Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹37.2 LAccepted-AOC 355 85 GALI NO 16 ASHOK VIHAR PHASE II BHIM GARH KHERI ASHOK VIHAR PHASE II GURGAON GURGAON HARYANA 122001 | GURUGRAM | HARYANA | 122001 | 1 | Accepted-AOC L-1 firm | |
| 2 | 2₹38.4 L+₹1.2 L (3.27%)Rejected-Finance D 3 195 CHITRAKOOT NAGAR AJMER ROAD JAIPUR JAIPUR RAJASTHAN 302021 | JAIPUR | RAJASTHAN | 302021 | 2 | Rejected-Finance L-2 BIDDER | |
| 3 | 3₹39.2 L+₹2.0 L (5.39%)Rejected-Finance | 3 | Rejected-Finance L-3 BIDDER |
Tender Value
₹42.6 L
EMD Value
₹85,240
Closing Date
26 Sept 2022, 3:00 pmClosed
Controller of Administration
CSIR CEERI PILANI
SITC of VRV VRF type air conditioners for Central workshop Gyrotron lab Old administrative block at CSIR CEERI Pilani Rajasthan
2022_CSIR_129000_1
13-8(163)/2022-EME
Open Tender
Electrical Works
Works
90 days
CSIR CEERI PILANI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Director CSIR CEERI PILANI
₹85,240
28 Oct 2022
20 Sept 2022
28 Sept 2022
20 Sept 2022
26 Sept 2022
20 Sept 2022
Amount
Supply, Installation, Testing Commissioning of VRV/VRF Outdoor machines for air conditioning system, comprising of scroll/screw/rotary compressors with R-410A/R-32 refrigerant, DC fan motor with fan blade, heat exchanger, safety valves, solenoid valves receiver, capillary tubes, checks valves, electronic expansion valves, low pressure sensor, refrigerant filter, stop valve, Y-joints/refnet kits and making joints etc. Rate inclusive of refrigerant and oil pre charging, vibration isolators, supports, necessary foundation/pedestal works etc. Condenser coil & fins provided with anti corrosive treatment, necessary accessories for oil separation, flow control, interconnecting piping, condenser air fan, electrical and microprocessor based panel, interconnecting cabling, all housed inside a weather proof cabinet suitable for exposed installation on ground including pressure testing, vaccuming, charging of refrigerants etc. as per requirement for proper functioning of the units. Preferable Make: Hitachi, O’General, Daikin, Blue star
Outdoor machines (cooling only)- 18HP
Outdoor machines (cooling only)- 16HP
Outdoor machines (cooling only)- 12HP
Outdoor machines (cooling only)- 5HP
Supply, Installation, Testing Commissioning of VRV/VRF indoor units with wireless remote controller, multi speed blower, high efficient filter, inbuilt microprocessor, including cooling coil of copper tubes and aluminium fins, drain pan, indoor unit mounting plate etc. Indoor units along with remote control must compatible with outdoor machines.Preferable Make: Hitachi, O’ General, Daikin, Blue star
Wall mounted type indoor unit (Cooling only )- 2.0TR
Supply and fixing of set of hard drawn suction and discharge refrigerant copper pipes (thickness should not less than 0.9 mm) of suitable size for above VRF/VRV units with fittings like elbows, couplers, reducers, tee, Y-joints/Refnet joints etc. Refrigerant pipes duly insulated with elastomeric nitrile tubular rubber insulation between indoor & outdoor unit. Preferable Make: Rajco/Mandev/yorkshire/Totaline/vaishali/Maxflow /Parasmani
Supplying and fixing following size powder coated M.S. 'C' channel type trays with cover (for refrigerant pipes) including connectors, bend, tee etc. and fitted on wall/floor/ roof with M.S. fasteners, supports, clamps/MS hanger etc. as required.
100 mm width X 50 mm depth X 0.9 mm thickness
200 mm width X 75 mm depth X 0.9 mm thickness
Supply and fixing of heavy duty rigid UPVC piping (for drain) on wall complete with fittings and clamps/supports etc. The joints shall be properly sealed with rubber based adhesive to ensure proper bonding. The rate shall include UPVC Coupler, reducer, socket, bend, Tee as required as per the site to connect with the Drain Hopper of IDUs.
25 mm dia. rigid U PVC pipe.
Supplying and Fixing of following sizes powder coated M.S. stand for all outdoor units, including Fasteners (Fischer) & Fixtures etc. Complete in all respect.
M.S. stand(18 hp outdoor machine)
M.S. stand(16 hp outdoor machine)
M.S. stand(12 hp outdoor machine)
M.S. stand(05 hp outdoor machine)
Supply and laying of following sizes of FRLS PVC insulated flexible copper conductor cable of 1.1 KV grade for power supply to indoor unit i/c providing and laying of suitable size PVC casing capping from power point to indoor unit on surface and where ever required etc. as required. Preferable Make: Finolex, KEI, Havells, Polycab, L&T,RR
3C x 1.5 Sq.mm cable
Supply and laying of following size overall shielded Control cum Communication cable in suitable PVC conduits between indoor and outdoor units. Preferable Make: Finolex, KEI, Havells, Polycab, L&T,RR,Universal.
2C x 1.0 Sq.mm shielded cable
Supply of following sizes of 1.1KV grade Copper conductor XLPE insulated and PVC sheathed armoured cable conforming to IS : 7098 (Part-I) 1988 of as required.Preferable Make: KEI, Havells RPG, Unistar,Skytone, Polycab.
3.5core x 50 Sq.mm. Copper Cable
3.5core x 25 Sq.mm. Copper Cable
Providing and fixing 4.00 mm dia. copper earth wire on surface or in recess for loop earthing along with existing surface / UG cable as required.
Laying and fixing of PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface with supports clamps etc. as required.
Above 35 sq.mm and up to 95 Sq.mm
Up to 35 sq.mm
Supply& making one end termination with heavy duty single compression brass gland SIBG type, copper lugs duly crimped with crimping tool, PVC tape etc. for following size of armoured PVC insulated & PVC sheathed copper cable of 1.1 KV grade as required.
3.5core x 50 Sq.mm. Copper Cable
3.5core x 25 Sq.mm. Copper Cable
Acme Engineering Systems
Shree Karni Electrovision
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .