Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹40.0 L+₹1.0 L (2.65%)Rejected-Finance CHENNAI | L2 | Rejected-Finance being high bid value rejected | |
| 3 | L3₹40.2 L+₹1.2 L (3.05%)Rejected-Finance 17 A SUBASH CHANDRA BOSE STREET MELAKARUNKULAM POST PALAYAMKOTTAI TALUK TIRUNELVELI 627 356 | TIRUNELVELI | TIRUNELVELI | TAMIL NADU | 627356 | L3 | Rejected-Finance being high bid value rejected | |
| 4 | L4₹40.8 L+₹1.8 L (4.52%)Rejected-Finance VIVEKA HOME 207 D UDANGUDI ROAD TISAYANVILLAI 627657 TIRUNELVELI | TISAYANVILLAI | TIRUNELVELI | TAMIL NADU | 627657 | L4 | Rejected-Finance being high bid value rejected | |
| 5 | L5₹41.3 L+₹2.3 L (6.00%)Rejected-Finance 10 67 1 CHINNAMUSHIDIWADA PENDURTHI VISAKHAPATNAM ANDHRA PRADESH 530051 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530051 | L5 | Rejected-Finance being high bid value rejected |
Tender Value
Refer Docs
EMD Value
₹78,000
Closing Date
5 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Tirunelveli
GE TIRUNELVELI INS KATTABOMMAN NAVAL BASE POST VIJAYANARAYANAM TIRUNELVELI
GE/TVL/8216
2022_MES_531074_1
GE/TVL/8216
Open Tender
Miscellaneous Works
Item Rate
180 days
Vijayanarayanam
As per NIT/ Tender documents
8 documents required · 8 mandatory
₹500
GE Tirunelveli
₹78,000
Yes
21 Jul 2022
15 Jun 2022
7 Jul 2022
15 Jun 2022
5 Jul 2022
29 Jun 2022
15 Jun 2022 - 21 Jun 2022
60 days
Amount
SCHEDULE 'A' PART-I [ B/R WORKS]
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off the premises complete all as directed.
Material and Labour for Vitrified ceramic coloured tiles double charged/dark shade 10mm thick (square/rectangular) area of each tile exceeding not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed of 15mm thick in CM 1:6 complete all as specified and as directed.
Taking down chowkhat or frames (without taking off shutters from the frame) exc 1.5 Sqm & n exc 4 Sqm each complete all as specified and as directed.
Taking down chowkhat or frames (without taking off shutters from the frame) n exc 1.5 Sqm each complete all as specified and as directed.
Taking down shutter and refixing in the same opening, of any description exc 1 sqm but n exc 2 sqm each complete all as specified and as directed.
Material and labour for Brick work with subclass ‘B’ bricks straight or curved on plan exc 6m mean radius and built in CM 1:6 complete all as specified and as directed.
Taking down cement plaster on brick walls etc including raking out joints, inserting for key, scrubbing down with water etc., complete complete all as specified and as directed.
M&L for lead free X ray shielding red mud tiles as approved by council of scientific & industrial research and fixed with chemiclas as per manufacturer instructions under supervision of staff of CSIR -AMPRI and after fixing necessray testing and quality assurance through AERB approved agencies etc. complete all as directed by Engineer-in-charge. Note:- The quoted amount including necessary testing, CSIR staff supervising charge,& all transportation charges etc.
Material and Labour for Glazed ceramic coloured tiles in vertical surface 350 x 250x 7mm/ 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match fixed overand including backing coat of 10 mm thick in CM 1:4 all as specified and directed.
M&L for rendering 10mm thick on brick or concrete surfaces in CM 1:6 on fair faces of brick work or concrete surfaces of wall finished even and smooth (without using extra cement) complete all as specified and as directed.
S&F of X Ray shielded inspection glass of size 600 x 600mm x 8mm thick fixied in the wall opening including all accessories for fixing of glass complete all as specified and as directed.
S&F 46mm thick X Ray Room door covered with 1.6mm thick lead with frame of opening size 1.20mtr width x 2.10mtr height complete with all accesseries , insulation and locking arrangement etc (Size measured by outer side of frame) complete all as specified and as directed.
Supply and fix powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
M & L for 12mm thick Prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination, fixed with screws to timber frame work complete all as specified and as directed.
Supply & fix powder coated anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, anodised aluminum snap beading, roller screws etc. complete all as specifieds
S&F 75mm long Mortice latch with two levers (vertical type), mild steel body and fixed to aluminium door shutter complete all as specifieds.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specifieds.
S&F Bib Cock Auto Closing System with Built-in Control Cock, Wall Flange & Elbow Operated Extended Lever complete all as specifieds. (Make Jaquar CODE: PRS-CHR-043MED)
Material and Labour for vitrified ceramic tiles 10mm thick double charged /dark shade (Square / rectangular) polished, as in vertical surface, over and including provision of cement bedding 10 mm thick in CM 1 : 4 set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and as directed
M & L for 5.50mm thick tinted Sheet glass, ordinary quality and glazing with aluminium beading in square exc 0.5 sq. m in each panel complete all as specified and as directed
Material and labour for 18 mm thick prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and as directed.
Supply and fixing stainless steel Handle fancy type 100 mm size complete all as specified and directed.
Material and labour for PVC edge lipping 3/4mm thick fixed with nails for 18/19mm thick prelaminated particle board and shutters and etc complete all specified and as directed.
Supply and fixing stainless steel roller of size 25mm x 12mm, 450mm length with male and female bracket suitable for baskets complete all as specified and directed. Make : Evershinr, Olive or equivalent
Material and labour for second class hard wood plain fillets square in section clean swan secured with screws exceeding 13 sq cm and not exceeding 25 sq cm complete all specified and as directed.
S & F for drawer lock with 6 Brass lever locking mechanism and strong sheet metal body zinc plated fancy type complete all as specified and as directed. (Make : Godrej or equivalent)
S&F PVC keyboard drawer with set of bracket and steel rollers fixed with particle board complete all as specified and directed.
Supply and fixing Stainless steel Hinge of size 65mm self closing Italian pattern suitable for Cabinet and shelves opening /closing operation (fancy type) complete all as specified and directed.
Supply and fix Magnet of suitable size fixed for cabin leafs, drawers etc complete all specified and as directed. Make : Royal or equivalent make.
Demolition of cement concrete in any description and in any position not otherwise specifically provided unreinforced complete all as specified and directed.
Material and labour for PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in plinth protection 75mm thick complete all as specified and as directed.
Material and labour for Preparation of newly plastered wall surfaces, and applying two coats of acrylic distemper over a coat of alkali resistant priming coat ovear a coat of 2mm thick wall care putty complete all as specified and as directed.
Material and labour for preperation of old surfaces of ceiling and appying two coats of white wash complete all as specified and as directed.
Material and labour for preperation of old surfaces of wall and appying two coats of white wash complete all as specified and as directed.
Material and labour for complete removal of existing treatment on wall surfaces, preparation of surfaces and applying two coats of acrylic distemper over a coat of alkali resistant priming coat over a coat of 2mm thick wall care putty complete all as specified and as directed.
Material and labour for complete removal of existing treatment on wall surfaces, preparation of surfaces and applying two coats of weather proof acrylic emulsion paint over a coat of priming coat complete all as specified and as directed.
Material and labour for complete removal of existing treatment on ceiling surfaces, preparation of surfaces and applying two coats of weather proof acrylic emulsion paint over a coat of priming coat complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint on old wooden surfaces exc 10cm width or girth including preparation of surfaces complete all as specified and as directed.
Supply and fix in repair of alluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.4mm and fixed with aluminium wire staples, etc complete all as specified and as directed.
M & L for hacking our old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete
Supply & fix sheet glass 3 mm thick ordinary quality and glazing with oil putty or aluminium snap beading in square not exceeding 0.5 Sqm in each panel complete all as specified and as directed.
SCHEDULE 'A' PART-II [ E/M WORKS]
Taking down carefully copper/aluminium point wiring (light, fan, socket and power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc and seperate the serviceable items like fan regulator and light fittings for re-use under respective items and remove unserviceable material out of site and making good disturbed surfaces of walls, floors etc complete all as specified and as directed.
Material and labour for Point wiring complete with FRLS PVC insulated unsheathed cable 1100V grade conforming to IS-694, 1.5 Sqmm (nominal area) multistranded with copper conductor drawn through and including non metallic rigid PVC conduit 20mm dia (ISI marked) and accessories, concealed in wall including breaking of wall and making good wall / surface of ceiling with sunken type pressed steel / welded terminal boxes made out of 1.2mm mild steel sheet, 3mm thick laminated sheet cover for mounting of switches, socket outlets, regulators etc., including provision of FRLS PVC insulated unsheathed 1.5 Sqmm FRLS multistranded with copper conductor as earth continuity conductor and connecting to common earth dolly complete all as specified and as directed for One light/fan point/Bell point etc.
All as per Item No. 45, but One 3 pin 5 Amps switch socket combination on the same board with other switches, with cables 1.5 Sqmm size all specified and as directed.
Material and labour for Point wiring complete with FRLS PVC insulated unsheathed cable 1100V grade conforming to IS-694, 1.5 Sqmm (nominal area) multistranded with copper conductor drawn through existing concealed PVC/Steel conduit and accessories, and making good surface of wall / ceiling for where ever required, with 3 mm hylam sheet cover including provision of FRLS PVC insulated unsheathed 1.5 Sqmm FRLS multistranded with copper conductor as earth continuity conductor and connecting to common earth dolly complete all as specified and as directed for the following :-.
a) One light/fan point/ bell point controlled by one one-way switch SP 5 Amps
(b) One 3 pin 5 Amps switch socket combination on the same board with other switches, with cables 1.5 Sqmm size all specified and as directed.
All as per Item No. 45 above, but using 2.5 sqmm FRLS single core multi stranded copper conductor cable concealed and make good distrubed surfaces and 1.5 Sqmm FRLS copper earth wire cable drawn through 20 mm dia PVC conduit including provision of conduit and conduit accessories for One 5 pin, 15 Amps Multi purpose switch socket combination on independent board complete all specified and as directed.
All as per Item No. 47 above, but using 2.5 sqmm FRLS single core multi stranded copper conductor cable drawn through existing conduit including 1.5 Sqmm FRLS copper earth wire cable for One 5 pin, 15 Amps Multi purpose switch socket combination on independent board complete all specified and as directed.
Supply and Fix in repair Switch Piano, flush type, Single Pole, 230 Volts, AC, one-way 5/6 Amps with ISI mark all specified and as directed.
Supply and fix in repair Switch socket combination, multipurpose 2/3 pin, 5Amps, flush type, universal, controlled by one switch 5Amps, ISI marked complete all as specified and as directed.
Supply and fix in repair Switch socket combination, multipurpose 2 in 1, 3 pin, 5/16Amps, flush type, universal, controlled by one switch 16Amps, ISI marked complete all as specified and as directed.
Supply and fix in repair Bell push, AC, 230 V flush type single pole, 5 Amps complete all specified and as directed.
Supply and Fix in repair DING DONG bell AC 240 V single pole 50 Hz and connecting up complete all specified and as directed.
Supply and fix in repair electronic type fan regulator rotary stepped type on the existing phenolic laminated sheet complete all specified and as directed.
Supply and Fix Ceiling rose 3 terminals, surface bakelite 65 x 50mm complete all specified and as directed. Make : Anchor / Bajaj / Leader / Cona with ISI mark.
Supply and fix in repair Sheet metal enclosures for DBs SP 8 way 240 V with neutral bus bar 200 Amps double door type with locking arrangement including removal of old unserviceable sheet metal enclosure complete all specified and as directed.
Supply and fix in repair Sheet metal enclosures for DBs TPN 4 way 415 V with neutral bus bar 200 Amps double door type with locking arrangement including removal of old unserviceable sheet metal enclosure complete all specified and as directed.
Supply and fix in repair Sheet metal enclosures for DBs VTPN 8 way suitable for MCCB Incomer 415 V with neutral bus bar double door type with locking arrangement including removal of old unserviceable sheet metal enclosure complete all specified and as directed.
M & L for single pole and neutral (SPN) sheet metal enclosure with a two pin and earth plug and socket complet with one single pole MCB 240 V, 20 amp complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCCB TP 415 volts 50 Hz , 100 amps, with rupturing capacity 16 KA with fixed overload and fixed short circuit rating complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB TPN, AC 415 Volts 40/63 Amps 10 KA, rupturing capacity, 'C' curve complete all as specified and as directed.
Supply and fix MCB SPN, AC 240 Volts 32 Amps 10 KA, rupturing capacity, 'C' curve complete all as specified and as directed.
Supply and fix MCB SP, AC 240 Volts 6 to 32 Amps 10 KA, rupturing capacity, 'C' curve complete all as specified and as directed.
Taking down carefully sub main wiring of any description including batten / PVC conduit pipe on surface and making good disturbed surfaces to match existing all as specified and as directed.
Material and labour for Sub main wiring with PVC insulated unsheathed 1100 volts FRLS grade single core multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and including 25mm dia PVC conduit heavy duty ISI marked(IS 9537 Part III) fixed in walls/roof concealed and all accessories along with 1 run of 4 sqmm PVC insulated unsheathed copper conductor single core multi stranded cable 1100V FRLS grade as earth continuity conductor and connected to common earth dolly complete all as specified and as directed. Note: 2 runs of 6 sqmm cable along with 1 run of 4 sqmm cable for earth conductor and one run of 25mm dia PVC conduit shall be measured as one length.
Material and labour for Sub main wiring with PVC insulated unsheathed 1100 volts FRLS grade single core multi stranded copper conductor cable 2 runs of 1.5 sqmm drawn through in and including 25mm dia PVC conduit heavy duty ISI marked(IS 9537 Part III) fixed in walls/roof concealed and all accessories along with 1 run of 1 sqmm PVC insulated unsheathed copper conductor single core multi stranded cable 1100V FRLS grade as earth continuity conductor and connected to common earth dolly complete all as specified and as directed. Note: 2 runs of 1.5 sqmm cable along with 1 run of 1 sqmm cable for earth conductor and one run of 25mm dia PVC conduit shall be measured as one length.
Material and labour for Sub main wiring with PVC insulated unsheathed 1100 volts FRLS grade single core multi stranded copper conductor cable 3 runs of 10 sqmm drawn through in and including 25mm dia PVC conduit heavy duty ISI marked(IS 9537 Part III) fixed in walls/roof concealed and all accessories along with 2 run of 6 sqmm PVC insulated unsheathed copper conductor single core multi stranded cable 1100V FRLS grade as earth continuity conductor and connected to common earth dolly complete all as specified and as directed. Note: 3 runs of 10 sqmm cable along with 2 run of 6 sqmm cable for earth conductor and one run of 25mm dia PVC conduit shall be measured as one length.
S & F wall mounted LED 20 watts, batten type fitting for surface and pendant application, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and intregrated electronic driver with connector block etc complete with all accessories internally pre wired and necessary mounting arrangements with PVC block and connection from ceiling rose to fitting complete including dismantling the existing unserviceable fitting, complete all as specified and as directed. Make : Philips / Jaguar.
Supply and fix in repairs LED mirror light fiiting surface mounted type 2 feet x 10W LED complete with all accessories internally pre wired and including connecting up with twin / three core flexible copper conductor cable with suitable size from ceiling rose to fitting etc, complete all as specified and as directed. Make : Philips / Jaguar.
Supply and fix in repairs LED Security light fiiting 15 W LED (1800 Lumen) complete with all accessories internally pre wired and including connecting up with twin / three core flexible copper conductor cable with suitable size from ceiling rose to fitting etc, including necessary suitable clamps & bracket GI Tubing medium grade 1mtr long bend into shape complete all as specified and as directed. Make : Philips / Jaguar.
S & F Recess mounting flat panel 36 Watt LED fitting 2x2 feet with flat panel to enhance the, white powder coated CRCA housing complete with full window acrylic diffuser & electronic driver, high brightness LEDs etc complete with all accessories intenally prewired and necessary mounting arrangements, complete incl removal of old unsv fitting all as directed by Engineer-in-charge. Make : Philips / Jaguar.
S & F Flood light light fitting LED type with 100 Watt LED made up of pressure die cast housing with IP 66 protection, with secondry optical including dismantaling old complete all as specified and directed by Engr-in-Charge. Make : Philips / Jaguar.
Taking down carefully Light fitting any type for reuse at same place including keeping in safe custody upto refixing, including refixing light fitting in same position complete connecting from ceiling rose to fitting with 2 core copper flexible cable/conductor all as per specified and directed by Engr-in-Charge.
Taking down ceiling fan, sealing cable end, dismantling blades and removing fan and blades to store and refixing after greasing and cleaning and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed.
Taking down calling bell indicator and supply and fix as calling bell indicator for 10 bell indicator complete all as specified and directed by Engr-in-Charge.
Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized earth Lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No.3 and connected to earth testing point all as specified and directed including testing on completion complete all as specified and as directed by Engr-in-Charge including taking down old complete Earthing system complete all as directed by Engineer-in-Charge. Note No.1: The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 20 mm dia watering pipe, wire mesh, 40mm dia light grade GI protection pipe for earth lead etc., complete
Supply ,install and testing high wall split Air conditioner of 2.0 TR capacity inverter type 5 Star rating with indoor and outdoor units (copper condenser coil, copper cooling coil and evaporator including required length of copper tubing and cables for connecting indoor and outdoor units ) complete with cordless remote control unit , with inverter rotary compressor with minimum 10 yrs warranty ,complete all as specified and as directed. Make : VOLTAS / BLUESTAR /CARRIER/ O GENERAL/HITACHI. Note : Rate quoted is inclusive of the following:- (i) Drain pipe UPVC with insulation from indoor unit (at any floor) to ground floor level and is to be fixed with necessary clamps complete. (ii) Drilling hole on the brick wall to facilitate routing of Copper pipe, drain pipe and cable from indoor unit to outdoor unit. (iii) Sealing the hole from outside ,after installation, with white cement. (iv) Pressure testing , cooling performance check and product demonstation. (v) 4 core cable of any required length for connecting indoor and outdoor unit. (vi) Material and labour for fixing Remote stand in wall. (vii) Copper pipe, 1/2" dia and 1/4 " dia as required. (viii) GI powder coated brackets , for fixing of split AC's
Supply and fix Voltage stabilizer for 2.0 TR AC, single Phase. 170-270 Volts, with initial time delay system complete all as specified and directed.
VVM CONSTRUCTIONS
M/S VIGNESH POWER SYSTEM
Vinayaga constructions
SIVA MARUTHI ENTERPRISES
M/s Shana Constructions
CHANDRASEKRAN ENTERPRISES
JR ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .