27 Feb 2024, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
REPAIR/ MAINTENANCE OF DG SETS, AMF PANELS, AND OTHER MISC E/M INSTALLATION AT AF STN NARAINA AND REPAIR/ REPLACEMENT UG PIPE LINES, PUM SETS AND OTHER ASSETS INSTALLED AT WATER SUPLLY INSTALLATION AT AF STN BASANT NAGAR IN AOR OF GE (AF) FARIDABAD
2024_MES_640390_1
GE (FBD)/AF-73/2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Delhi
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) FARIDABAD
₹80,000
Yes
9 Apr 2024
2 Feb 2024
29 Feb 2024
2 Feb 2024
27 Feb 2024
20 Feb 2024
2 Feb 2024 - 9 Feb 2024
Amount
Preventive Maintenance/repair M0/M1 or M2 to 250 KVA Gen set installed at sub station by replacement of lubricant oil filter fuel oil filter bye pass filter, “O’ ring, fuel filter water separator assembly, draining out un serviceable engine oil, cleaning of pump, checking & tightening of mounting nut & bolts, crank case, cleaning of valves, battery terminals, checking of radiator, PH value of coolant, topping with premixed coolant and inhibitor corrosion testing the engine on load and checking for any leakage of oil/fuel/coolant complete all as spceified and directed by Engineer-in-Charge. Note 1 :-(i) Parts required for replacement will be measured and paid separately under Schedule ‘A’ item (ii) The contractor will be responsible for attending any complaint/defect occurs to DG set at odd hours during operation. If the defects are not attended within 4-6 hrs recovery of Rs. 300/- per day will be effected (iii) The contractor has to submit the responsibility certificate of PMC carried out from date of servicing/repair. SPARE PARTS FOR DG SET Note 2: Contractor need to furnish responsibility certificate i.e contractor is liable for rectification of fault within 06 Months and repair will be done under liability period without any extra cost.
Supply only Element lub oil filter Cartrige
Supply only fuel filtter Cartage
Supply only Pre Filter Assembly
Supply only seal 'O' ring
Supply only KOEL Care genuine oil
Supply only K-COOL super plus Coolent
Supply only Air Filter for 250 KVA DG Set .
Supply only distilled water.
Supply only Battery terminals.
Preventive Maintenance/repair M0/M1 or M2 to 100/125 KVA Gen set " Greevs" installed at sub station in Basant Nagar Officer's Mess by replacement of lubricant oil filter fuel oil filter bye pass filter, “O’ ring, fuel filter water separator assembly, draining out un serviceable engine oil, cleaning of pump, checking & tightening of mounting nut & bolts, crank case, cleaning of valves, battery terminals, checking of radiator, PH value of coolant, topping with premixed coolant and inhibitor corrosion testing the engine on load and checking for any leakage of oil/fuel/coolant complete all as spceified and directed by Engineer-in-Charge. Note 1:- (i) Parts required for replacement will be measured and paid separately under Schedule ‘A’ item (ii) The contractor will be responsible for attending any complaint/defect occurs to DG set at odd hours during operation. If the defects are not attended within 4-6 hrs recovery of Rs. 300/- per day will be effected (iii) The contractor has to submit the responsibility certificate of all changed/repaired parts for six months from the date of servicing/repair. Note 2: Contractor need to furnish responsibility certificate i.e contractor is liable for rectification of fault within 06 Months and repair will be done under liability period without any extra cost.
Preventive Maintenance/repair M0/M1 or M2 to 50/ 75 / 80 KVA Gen set " Greevs" installed at sub station in Basant Nagar Officer's Mess by replacement of lubricant oil filter fuel oil filter bye pass filter, “O’ ring, fuel filter water separator assembly, draining out un serviceable engine oil, cleaning of pump, checking & tightening of mounting nut & bolts, crank case, cleaning of valves, battery terminals, checking of radiator, PH value of coolant, topping with premixed coolant and inhibitor corrosion testing the engine on load and checking for any leakage of oil/fuel/coolant complete all as spceified and directed by Engineer-in-Charge. Note :- (i) Parts required for replacement will be measured and paid separately under Schedule ‘A’ item (ii) The contractor will be responsible for attending any complaint/defect occurs to DG set at odd hours during operation. If the defects are not attended within 4-6 hrs recovery of Rs. 300/- per day will be effected (iii) The contractor has to submit the responsibility certificate of all changed/repaired parts for six months from the date of servicing/repair. SPARE PARTS FOR DG SET Note 2: Contractor need to furnish responsibility certificate i.e contractor is liable for rectification of fault within 06 Months and repair will be done under liability period without any extra cost.
Supply only Element lub oil filter Cartrige
Supply only fuel filtter Cartage complete
Supply only Pre Filter Assembly
Supply only seal 'O' ring Make- Kirloskar
Supply only genuine Engine oil
Supply only Coolent
Supply only Air Filter for 75 KVA DG Set
Supply only distilled water.
M&L for repair of PCB suitable for 50 to 250 KVA DG set AMF panel complete all as spceified and directed by Engineer-in-Charge.
M&L for repair of AVR Unit of 50 to 250 KVA DG Set complete all as spceified and directed by Engineer-in-Charge.
M&L for Repair of Self starter of 50 to 250 KVA DG Set complete all as spceified and directed by Engineer-in-Charge.
M&L for replacement of fuel pipe of DG set connecting from inlet of the tank to dg set complete all as spceified and directed by Engineer-in-Charge.
S&F in repair of Digital maltifunctional power meter for AMF panel complete all as spceified and directed by Engineer-in-Charge.
Supply and replacement of V belt for radiator fan suitable for 320 KVA DG set as per sample complete all as spceified and directed by Engineer-in-Charge.
M&L for repair/replacement of battery 12 volts, 180 amh complete all as spceified and directed by Engineer-in-Charge.
M&L for complete oherhauling of Engine incl opening of engine head of 250 KVA DG Set carefully and Servicing of internal parts of engine, piston, lining etc and entire assembly and fixing the parts after opening complete all as spceified and directed by Engineer-in-Charge. Note :- Spare part are paid separately.
M&L for replacement of the following unserviceable parts of 50 to 250 KVA DG set as per the existing Kirloskar model of the DG set complete all as spceified and directed by Engineer-in-Charge.:-
Piston
Ring set
Piston pin
CR Bearing
Head valve
Head Gas kit
Head seal
Packing kit of the engine
S&F in replacement of water pump suitable for 50 to 250 KVA DG Set complete all as spceified and directed by Engineer-in-Charge.
M&L for replacement of engine lining after complete opening of engine of 250/ 320 KVA DG Set including topup of engine oil all as specified and directed by engr-in-charge
M&L for Repair of fuel nozzeles of 50 to 250 KVA DG Set complete all as spceified and directed by Engineer-in-Charge.
M&L for repair of turbocharger of 50 to 250 KVA DG SET complete all as spceified and directed by Engineer-in-Charge.
Supply and fix in replacement of Battery charger 24 V DC with digital display complete all as spceified and directed by Engineer-in-Charge.
M&L for Design, development, supply commissioning and testing EHCC certified ground tubular effective chemical earthing system (CPRI tested for 15 KA current capacity for LT Iine) highly anticorrosive long life electrode with and including adequate protective coating to withstand servere weather conditions in the earth pit of the standard size comprising of 40mm x 3m Long Copper rod as primary conductor and hollow copper tube of 80mm x 3m long as secondary conductor to install with suitable connecting terminal confirming of IS 3043 : 1987 specification, highly conductive packing material to be filled in earth pits for providing uniform, low resistivity anticorrosive, hygroscopic medium around the earth system for improving the efficiency of current dissipation with crystalline conductive mixture (CCM) 20 Kg per bag (3 bag per kit) minimum or sufficient quanitities required as per site complete including RCC earthing pit cover , material and labour complete all as spceified and directed by Engineer-in-Charge. Note :- Excavation / drilling hole in hard soil/rock is included in the rate quoted.
Supply and fix in repair Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as spceified and directed by Engineer-in-Charge.
Supply and fix in repair Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as spceified and directed by Engineer-in-Charge.
Supply and fixing contactor 100 Amp 3 pole for time switch astro type/Nature switch fitted inside box complete with all electrical connection after dismantling old one complete all as spceified and directed by Engineer-in-Charge.
Supply and fixing contactor 63 Amp 3 pole for time switch astro type/Nature switch fitted inside box complete with all electrical connection after dismantling old one complete all as spceified and directed by Engineer-in-Charge.
Suply and fix in replacement of Sheet metal enclosure for MCCB 3P, one No complete all as spceified and directed by Engineer-in-Charge.
S&F in repair wall mounted TPN busbar chamber factory made with busbar of current rating 400 Amp, 415, 4 way complete all as spceified and directed by Engineer-in-Charge.
Supply and fixed in repair,MCCB 400 Amp ,3 pole, adjustable type ,36 KA including under voltage/over voltage relay complete all as spceified and directed by Engineer-in-Charge.
Supply and fix in replacement of Onload Changover switch 200 Amp, 4 pole ,415 V,50 Hz in sheet metal enclosure complete all as spceified and directed by Engineer-in-Charge.
Supply and fix in replacement of Onload Changover switch 400 Amp, 4 pole ,415 V,50 Hz in sheet metal enclosure complete all as spceified and directed by Engineer-in-Charge.
M& L for preparation of trench i.e excavation in trench for cable having trench size 300mm x 450mm x 100mm in loose/soft soil and getting out including brick work in CM 1:4 , PCC work 1:2:4 type B-0 12.5 mm using crushed stone aggregate, plastering in 1:4 incl WPC @ 3% wt of cement and finishing of surface complete all as spceified and directed by Engineer-in-Charge. Note : Maximum length of trench shall be considered as 10 mtr.
Supply and fixed in repair,MCCB 250 Amp ,3 pole, adjustable type ,25KA including under voltage/over voltage relay complete all as spceified and directed by Engineer-in-Charge.
Supply and fixed in repair,MCCB 125 Amp ,3 pole, adjustable type ,25KA including under voltage/over voltage relay complete all as spceified and directed by Engineer-in-Charge.
M & L cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate for pole pedestal (PCC) including necessary form work etc complete all as spceified and directed by Engineer-in-Charge.
M&L for painting of outer canopy of DG set 100 to 250 KVA complete all as spceified and directed by Engineer-in-Charge.
M&L in replacement complete radiator assembley suitable for 100 - 125 KVA complete with all the connections complete all as spceified and directed by Engineer-in-Charge.
M& L for welding each canopy door to the outer unit for proper closing and opening including hinges and repainting complete all as spceified and directed by Engineer-in-Charge.
M&L for painting MES No. , Engine No. ,Alternator No. , Manufacturer Name clearly in a rectangle yellow box having dimension 3 ft x 2 ft with blue or black paint complete all as spceified and directed by Engineer-in-Charge.
S&F in replacement post top lantern LED 40 W or next highest wattage having IP65 protction for single phase connection 50 Hz 230 Volts complete all as spceified and directed by Engineer-in-Charge.
S&F LED flood light luminarie 70 W with high pressure die cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection complete all as spceified and directed by Engineer-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 16 to 35 sqmm,Outdoor type complete all as spceified and directed by Engineer-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 70 to 95 sqmm,Outdoor type complete all as spceified and directed by Engineer-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 150 to 185 sqmm,Outdoor type complete all as spceified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as spceified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as spceified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as spceified and directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 m wide and and not exceeding 1.5 m depth in loose/soft soil and getting out complete all as spceified and directed by Engineer-in-Charge.
Returning, filling in, with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, complete all as spceified and directed by Engineer-in-Charge.
Removal of surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as spceified and directed by Engineer-in-Charge.
M & L for brick protection with sub class 'B' bricks laid dry flat over electric cable in trenches complete all as spceified and directed by Engineer-in-Charge.
M & Labour for sand cushioning with a layer of sand 80mm thick consolidated before laying of cable and 150mm thick consolidated after laying of cable in trenches ducts for electric cable protection including consolidation complete all as spceified and directed by Engineer-in-Charge.
M&L for rectification of fault in AMF panel of DG set and testing on load ranging from 50 to 250 KVA complete all as spceified and directed by Engineer-in-Charge.
M&L for replacement of relay of AMF panel complete all as spceified and directed by Engineer-in-Charge.
M&L for replacement of display panel of AMF suitable for DG set rating 50 to 250 KVA along with all connections and push buttons for mode change and start stop button complete all as spceified and directed by Engineer-in-Charge.
S & F rubber insulation mat of size 1.8 mtr x0.9mtr wide 2mm thick green / blue colour ISI marked embozzed for up to 3.3 KV complete all as spceified and directed by Engineer-in-Charge.
M & L for Repair and Maintenance of split type AC's of capacity 1.5/2 TR comprising of the following tasks installed at different locations including testing complete all as specified and directed by Engineer-in-Charge.(a) Inspecting and checking the Indoor/outdoor units for noise free operation (b) Checking the electrical connection for tightness (c) Cleaning the condenser with cleaning agent followed with pressurized water and cleaning the cooling coil with air blower.(d) Greasing/Oiling of condenser fan motor and blower motor. (e)Checking for any refrigerant leakage. (f) Checking for serviceability of remote control unit.
Supply and fixing in replacement of starting capacitor 80-100/100-120 mfd for split type A/C's of capacity 2 TR complete all as specified and directed by Engineer-in-Charge.
M & L for Disconnecting and taking down burnt compressor of capacity 2TR from split type AC unit and Supply and Fix new reciprocating type compressor with charging of refrigerent (R410A,R32,R134A)after dehydration testing and vaccumming one as per existing model complete including testing complete all as spceified and directed by Engineer-in-Charge.
M & L for Disconnecting and taking down burnt compressor of capacity 2TR from split type AC unit and Supply and Fix new rotary type compressor with charging of refrigerent after dehydration testing and vaccumming one as per existing model complete including testing complete all as spceified and directed by Engineer-in-Charge.
M & L for Disconnecting and taking down burnt compressor of capacity 1.5 TR with CFC free Refrigerent (R410a,R32) from split type AC unit and Supply and Fix new rotary/reciprocating type compressor with charging of refrigerent after dehydration testing and vaccumming one as per existing model complete including testing complete all as spceified and directed by Engineer-in-Charge.
M&L for repair to gas leakage of split type AC unit of capacity 1.5/2TR capacity including pressure testing, dehydration and gas charging complete all as spceified and directed by Engineer-in-Charge.
Taking out unserviceable PCB from 1.5 /2 TR split type A/C unit and refixing the serviceable PCB after repair from workshop complete testing complete all as spceified and directed by Engineer-in-Charge.
Taking out unserviceable PCB from 1.5 /2 TR inverter split type A/C unit and refixing the serviceable PCB after repair from workshop complete testing complete all as spceified and directed by Engineer-in-Charge.
M&L for replacement of unserviceable inverter type PCB from the existing inverter split type A/C unit 1.5/2.0 Ton complete of existing make ,testing complete all as spceified and directed by Engineer-in-Charge.
Supply and charging Refrigerant(R410,R32,R134 and existing refrigerent) to any type of AC unit including CFC free and non CFC Free AC complete all as spceified and directed by Engineer-in-Charge.
M&L in replacement of copper tubing 10mm outer dia suitable for AC 2TR capacity complete all as spceified and directed by Engineer-in-Charge.
M&L in replacement copper tubing 15mm outer dia complete all as spceified and directed by Engineer-in-Charge.
M & L for Dismantling of Split type AC 1.5/2.0 TR capacity from position after including disconnecting all connections between indoor and out door units,shifting,backup refrigerant for reuse and install at a place where directed carefully,including cutting on wall,making hole and make good disturbed surface properly matching surface,inspecting,servicing and refilling refrigerant and testing complete all as spceified and directed by Engineer-in-Charge.
M & L for Taking out unserviceable outdoor unit and supply and fix the new outdoor unit of 1.5/2 TR capacity split AC 230 Volts single phase including installing ,charging complete all as spceified and directed by Engineer-in-Charge.
M & L for Taking out unserviceable indoor unit and supply and fix the new indoor unit of 1.5/2 TR capacity split AC 230 Volts single phase including installing ,charging complete all as spceified and directed by Engineer-in-Charge.
M&L for Disconnecting and taking down burnt compressor of capacity 1.5TR from split type AC unit and Supply and Fix new inverter type compressor with charging of refrigerent (R410A,R32,R134A)after dehydration testing and vaccumming one as per existing model complete including testing complete all as spceified and directed by Engineer-in-Charge.
M&L for Disconnecting and taking down burnt compressor of capacity 2TR from split type AC unit and Supply and Fix new inverter type compressor with charging of refrigerent (R410A,R32,R134A)after dehydration testing and vaccumming one as per existing model complete including testing complete all as spceified and directed by Engineer-in-Charge.
Supply and fix in replacement copper condensor coil for split AC 2 TR complete all as spceified and directed by Engineer-in-Charge.
Supply and fix in replacement copper condensor coil for split AC 1.5 TR complete all as spceified and directed by Engineer-in-Charge.
Supply and fix in replacement copper evaporater coil for split AC 2 TR complete all as spceified and directed by Engineer-in-Charge.
Supply and fix in replacement copper evaporater coil for split AC 1.5 TR complete all as spceified and directed by Engineer-in-Charge.
Supply and fix in replacement MCCB 400 Amps ,4 Pole ,36 KA ,50 Hz ,415 Volt including under voltage/over voltage relay,adjustable overload setting and short circuit setting complete all as spceified and directed by Engineer-in-Charge.
Supply and fix in replacement MCCB 250 Amps ,4 Pole ,25 KA ,50 Hz ,415 Volt including under voltage/over voltage relay, adjustable overload setting and short circuit setting complete all as spceified and directed by Engineer-in-Charge.
Supply and fix in repair Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as spceified and directed by Engineer-in-Charge.
Supply and fix in repair Test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as spceified and directed by Engineer-in-Charge.
Supply and fix in repair BLDC fan Energy Efficicent ceiling fan Sweep size 1200mm with speed 350 RPM motor air delivery 220 CMM input power 28W-32W and having remote control complete all as spceified and directed by Engineer-in-Charge. Note:- OLD fan need to deposit in store no credit will be provided for the same.
Supply and fix in replacement of starter panel for 2x7.5 HP motor ,3 phase ,415 V in sheet enclosure including phase corretor DOL starter push buttons contactors and MCBs complete all as spceified and directed by Engineer-in-Charge.
Supply and fix in replacement of starter panel for 10 to 12.5 HP motor ,3 phase ,415 V in sheet enclosure including phase corretor DOL starter push buttons contactors and MCBs complete all as spceified and directed by Engineer-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 300 to 400 sqmm,Outdoor type complete all as spceified and directed by Engineer-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 630 sqmm,Outdoor type complete all as spceified and directed by Engineer-in-Charge.
Supply and fix in repair on load changeover switch 400 amp 4 pole ,415 V,50 Hz in sheet steel enclosure for surface mounting with padlocking facility with the connecting accessories complete all as spceified and directed by Engineer-in-Charge.
Supply and fix in repair on load changeover switch 630 amp 4 pole ,415 V,50 Hz in sheet steel enclosure for surface mounting with padlocking facility with the connecting accessories complete all as spceified and directed by Engineer-in-Charge.
S&F in repair LED flood light 120 watt ISI marked,enviromental friendly high efficient,pressure die cast with aluminium extruded Heat sink IP66 toughened glass complete all as spceified and directed by Engineer-in-Charge.
M&L for repair of Submersible pump of capacity 10 HP ,3 phase shifting to workshop Complete opening for rewinding with super enamled copper wire of existing size & repair/replacement of worn out parts such as shaft,Ball bearing, bush, impellers, coupling ,mechanical seal,jet assembly etc including re-assembling and refixing in position complete all as spceified and directed by Engineer-in-Charge.
M&L for repair of centrifugal pump of capacity 5 HP to 7.5 HP ,3 phase shifting to workshop Complete opening for rewinding with super enamled copper wire of existing size & repair/replacement of worn out parts such as shaft,Ball bearing, bush, impellers, coupling ,mechanical seal,jet assembly etc including re-assembling and refixing in position complete all as spceified and directed by Engineer-in-Charge.
Taking up or down following sizes steel tubing and connections, including cleaning for refixing or removal to store complete all as spceified and directed by Engineer-in-Charge.
All as per item No 113 above but 50 mm bore
All as per item No 113 above but 25 mm bore
All as per item No 113 above but 20 mm bore
All as per item No 113 above but 15 mm bore
Supply, laying and fixing GI water tubing medium grade with all fittings and fixed complete to all walls,ceiling,laid in floors,roof etc with following sizes complete all as spceified and directed by Engineer-in-Charge.
All as per item No 118 above but 50 mm bore
All as per item No 118 above but 25 mm bore
All as per item No 118 above but 20 mm bore
All as per item No 118 above but 15 mm bore
M&L for preparation of external surface LT Panel/Feeder piller Size of 1250 x 1250 x 450 and 950 x 950x 450 mm (approx) rubbing the rusted surface and painting with two coats of spray paint with synthetic enamel paint over a coat of metal primer matching with existing colour complete all as spceified and directed by Engineer-in-Charge.
M&L earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc complete all as spceified and directed by Engineer-in-Charge.
M & L in replacement earthing with steel earth plate electrode of size 60 x 60 cm x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less tha 1.5 mtr deep below normal grund level connected to galvanized iron strip size 32 x 6 mm as earthing lead by means of nuts, bolts and washers of steel after wlding of GIstrip to earth electrode to the full length of earht plate, 40mm dia GI tubing lightgrade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover ofsize 30x30 cm made of RCC 1:3: with suitable handle, angle iron frame made of angle iron of size 40x40x4m, adequate qty of charcoal dust and salt layers all around the earth plate and filling of vegetables soil to the remaining 10% removal of surplus soil and retruning filling in all as required at site including test point made outof steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and complete all as spceified and directed by Engineer-in-Charge.
M&L for repair of centrifugal pump of capacity 1 HP to 2 HP ,3 phase shifting to workshop Complete opening for rewinding with super enamled copper wire of existing size & repair/replacement of worn out parts such as shaft,Ball bearing, bush, impellers, coupling ,mechanical seal,jet assembly etc including re-assembling and refixing in position complete all as spceified and directed by Engineer-in-Charge.
S&F in repair LED post top lantern 70 watt with die cast aluminum pipe spigot ,aluminium PDC heat sink ,opal diffuser IP65 complete all as spceified and directed by Engineer-in-Charge.
M&L for Demolition of existing valve pit chamber and M&L for masonry valve pit of size 900x900x900mm internal size complete with excavation, earth work and brick work in CM 1:6, 15mm thick plastering in CM 1:4 internally including 5mm thick MS Sheet cover and angle iron frame of suitable size and two coats of synthetic enamel paint over one coat of red oxide primer complete with locking arrangement complete all as spceified and directed by Engineer-in-Charge. Note : The dimension of Valve pit chamber shall be as per old existing chamber.
S&F Gun Metal globe or Gate valve iron wheel head screwed both ends for iron pipes of size 50mm dia bore complete all as spceified and directed by Engineer-in-Charge.
S&F cable duct cover made of iron of size 320mm x 800 mm of thickness 3.0 mm complete all as spceified and directed by Engineer-in-Charge.
M&L for Providing,PCC 1:3:6 type C-1 using 20 mm graded stone aggreat,for damaged earth pit chamber with fair finish internal surface of concrete chamber of earth complete all as spceified and directed by Engineer-in-Charge.
S & F rubber insulation mat of size 1.8 mtr x0.9mtr wide 19mm thick red colour ISI marked embozzed for up to 15 KV complete all as spceified and directed by Engineer-in-Charge.
M& L for Drilling and tapping cast iron water mains for branch connection of the internal dia 15 mm including clamp piece and nuts and bolts and directed.
Supply and install centrifugal in repair type chemical dosing pump of 6 to 12 LPH , single phase , 230 volts suitable for installation in pump house on discharge line of centrifugal pump to dose suitable amount of chlorinated liquid mixture complete all as spceified and directed by Engineer-in-Charge.
M&L for painting of water supply pipe lines of any size & length upto 20 RM of both pump houses with two coat of synthetic enamal paint of any tint and highlighting the incoming and outgoing water pipes from pumphouse by making the directional aerrows & writing alphabets 'I' & 'O' (not less than 5 cm height) with any light colour paint complete all as spceified and directed by Engineer-in-Charge.
Taking down desert cooler of any size by disconnecting electrical supply, cleaning, oiling of all moving part of pump & exhaust fan/kit, Replacing PVC pipes, nozzles, distributors, pads, checking electrical connections complete all as spceified and directed by Engineer-in-Charge.
Supply and fixing in replacement of wood pads(set of three)as per sample complete all as spceified and directed by Engineer-in-Charge.
Supply and fixing in replacement the new desert cooler pump including testing for proper functioning complete all as spceified and directed by Engineer-in-Charge.
Supply and fixing in replacement new body of desert cooler as per sample duly painted of 20 SWG sheet with 22 SWG flops, front grill, PVC pipe, nozzle, distributor and nut bolts washers for fixing fan clamps, complete all as spceified and directed by Engineer-in-Charge.
S&F new exhaust fan kit of desert cooler with super enameled copper wire complete all as spceified and directed by Engineer-in-Charge.
Taking down and rewinding of fan motor 400mm of desert cooler with super enameled copper winding wire including replacement of bush complete all as spceified and directed by Engineer-in-Charge.
Supply and fixing front grill PVC of desert cooler as per sample complete all as spceified and directed by Engineer-in-Charge.
Supply and fixing in replacement plug top 15 Amps complete all as spceified and directed by Engineer-in-Charge.
Supply and install 400 mm fan bade suitable for desert cooler complete all as spceified and directed by Engineer-in-Charge.
Supply and fixing in replacement ventilating fan plastic 250 mm sweep body 240 v 50 Hz single phase complete all as spceified and directed by Engineer-in-Charge.
Supply and fixing in replacement ventilating fan plastic 300 mm sweep body 240 v 50 Hz single phase complete all as spceified and directed by Engineer-in-Charge.
Supply and fixing in replacement wall mounted fan plastic body 240 v single phase 50 Hz complete all as spceified and directed by Engineer-in-Charge.
Supply and fix in replacement Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as spceified and directed by Engineer-in-Charge.
M&L for Chemical analysis of water sample collected from MES borewell and outside supply to check the TDS and impurities level in the sample complete all as spceified and directed by Engineer-in-Charge.
Supply and fix in replacement of flame proof exhaust fan 300 mm sweep iron body with all accessories complete all as spceified and directed by Engineer-in-Charge.
S&F in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade,cross-sectional area 6 sqmm 2 core complete all as spceified and directed by Engineer-in-Charge.
M&L for providing Display board of size 1m x 1m x1 cm madeup with acrylic sheet material consisting of "water disribution system and MES Logo" in Capital Letter at the Top complete with fixing arrangements to the wall complete all as spceified and directed by Engineer-in-Charge.
S&F in replacement of PVC copper cable for submersible pump of size 6 Sqmm 3 core flat complete all as spceified and directed by Engineer-in-Charge.
M&L for rectification of leakage of UG water pipe lines of size 80 to 150 mm Bore of any description such as CI/DI/GI pipe line at any location including necessary excavation, earth work, dewatering, cutting existing pipe lines including repairs with suitable flanges, Joints or any other material complete all as spceified and directed by Engineer-in-Charge.
All as per item No 154 above but for size of 15 mm to 50mm dia pipe line complete all as spceified and directed by Engineer-in-Charge.
M&L for rectification of leakage complaints of sluice valves by opening removing gland plate and pumping/taking water from water pit and proving gland packing and refitting by replacing worn out bolts,nuts and washers complete all as spceified and directed by Engineer-in-Charge. Note: bolts,nuts and washers will be paid under relevant items of schedule
S&F in repair wall mounted TPN busbar chamber factory made with busbar of current rating 400 Amp, 415, 4 way complete all as spceified and directed by Engineer-in-Charge.
Supply and fixing in repair/replacement of solar street light fittings with integrated 12 Watt LED street light system with solar PV Panel 100 WP, integrated LED fitting with Li-Ion Battery 11.1 V 17 Ah , MPPT based solar charge controller,Motion Sensor and tubular pole of height 5 Mtrs complete all as spceified and directed by Engineer-in-Charge.
M& L for constrution of fire point having size approx 3.5 mtr x 2 mtr in respective latest IS including buckets hooks etc and painted in red complete all as spceified and directed by Engineer-in-Charge.
S&F in replacement of PVC copper cable for submersible pump of size 6 Sqmm 3 core flat complete all as spceified and directed by Engineer-in-Charge.
M&L for repair of sluice Valve chamber including pcc work ,plastering ,paniting and replacement of existing iron sheet complete all as spceified and directed by Engineer-in-Charge. Note : The dimension of Valve pit chamber shall be as per old existing chamber.
M&L for Dewatering the existing U/G sump of 25000 Ltrs capacity and cleaning the internal surface of sump for removing scales, funges, mud and other foreign material ,scrubbing with water using wire brush and watering the surfaces with mixture of bleaching powder and water ,finally washing with fresh water and treating with one coat of lime wash to internal wall and bottom surfaces etc complete for one time,writing in enamel paint note in block capital letter as cleaned on (date) and due date etc,height not less than 5 cm complete all as spceified and directed by Engineer-in-Charge.
NAVYUG VYAPARI
ETERNITY PROJECT
M/S Anand Enterprises
M P TYAGI ENGINEERS AND CONTRACTORS
M/S Parshant Associates
Ridhi engineers and builders
S K ENGINEERS AND CONTRACTOR
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .