| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | H1₹56.3 LAdmitted-Finance VILL MANKAR NORTH RAIPUR PO MANKAR DISTT PURBA BARDHAMAN PIN 713144 WB | MANKAR | PURBA BARDHAMAN | WB | 713144 | H1 | Admitted-Finance | |
| 2 | H2₹53.9 L−₹2.4 L (4.27%)Admitted-Finance VILL MIRIKPARA GALSI WEST PO GALSI PS GALSI DIST PURBA BARDHAMAN PIN 713406 WB | GALSI | PURBA BARDHAMAN | WEST BENGAL | 713406 | H2 | Admitted-Finance | |
| 3 | H3₹51.4 L−₹4.9 L (8.65%)Admitted-Finance VILL PO CHOMON NEAR AIR FORCE STATION ADAMPUR JALANDHAR PB | JALANDHAR | JALANDHAR | PUNJAB | H3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | GALSI DEVELOPERS PVT LTD H2 | M/S JAI ENGINEERS H3 | M/S ABHINABA ENTERPRISE H1 |
|---|---|---|---|---|---|---|
| 1.00 | Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soil
Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding. | 149 | Cum | 185 ₹27,565 | 180 ₹26,820 Lowest | 200 ₹29,800 |
| 2.00 | Returning, filling in, including spreading, leveling, watering & well ramming in layers n. exc 25 cm thick complete all as specified and directed. | 129 | Cum | 77 ₹9,933 | 70 ₹9,030 Lowest | 100 ₹12,900 |
| 3.00 | Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. | 13 | Cum | 90 ₹1,170 Lowest | 95 ₹1,235 | 100 ₹1,300 |
| 4.00 | Taking up/down old unserviceable CI/DI pipes from trenches/wall/floor etc for repair including cleaning with all fittings of 80mm bore complete all as specified and as directed by Engr-in-Charge. Note: Excavation/earth work will be measured and paidseparately under relevent item. | 12 | RM | 45 ₹540 | 40 ₹480 Lowest | 55 ₹660 |
| 5.00 | All as per item No 4.00 here-in-before but of size 100 mm bore complete all as specified and directed. | 98 | RM | 78 ₹7,644 | 70 ₹6,860 Lowest | 90 ₹8,820 |
| 6.00 | All as per item No 4.00 here-in-before but of size 150 mm bore complete all as specified and directed. | 140 | RM | 88 ₹12,320 | 80 ₹11,200 Lowest | 90 ₹12,600 |
| 7.00 | M&L for refixing/relaying of existing old DI/CI tubing of size 80mm bore obtain from item No 4.00 here in before, in new or existing position, after cleaning external and internal, and providing with and including all new jointing materials like rubber gasket including lubricants suitable as required laid in trenches incl connecting with existing lines all as directed by Engr-in-charge.
Note:(i) DI fittings if required will be measured and paid separately. | 6 | RM | 32 ₹192 | 30 ₹180 Lowest | 35 ₹210 |
| 8.00 | All as per item No 7.00 here-in-before but of size 100 mm bore, obtain from item No. 5.00 here in before. | 50 | RM | 55 ₹2,750 | 50 ₹2,500 Lowest | 60 ₹3,000 |
| 9.00 | All as per item No 7.00 here-in-before but of size 150 mm bore, obtain from item No. 6.00 here in before. | 62 | RM | 65 ₹4,030 | 60 ₹3,720 Lowest | 80 ₹4,960 |
| 10.00 | Supply, Laying, jointing & testing of Ductile iron (DI), pressure pipes with spigot and socket ends, centrifugally cast, class K-7, with cement mortar lining in inner side as per IS:8329 and other relevant standards and metalic zinc coating followed by a finishing layer of epoxy paint in outer side, suitable for push on joint(rubber gasket joint) in any length with inside cement mortar lining, 80 mm bore laid in trenches | 6 | RM | 1,680 ₹10,080 | 1,650 ₹9,900 Lowest | 1,700 ₹10,200 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
6 Jun 2026, 6:00 pmClosed
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DISTT- BURDWAN, STATE-WEST BENGAL PIN-713420
All as per BOQ
2026_MES_764379_1
8500-638/E8
Open Tender
Civil Works
Works
180 days
PANAGARH
As per tender documents
6 documents required · 6 mandatory
₹500
GE Panagarh
₹1 L
26 Jun 2026
9 May 2026
8 Jun 2026
9 May 2026
6 Jun 2026
23 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soil
Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding. | 149 | Cum | - | - |
| 2 | Returning, filling in, including spreading, leveling, watering & well ramming in layers n. exc 25 cm thick complete all as specified and directed. | 129 | Cum | - | - |
| 3 | Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. | 13 | Cum | - | - |
| 4 | Taking up/down old unserviceable CI/DI pipes from trenches/wall/floor etc for repair including cleaning with all fittings of 80mm bore complete all as specified and as directed by Engr-in-Charge. Note: Excavation/earth work will be measured and paidseparately under relevent item. | 12 | RM | - | - |
| 5 | All as per item No 4.00 here-in-before but of size 100 mm bore complete all as specified and directed. | 98 | RM | - | - |
| 6 | All as per item No 4.00 here-in-before but of size 150 mm bore complete all as specified and directed. | 140 | RM | - | - |
| 7 | M&L for refixing/relaying of existing old DI/CI tubing of size 80mm bore obtain from item No 4.00 here in before, in new or existing position, after cleaning external and internal, and providing with and including all new jointing materials like rubber gasket including lubricants suitable as required laid in trenches incl connecting with existing lines all as directed by Engr-in-charge.
Note:(i) DI fittings if required will be measured and paid separately. | 6 | RM | - | - |
| 8 | All as per item No 7.00 here-in-before but of size 100 mm bore, obtain from item No. 5.00 here in before. | 50 | RM | - | - |
| 9 | All as per item No 7.00 here-in-before but of size 150 mm bore, obtain from item No. 6.00 here in before. | 62 | RM | - | - |
| 10 | Supply, Laying, jointing & testing of Ductile iron (DI), pressure pipes with spigot and socket ends, centrifugally cast, class K-7, with cement mortar lining in inner side as per IS:8329 and other relevant standards and metalic zinc coating followed by a finishing layer of epoxy paint in outer side, suitable for push on joint(rubber gasket joint) in any length with inside cement mortar lining, 80 mm bore laid in trenches | 6 | RM | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
PS638.pdf
Tender Documents • 1.16 MB
BOQ_856142.xls
BOQ • 0.64 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .