Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.2 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹43.7 L+₹50,930 (1.18%)Rejected-Finance | L2 | Rejected-Finance NOT ADMITTED BEING L2 | |
| 3 | L3₹45.7 L+₹2.5 L (5.77%)Rejected-Finance FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L3 | Rejected-Finance NOT ADMITTED BEING L3 | |
| 4 | L4₹48.1 L+₹4.9 L (11.3%)Rejected-Finance PLOT NO D 2 COAL DEPOT FOSBERY ROAD SEWRI E MUMBAI 400 015 | MUMBAI | MUMBAI | MAHARASHTRA | 400015 | L4 | Rejected-Finance NOT ADMITTED BEING L4 | |
| 5 | L5₹50.6 L+₹7.3 L (17.0%)Rejected-Finance E 84 OF HQ CWE NW MUMBAI AGE 87 1 3 GEETA NAGAR NAVY NAGAR COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L5 | Rejected-Finance NOT ADMITTED BEING L5 |
| Sl No | Description | Qty | Unit | D.N.PATIL L2 | venus enterprises L7 | M.K Enterprises L3 | shree arihant constrution L5 | PASAYDAN ELECTRICALS L1 | K A ELECTRIC CO L4 | Om Sai Enterprises L6 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Notes : - (i) The is at Serial No 82 of TPP 2025-26 (ii) Please refer schedule 'A' notes before quoting the tender. (iii) Amount of Schedule of Credit shall be deducted off line by the department. | ||||||||||
| 1.01 | M&L for earthing with GI earth plate electrode of size 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32 x 6 mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4) type B1 using (20 mm graded stone aggregate), mild steel angle iron frame made out of MS angle iron of size 40x40x6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade pipe for watering, 40 mm dia light grade GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-1(2009) connected to earthing test point including testing on completion and taking down old u/s materials complete all as specified and directed. NOTE: (i) The earth chamber shall be constructed 0.50m away from the edge of earth pit and the cost of the same is deemed to be included in quoted unit rate.
(ii) GI Strip and protection pipe upto 7.5m is deemed to be included in the quoted unit rate.
(iii) GI watering pipe upto 1.2m s deemed to be included in the quoted unit rate. | 18 | Each Set | 6,000 ₹1,08,000 Lowest | 13,000 ₹2,34,000 | 7,200 ₹1,29,600 | 12,500 ₹2,25,000 | 6,500 ₹1,17,000 | 7,200 ₹1,29,600 | 8,000 ₹1,44,000 |
| 1.02 | S&F in repairs Danger notice plate, 20cm x 15cm size, of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of suitable size complete all as specified and as directed. | 82 | Each | 150 ₹12,300 | 160 ₹13,120 | 120 ₹9,840 Lowest | 150 ₹12,300 | 650 ₹53,300 | 136 ₹11,152 | 130 ₹10,660 |
| 1.03S&F in repairs MCCB of following current carrying capacity complete all as specified and as directed:- | ||||||||||
| 1.04 | 4 Pole, MCCB, 500 Amps, Adjustable type,415V, with breaking capacity 36KA rating | 4 | Each | 17,000 ₹68,000 Lowest | 22,000 ₹88,000 | 18,600 ₹74,400 | 21,500 ₹86,000 | 40,000 ₹1,60,000 | 19,200 ₹76,800 | 20,000 ₹80,000 |
| 1.05 | 4 Pole, MCCB, 400 Amps, Adjustable type,415V, with breaking capacity 36KA rating | 6 | Each | 13,700 ₹82,200 Lowest | 17,000 ₹1,02,000 | 15,200 ₹91,200 | 16,500 ₹99,000 | 30,500 ₹1,83,000 | 15,400 ₹92,400 | 16,000 ₹96,000 |
| 1.06 | 4 Pole, MCCB, 350 Amps, Adjustable type,415V, with breaking capacity 36KA rating | 5 | Each | 12,550 ₹62,750 | 6,500 ₹32,500 | 15,200 ₹76,000 | 6,300 ₹31,500 | 30,500 ₹1,52,500 | 5,900 ₹29,500 Lowest | 7,000 ₹35,000 |
| 1.07 | 4 Pole, MCCB, 250 Amps, Adjustable type,415V, with breaking capacity 36KA rating | 7 | Each | 10,800 ₹75,600 | 17,500 ₹1,22,500 | 14,500 ₹1,01,500 | 1,600 ₹11,200 Lowest | 22,650 ₹1,58,550 | 15,800 ₹1,10,600 | 16,000 ₹1,12,000 |
| 1.08 | 4 Pole, MCCB, 200 Amps, Adjustable type,415V, with breaking capacity 36KA rating | 8 | Each | 7,500 ₹60,000 Lowest | 16,000 ₹1,28,000 | 14,000 ₹1,12,000 | 15,900 ₹1,27,200 | 21,500 ₹1,72,000 | 14,600 ₹1,16,800 | 15,600 ₹1,24,800 |
| 1.09 | 4 Pole, MCCB, 100-160 Amps, Adjustable type,415V, with breaking capacity 36KA rating | 9 | Each | 5,000 ₹45,000 Lowest | 9,000 ₹81,000 | 7,600 ₹68,400 | 8,600 ₹77,400 | 19,000 ₹1,71,000 | 8,200 ₹73,800 | 9,000 ₹81,000 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
21 Jul 2025, 6:00 pmClosed
GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
REPAIR REPLACEMENT AND MAINT OF LT SWITCH GEAR CAPACITOR BANK APFC PANEL SERVO VOLTAGE STABILIZER AND IMPROVEMENTS OF SUB STN INCL REPLACEMENT OF EARTHING CABLE DUCT COVER PAINTING REP OF PANELS REPLACEMENT OF GLOW SIGNS BOARD AT NS KARANJA
2025_MES_716309_1
8157/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE NW KARANJA
D and above b i
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹96,000
Yes
13 Nov 2025
23 Jun 2025
23 Jul 2025
23 Jun 2025
21 Jul 2025
7 Jul 2025
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .