EXECUTIVE ENGINEER
EXECUTIVE ENGINEER ELECTRICAL DIVISION PWD B AND R AMRITSAR
Replacement of 1 Nos Lift Sr No LD1451 26 Person Ground Plus 8 Floor in Bebe Nanaki Block attached to Shri Guru Nanak Dev Hospital Amritsar
2026_CEPW_176198_1
19/2026-27
Open Tender
Electrical Works
Percentage
Amritsar
Please refer Tender documents.
9 documents required · 9 mandatory
₹5,000
₹99,900
25 Sept 2026
25 Sept 2026
5 Oct 2026
25 Sept 2026
5 Oct 2026
25 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply Installation & Testing of 01 Nos./26 Person 1768 Kgs/ (with machine room)/ 1mps speed/ Travel 28 Mtr. (approx)/G+8/9 Stops/9 Openings/Shaft Size required:2400 mmw x 3000mmd/Car Size: AS PER IS STD /Clear Opening: 1200mmw x 2000mmh/Pit-1700mm/Headroom 4800mm / Side Opening doors/V3F Microprocessor based Selective Collective Simplex Control / Car-SS Honeycomb/ Side Opening Power Operated Car Door in SS Honeycomb/Side Opening Power Operated Landing Door in SS Honeycomb/PVC Flooring Protection/Automatic Rescue Device / Infra-Red Screen Sensor / Auto light & Fan off/Over Load Warning Indicator with announcement / SS Handrail on three sides of Wall /SS False Ceiling in Car/Dot Matrix Led D & P Indicators In Car & Landings-Orange Colour/Push Button-Orange LED Illumination/2way intercom - Press & Speak / Std Car operating panel /Full Load Bye pass/ Floor Annunciator with Music/ Sill Angle / Sill Support/Fireman's Switch / Battery Operated Alarm Bell and Emergency Light/Minor Builders Works/Scaffolding/Pit Ladder/ Free Service One Year/All std Govt. Features. as below :- 1.Battery operated emergency light with rechargeable battery 2. Battery operated emergency alarm with rechargeable battery 3. Adjustable Guide shoes 4. Micro movement LED based buttons. 5. Door Open and Close buttons 6. Emergency Intercom provided inside the elevator 7. Emergency Intercom usable without the voice communication 8. Load weighing device with overload bypass feature and Overload function with Audio Visual Indication 9. Steel iterns, door frames sill angle's fascia plates, spring buffers 10. Automatic phase reversal device and Phase Fallure protection 11. Call registration 12. Audio & Video System installted in the lift indicating arrival at a floor 13. Manual break lever 14. Additional car gate lock | |||||
| 1.01 | 15. Automatic break testing infrared safety curten 16. Bralle Buttons (Inside and outside) with Braille instructions for the communication system 17. Kick plate/Skirting 18. Lift anoucement system to announce floor level's in english language only and indication of door for entrance/exit is either Open or Close 19. Car Operating Panel 20 Car plateform constructed out of cold rolled grain oreinted formed sheets of steel 21. Phase two device fire man drive 22. Fire Man switch at main lobby 23. Car false ceiling in stainless steel 24. Pit ladder 25. Anti Nuisance call protection 26. Door Nudging 27. Automated Resuce Device to bring the elevator to the nearest landing in case of power failure. 28 The use of visualty and acoustically reflective wall surfaces should be minimized within cause discomfort and affect the visual acuity of people with impairments. 29 The floor of the lift car should be slip resistant have similar frictional qualitites to the floor of the lift landing to decrease the risk of stumbling.
Ift door is a positive aid to navigation for wheelchair users. 30 The provision of a mirror on the wall of the lift car opposite the lift door is a positive aid to navigation for wheelchair users. It allows the wheelchair user to see if anyone is behind them and also see the floor indicator panel. The micror should not extend to below 900 mm from the lift door to avoid confusing people with impaired sight 31 The emergency communication system should be coupled with an induction loop system installed all around the lift. Telephone units, where provided, should have an inbuilt inductive coupler to assist persons using hearing aids. lift to be provided, which allows easy manoeuvrability of wheelchair user. | 1 | each | 47,77,300 | ₹47,77,300 |
| 2 | Cost of Civil Work L/S | 9 | Per Floor | 24,000 | ₹2,16,000 |
| 3 | Buy Back Cost (-) | 1 | Per lift | 80,000 | ₹80,000 |
| 4 | Cost of Dismentaling | 1 | Per lift | 80,000 | ₹80,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
Tendernotice_2.pdf
PDF • 21.74 MB
BOQ_358755.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .