GE(SB) Karwar
GE (Seabird) Karwar Naval Base Karwar
REPAIR MAINT OF STREET, SECURITY LIGHT FITTINGS, HIGH MAST LIGHTS, TRANSIT LIGHTS, JETTY TOWER LIGHTS AND CONNECTED WORKS AT KADAMBA VANAM, MANZIL CREEK IN NSRY, CT POOL, WED, PATANJALI ETC UNDER GE(SEABIRD) KARWAR
2021_MES_485817_1
8848/E8
Open Tender
Civil Works
Item Rate
330 days
GE (Seabird) Karwar Naval Base Karwar
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE(Seabird) Karwar
₹88,000
Yes
8 Feb 2022
2 Nov 2021
30 Nov 2021
2 Nov 2021
23 Nov 2021
16 Nov 2021
Amount
Taking down carefully old defective LT UG cable of any size including cable protection pre cast concrete cover / bricks from the trenches and keeping aside for reuse/ disposal complete all as specified and directed.
Supply, laying, jointing and testing of LT underground XLPE insulated screened PVC bedded, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade of cross-sectional area 16 Sqmm, 4 core, conforming to IS-7098 (Part-I) of 1988 laid in trenches/ wall/ floors/ ducts etc fixed with saddle and clamps or passing through pipes complete with cable and connection with proper thimbles, nuts, bolts and washers all as specified and directed. (Excavation & earth work, sand cushioning and PCC cover for cable protection will be measured & paid for seperately.)
Description all as per item No 2.00 above but cross sectional area 10 Sqmm 4 core.
Description all as per item No 2.00 above but cross sectional area 25 Sqmm 3.5 core.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth for laying/ taking out cable and getting out in soft/ loose soil all as specified and directed.
Description all as per item No 5.00 above but depth exc 1.5 m but not exc 3.00 m.
Returning, filling in soil including spreading levelling, watering and well ramming in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material/ soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and directed.
Supply and spread dry river sand in trenches for cable cushioning all as specified in clause 19.75 of SSR Part-I. NOTE: Punned thickness of sand only will be measured & paid.
Supply and laying in repairs un-reinforced pre-cast concrete cable cover, class LV, type 1, flat, size 250 mm x 150 mm x 40 mm complete all as specified and directed.
Laying only un-reinforced pre-cast concrete cable cover, class LV, type 1, flat, size 250 mm x 150 mm x 40 mm complete all as specified and directed.
Supply and laying in repairs galvanised iron tubing, light grade of size 40 mm dia with all fittings as in cable protection, laid in trenches, including taking down existing unserviceable GI pipes & its connections complete all as specified and directed by Engr-in-Charge.
S & F in repairs new generation, post top lantern or garden light fitting 25 W LED, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with driver complete all as specified and directed by Engr-in-Charge. MAKE: Havells Cat Part No CORALPT25WLED757PSYMTOPC, HSN Code - 9405 or equivalent in CG/Bajaj/Phillips
S & F in repairs contactor MNX-32, 3 Pole, 415 volt coil voltage 230 volt complete as in street light timer assembly including removing old unserviceable contactor all as specified and directed by Engr-in-Charge. MAKE: L&T Cat Part No CS94111 or equivalent in Siemens/ABB/GE/ Schneider
S & F in repairs for contactor MNX-40, 3 Pole, 415 volt coil voltage 230 volt complete as in street light timer assembly including removing old unserviceable contactor all as specified and directed by Engr-in-Charge. MAKE: L&T Cat No CS94190 or equivalent in Siemens/ABB/GE/ Schneider
S & F in repairs for digital weekly programmable time switch for controlling street lights Single Phase 230 volt complete of capacity 15/16 Amp complete all as specified and as directed by Engr-in-Charge. MAKE: Havells Cat Part No DHTJW01016 or equivalent in L&T/Siemens
S & F in repairs MCB Triple Pole & Neutral, 40 to 100 Amp, 415 Volts, 10 KA capacity, 'C' curve series in the DB/ Panel complete with connection testing & commissioning complete all as specified and directed. MAKE: Indo Asian Cat Part No 810098 or equivalent in Legrand/ Schneider/ Seimens /L&T
S & F in repairs MCB, single pole 6 to 32 Amp, 240 Volts, 10 KA Capacity 'C' curves series in the DB/ Panel complete with connection testing & commissioning complete all as specified and directed. MAKE: Indo Asian/ Legrand /Schneider/Seimens/ L&T .
S & F in repairs FRP cable looping boxes of size 300 mm x 200 mm x 105 mm with TPN aluminium bus bar and MCB SP 6 Amp- 01 No, 10 KA breaking capacity, 'C' curve series, factory made with PVC sheet including heavy duty connector for connection of 4 core cable & fixed to pole with suitable size flat iron clamp, nuts & bolts complete all as specified and directed by Engr-in-Charge. MAKE :Sintex or as approved by GE.
S & F in repairs PVC insulated and sheathed copper multistranded cable three core, 1.5 sqmm, heavy duty through or on pole connecting to cable looping box of street light fitting all as specified & directed.
S & F in repairs PVC insulated and sheathed copper multistranded cable three core, 2.5 sqmm, heavy duty through or on pole connecting to cable looping box of street light fitting all as specified & directed.
S & F in repairs two way heavy duty PVC connector suitable for 10 or 16 Sqmm cable connection in looping box complete all as specified & directed.
S & F in repairs aluminium thimbal/ lugs of size 10 to 25 Sqmm for cable connection as per site requirement complete all as specified and directed by Engr-in-Charge.
M & L for preparation of old surface by scrapping down old peeled off paint using sand paper, removing dirt/ dust from steel tubular pole and painting to steel tubular pole (9 m long) including street light bracket and applying two coats of aluminium paint including marking the pole number etc complete all as specified and directed.
Taking down carefully existing old unserviceable street/ roadway/ flood light fitting of any type/ size from poles/ bldgs of any type/ height and deposit the same to MES store/ Sub Station where directed for repair/ reuse/ credit complete all as specified & directed by Engr-in-Charge.
S & F 90 Watt LED roadway luminaire, led street light made up of pressure die cast aluminium housing with high power led as lighting source and lens embedded PC cover having top opening separate driver compartment with IP66 protection and impact resistance of IK07 with 10 KV built-in surge Protection device with high power LEDs as light source and HF electronic driver of 200 W capacity including making necessary connection complete all as specified and directed. MAKE: Havells Cat No. ENDURAPEARLPLUSSL90WLED757PASYTOPCASTHO or equivalent in Bajaj/ CG/ Philips
S & F 200 Watt LED flood light energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium non integral IP66 flood light, suitable for high mast application, highlighting architectural facade and general purpose lighting with high power LEDs as light source and HF electronic driver & control gear box of 200 W capacity including making necessary connection complete all as specified and directed . MAKE: Havells Cat Part No JetaValourfl200Wled757modnBltG and for CG box Cat No assemBledCGBoXValour200WaP or equivalent in Bajaj/ CG/ Philips
S & F LED flood light luminaire 180 Watt with secondary optics innovative die-cast aluminium flood light with highly efficient LEDs as light source, suitable for highlighting architectural features or retail spaces IP66 protection complete all as directed by Engr-in-Charege. MAKE: Havells Cat Part No JetaValourfl180Wled757PintnBltG or equivalent in Bajaj/ CG/ Philips
M & L for earthing complete with galvanized cast iron earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of earth plate not less than 1.5 m below normal ground level connected to galvanized iron strip 25 x 4 mm as earthing lead by means of bolts, nuts, washers and check nuts of steel/ GI duly protected with 15 mm bore light grade pipe upto main board, 20 mm bore watering pipe light grade with CI/ MS funnel and wire mesh including excavation, earth work in any type of soil and removing the surplus soil to a distance not exceeding 50 m, charcoal dust and common salt in adequate qty all as shown in electrical plate No 3 of SSR Part-I 2009 having pit and cover in PCC 1:2:4 type B-1 including angle iron frame made of angle iron of size 40 mm x 40 mm x 6 mm grouted in PCC pit for PCC cover, funnel with wire mesh complete and all as specified and directed by Engr-in-Charge. NOTE: The unit rate quoted shall be deemed to include for necessary excavation and earth work, PCC 1:3:6 type CI chamber, funnel with GI medium grade watering pipe 15 mm bore, RCC cover slabs 50 mm thick with 8 mm dia CTD bars @ 140 mm c/c both ways etc complete.
S & F in repairs gate or garden light any type or size, supply and fixing decorative gate light including 1 x 20 W LED lamp made up of high grade unbreakable polycarbonate material suitable for retrofit LED lamp B22 base IP65 complete all as specified and directed by Engr-in-Charge. MAKE FOR GATE LIGHT: Havells Cat Part No LHFXAMN1TN6F035 or equivalent in Bajaj/CG/Philips. MAKE FOR LED LAMP: Havells Cat Part No LHLDEUEEMC8R020 or equivalent in Bajaj/CG/Philips.
Supply and errecting truly to vertical position steel tubular swaged pole complete with cast iron base plate welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (9 m long) including one coat of red-oxide zinc chrome primer and two coats aluminium paint on surfaces, exposed to view and making 30 cm wide strips (Total 5 Nos) with yellow and black paint alternately on external surface above PCC benching including writing pole No with letters/ figures of size not exc 30 mm with black paint on a yellow circle of dia 75 mm after painting, complete including dismantling of old steel tubular pole all as specified and directed by Engr-in-Charge. MAKE: Bajaj or equivalent as approved by GE. NOTE: PCC, Earth Work shall be measured and paid separately under respective items.
M & L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate for coping etc as mass concrete complete and all as specified and directed by Engr-in-Charge.
M & L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate for foundation of pole, stay assembly etc as mass concrete complete and all as specified and directed by Engr-in-Charge.
S & F in repairs LED driver suitable for 90 Watt LED street light fittings complete all as specified and directed by Engr-in-Charge. MAKE: Havells//Bajaj/CG/Philips.
S & F in repairs solar charge controller box in jetty transit lights all as specified and directed. MAKE: Luminous Model No: SCC1210NM / Tata BP solar or equivalent as approved by GE. NOTE: Quoted rate shall be inclusive of fixing charges at break water signal lights through gemini/ boat. Transportation to be provided by Dept.
S & F in repairs Marine Lantern, Red/ Green INA LED 72, 7 NM at 0.74 ATF for Break water/Jetty signal lighting, polycarbonate plastic sealed IP68 protection,185 mm dia, bird spike provided on top of lens, automatic On/Off by photo cell, high intensity LEDs with 100,000 hours of life, input voltage 12 V DC fixing on PCD four holes for M8 bolts weighing approx 2.5 Kg per unit fixed at break water all as specified and directed. MAKE: India Navigation Aids Model No. INA LED 72 or equivalent as approved by GE. NOTE: Quoted rate shall be inclusive of fixing charges at break water signal lights through gemini/ boat. Transportation to be provided by Dept.
S & F in repairs solar panel 165 Watt, 12 V of transit lights at break water signal lights all as specified and directed. MAKE: Luminous/ Tata/ Supreme NOTE: Quoted rate shall be inclusive of fixing charges at break water signal lights through gemini/ boat. Transportation to be provided by Dept.
S & F in repairs and install maintenance free battery of capacity 12 volts 150 AH including disconnecting old unserviceable battery complete all as specified and directed. MAKE: EXIDE Model No 6SGL150 Tubular GEL VRLA Solar SOLATRON Battery or equivalent in Luminous NOTE: Quoted rate shall be inclusive of fixing charges at break water signal lights through gemini/ boat. Transportation to be provided by Dept.
S & F in repairs battery protection cover as per existing size made out of 3 mm thick MS sheet and angle iron frame of size 25 x 3 mm including painting with two coats of existing colour over a coat of red oxide primer including all fixing arrangements complete including taking out old corroded unserviceable box complete all as directed. NOTE: Quoted rate shall be inclusive of fixing charges at break water signal lights through gemini/ boat. Transportation to be provided by Dept.
Supply and fixing LED Flood light fitting 470 Watts, High-quality integrated LED Flood light with a minimum system lumen of 56000 Lm (+/- 1%) and system wattage not exceeding 470 W with a nominal efficiency 120 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI: 70. The housing should be of non-corrosive high-pressure die-cast aluminum to withstand extreme environment. It should mandatorily have corrosion resistant powder coating to pass NSS of 500 hrs, with PF>0.95, Lifetime of 50K hours @ L70. Product should be suitable for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP 66 with a IK rating of 08. Optical and control gear compartments shall be maintainable/replaceable without impacting the LED units. The access to the optical and the gear compartment should be separate. While accessing the gear compartment, the optical compartment should not be accessible. The luminaire should have a 20KV /10KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e., Total 45 hits across all the three modes as per IEEE 62.41.2. The Luminaire should have a breather to ensure that air balance inside and outside of the Compartment. The luminaire should be of Class B Serviceability. The wattage of each LED should be greater than1 watt and less than 3 watt. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip, array multi die, mid power, integrated arrays and COBs are not permitted. The 140-144 Nos of high power LED used in the luminaire shall be SMD type. The luminaire should be capable of withstanding voltage stress of 440V for 8 hours, should have an auto shoutdown @ 325V and an have auto recovery feature. The driver should be a potted driver not a printed circuit board without casing, mounted inside the luminaire. The dimension of the luminaires should be minimum 595x100x418 mm and have a breather ensuring a stable optical and thermal management. The weight of the luminaire should not be more than 12 Kg. BIS certificate to be provided. MAKE : Philips Model : BVP485 LED560 CW NB PSU SPD GR or equivalent in Havells/ Osram/ Crompton Greaves as approved by GE.
Fixing only street lights/ flood lights/ garden lights/ gate lights/ high bay lights/ high mast lights or any other specified light in any height, any capacity, any area (Site 'A') complete all as specified and directed. NOTE: LED lights shall be issued under Sch 'B' free for fixing only.
ANKIT SHIP REPAIRERS AND SUPPLIERS
BROTECH
SRI GURUPRASAD INFRATECH
NAGESH BEERAPPA NAIK WORKS CONTRACTOR
M/S DK Enterprises
H S krishna Electricals
M/S VERNEKAR AGENCIES
DOGRA ELECTRICALS
Bidder Name
ANKIT SHIP REPAIRERS AND SUPPLIERS
M/S VERNEKAR AGENCIES
M/S DK Enterprises
SIRI SALES AND SERVICES
BROTECH
H S krishna Electricals
SRI GURUPRASAD INFRATECH
NAGESH BEERAPPA NAIK WORKS CONTRACTOR
DOGRA ELECTRICALS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .