Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest quoting | |
| 2 | L2₹23.4 L+₹4.7 L (24.8%)Rejected-AOC | L2 | Rejected-AOC Rejected being higher quoting | |
| 3 | L3₹24.6 L+₹5.9 L (31.2%)Rejected-AOC | L3 | Rejected-AOC Rejected being higher quoting | |
| 4 | L4₹26.8 L+₹8.0 L (42.7%)Rejected-AOC | L4 | Rejected-AOC Rejected being higher quoting |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
19 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Hisar
Garrison Engineer Hisar Military Station Hisar 125006
CA No GE(H)-69/2021-22 REPAIR / MAINT OF CERTAIN COOLING APPLIANCES AT HISAR MIL STN UNDER GE HISAR
2022_MES_514735_1
CA No GE(H)-69/2021-22
Open Tender
Miscellaneous Works
Item Rate
210 days
Hisar Mil Stn
As per Tender documents
7 documents required · 7 mandatory
₹500
GE Hisar
₹50,000
Yes
28 Apr 2022
22 Mar 2022
21 Apr 2022
22 Mar 2022
19 Apr 2022
6 Apr 2022
60 days
Amount
Taking down window/split type air conditioner of any capacity / make / size from site, opening top and side covers disconnecting all electrical controls components and cleaning the whole unit with electric blower and water gun spraying, descaling with coil shine solution in both side of cooling coil and condenser, brush cleaning with nylon brush and washing with clean water, refixing the covers and making electrical connection of all the controls and components, installing back the same on site and testing, commissioning incl painting with black corresive resistant paint coat to bottom complete.
M&L for Gas recharging in window/split type AC 1.5 Ton/ 2 Ton capacity of any make with R-22/R-32/R-134A as applicable including pressure testing, leakage rectification, vaccumising and testing commissioning complete.
S&F in replacement of PCB board suitable for 1.5/2 Ton Air Conditioner of existing make complete all as specified and directed.
S&F in replacement of copper pipe 7/8mm size with thermo insulation suitable for 1.5 / 2 Ton AC of existing make complete all as specified and directed.
S&F in replacement of copper pipe 14/15mm size with thermo insulation suitable for 1.5 / 2 Ton AC of existing make complete all as specified and directed.
Taking out old burnt / unserviceable compressor unit from window type / split type air conditioner 1.5 Ton capacity of any make and providing new rotary compressor sealed unit working on 230 Volts, 50 Hz including necessary welding / bracing work to existing referigerant pipes supply & charging regrigerant gas R-22/non CFC as applicable of required quantity, arresting leakages, re-installing in its proginal position / location, connecting up all electrical connections, testing commissioning complete all as specified and directed. Note : - (i) Compressor shall be got replaced from manufacturer or its authorized dealer. Necessary voucher and guarantee certificate shall be produced. (ii) Gas charging shall be measured and paid seperately under relevant item of BoQ.
Taking out old burnt / unserviceable compressor unit from window type / split type air conditioner 2.0 Ton capacity of any make and providing new rotary compressor sealed unit working on 230 Volts, 50 Hz including necessary welding / bracing work to existing referigerant pipes supply & charging regrigerant gas R-22/non CFC as applicable of required quantity, arresting leakages, re-installing in its proginal position / location, connecting up all electrical connections, testing commissioning complete all as specified and directed. Note : - (i) Compressor shall be got replaced from manufacturer or its authorized dealer. Necessary voucher and guarantee certificate shall be produced. (ii) Gas charging shall be measured and paid seperately under relevant item of BoQ.
S&F in replacement of starting capacitor 80/100 mfd suitable for 1.5 Ton / 2 Ton capacity Air conditioner all as specified and directed.
S&F in replacement of running capacitor 36/45 mfd suitable for 1.5 Ton / 2 Ton capacity Air conditioner all as specified and directed.
S&F in replacement of potential relay assembly suitable for 1.5/2 ton capacity Air conditioner all as specified and directed.
S&F in replacement of over load protector for suitable for 1.5/2 ton capacity Air conditioner all as specified and directed.
S&F in replacement of PVC air filter suitable for 1.5/2 ton capacity Air conditioner all as specified and directed.
S&F in replacement of blower aluminium/PVC suitable for 1.5/2 ton capacity Air conditioner all as specified and directed.
S&F in replacement of condenser fan suitable for 1.5/2 ton capacity Air conditioner all as specified and directed.
S&F in replacement of indoor unit kit with complete fittings like copper coil, temperature display, blower motor, PCB etc suitable for existing 1.5 ton capacity Split type Air conditioner complete all as specified and directed.
S&F in replacement of condenser fan motor 1/5 HP 230 volt AC single phase double shaft suitable for 1.5 ton window type AC complete all as specified and directed.
S&F in replacement of front grill suitable for window type air conditioner capacity 1.5 Ton as per existing make & model complete all as specified and directed.
S&F in replacement of copper condensor cooling coil assembly suitable for 1.5/2 Ton window type air conditioner of any make complete all as specified and directed. Note :- Charging of Refrigerant gas shall be measured and paid separately under relevant item of BoQ..
S&F in replacement of condenser assembly suitable for 1.5/ 2 Ton window type air conditioner complete all as specified and directed. Note :- Charging of Refrigerant gas shall be measured and paid separately under relevant item of BoQ..
S&F in replacement of fan motor of outdoor unit suitable for 1.5 /2 Ton capacity Split type AC capacity complete all as specified and directed.
S&F in replacement of fan motor of indoor unit suitable for 1.5 /2 Ton capacity Split type AC capacity complete all as specified and directed.
S&F in replacement of electronic control circuit plate suitable for 1.5 / 2 Ton capacity Split type AC including commissioning and testing complete all as specified and directed.
S&F in replacement of outdoor unit kit with complete fittings suitable for existing 1.5 ton capacity Split type Air conditioner complete all as specified and directed.
S&F in replacement of display assembly for deep freezer for reading inside temperature complete all as specified and directed.
Taking down water cooler of any capacity /make / size from site, transporting to work site and opening side covers of water cooler and disconnecting all components and controls and condenser fan motor, cleaning condenser with blower and washing with water and descaling with acid by spraying on both side of condensor. Cleaning with nylon brush and washing with clean water, refixing condensor fan motor, making electrical connection of relay, over-load etc. refixing side covers, installing back the same on site, testing and commissioning complete.
Taking down old unserviceable compressor of water cooler of capacity 40/80 litres any make/size and providing new company sealed compressor of same make as per existing duly filled with oil and connecting up suction and discharge copper pipe with gas welding, pressure testing of leakage, leakage rectification, vacumising and charging of refrigerant gas R-32/R-134A as applicable, testing, commissioning complete all as specified and directed.
All as per item No 27.00 here-in-before but water cooler of capacity 120 / 150 / 160 litres complete. Note for Srl item 27.00 to 28.00: - Compressor shall be purchased from authorised dealer of concerned manufacturer or company and necessary voucher and guaranty certificate shall be produced.
S&F in replacement of running capacitor suitable for water cooler of any cap complete all as specified and directed.
S&F in replacement of relay assembly suitable for any make & capacity of water cooler including replacement of cover & clip complete all as specified and directed.
S&F in replacement of internal wiring of water cooler of any make and capacity with flexible copper conductor wire, single core PVC insulated with thermal clips including replacement of screws & washers etc and fastening with body complete all as specified and directed.
S&F in replacement of overload protector suitable for any make & capacity of water cooler complete all as specified and directed.
S&F in replacement of starting capacitor suitable for water cooler of any cap complete all as specified and directed.
M&L for opening of water cooler any capacity, flushing out and removal of blockage, brazing etc replacement of liquid line filter and recharging the water cooler with R-32 / R-134A gas to obtain desired cooling as applicable including pressure testing, leakage rectification, vaccumising and testing commissioning complete.
S&F in replacement of push cock chromium plated 15 mm dia suitable for existing water coolers complete all as specified and directed.
S&F in replacement of fan motor of capacity 1/35 HP suitable for water cooler of capacity 40 / 80 litre complete all as specified and directed.
S&F in replacement of fan motor of capacity 1/10 HP suitable for water cooler of capacity 150 litre complete all as specified and directed.
S&F in replacement of water tap 15mm dia, self closing, cast copper alloy, chromium plated heavy duty suitable for water coolers complete all as specified and directed.
S&F in replacement of float valve assembly suitable for water cooler / desert cooler of any size/capacity non metallic PTMT symet body complete.
S&F in replacement of PVC waste pipe 40mm bore with fitting suitable for water cooler of any size/capacity complete all as specified and directed.
S&F in replacement of receptacle tray of size as per existing suitable for water coolers 40 / 80 litre capacity complete all as specified and directed.
Cleaning of water coolers body internally and externally including scraping and removing all scales and dirt etc, repairing the body to check leakage and unserviceable screws, nut, bolt, washers etc complete all as specified and directed.
S&F in replacement of PVC cable three core copper conductor multistranded & size 40/0.0076, 1100 V grade complete all as specified and directed.
Taking down old sealed unit of refrigerator any capacity of any make and providing new company sealed compressor of same size, make and capacity connecting up suction and discharge pipe with gas welding, pressure testing, flushing the complete system, leakage rectification vaccumising and charging of refrigerant gas R-32/R-134A as applicable, testing commissioning complete. Note : - Compressor shall be purchased from authorised dealer of concerned manufacturer or company and necessary voucher and guaranty certificate shall be produced.
M&L Charging of refrigerator with refrigerant gas R-22/R-134A/R-32 as applicable after vacuuming /pressure testing and leakage testing including flushing the system in the refrigerator of any make any capacity complete all as specified and directed.
S&F in replacement of refrigerator drier made out of copper tube suitable for any capacity refrigerator complete all as specified and directed.
S&F in replacement of freezer door cover (plastic) with tension spring suitable for refrigerators of any make & cap complete all as specified and directed.
S&F in replacement of freezer with cooling coil suitable for any capacity refrigerator of existing make complete all as specified and directed.
S&F in replacement of pigmy lamp (bulb) suitable for any make and capacity refrigerator complete all as specified and directed.
S&F in replacement of door liner (plastic) suitable for any capacity refrigerator of any make complete all as specified and directed.
S&F in replacement of fruit / vegetable tray (plastic) suitable for refrigerator of any make and capacity complete all as specified and directed.
S&F in replacement of ice tray (plastic) suitable for refrigerator of any make and capacity complete all as specified and directed.
S&F in replacement of Magnetic door gasket suitable for any capacity refrigerator of any make complete all as specified and directed.
S&F in replacement of relay box type suitable for refrigerator any capacity of any make complete all as specified and directed.
S&F in replacement of overlaod relay suitable for low/high speed refrigerator compressor of any capacity complete all as specified and directed.
M&L for opening of refrigerator any capacity, flushing out and removal of blockage, brazing etc replacement of liquid line filter and recharging the refregerant with R-32 / R-134A gas to obtain desired cooling as applicable including pressure testing, leakage rectification, vaccumising and testing commissioning complete. Note :- Cost of charging of gas is deemed to be included in quoted rate.
S&F in replacement of door lock with two keys suitable for any capacity refrigerator complete all as specified and directed.
Taking down old sealed unit of deep freezer any capacity of any make and providing new company sealed compressor of same size, make and capacity connecting up suction and discharge pipe with gas welding, pressure testing, flushing the complete system, leakage rectification vaccumising and charging of refrigerant gas R-32/R-134A as applicable, testing commissioning complete. Note : - Compressor shall be purchased from authorised dealer of concerned manufacturer or company and necessary voucher and guaranty certificate shall be produced.
M&L for opening of Deep freezer of 300 litres capacity, flushing out and removal of blockage, brazing etc replacement of liquid line filter and recharging the water cooler with R-32 / R-134A gas to obtain desired cooling as applicable including pressure testing, leakage rectification, vaccumising and testing commissioning complete. Note :- Cost of charging of gas is deemed to be included in quoted rate.
M&L for taking down desert cooler any size fixed in any position, cleaning internally and externally by scraping all scales, dirt etc, carrying out repairs to check leakages, replacing screws, nuts, bolts etc and applying painting to desert cooler with two coats of synthetic enamel hammer tone paint over a coat of red oxide primer by spray painting and refiing the desert cooler in existing position after necessary oiling and greasing of exhaust fan and water lifting pump complete all as directed.
S&F in replacement of fan motor 1/6 HP, 230 Volts, single phase, as per existing suitable for existing desert cooler complete all as specified and directed..
S&F in replacement of fan blade of metal body, set of three suitable for desert cooler motor of any sweep complete all as specified and directed.
S&F in replacement of water lifting submersible pump, 230 Volts, 50 C/S, single phase, suitable for desert cooler complete all as specified and directed.
S&F in replacement of high density polythene pipe 15 mm dia of superior quality (As per sample kept in GE’s office) complete all as specified and directed.
S&F in replacement of complete steel body of desert cooler of capacity 5000 CFM duly painted with two coats of synthetic enamel paint hammer tone paint over a coat of red oxide primer externally and one coat of anti-corrosive paint internally complete all as specified & directed.. The body of desert cooler shall be fabricated as under:- (a) Top and bottom shall be made out of 1.25mm thick GI sheet. (b) Side Panels shall be made of 1mm thick GI sheet. (c) Front grill shall be of suitable size and approved quality.
S&F in replacement of PVC water distributor 3 way for desert cooler of superior quality (As per sample kept in GE’s office) complete all as specified and directed.
S&F in replacement of electronic step type regulator suitable fo desert cooler fan motor complete all as specified and directed.
S&F in replacement of wood wool pad with bamboo strip support superior quality (As per sample kept in GE’s office) for desert cooler of capacity 5000 Cum/hr - 3000 Cum/hr having minimum weight 450 gms complete.
S&F in replacement of capacitor 4 mfd suitable for desert cooler complete all as specified and directed.
S&F in replacement of 4mm thick plywood commercial fixed in window for fixing desert cooler with fixing arrangement complete all as specified and directed.
M&F for repairs of automatic voltage stabilizer of any make and 5 KVA capacity by dismantling and taking out burnt transformer and re-winding the same with super enamelled copper wire of suitable size incl varnishing, cleaning, servicing, tightening of loose connection/ joints of all the controls/components to make the voltage stabilizer in serviceable condition complete. Note :- Any component/control if replaced shall be measured & paid separately.
M&F for repairs of automatic voltage stabilizer of any make and 3 KVA capacity by dismantling and taking out burnt transformer and re-winding the same with super enamelled copper wire of suitable size incl varnishing, cleaning, servicing, tightening of loose connection/ joints of all the controls/components to make the voltage stabilizer in serviceable condition complete. Note :- Any component/control if replaced shall be measured & paid separately.
S&F in replacement of main transformer of 0.5 to 5 KVA capacity voltage stabilizer complete.
S&F in replacement of relay assembly suitable for single phase 5 KVA capacity voltage stabilizer complete.
S&F in replacement of relay assembly suitable for single phase 3 KVA capacity voltage stabilizer complete.
S&F in replacement of volt meter 0-300 volts, square type of size 96mmx96mm all as specified and directed.
S&F in replacement of time relay suitable for 2 to 5 KVA capacity voltage stabilizer complete all as specified and directed.
S&F in replacement of electronic printed control card suitable for any make of capacity upto 5 KVA voltage stabilizer complete all as specified and directed.
S&F in replacement of double ended fan mortar 1/6 HP cap suitable for window type AC 1.5 Ton capacity complete all as specified and directed.
S&F in replacement of capillary tube and strainer suitable for split type AC 1.5 / 2 ton capacity complete all as specified and directed.
S&F in replacement of remote control with cord wire suitable for split type AC 1.5 / 2 ton capacity complete all as specified and directed.
fauji electric works
m/s Rajesh Kumar
M/S RAJENDRA KUMAR AGARWAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .