Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹64.5 LAccepted-AOC 86 NAROTTAM KUNJ MADHU NAGAR AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | 1 | Accepted-AOC Being lowest | |
| 2 | 2₹68.7 L+₹2.8 L (4.24%)Rejected-Finance 91 DEFENCE ESTATE PHASE II NEAR AMBEDKAR PARK DEORI ROAD AGRA UP | AGRA | UTTAR PRADESH | 282001 | 2 | Rejected-Finance Not being lowest | |
| 3 | 3₹84.6 L+₹18.7 L (28.5%)Rejected-Finance 59 100 AJIT NAGAR GATE KHERIA AGRA 282008 | AGRA | AGRA | UTTAR PRADESH | 282008 | 3 | Rejected-Finance Not being lowest | |
| 4 | 4₹84.7 L+₹18.8 L (28.5%)Rejected-Finance | 4 | Rejected-Finance Not being lowest | |
| 5 | 5₹87.6 L+₹21.7 L (33.0%)Rejected-Finance | 5 | Rejected-Finance Not being lowest |
Tender Value
₹91 L
EMD Value
₹1.6 L
Closing Date
20 Oct 2023, 6:00 pmClosed
HQ CWE Agra
112, Taj Road, Agra Cantt
SPL REPAIR TO TOILET BLOCK OF BLDG NO. P-133, 134 AND 136 BHARATPUR LINES OF 5 PARA (SF) UNDER GE (EAST) AGRA
2023_MES_619012_1
84295/E8
Open Tender
Civil Works
Item Rate
180 days
Agra
MES contractors enlisted in Class C category a(i) for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work
8 documents required · 8 mandatory
₹1,000
GE EAST AGRA
₹1.6 L
Yes
21 Dec 2023
15 Sept 2023
27 Oct 2023
15 Sept 2023
20 Oct 2023
29 Sept 2023
15 Sept 2023 - 22 Sept 2023
Amount
Taking up or down 20 mm bore steel tubing and connections, including cleaning for Refixing or removal to store complete all as specified and directed.
Supplying and laying 25 mm outer diameter of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
S & F for 25 mm outer diameter of CPVC brass elbow fixing to CPVC pipes at any location complete all as specified and directed.
S & F for 25 mm outer diameter of CPVC brass tee fixing to CPVC pipes at any location complete all as specified and directed
Taking up or down 25 or 32 mm bore steel tubing and connections, including cleaning for Refixing or removal to store complete all as specified and directed.
S&F for 25 mm bore GI Pipe/ tubes, medium grade, high pressure ISI Marked standerd specification, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Taking up or down 40 mm bore steel tubing and connections, including cleaning for Refixing or removal to store complete all as specified and directed.
Refixing 40 mm old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning for re-use measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
S&F for 110 mm bore PVC (SWR) Soil waste, rain water pipe and vent pipes single socketed in any length with rubber ring joints fixed to walls etc. as per site requirement and making good disturbe portion to match the existing surface complete all as specified and directed.
S&F for 110 mm bore PVC (SWR) bends any radius complete all as specified and directed
S & F for 110 mm bore PVC (SWR) bends with access door of any radius complete all as specified & directed.
S&F for 110 mm bore PVC (SWR) single T with access door of any radius complete all as specified & directed.
S&F for 110 mm bore PVC (SWR) single Y with access door of any radius complete all as specified & directed.
S & F 110 mm bore PVC (SWR) cowl of any radius complete all as specified & directed.
S&F in repairs 100 mm bore cast iron soil, waste or vent sand cast pipes in any length with or without ears, with cement joints fixed to walls including making good disturbe portion to match the existing surface complete all as specified and directed.
S&F in repairs 100 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access doors and cement joint including making good disturbe portion to match the existing surface complete all as specified and directed.
S&F in repairs 100 mm bore cast iron branch pieces/T, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access doors and cement joint including making good disturbe portion to match the existing surface complete all as specified and directed.
S&F Stack clamps out of 50 x 5 mm size flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
S&F in repairs 100 mm bore cast iron cowel and jointed with cement complete all as specified and directed.
S&F in renewal 5000 litres capacity Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position including 40 mm dia PVC float valve complete all as specified in SSR Part I including dismantling of storage tank complete all as specified and directed.
S & F in repair Gun metal gate valve with lever type handle suitable for 25 mm dia of pipe complete all as specified and directed.
S&F in renewal 500 litres capacity Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position including 25 mm dia PVC float valve complete all as specified in SSR Part I complete all as specified and directed.
S&F in repair 40 mm dia PVC float Valves high pressure, with polythene float and fly nut complete, screwed for Iron pipe or brass ferrule complete all as specified and direted.
S&F in repairs, 5 to 6 mm thick bevelled edge looking mirror of required size & shape of best quality with 50 X 20 mm size teak wood polished beading with 6 mm thick ply/AC/PVC board beading fixed with C.P screw etc complete all as specified and directed.
S&F in repairs Vitreous China counter type wash hand basin including CP waste cupling and 32 mm PVC flexible waste pipe 800mm long etc complete all as specified and directed .
S&F in repairs Pillar taps long body cast copper alloy fancy type with capstan heads chromium plated scrwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for 15 mm dia iron pipe complete all as specified and directed.
S&F in repairs 10 litres capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and PVC connections 15mm size with PTMT nuts of length 450mm, connecting up new and making good disturbe portion by using cement mortar complete all as specified and directed.
S&F in repair Vitreous China urinals full stall type complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing of nozzle for discharge of water flush pipe, grating and Union for discharge pipe complete all as specified and directed.
S & F in repairs PVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed.
S&F in repairs 15mm bore CP stop cock/angle cock, cast copper alloy fancy type, screwed down high pressure, screwed for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repair stop cock, (Concealed type) cast copper alloy, fancy type, chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket or PPR pipe etc making good disturbed portion complete all as specified and directed.
Supply & fixing in repair CP tubular towel rail, 60 cm long, 20mm bore, chromium plated complete all as specified & directed.
S & F in repairs Brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.
S&F in repairs flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete all as specified and directed.
S & F in repair CI floor trap, plain with grating including jointing with solvent cement (Diameter of outlet 75mm), jointing to waste pipe and fixed in cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) mixed with pedilite water proofing liquid @ 200ml in 50 kg cement and making good disturbe portion complete all as specified and directed.
Supply & fixing in repairs C.P. grating 100/125 mm dia as required at site complete all as specified & directed.
S&F in repairs vitreous China squatting pan (Orissa pattern), white, of size 580x440mm white, with CI 'P' or 'S' trap, integral foot rests including flush pipe, trap, lime concrete bedding and making good disturbe portion complete all as specified and directed.
S&F in repair vitreous china wash down water closed pan (Pedestal pattern) with 'P' or 'S' trap including connection to trap and cistern and flush pipe (excl flusingh cistern ) and making good to disturbed surface of floor complete all as specified and directed.
S & F in renewal of plastic WC seat cover and mild steel chromium plated or aluminised hinging device etc complete all as specified and directed.
S & F in repairs Flushing jet(health faucet) for pedestal pattern WC incl. flexible pipe and Brass Chcomium Plated nuts and bolts and water pipe of size 1150 mm long & fixed complete all as specified and directed.
S&F in repair bib taps, cast copper alloy, fancy type, chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket or PPR pipe etc making good disturbed portion complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (squre/ rectangular) area of each tiles exc 0.11 sqm but n. exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed with white cement and coloured pigment to match the tiles over & including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 450x300x7mm thick fixed over and including 10mm thick plaster in CM 1:4 on vertical surfaces such as skirting, dados and risers to steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over & including 20 mm thick cement screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed
M&L for 20-25 mm thick Kota stone slab in riser of steps, skirting, dado and pillar laid over and incl 10 mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for Grinding and polishing wax polishing to old existing kota stone complete all specified and directed.
Demolition of brick work built in cement mortar including all quoins arches pillar etc complete all as specified and directed.
M&L for brick work with sub class B old size bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for Brick work with sub-class `B' brick straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified & directed
Removing or Dismantling damage / cracked / concrete / loose concrete/plaster of ceiling / wall / chajja to expose the sound and hard concrete using a suitable mechanical device or by hammer and chisel, etc. The chipping shall be carried out to such depths that the rods are fully exposed to the best possible , complete all specified and directed.
M & L for applying cement based water proofing coating with high negative hydrostatic, good adhesion to substrate and enhanced durability on concrete or masonry walls. The waterproofing coating should have adhesion to substrate of 1.3 Mpa after 28 days, elasticity modulus of 14000-16000 N/mm2 after 28 days and average water/ powder demand of 0.24 to 0.26 for fluid consistency, complete all as specified and directed.
M&L for applying two component amine cured epoxy mastic coating using Light brush blasting using nonmetallic abrasive leaving a clean, rough and even pattern. It should be based on a 100% epoxy formulation and contains no solvents or water diluents. Apply two coats with brush or squeeze to the existing surface, working well into the substrate. It should achieve Compressive Strength of >70 MPa after 14days, having pot life Pot life, minutes at 270C, 100 g >40 mass, complete all specified and directed.
M&L for providing in areas with spalling (greater than 25% of ceiling concrete depht) leak proof shuttering to facilitate pouring of micro concrete to have a desired thickness as per design. The shuttering shall be provided till the top at the sides with a from the bottom of the slab to facilitate pouring of micro concrete. Further pouring corrosion resistant, non-shrink, rheoplastic, high-strength cementitious micro-concrete having fresh wet density of 2200-2400 kg/m. The micro-concrete in flowable consistency shall achieve a compressive strength not less than 20 N/mm2 at 24 hours, 30 N/mm2 at 3 days, 40 N/mm2 at 7 days and 50 N/mm2 28 days at 300C. Most importantly, the cured micro concrete shall contain in no metallic aggregates, or chlorides and shall be shrinkage compensated in the plastic state. The unrestrained expansion shall be between 1-3%. The flexural strength shall not be less than 10 N/mm2 at 28 days. The mico-concrete shall have a coefficient of thermal expansion similar to that of the host conmembrane unrolled and bonded to substance with side and end laps 75 mm and 100 mm as per manufacturer's all as specified. (a) Applying one coat of hot blown grade bitumen.
M & L for cutting of the surface using low viscosity emulsion which incorporate a special alkali reactive emulsion breaking system. It should be non-penetrating continuous filmcomplies with the internationally recognized ASTM C309-90 standards including all tools and tackels complete all as specified and directed by Engineer-in-charge @ 250gms/Sqm. Product should have daylight Reflectance of 70% as per ASTM E-1347 complete all specified and directed.
M&L for external Plastering of brick/concrete Surface using Fiber reinforced polymer modified repair mortar. The product shall be a single component thixotropic fiber reinforced polymer modified repair mortar needing only addition of water at site which can be applied by trowel. It is reinforced with specially designed bean shaped, alkali resistant synthetic fibers for exceptional resistance to cracking. It is recommended for repair situations requiring application of mortar up to 15-20mm thickness in one layer. Cement and sand can be used for finishing the surface. The product shall achieve a compressive strength of 11 MPa in 1day & 30 MPa in 28days and a minimum flexural strength of 6 Mpa @ 7 days. It shall have tensile strength of minimum of 2 Mpa. It shall have minimum bond strength of 2 MPa, complete all specified and directed.
M&L for preparing newly plastered or un plastered surfaces of wall and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
M&L for form work to sides and soffits of lintels, beams, columns, shelves, chajjas including overhangs etc for fair finished flat surface, complete all as specified and directed.
M&L for MS TMT bars 10mm dia and over as in reinforcement cut to length, bent to shape required including cranking bending spirally for hooping for columns, hooking ends & binding with and including MS annealed wire not less than 0.9mm dia complete all as specified and directed.
M&L for providing and applying one part alkaline based material, with corrosion inhibitors and dispersing agents for exposed steel after cleaning to loose scale or oxidized chips from bars, having bulk density 1.25. The material to be applied to the rusted metal with brush for complete wetting of rusted metal surface and allowed to react for 16-24 hours. After 24 hours, a white layer will appear which will protect further corrosion of metal/steel for about 5-7 days. Before applying protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth, etc.,complete all as specified and directed.
Taking down chowkhat with shutter not exc 1.5 sqm each (without taking off shutter from the frame) complete all as specified and directed.
All as per item No.62 above but exc 1.5 sqm but nexc 4.0 sqm each complete all as specified and directed.
M&L for solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life)
S&F Factory made soild PVC profiled panel door shutter 30 mm thick with integral skin as frame & 3mm thick high pressure compact laminate on both side of approved colour as infill, with 'C type Gl or 40 x 20 x19 of MS pipe as stiffner & supplying & fixing in frame at site as per specifications & drawing. complete all as specified & directed.
S&F of factory made soild PVC door frame of size 50mmx47mm made out of 5mm thick single side prelam PVC sheet reinforced with mild steel square tube , supplying & fixing in opening as per specification and drawing complete all as specified & directed.
S & F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm thick plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
S&F 100 mm long medium weight, cold rolled steel Butt hinges complete all as specified and directed.
S&F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F 150 mm long aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F Floor door stopper 150 mm long of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
S & F Aluminium anodised powder coated window with sliding three (03) track sliding shutters and 5 mm thick sheet glass including deco grill DG 102 using aluminium section as per Jindal sec no 20617, box sec as per Jindal sec no 20028, top sec as per Jindal sec no 20831, side sec as per Jindal sec no 20831, plain sec as per Jindal sec no 20737, wheel sec as per Jindal sec no 20736, interlock sec as per Jindal sec no 20737, U channel, I angle, clips sec as per Jindal sec no 19306 and stain less steel wire cloth netting ( 0.63 mm nominal dia) and average width of aperture 1.40 mm ) including necessary joining clips, glasing clips, handles, locking arrangements etc complete all as specified and directed.
S & F Anodised aluminium ventilator frame/shutters powder coated, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed.
S & F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with stainless steel wire staples complete all as specified and directed
Supply only 4 mm thick figured glass,pin headed type glass for glazing for aluminium window complete all as specified and directed.
M&L for demolition of reinforced cement concrete of any description and in any position complete all as specified and directed.
M&L for 20mm thick granite stone slab (of any type) as in floor or skirting, over & including 20 mm thick screed bed in CM 1:4,machine cut,bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed.
S&F 5.0 cm thick sand stone slabs in sun shades, chajjas, shelves, roof slabs etc n.exc. 2m in length punched dressed on face and along exposed edges, self faced on other side and set and pointed in CM 1:4 complete all as specified and directed.
M&L for providing pre-cast cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in cover (for manholes and drains) including necessary form work, set in CM 1:6 complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately)
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and directed.
Taking down cement or cement lime plaster of any discription on brick or stone walls/ ceilings etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L One coat of epoxy resin (FAIR BOND EP) on old concrete surface @ 0.30 kg/Sqm including preparation of surface as per as per manufacturer's instruction and applying 25 mm thick (average thickness) of cement and sand (fine grit) in ratio 1:4 mixed with chloride free sprey concrete plasticiser (spray crete) on ceiling, beams, chajjas & facia as per manufacturer's instruction with guniting machine of pressure capacity not less than 5kg per Sqm and finished the surface even & smooth by 10 mm thick cement plaster in CM (1:4) complete all as specified &as directed .
S&F galvanised welded steel wire fabric as extra reionforcement to RCC members like ceilings, chajja’s, beams, columns parapet walls, waste slab etc including all cutting and waste (wt not exc 4.00 kg/Sqm) complete all as specified and directed.
M&L for applying three coats of white wash on ceiling including preparation of new plastered or un-plastered surfaces, complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:6 on any faces of brick or concrete surfaces of walls & finishing the surface even and fair without using extra cement complete all as specified and directed.
M&L for applying three coats of white wash on wall including preparation of new plastered or un-plastered surfaces of walls, complete all as specified and directed.
Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M in depth for foundation, manholes, etc n.exc 10 Sqm plan and getting out in soft/loose soil complete all as specified and directed.
Demolition and breaking up 150 mm bore of pipe drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar including concrete bedding and haunching complete all as specified and directed.
M&L for 150 mm dia SGSW drain pipes grade ‘A’ laid in trenches and jointed in cm 1:1 complete all as specified and directed.
M&L PCC 1:4:8 type D-2, (using 40mm graded stone aggregate) as in bed of drain pipe including packing under and haunching against the sides of pipes after they are laid and tested for the 150mm dia of pipe complete all as specified and directed
Dismantling/ demolition of polymeric water proofing membrane single layer with and including plaster, PCC, Padding etc on roofs complete including removal of material and debris away from the site etc complete all as specified and directed.
Demolition of cement concrete (unreinforced) in any description and in any position not otherwise specifically provided for complete all as specified and directed.
Material and labour for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in roof kerbs, paddings, mud stops slightly chamfered or rounded in edges including required grove cutting complete all as specified and directed.
Material and labour for applying 15 mm thick plaster in CM 1:4 on brick or concrete surfacs including water proofing compound @ 2% by weight of cement complete all as specified and directed.
M & L for Provn of polymeric water proofing roof treatment to assessable RCC roof described as under and all as specified :- (a) Preparing RCC roof surface and applying one coat of bitumen primer @ Rs. 0.30 Kg /Sqm (b) Applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm (c) Laying of water proofing teratment with 3mm thick APP modified polymeric water proofing membrane with non woven polyster mat of weight 160gms/sqm as centre core and without multiple layers of polyethylene, finished on top and bottom with 7 micron thick flammable polyethylene applied by thermo fusion using LPG torch on the bottom portion of the membrane unrolled and bonded to substance with side and end laps 75mm and 100mm as per manufacturer’s all as specified. (d) Applying one coat of hot blown grade bitumen 85/25 grade @ 1.20 kg/Sqm over the membrane (e)Finally provide PCC tiles 250 x250 x20mm thick machine made over 15 mm thick screed in CM 1:4 grouted and pointed in CM 1:3 mixed with and including WPC @2% by weight of cement all as specified & directed (For accessible roof surfaces)
Supply only integral water proofing compound liquid admixture for mortar complete all as specified and directed.
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L PCC 1:2:4 type B2 (using 40mm graded stone aggregate) as in foundation filling/base with and including form work complete all as specified and directed.
M&L 40mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in floor finished even and smooth w/o using extra cement complete all as specified and directed.
Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10 cm girth etc in brick wall complete all as specified and directed.
M & L cutting holes into or through brick wall built in cement mortar superfacial area not exc 150 Sq cm and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 (using 20 mm graded stone aggregate) as required complete all as specified and directed.
Disconnecting existing 5000 ltr tanks , setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including all fittings complete all as specified and directed.
M & L 12 mm average thickness of smart care ready mix plaster over brick or stone wall as well as concrete surfaces specially designed ready to use cement based plaster with high quality polymer additives and well graded sand filler (use as per manufacture instruction) etc complete all as specified and directed.
M & L for applying Asian paints smartcare repair polymer binder for concrete/mortar in repair like spalled concrete surfaces strongly with plaster or as a bond coat for a repair patch work complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete and all as specified & directed.
M&L for Point wiring complete for One light/Fan/Exhaust Fan/Bell point controlled by one switch with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core with and including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, MS modular sunken boxes duly painted with one coat of red oxide and one coat of black paint not less than 1.6mm thick complete, including 1.5 Sqmm PVC, FRLSH cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
All as per item No 107 here in before but for one 3 Pin 5 Amp switch Socket outlet point on an independent board
All as per item No 107 here in before but for one 3 Pin 5 Amp switch Socket outlet point on Same board with other switches
All as per item No 107 here in before but with cable size FRLSH cable 4 Sq mm for one 15 Amps and multistrand insulated copper earth continuity conductor of size FRLSH cable 4 sqmm complete all as specified and directed
Supply and fixing modular switch piano single pole, one way 6 Amps 1 module, complete complete all as specified and directed.
Supply and fixing modular switch piano flush type 16 Amps single pole one way, one module, complete all as specified and directed.
Supply and fixing modular socket outlet 2/3 pin 6 Amps combined 2 module complete all as specified and directed.
Supply and fixing modular socket multipurpose 3 pin 6/16 Amps combined 2 module, complete complete all as specified and directed. .
Supplying & fixing for ceiling rose PVC Polycarbonate isolated body 62.5 x 25 mm, three terminals, complete all as specified & directed. .
Supply and fixing in repair modular cover plate with metal frame (inner and outer) 1 module for mounting switch and sockets complete all as specified and as directed. .
Supply and fixing in repair modular cover plate with metal frame (inner and outer) 3 module for mounting switch and sockets complete all as specified and as directed. .
Supply and fixing in repair modular cover plate with metal frame (inner and outer) 8 module for mounting switch and sockets complete all as specified and as directed. .
Supply and fixing in repair modular cover plate with metal frame (inner and outer) 2x6 (12) module for mounting switch and sockets complete all as specified and as directed. .
Supply and fixing in repair blank spacer plate for single module. Complete all as specified and directed .
Supply and fixing in renewal LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <20W (4 feet 20 W) luminaire lumen >1000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification complete all as specified and directed.
Supply and fixing in renewal LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <10W (2 feet 10 W) luminaire lumen >1000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification complete all as specified and directed.
Supply and fixing in renewal LED building security light fitting 35 Watt 230 V AC out-door type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, fixed to pole or wall of building with and including suitable Bracket made out of 40 mm dia GI light grade pipe, 1.20 m long bent to shape by cutting & welding as required & directed and fixed with two Nos of FI clamps of size 35x6 mm to be tightened with suitable size of bolts, nut and washers and including painted with two coats of aluminium paint over a coat of red oxide primer, and including connecting the fitting to electric source with & including twin twisted copper flexible wire of size 0.75 sqmm three core with suitable size flexible PVC conduit including all accessories and fixing arrangements for fixing the light fitting complete all as specified and directed.
Dismantling and taking down serviceable LED tube light fittings of any wattage or size and re-fixing & connecting up including provision of cable from ceiling rose or connector to fan including renewal of down rod, hanging clamp, PVC canopy, nut, bolts and suitable size flexible PVC conduit complete all as specified and directed.
M&L for Submain wiring with two single core FRLSH 6 sqmm copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall surface / ceiling for sub main connection including FRLSH 6 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth including dismantling of old unsv sub-main wiring and connection to earth dolly complete all as specified and directed Note:- Two single core FRLSH 6 sqmm copper conductor, one run PVC conduit and one run of FRLSH 6 sqmm earth wire shall be considered & measured as one unit.
Supply & fixing in renewal of sheet metal enclosure Vertical TPN DB 4 Way double door As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 250 A Copper Busbar for each phase with 2 Neutral bar, 2 earthbar and Cable ties for Cable manage-ment, fully insulated busbar & shrouded Neutral bars, Improved Pan assembly for easy of installation, Prefitted masking sheet, Reversible Door for IP 54 DB's, With provision for 160 Amp MCCB as incomer and SP/TP MCB's as outgoing complete all as specified and directed.
Supply and fixing MCCB 4 pole, 160 Amps, 50 Hz, Icu=16 KA at 415 volts with thermal magnetic alongwith adjustable magnetic protection for current setting Icu=Ics = 100% with adjustable over load setting (minimum 70% to 100%) value from 10 to 15 times of related capacity as per IEC-60947-1 and 60947-2 standard complete all as specified and directed.
Supply and fixing in repair MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete with out MCB and with enclo-sure blank plates for unused way suitable for 4 way ISI marked complete all as specified and directed.
Supply and fixing in repair MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete with out MCB and with enclo-sure blank plates for unused way suitable for 12 way ISI marked, including taking down old unsv MCB DB and MCBs complete all as specified and directed.
Supply and fixing MCB SP 6 to 32 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing MCB SPN 40-63 Amp rating 240V, 10KA 'C' curve and current carrying ca-pacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Materials and labour as in renewal for earthing complete with galvanized earth plate electrode of size 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel wire 4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 15mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
Supply and fixing in renewal of Exhaust Fan high quality mettalic body, heavy duty (4 blades) resistant to colour change 300 mm sweep, 900 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 0.75 Sqmm copper cable and suitable size of flexible conduit pipe from celling rose to exhaust fan motor and writing MES No. in black synthetic enamel paint/engraving tools etc complete all as specified and directed.
Supply and fixing in renewal of electric water heater, storage type made of ultra thick super cold rolled steel plates, feroglass dry powder coating technology inner tank (copper) and heating element heavy duty magnesium anode rod with steel core to protect enamelled tank from rust and corrosion 2 KW capacity,230 V, 1 Phase AC, 50 Hz, 50 litre, BEE 5 Star, Energy saving high density PUF insulation, glass coated heating element offers superior heating performance and resistance to oxidation and carbonation at high temperatures rated complete with all accessories such as safety valve, thermostat,NRV, connection piece etc complete all as specified and directed.
Supply and laying in renewal XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm 4 Core in trench/floor/on pole/wall complete all as specified and directed.
Excavating in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm thick each layer complete all as specified and directed.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming complete all as specified and directed.
Supply and laying well burnt sub class ‘B’ bricks. ( designated 75) locally available best quality laid dry in trenches for protection of underground cable complete all as specified and directed.
M&L for drilling suitable dia horizontal bore holes for insertion/ laying of 40 mm to 90 mm bore HDPE pipe of any description below/under existing road surfaces / floors at a level not less than 0.60 metre etc with using mechanical / or manual devices as required at site including making good the disturbed surfaces to match with the existing surface after laying pipes complete all as specified and directed. Note : (i) Cost of equipment tools and plant material (horizontal boring rig machine) required for boring shall be arranged by contractor at no extra cost to the Govt.
Supply and lay HDPE pipe medium class, ISI Marked double wall corrugated as in cable protection pipe of outer dia 40mm including all fittings complete all as specified and directed.
Gupta Automobiles
deva engineers
Krishna Constructions
Asha Construction
M/S DEVENDRA KUMAR GUPTA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .