| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹6.7 L+₹30,688 (4.78%)Rejected-Finance R O H NO 55 SEC D BHARAT NAGAR TALAB TILLO JAMMU 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹7.1 L+₹64,288 (10.0%)Rejected-Finance H NO 309 REHARI COLONY JAMMU DISTT JAMMU J K 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹7.1 L+₹68,355 (10.7%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹7.2 L+₹75,144.25 (11.7%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
12 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(I) 873 EWS
Garrison Engineer (Indep) 873 Engineer Works Section PIN 913 873 C/O 56 APO
REPAIR REPLACEMENT OF STREET SECIRITY LIGHT AND OTHER CONNECTED ITEMS AT BNII BNIII MRS CHINTA AND JAIGHATI UNDER GE (I) 873 EWS
2023_MES_595274_1
NIT-16 of 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bhderwah
As per NIT
7 documents required · 7 mandatory
₹500
GE(I) 873 EWS
₹18,000
Yes
19 Jul 2023
13 May 2023
14 Jun 2023
13 May 2023
12 Jun 2023
27 May 2023
Amount
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Ditto all as per item no. 1 here-in-before but exceeding 1.5metre depth but not exceeding 3.0metre depth.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated soils to a distance exceeding 50m but not exceeding 100m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Sand cushioning to underground cables using new dry river sand laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete, punned to 18cm, complete all as specified and directed Note : Punned thickness of 18cms shall be measured for payment.
Supply and laying brick covering with width equal to length of bricks as mechanical protection to underground cable using old size sub class 'B' bricks, laid flat size 230mm x 115mm x 75 mm with width of brick perpendicular to length of cable, all as specified and directed.
Cement concrete type D-2 1:4:8 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Cement concrete type C-2 1:3:6 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Cement concrete type B-1 1:2:4 (using 20mm graded crushed stone aggregate) as in coping of poles, complete all as specified and directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 10 Sqmm 4 core on wall including taking down old cable, complete all as specified and directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 16 Sqmm 4 core on wall including taking down old cable, complete all as specified and directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 25 Sqmm 3.5 core on wall including taking down old cable, complete all as specified and directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 35 Sqmm 3.5 core on wall including taking down old cable, complete all as specified and directed.
LED street light 60 Watt, 230V, AC, new generation energy saving and environmental friendly long life, outdoor type with high pressure die sast aluminium hosing heat resistance complete with driver, lamp, bracket with impact and corrosion resistance including thermal management in multipale optics complete with IP 65/66 protection device complete, fixed in repair all as specified and directed. (Make :Havells Endura pearl plus L60WLED757SASYTOPC or equivalent in Wipro/Philips/Crompton)
Pole mounting bracket made out of medium grade GI pipe of 40mm dia, bent to 600 required shape of length 1.5 mtr with two No's of flat iron clamps made out of 32 x 6mm with 12mm dia bolts, nuts & washers duly painted with aluminium paint over a coat of primer including taking down old unserviceable brackets all as specified and directed.
LED flood light fitting 100 Watt 230V AC outdoor type with thermal management in multiple optics and equipped with IP66 Protection with impact and corrision resistance complete with driver and lamp including taking down old unserviceable fitting all as directed. Make : Havells cat part SYMLTG or equivalent in Wipro / Philips / Crompton
PVC junction box of size 250mm x 250 mm x 160 mm with hinged type door and 2 Nos terminal 20 Amps MCB, fixed on pole withnecessry fixing arrengment such as nuts, bolts, washers, clamps, etc complete, fixed in repair all as specified and as directed. (Make- Sintex cat part No GSJB-2520 or equivalent)
PVC insulated copper conductor 2.5 Sqmm for connecting Street Light fitting to DB passing into the pole complete including taking down old unserviceable cable all as specified and as directed.
MCCB 63 Amps, breaking capacity 16 KA, TP, 415V (adjustable thermal and magnetic release) fixed in replacement complete all as specified and directed.
MCCB 100 Amps, breaking capacity 16 KA, TP, 415V (adjustable thermal and magnetic release) fixed in replacement complete all as specified and directed.
MCCB 160 Amps, breaking capacity 36 KA, FP, 415V (adjustable thermal and magnetic release) fixed in replacement complete all as specified and directed.
Sheet metal enclosure DB SPN 240 volts 2 way single door type for fixing MCB complete, fixed in replacement all as specified and directed.
Sheet metal enclosure DB SPN 240 volts 4 way single door type with 200 amps rated bus bar for fixing MCB complete, fixed in replacement all as specified and directed.
MCB 6-32 Amps SP 'C' series 240 V, 50 Hz, breaking capacity 10 KA suitable for lighting and other domestic loads complete, fixed in replacement all as specified and directed. (Make: ABB / Siemens / Legrand / Havells / Scheinder)
MCB 40 Amps SP 'C' series 240 V, 50 Hz, breaking capacity 10 KA suitable for lighting and other domestic loads complete, fixed in replacement all as specified and directed. ((Make: ABB / Siemens / Legrand / Havells / Scheinder)
MCB 32 Amps SPN 'C' series240 V, 50 Hz, breaking capacity 10 KA,fixed in replacement all as specified and directed. (Make: ABB / Siemens / Legrand / Havells / Scheinder)
MCB 40 -63 Amps SPN 'C' series240 V, 50 Hz, breaking capacity 10 KA fixed in replacement all as specified and directed. (Make: ABB / Siemens / Legrand / Havells / Scheinder)
MCB TPN/FP 16 to 32 Amps 415 V 50 Hz, breaking capacity 10 KA 'C' curvecomplete with connection testing and commissioning, fixed in replacement all as specified and directed. (Make: ABB / Siemens / Legrand / Havells / Scheinder)
Painting of steel tubular pole any type with cross arms with one coat of aluminium paint after preparation of surfaces of pole / cross arms by scrapping of old paint, cleaning of all rusted surface and painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface of pole and cross arms structure over one coat of primer and marking of MES No complete all as specified and directed.
Steel Tubular swaged poles type 410 SP-31 (9.0 mtr long) conforming to IS : 2713 Part-I to III 1980, complete with 6 mm thick mild steel base plate, finial taper plug, MS bolts, nuts, screws including painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface over one coat of primer complete including taking down old unserviceable Pole all as specified and directed.
Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, drilling holes for bolts, in any shape or size as indicated or directed and also inclusive of two coats of aluminium paint over one coat of red oxide primer including dismantling / taking down old unserviceable structural steel all as specified and as directed.
Pin type porcelain in replacement, vitreous white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100mm height, 65mm dia for 1100 volt complete including taking down old unserviceable insulator complete all as specified and directed.
Shackle type insulator porcelain vitreous white, brown or green including galvanised M.S. straps 31 x 5mm size, 75mm height, 90mm dia including galvanised mild steel straps, nut, bolts washers complete for 1100 volts grade insulator complete including taking up of old UNSV Shackle type complete all as specified and directed.
Restringing / Restretching / Tightening of old ACSR conductor of any size and make on HT / LT Poles by disconnecting and removing from insulators including providing necessary binding wire and jumpering after proper stringing all as directed. (Note:The unit of measurement is 'SPAN' i.e. distance covered between two poles).
Aluminium conductor steel reinforced (ACSR) including binding to insulator with suitable size of binding wire and size of conductor Weasel (6/1 x 2.59 mm), Squirrel (6/1 x 2.11mm) or Ferret (6/1 x 3.00 mm) including taking down old ACSR conductor, complete all as specified and as directed.
Cutting and trimming of trees and branches to clear the over head line in the arc of HT/LT over head line feeders and removal of the trimmed branches of trees complete all as specified and directed. Notes : 1. Any ACSR conductor damaged during the cuttings of trees / branches shall be repaired and jointed / fixed by the contractor, to the entire satisfaction of Engr-in-Charge, without any extra cost and nothing extra shall be admissible from the department on this account what-so-ever. 2. The cutting / trimming of tree branches shall be done to at least 2.00 metre radius of OH line. 3. The unit of measurement is 'SPAN' i.e. distance covered between two poles.
Stay Assembly using stay rod of 20mm dia complete accessories as shown in Electrical Plate No 1 of SSR 2009 Part-I such as loop type insulator, porcelain, vitreous white/ brown or green, large size with overall dimensions 90 x 140mm clearance of hole 16mm, stay wire of size 7/4mm etc., including taking down old, complete all as specified and directed. Note: Excavation and concrete shall be measured and paid separately.
Supply & fix loop type insulator vitreous porcelain, white, brown or green small size with overall dimensions 65x90mm, clearance of hole 16mm dia all as specified.
Supply & fix galavanised stay strand with wire of size 7/3.15 mm all as required at site or shown in electrical plate No. 1 complete all as specified.
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point complete, all as specified and testing on completion.
M/S Chib Engineers
M/S A K ENGINEERS & CO.
M/S Builders Indias
narayan construction
Bidder Name
M/S Chib Engineers
M/S Builders Indias
CONTRACTORS INDIA
M/S A K ENGINEERS & CO.
narayan construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .