| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC 1 OPP NAGAR NIGAM KATNI MAIN ROAD KATNI MADHYA PRADESH 483501 | KATNI | MADHYA PRADESH | 483501 | ₹1.4 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹2.1 Cr+₹63.3 L (44.6%)Rejected-AOC | ₹2.1 Cr+₹63.3 L (44.6%) | L2 | Rejected-AOC Rejected |
Tender Value
₹1.1 Cr
EMD Value
₹1.8 L
Closing Date
15 Aug 2022, 6:00 pmClosed
CWE (AF) Tughlakabad
HQ CWE (AF) Tughlakabad, New Delhi-110080
PROVN OF DEFICIENT STORAGE ACCN FOR LOGISTIC SECTION AT AF STN NAJAFGARH UNDER GE (AF) TUGHLAKABAD
2021_MES_481982_8
CA NO. CWE/TKD/TOKEN-44/2021-22
Open Tender
Civil Works
Lump-sum
334 days
GE (AF) Tughlakabad
As per NIT conditions
8 documents required · 8 mandatory
₹1,000
GE (AF) Tughlakabad
₹1.8 L
Yes
17 Nov 2022
18 Jul 2022
17 Aug 2022
18 Jul 2022
15 Aug 2022
1 Aug 2022
Amount
Lumpsum price worked out by the contractor for "Building work" as listed in Sch 'A' Part -I above/below the lumpsum price of Rs 9500000.00 as inserted by MES for Sch 'A' Part -I on srl page No 21.
Lumpsum price worked out by the contractor for "Site clearance, Earth Work and Excavation" as listed in Sch 'A' Part II above/below the lumpsum price of Rs 246662.79 as inserted by MES for Sch 'A' Part -II on srl page No 22.
Lumpsum price worked out by the contractor for "Sewage Disposal" as listed in Sch 'A' Part III above/below the lumpsum price of Rs 135539.14 as inserted by MES for Sch 'A' Part -III on srl page No 23.
Lumpsum price worked out by the contractor for "Area Drainage" as listed in Sch 'A' Part IV above/below the lumpsum price of Rs 1145260.01 as inserted by MES for Sch 'A' Part -IV on srl page No 25.
Lumpsum price worked out by the contractor for "Hard Standing" as listed in Sch 'A' Part V above/below the lumpsum price of Rs 924102.50 as inserted by MES for Sch 'A' Part -V on srl page No 26.
Lumpsum price worked out by the contractor for "Internal Electrification " as listed in Sch 'A' Part VI above/below the lumpsum price of Rs 938572.46 as inserted by MES for Sch 'A' Part -VI on srl page No 31.
Lumpsum price worked out by the contractor for "External Electrification" as listed in Sch 'A' Part VII above/below the lumpsum price of Rs 109898.34 as inserted by MES for Sch 'A' Part -VII on srl page No 32.
Lumpsum price worked out by the contractor for "Aluminium Works" as listed in Sch 'A' Part VIII above/below the lumpsum price of Rs 206166.40 as inserted by MES for Sch 'A' Part -VIII on srl page No 33.
Lumpsum price worked out by the contractor for "Internal Water Supply" as listed in Sch 'A' Part IX above/below the lumpsum price of Rs 15702.74 as inserted by MES for Sch 'A' Part -IX on srl page No 34.
Sch 'A' Part-X (Miscellaneous B&R / E&M Items) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 signifies this fact only.
S&F SFRC factory made drain cover/ man hole cover size 1100mmx550mm and 70 mm thick, with steel flat complete all as specified and directed.
S&F SFRC factory made drain cover/ man hole cover size 1200mmx600mm and 70 mm thick, with steel flat complete all as specified and directed.
Cleaning of open/covered drain and hume pipes, culverts etc and the like of any type, size of any description for silt/ earth accumulated due to storm water and spreading the cleaned earth where directed. Note :- cover slabs to be removed and refixed after cleaning with cement mortar 1:4 where covered drain exist complete all as specified and directed.
M&L for 1x 20 watts ( 4 feet) wall mounted LED batten,extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver including lamp complete all as specified and as directed.
M&L for 1x 9/10 watts ( 2 feet) wall mounted LED batten,extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver including lamp complete all as specified and directed.
M&L for ceiling fan 1200 mm sweep, five star rating, white colour complete AC single phase 230 volts and connecting with flexible cable 3 core copper conductor of size 23/0.0076 of suitable lenght from ceiling rose complete all necessary arangement of hanging of ceiling fan (GI Pipe hook etc ) as specified and directed.
M&L for PVC exhaust fan of size 300 mm sweep, 1400 RPM single phase, single phase,230 Volt AC 50 Hz with louver shutter / grill and connection complete all as specified and directed.
M&L for PVC exhaust fan of size 450 mm sweep, 1400 RPM single phase, single phase,230 Volt AC 50 Hz with louver shutter / grill and connection complete all as specified and directed.
Supply and fixing LED street light 35/36 watt IP 65 complete all as specified and directed.
M&L for MCB single pole 240 volts, C curve-10 KA 16 Amp complete all as specified and directed.
M&L for MCB single pole 240 volts, C curve-10 KA 06 Amp complete all as specified and directed.
M&L for MCB single pole & neutral 240 volts, C curve-10 KA 40-60 Amp complete all as specified and directed.
S&F porcelain insulator on angle iron frame for mounting of strip heater all as required complete all as specified and directed.
Supply and laying well burnt bricks sub class 'B' locally available of old size in trenches for protection of underground cable complete all specified and directed.
Taking out old existing serviceable underground cable of any sizes and any capacity from trenches/pipes complete all specified and directed. Note : Necessary earth work such are exavation, returning filling shall be measured and paid seperately under respective item of earth work schedule.
Relaying of existing under ground cable of size 70 Sqmm 3.5 core and 50 Sqmm 3.5 core complete all specified and directed.
Taking out old existing serviceable GI pipe line of any sizes and any capacity from excavated trenches complete all specified and directed. Note : Necessary earth work such are exavation, returning filling shall be measured and paid seperately under respective item of earth work schedule.
Relaying of existing GI pipe line of size 60 mm dia complete all specified and directed.
Shifting of existing panel from old location to new location distance approx 35 Mtr incluing taking existing panel and disconnecting of all existing cable connection and then refixing of existing panel at new location including necessary earth work, cement work and connections and testing etc complete all specified and directed.
Supply, installation, testing and commissioning air cooled split unit air conditioner electric driven, single phase of capacity of 2.0 TR, BEE 5 star rated including necessary initial gas charging, all tubing , insulation , drain pipe upto 5 meter and all accessories complete including plateform of required size for mounting out door unit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and finishing the top surface even and smooth with using extra cement and necessary PVC insulated copper wire 03 core complete all as specified and directed. Make: Hitachi/ Blue star/ Carrier
Supply, installation, testing and commissioning air cooled split unit air conditioner electric driven, single phase of capacity of 1.5 TR, BEE 5 star rated including necessary initial gas charging, all tubing , insulation , drain pipe upto 5 meter and all accessories complete including plateform of required size for mounting out door unit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and finishing the top surface even and smooth with using extra cement and necessary PVC insulated copper wire 03 core complete all as specified and directed. Make: Hitachi/ Blue star/ Carrier
S&F voltage stabilizer 5 KVA for automatic operation , single phase naturally air cooled indoor type, and designed for input variation betwwen 170 V to 250 V with output voltage stabilized at 230 V with accuracy of + 2.5 % and capacity complete all as specified and directed.Make: Bluebird/ volina/ V gaurd
Gaurav Construction Company
Bidder Name
Neeraj Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .