 type as per OEMs specifications,complete all as specified and as directed
All as per item No 34.00 here-in-before but size 4/10 type of approved make as per OEMs specifications,complete all as specified and as directed.Note Contractor has to submit purchase voucher and warranty certificate from OEM before submission of his claim to department.
M&L for copper codensing coil for Refrigerator 310 ltrs as per existing make/size as per OEMs specifications,complete all as specified and as directed Note Contractor has to submit purchase voucher and warranty certificate from OEM before submission of his claim to department.
M&L for copper codensing coil for 2 TR/1.5 TR split type AC as per existing size all as per OEMs specifications,complete all as specified and as directed Note Contractor has to submit purchase voucher and warranty certificate from OEM before submission of his claim to department.
S&F in replacement of Evaporator unit (indoor unit ) complete suitable for 2 TR Capacity Split type Air Conditioners as per OEMs specifications,complete all as specified and as directed Note Contractor has to submit purchase voucher and warranty certificate from OEM before submission of his claim to department.
S&F in replacement of Evaporator unit (indoor unit ) complete suitable for 1.5 TR Capacity Split type Air Conditioners as per OEMs specifications,complete all as specified and as directed Note Contractor has to submit purchase voucher and warranty certificate from OEM before submission of his claim to department.
S&F in replacement of Out door unit complete excluding compressor etc. Suitable for 2 TR Capcity Air conditioners as per OEMs specifications,complete all as specified and as directed Note Contractor has to submit purchase voucher and warranty certificate from OEM before submission of his claim to department.
S&F in replacement of Out door unit complete excluding compressor etc. Suitable for 1.5 TR Capcity Air conditioners as per OEMs specifications,complete all as specified and as directed Note Contractor has to submit purchase voucher and warranty certificate from OEM before submission of his claim to department.
Supply and fixing in repair Capillary tube size 50 / 60 Suitable for split/ window type AC of capacity 1.5/2.0 Ton as per OEMs specifications,complete all as specified and as directed
Supply and fixing in repair Bracket stand suitable for 2 TR Capacity Split type AC including Fastners, as per OEMs specifications,complete all as specified and as directed
Supply and charging R-22 gas to maintain the required cooling effect as and when required in the split AC/ window type AC & other cooling applinces (charging cost included in this items deemed to be quoated rates) as per OEMs specifications complete all as specified and as directed
Supply and charging R-134 gas to maintain the required cooling effect as and when required in the water cooler, Refrigerator and other cooling applinces incl (charging cost included in this items deemed to be quoated rates) as per OEMs specifications complete all as specified and as directed
Supply and charging Nitrogen Gas for finding out lekage as and when required (charging cost included in this items deemed to be quoated rates)(charging cost included in this items deemed to be quoated rates) as per OEMs specifications complete all as specified and as directed
S&F in replacement of wall mounted voltage stabilizer 4/5 KVA single phase , 230 volts suitable for ACs as per OEMs specifications complete all as specified and as directed
Supply & fixing in replacement of Copper cable flexible 3 core 4 Sqmm. complete all as specified and as directed
Supply & fixing in replacement of Copper cable flexible 3 core 6 Sqmm.complete all as specified and as directed
Taking down old AL/Copper Sub main wirng and M&L for new Sub main wiring using two single core PVC insulated cable(HR&FR) 6 sqmm copper conductor multi stranded and 6.0 sqmm copper conductor insulated cable (HR&FR)using as earth wire and drawing into PVC Casing and Caping complete all as specified and directed .Note- One run of PVC casing caping , 03 run of 6 sq mm PVC copper wire measured as one Unit
Taking down carefully, existing defective storage type water heater (geyser) of any Capacity and Make for repairing, including replacement of defective spares as required and including replacement of terminals with defective connection wires and reinstallation of the geyser in original position including testing and commissioning, complete all as specified and directed. ( NOTES:- (i) Repairs shall be carried out through authorised technicians of the OEMs as approved by GE. (ii) Spares for replacement will be measured and paid separately. )
Supply only heating element any type (i.e; Cup,thread or triangular) as per existing sample 1.5 KW, 220/230 volts ISI marked as per OEMs specifications, complete.
Supply only heating element any type (i.e; Cup,thread or triangular) as per existing sample 2.0 KW, 220/230 volts ISI marked as per OEMs specifications, complete
Supply only Thermostat switch ISI marked as per OEMs specifications, complete Make: Alcone or equivalent
Supply only Head Assy"Brass" 8 to 9 holes suitable for 25 ltrs capacity as per OEMs specifications, complete
Supply only Head Assy"Brass" 8 to 9 holes suitable for 50 ltrs capacity as per OEMs specifications, complete.
Supplyonly Safety plug "brass" ISI marked suitable for 25/50 ltrs geyers as per OEMs specifications, complete
Supply only Hot water connection made of brass pipe,chromium plated upto 18" length complete with rubber washer & brass nuts, ISI marked as per OEMs specifications, complete
Supply only MS outer cover (body) for storage type water heater of capacity 25 Ltrsas per OEMs specifications, complete
All as per srl item No.59.00 here-in-before but water heater capacity of 50 ltrs as per OEMs specifications, complete
Supply only geyser inner assembly of brass with inlet/outlet & over flow provision rubber washer suitable for 25 ltrs capacity as per OEMs specifications, complete
As per Ser No 61.00 here-in-before but suitable for capacity 50 Ltrs as per OEMs specifications, complete
S&F in replacement of bottom cover plate in two halves suitable and as per sample as per OEMs specifications, complete
S&F phase indicator red colour circular/rectangular shape as suitable and as per sample complete as per OEMs specifications, complete
S&F in replacement of non return brass valve of 15mm bore, ISI marked as specified and directed by Engr-in-Charge.
S&F in replacement of plug top 3 Pin 15 Amps 230 volts all as specified and directed by Engr-in-Charge.
Supply only glass wool as per OEMs specifications, complete
Taking down carefully (copper/aluminium) point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants regulators sub main wiring, light fittings etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster or tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
Taking down carefully copper/ aluminium submain wirings of any size (2 runs single core including earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed.
Materials and Labour for point wiring with 1.50 Sq. mm (nominal area) (FRLSH) as per IS 694: 2010 PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including 25mm wide double locking type PVC casing and capping complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) (FRLSH) PVC as per IS 694: 2010 insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for :-Note : Wiring to be done as per approved IE rules colour code.
One light point controlled by one switch
One fan point controlled by one switch
One 3 Pin 5 Amps socket outlet independent
One 3 Pin 5 Amps socket outlet on the same board with other switch
One bell point controlled by one switch
Materials and Labour for point wiring with 2.50 Sq. mm (nominal area) (FRLSH) PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing and capping complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switch socket outlet etc and including 2.50 Sq. mm (nominal area) (FRLSH) PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one 3 Pin 15 Amps socket out let independent, complete all as specified and directed.(i)Wiring to be done as per aproved colour code.
M & L for concealed point wiring with and including single core PVC insulated, unsheathed flexible conductor (FRLSH) cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor (FRLSH) cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end for the following complete all as specified and as directed. (Note: (i) The chases in the wall shall be cut with elect cutter and rates of the same will deemed to be included in quoated rates (ii) The disturbed surfaces of wall shall be made good with cement plaster 1:4 including matching the surfaces with as per existing finishes and to the entire satisfaction of Engineer in Charge):- (iii)Wiring to be done as per approved colour code in IE rule.
One light point controlled by one switch
One fan point controlled by one switch
One 3 Pin 5 Amps socket outlet independent
One 3 Pin 5 Amps socket outlet on the same board with other switch
One bell point controlled by one switch
Materials and Labour for concealed type point wiring with 2.5 Sq. mm (nominal area) (FRLSH) as per IS 694: 2010, ISI marked PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, drawn in and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switch socket outlet etc and including 2.50 Sq. mm (nominal area) (FRLSH) PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one 3 Pin 15 Amps socket out let independent, complete all as specified and directed.(Note: (i) The chases in the wall shall be cut with elect cutter and rates of the same will deemed to be included in quoated rates (ii) The disturbed surfaces of wall shall be made good with cement plaster 1:4 including matching the surfaces with as per existing finishes and to the entire satisfaction of Engineer in Charge):- (iii)Wiring to be done as per approved colour code in IE rule.
Supply and fix switch piano, flush button, single pole, one way, 5 Amps, complete all as specified and directed.
Supply and Fix,switch socket combination 2 in 1, 5A,flush type, complete all as specified and directed.
Supply and Fix,switch socket combination 3 pin 5A/16A, 5 in 1 flush type, complete all as specified and directed.
S&F, bell electric, Ding Dong AC. 230 volts, single pole complete all as specified and directed.
Supply and fix ,bell push, flush type, single pole, 5 Amps, complete all as specified and directed.
Supply and Fix , Modular Switch, one way, 6 Amps, 1 Module, complete all as specified and directed.
Supply and Fix , Modular Switch, one way, 16 Amps, 1 Module, complete all as specified and directed.
S & F modular socket outlet, 6Amps, 2 and 3 pin combined two modules complete all as specified.
S & F modular socket outlet, 6Amps/ 16 Amps, 2 and 3 pin combined two modules complete all as specified.
Supply and Fix , Modular Fan step regulator, 120W - 2 module,complete all as specified and directed.
S&F in repair stepped type electronic fan regulator 100 watt flush type (delux) on the existing hylem laminated sheet etc as required complete all as specified and directed by Engr-in- charge.
Supply and fix Ceiling Rose, three terminal, PVC/ Polycarbonate insulated body, complete all as specified and directed.
Supply and Fix in repairs, Modular Bell switch , 6 Amps, 1 Module, complete all as specified and directed.
Supply and fix Polycarbonate angular lamp holder with back plate, suitable for batten fittings complete all as specified and directed.
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 4.0 Sqmm as per IS 694: 2010, ISI marked (with colour code), drawn in but including PVC casing caping not less than 25 mm width, ISI marked, double locking type including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 4.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface complete all as specified and directed .
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 6.0 Sqmm as per IS 694: 2010, ISI marked (with colour code), drawn in but including PVC casing caping not less than 25 mm width, ISI marked, double locking type including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface complete all as specified and directed .
Supply and Fix, double door, sheet metal enclosure for DBs for mounting of MCB for 415 Volts, 4 way, with 200 Amps rated bus bar, Triple Pole & Neutral, including dismantling taking down unserv. DB complete all as specified and directed [Cat No.DBTPE004DD of Make L&T or equivalent Model of Make Legrand/Siemens]
Supply and Fix, Single Door, Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts, 2 way, with 100 Amps rated bus bar, Single Pole & Neutral, fixed in repairs, including blanking plate complete all as specified and directed. [ Make Legrand or equivalent Model of Make L&T/ Seimens]
Supply and Fix, Double Door, Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts, 8 way, with 100 Amps rated bus bar, Single Pole & Neutral, fixed in repairs including blanking plate , complete all as specified and directed. [Cat No. 5076 11 of Make Legrand or equivalent Model of Make L&T/ Seimens]
Supply and Fix, Double Door, Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts, 4 way, with 100 Amps rated bus bar, IK09 Single Pole & Neutral, fixed in repairs, including blanking plate complete all as specified and directed. Make Legrand or equivalent Model of Make L&T/ Seimens]
Supply and Fix, miniature circuit breaker (MCBs) Single pole and neutral, 240 Volts, 10KA, 63 Amps C-curve ,as per IS 60898-1 2002 complete all as specified and directed.
Supply and fix in repair miniature circuit breaker (MCBs) single pole & neutral, 240 Volts, 10KA, 40 Amps,C-curve complete all as specified and directed. [Cat No. 4086 18 of Make Legrand or equivalent Model of Make L&T/ Seimens]
Supply and fix in repair miniature circuit breaker (MCBs) triple pole, & neutral, 415 Volts, 10KA, 63 Amps,C-curve complete all as specified and directed. Make Legrand/ L&T/ Seimens]
Supply and fix in repair miniature circuit breaker (MCBs) triple pole, & neutral, 415 Volts, 10KA, 40 Amps,C-curve complete all as specified and directed. Make Legrand/ L&T/ Seimens]
Supply and Fix, miniature circuit breaker (MCBs), single pole, 240 Volts,10KA,,C-curve 6-32 Amps complete all as specified and directed.
Supply and Fix, miniature circuit breaker (MCBs), single pole, 240 Volts,10KA,,C-curve 63 Amps complete all as specified and directed.
S & F in repair single pole and neutral enclosure with two pin and earth, plug and socket, suitable for single phase 240 V,complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking capacity 10 KA, including industial plug top, complete all as specified and as directed. Make : Legrand cat part No. 607841 or equivelent in Schinder/ L&T.
Taking down existing panel light fitting any type (600 mm x 600 mm) recess mounting/surface and S&F LED light fitting 36 watt recess mounting of size 600 mm x 600 mm , LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 4000, lumen efficacy of minimum 115 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, ITHD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95, CRCA powder coated white after phosphochromate treatment housing, life span of minimum 50000 working hours including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmm x 3 core complete all as specified and directed by EIC.
S&F LED 9/10 Watt tube light fitting intergated type, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 100 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours complete suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.5 sqmm three core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed. Make :- Bajaj/ /Wipro/Philips as approved by GE
S&F LED 20 Watt tube light fitting (T8 type) ,single/double side connection type including LED retrofit tube lamp 20 W , LED tube light nominal power 20 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2100, lumen efficacy of minimum 100 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours as per catalogue No Make :- Bajaj (Batten Cat No. BLRB DB 118 box type batten suitable for 18/20 watt retofit LED tube single side connection type). LED lamp : Make : Bajaj Cat No. BLRB 20W CW LED (retrofit LED tube lamp 20 Watt, Single end connection) or equivalent in Wipro/Philips/ Havells as approved by GE complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting including taking down old unserviceable complete all as specified & directed. . Note : Make of batten and LED tube lamp should be of same make.
S&F in repair single phase direct connection type KWH meter , temper proof, plastic body with LCD display, 230/240V, 10-60 Amp, accuracy class I, 50 Hz, Conf to IS 13779, IP 54, with (parameters to show Date, time, current reading, KW, PF) including taking out old u/s complete all as specified and directed by EIC Make : Secure (Model Saral) or eqivelent of make: L&T Note : Old u/s meter to be deposite in AGE E/M store.
Taking down old ceiling fan/Exhaust fans/of any capacity after disconnecting the electric supply from any site, checking for its electrical defect and opening fans for checking of mechanical defect after dismantling of fan, carry out repair/over hauling including removing dust and grease, and cleaning of internal mechanical parts of fan with lubricant as per OEMs specification, checking of alignment of shaft, oiling and greasing, checking of worn out bearing and other defective parts, winding, condenser etc and re-assembling, and connecting/refixing of fans in its original position , replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, by providing new GI nut bolt, lock washer and lock/split pin complete all as specified and directed by Engr-in-charge. complete all as specified and directed. NOTE: (i) Rewinding and replacement of defective parts, Painting etc shall be measured and paid seperately.
M&L for Rewinding of Exhaust fan of 450/380 mm any make any model , 1400 rpm including taking down ,dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs specifictions, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spare parts for replacement will be deemed to be included in Quoated rates.
M&L for Rewinding of Exhaust fan of 300 mm any make any model , 1400 rpm including ,dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs specifictions, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spare parts for replacement will be deemed to be included in Quoated rates. (ii) Repairs shall be carried out through authorised technicians or as approved by GE.
M&L for Rewinding of ceiling fan of sweep 1200/1400 mm any make any model including taking down ,dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs specifictions, replacement of defective parts, re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spare parts for replacement will be deemed to be included in Quoated rates. (ii) Repairs shall be carried out through authorised technicians or as approved by GE.
Supply only ball bearing 6201 & 6202 suitable for 1200mm sweep celing fan complete all as specified and as directed.
Supply only Rubber Bush as per OEM specification suitable for ceiling fan complete all as specified and as directed.
Supply and fixing Condensor 2.15 Mfd for 1200 mm Sweep celing fan complete all as specified and as directed.
Supply only Canopy 1200 mm Sweep celing fan complete all as specified and as directed.
Supply and fixing Condensor Stand 1200 mm Sweep celing fan complete all as specified and as directed.
Material & labour for painting of ceiling fans any sweep complete in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dusts etc including writing of MES No complete all as specified.
M&L for Rewinding of Pedestal fan 450 mm sweep any make any model including, dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs specifictions, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spare parts for replacement will be deemed to be included in Quoated rates. (ii) Repairs shall be carried out through authorised technicians or as approved by GE.
M&L for Rewinding of wall fan 300/450 mm sweep any make any model including ,dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs specifictions, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spare parts for replacement will be deemed to be included in Quoated rates. (ii) Repairs shall be carried out through authorised technicians or as approved by GE.
M&L for Rewinding of desert cooler any make any model including ,dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs specifictions, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spare parts for replacement will be deemed to be included in Quoated rates. (ii) Repairs shall be carried out through authorised technicians or as approved by GE.
MS R.K.ENTERPRISE
Neha Enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .