| Sl No | Description | Qty | Unit | Raj Engineering Co. L2 | INSTANT TRADE CORPORATION L6 | paramount systems L1 | Bansal Traders L5 | Tushar Engineers L4 | Gupta Brothers L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.01 | Lifting & Lowering of sub pump set along with all allied accessories from T/wells i.e dismantling of column pipe by opening/cutting of nut and bolts as required, opening and rejointing of cables. Testing commissioning of T/wells after lowering as per site requirement. The work including all arrangement of man and tools tackles such as tripod, chain, pulley pipe wrench etc. | 2 | Job | 19,000 ₹22,420 | 20,000 ₹23,600 | 6,000 ₹7,080 Lowest | 8,000 ₹9,440 | 24,000 ₹28,320 | 32,000 ₹37,760 |
| 1.02 | Supply-Of G.I. Pipe 50mm dia, Medium-class, each of 3 Meters Long, duly threaded on both-ends, welded & fitted with G.I./M.S. Flange of minimum thickness 6 mm on both ends with a Slot for Submersible-Cable. Welding of M.S Strips at both ends on flange Make of Pipe: Jindal / TATA | 18 | Nos. | 35,280 ₹41,630.4 Lowest | 50,400 ₹59,472 | 36,000 ₹42,480 | 46,800 ₹55,224 | 36,000 ₹42,480 | 36,000 ₹42,480 |
| 1.03 | Supply of three core flat cable with bare bunched copper conductor insulated & sheathed with PVC for submersible pump motor with voltage grade upto 1100V of 6.0 sq mm. size in 100mtr. Roll. Make: Make: grandley / Havells/as approved by djb | 1 | Roll | 14,500 ₹17,110 | 1,800 ₹2,124 Lowest | 13,000 ₹15,340 | 18,000 ₹21,240 | 20,000 ₹23,600 | 20,000 ₹23,600 |
| 1.04 | Supply-Of Tail-piece of Medium-Class G.I.-Pipe 0.6 mtr mm Long with one-end threaded, as per out-let of Pump and another-end flanged, as per size of G.I. Pipe 50 mm dia. Make of Pipe: Jindal / TATA. | 2 | Nos. | 1,520 ₹1,793.6 Lowest | 4,000 ₹4,720 | 2,000 ₹2,360 | 2,700 ₹3,186 | 3,000 ₹3,540 | 2,000 ₹2,360 |
| 1.05 | Supply-Of Orifice-Assembly 50mm dia, 0.6 Meter Long, Double-Flange. | 2 | Nos. | 1,960 ₹2,312.8 Lowest | 5,600 ₹6,608 | 3,000 ₹3,540 | 3,000 ₹3,540 | 4,000 ₹4,720 | 2,400 ₹2,832 |
| 1.06 | Supply of Hut Type Feeder Piller Automatic LT Panel board 2 suitable for 415 Volts, 3 phase, 50 Hz, 4 wire system for operation of up to15 HP submersible set, made out of not less than 2mm thick CRCA for load bearing members, and 1.6 mm for doors of panel, totally enclosed, dust and vermin proof, floor mounted type.The panel size 760mmX1360X300mm and having (1)FP MCB 63A,10KA :-1 No (2) AMMETER (DIGITAL) 0-50A AE/L&T/REP. :-1No (3) ASS 6A-1No (4) VOLTMETER (DIGITAL) 0-500:- 1 No (5) VSS 6A:-1 No (6) CT 50/5A :-3 No CONTACTOR FOR PHASE REVERSAL 40A 2 No (7) PHASE SEQUENCE RELAY S1 VMR7 : 1 No (8) TP CONTACTOR 32A :-2 No (9) TP CONTACTOR 18A 1 No (10) ADD ON BLOCK 1NO+1NC:-5 No (11) ELECTRONIC STAR DELTA TIMER 230V :- 1 No (12) THERMAL OVERLOAD RELAY 14-23A:-1 No (13) MOTOR PROTECTION RELAY :-1 No (14) INDICATION LAMP (R/Y/B) 22.5MM: 3 No (15) CONTROL MCB 6A :-3 No (16) PUSH BUTTON (START/STOP) 22.5MM: 2 No (17) AUTO MANUAL SELECTOR SWITCH 6A:-1 No (18) QT TIMER ANALOG 24HRS:-1No (19) TP MCB 10A,10KA :-1 No Make of accessories L&T/C&S/AE/Minilac/Selec/ as per DJB approved | 2 | Nos. | 89,000 ₹1,05,020 | 96,000 ₹1,13,280 | 90,000 ₹1,06,200 | 96,000 ₹1,13,280 | 86,000 ₹1,01,480 | 72,000 ₹84,960 Lowest |
Tender Value
Refer Docs
EMD Value
₹5,500
Closing Date
29 Aug 2025, 11:15 amClosed
EE ENM M VI
DELHI JAL BOARD MU BLOCK PITAMPURA DELHI-34
Replacement of ENM equipments for various tube wells at 356 Praghati Apartment and 1040 Shivaji Enclave in AC 26 re invite
2025_DJB_277104_15
NIT No. 14 (2025-26)M-VI
Open Tender
Miscellaneous Works
Item Rate
30 days
EE ENM M VI
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Account No SB 50448339804
₹5,500
Yes
6 Sept 2025
22 Aug 2025
29 Aug 2025
22 Aug 2025
29 Aug 2025
22 Aug 2025
Lifting & Lowering of sub pump set along with all allied accessories from T/wells i.e dismantling of column pipe by opening/cutting of nut and bolts as required, opening and rejointing of cables. Testing commissioning of T/wells after lowering as per site requirement. The work including all arrangement of man and tools tackles such as tripod, chain, pulley pipe wrench etc.
Supply-Of G.I. Pipe 50mm dia, Medium-class, each of 3 Meters Long, duly threaded on both-ends, welded & fitted with G.I./M.S. Flange of minimum thickness 6 mm on both ends with a Slot for Submersible-Cable. Welding of M.S Strips at both ends on flange Make of Pipe: Jindal / TATA
Supply of three core flat cable with bare bunched copper conductor insulated & sheathed with PVC for submersible pump motor with voltage grade upto 1100V of 6.0 sq mm. size in 100mtr. Roll. Make: Make: grandley / Havells/as approved by djb
Supply-Of Tail-piece of Medium-Class G.I.-Pipe 0.6 mtr mm Long with one-end threaded, as per out-let of Pump and another-end flanged, as per size of G.I. Pipe 50 mm dia. Make of Pipe: Jindal / TATA.
Supply-Of Orifice-Assembly 50mm dia, 0.6 Meter Long, Double-Flange.
Raj Engineering Co. (BID ID -1615151)
Gupta Brothers (BID ID -1615760)
Tushar Engineers (BID ID -1615856)
Bansal Traders (BID ID -1615956)
INSTANT TRADE CORPORATION (BID ID -1615850)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .