| 1 | L1₹9.3 CrAccepted-AOC CHANDAN NAGAR OPP IOCL PERTROL PUMP RAMPUR ROAD BAREILLY UP 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | ₹9.3 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹9.7 Cr+₹40.2 L (4.34%)Rejected-Finance | ₹9.7 Cr+₹40.2 L (4.34%) | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹9.7 Cr+₹41.4 L (4.47%)Rejected-Finance | ₹9.7 Cr+₹41.4 L (4.47%) | L3 | Rejected-Finance Being other than L1 |
| 4 | L4₹10.6 Cr+₹1.3 Cr (14.5%)Rejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹10.6 Cr+₹1.3 Cr (14.5%) | L4 | Rejected-Finance Being other than L1 |
| 5 | L5₹10.9 Cr+₹1.6 Cr (17.4%)Rejected-Finance | ₹10.9 Cr+₹1.6 Cr (17.4%) | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹8.8 Cr
EMD Value
₹7.7 L
Closing Date
21 Mar 2025, 6:00 pmClosed
CHIEF ENGINEER LUCKNOW ZONE, LUCKNOW
HEADQUARTER CHIEF ENGINEER LUCKNOW ZONE, 17 CARRIAPPA MARG, POST-DILKUSHA, LUCKNOW CANTT-02
PROVN OF SINGLE LIVING ACCN FOR NCO/OR AT FATEHGARH CANTT
2025_MES_692801_1
CELZ/FAT/T-01 OF 2024-25
Open Tender
Civil Works
Lump-sum
750 days
AGE (I) FATEHGARH CANTT
PLEASE REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
AGE (I) FATEHGARH
₹7.7 L
13 Jun 2025
10 Jan 2025
28 Mar 2025
10 Jan 2025
21 Mar 2025
8 Mar 2025
Amount
Sch 'A' Part-I (Building Work) Note : This schedule is pre-priced by MES and the pre-priced rate indicated are under Col. 5.
Total amount of Sch 'A' Part II (Site clearance, Excavation and Earth work)
Total amount of Sch 'A' Part III (Internal Water Supply)
Total amount of Sch 'A' Part IV (Internal Electrification)
Total amount of Sch 'A' Part V (Road, Path and Hard Standing)
Total amount of Sch 'A' Part VI (Area Drainage)
Total amount of Sch 'A' Part VII (Sewage Disposal)
Total amount of Sch 'A' Part VIII (Security Wall, Fencing & Gate)
Total amount of Sch 'A' Part IX (External Water Supply)
Total amount of Sch 'A' Part X (External Electrification)
Total amount of Sch 'A' Part XI (Hot Water Supply)
Total amount of Sch 'A' Part XII (Dismantling/Demolition)
Total amount of Sch 'A' Part XIII (Rain Water Harvesting)
Sch 'A' Part - XIV(Miscellaneous Items for B/R and E/M wrok including Arboriculture) Note - This Schedule is not pre-priced by MES and the pre - priced rate indicated as "Rs 0.00 under col.5 siginifies this fact only.
INTERNAL WATER SUPPLY S&F for two way Angle cock/ angle valve, fancy type, chromium plated, ISI marked with crutch or butterfly handle, screwed down, screwed for iron pipe and fixed to 15mm bore pipe and fixed complete all as specified and as directed.
S&F for 3 in 1 , CP wall mixture for mixing hot and cold water with overhead shower arrangement screwed down for iron pipe and and fixed for 15mm bore pipe complete all as specified and as directed.
S&F for health faucet with 1.50 m long cord, chromium plated suitable for 15mm dia pipe including fixing of brackets complete all as specified and as directed.
INTERNAL ELECTRIFICATION M&L for point wiring complete for One light/Fan/Exhaust fan/Bell point controlled by one switch with PVC insulated and unsheathed FRLSH cable 1.5 sqmm (nominal area), ISI marked,multi stranded copper conductor cable including ISI marked not less than 20mm dia medium grade PVC conduit concealed in wall , heavy duty PVC conduit in roof/floors, factory made pressed steel concealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete,including 1.5 Sqmm PVC FRLSH cable insulated unsheathed multi stranded copper earth wire to the common earth and connecting to earth dolly,including colour coding of cable shall be Phase-red,Neutral-black and Earth- green with all accessories and complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for point wiring complete for One light point controlled by two 2-way switches with PVC insulated and unsheathed FRLSH cable 1.5 sqmm (nominal area), ISI marked,multi stranded copper conductor cable including ISI marked not less than 20mm dia medium grade PVC conduit concealed in wall , heavy duty PVC conduit in roof/floors, factory made pressed steel concealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete,including 1.5 Sqmm PVC FRLSH cable insulated unsheathed multi stranded copper earth wire to the common earth and connecting to earth dolly,including colour coding of cable shall be Phase-red,Neutral-black and Earth- green with all accessories and all as specified and directed.complete . Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for point wiring complete for One 5 pin 5 Amp switch socket out let point on an independent board with PVC insulated and unsheathed FRLSH cable 2.5 sqmm (nominal area), ISI marked,multi stranded copper conductor cable including ISI marked not less than 20mm dia medium grade PVC conduit concealed in wall , heavy duty PVC conduit in roof/floors, factory made pressed steel concealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete,including 2.5 Sqmm PVC FRLSH cable insulated unsheathed multi stranded copper earth wire to the common earth and connecting to earth dolly,including colour coding of cable shall be Phase-red,Neutral-black and Earth- green with all accessories complete for max four nos socket outlets all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for point wiring complete with PVC insulated and unsheathed, FRLSH cable 2.5 sqmm (nominal area), ISI marked, stranded copper conductor single core including ISI marked 20mm dia PVC conduit concealed in wall and heavy duty PVC conduit in roof/floor slab & ceiling, pressed GI concealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete, including 2.5 Sqmm FRLSH cable PVC insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all for max two nos socket outlets all as specified and directed. Note :- In case of roof/ceiling, heavy duty pipe shall be used without any extra cost.
S&F switch flush type 5/6 Amps single pole two way complete all as specified and dierected.
S&F LED batten Tube light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <20W (4 FT 20 W), luminaire lumen >2000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 45 centigrade, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification.complete all as specified and directed.
S&F LED Building security light fitting with aluminum pressure die cast housing, high purity PC Fresnel diffuser with silicon gasket for IP-65 protection, power consumption <25 W (25/30W) & luminaire lumen >2500 lm and system efficiency > 120 lm/W, in built electronic driver prewired upto terminal block with driver efficiency >85% power factor >0.95 as light source with toughened glass including two core flexible copper wire of 1.5 sq mm from ceiling rose to the connector of fitting, connection wires not to be more than 2.5 in length and made out of GI tubing 25/32 mm dia /suitable dia light grade bend to shape security light fitting with necessary MS clamp 25 mm wide and 6 mm in thickness in suitable length not more than 30 CM and max length of pipe 1.5 Mtr long with one code of anti corrosive primer and two coats aluminum paint including nuts, bolts and washers complete all as specified and directed.
Supply and fixing BLDC type Ceiling fan 1200 mm sweep five star rated single phase 230V AC, Min 220 CFM with fan remote , five star rating and ISI marked alongwith steel down rod and connecting up the fan to ceiling rose including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to ceiling fan motor not less than 0.5 mtr long for connection complete all as specified. Note:- Necessary Fan hook deemed to be included in item rate.
Supply and fixing Exhaust Fan high quality mettalic body, resistant to colour change 300 mm sweep five star rated, 900 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit pipe from celling rose to exhaust fan motor complete all as specified and directed.
S&F MCCB 4 pole 415 V AC 50 Hz fixed type 125 -160 amps with breaking capacity 16 KA complete all as specified and directed.
S&F MCB TPN 63 amp 4 P 415 V AC 50 Hz fixed type with breaking capacity 10 KA complete complete all as specified and directed.
S&F MCCB VTPN DB double door type, 415 Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCCB and with enclosure blank plates for unused way suitable for 4 way complete all as specified and directed.
S&F MCCB TPN DB double door type, 415 Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCCB and with enclosure blank plates for unused way suitable for 4 way complete all as specified and directed. .
Supply and fixing MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCB and with enclosure blank plates for unused way suitable for 12 way all as specified and directed .
S&F MCB SPN 32/40 Amps 'B" series,10 KA 240 Volts ,AC ISI marked all as specified and directed .
S&F MCB 6-32 Amps single pole,240V/415 V, 'B' Series, 50 Hz ,AC with breaking capacity 10 KA , complete all as specified and directed.
M&L submain wiring with two single core 6 sqmm FRLSH copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit concealed in wall surface / ceiling for sub main connection including one 6 sqmm FRLSH one single core PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified and directed. Note:- Two single core 6 sqmm copper conductor for phase / neutral, one run PVC conduit and one run of 6 sqmm earth wire shall be considered & measured as one unit.
M&L submain wiring with four single core 6 sqmm FRLSH copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit not less than 32mm dia medium grade concealed in wall surface / ceiling for sub main connection including one 6 sqmm single core FRLSH PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified and directed. Note:- four single core 6 sqmm copper conductor for phase / neutral, one run PVC conduit and one run of 6 sqmm earth wire shall be considered & measured as one unit.
M & L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground.(earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr. below ground level connecting to galvanised earth lead wire 4.0 mm dia as earth lead upto 7.5 meters long connected by means of bolts, check nuts and washers of GI and earth wire protected by provision of GI pipe medium grade, 15 mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 40 x 40 x 3mm fixing with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, with fixing arrangement, funnel, wire mesh and earth work in hard / dense soil, returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection all as specified and testing on completion. Note: The cost of excavation and earth work, PCC pit and pit covers, funnel and watering pipe, wire mesh, charcoal dust and common salt,20/ 40mm dia, medium grade, GI pipe as protection to GI wire 4.0 mm as main earthing lead from earth electrode to main TPN MCCBs DB/MCB DB/ test point length not less than 7.5mtrs) shall be deemed included in the unit rate for earthing and testing complete all as specified and directed .
Taking down old service connection/sub main wiring of any description of aluminium/copper conductor including batten/conduit/suspension wire etc and making good disturbed surface to match the existing surface.
Taking down old unservicable DB with MCBs/Main switches/MCB SP/SPN of any description and in any position.
Taking down old light fitting of any type and size complete all as directed
Taking down old point wiring of any description and any position complete all as directed
ROAD, PATH AND HARD STANING M&L for preparation of road surface and applying thermoplastic reflective paint for marking of minimum 1.5 mm thick single coat as a centre line or edge line etc, road marking of 150/100 mm width using “HOT MARK” thermoplastic paint (Hot application) white and yellow by indigenous modern propelled road marking machine as directed including all ingredients such as binder, glass beads, titanium dioxide, calcium carbonate, inter fillers etc, thermoplastic requirement for glass beads shall be conforming to BS-6086 of MOST specification including spraying of glass beads etc complete all as per manufacturer instructions and as directed.
AREA DRAINAGE M&L Precast M-25 grade epoxy coating factory made RCC 'U' shape drain block of size 450mm width and average depth 600mm as per site condition and wall thickness 80 mm including reinforcement as per manufacture instruction complete all as specified and directed.
M&L Precast factory made reinforced cement concrete cover slab of thickness 130 mm including reinforcement as per manufacture instruction complete all as specified and directed.
SEWAGE DISPOSAL Construction of RCC Septic tank designed for 100 users designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole opening with cover connection etc complete with effective depth of 1.5 m and overall depth of 3 m complete all as specified and directed.
Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.40 m dia x 3.00 m effective depth complete all as specified and directed.
Supply & laying 200 mm internal dia double walled corrugated pipe (DWC pipe) Class SN8 (Pipe with online/offline coupler and elastomeric sealing ring) with non-smooth external annular corrugated and smooth internal surfaces for non-pressure undergound Sewerage & Drainage application confirming to IS: 16098-2013 including all materials labours, T&P required for proper completion of work, laid and jointed etc complete all as specified and directed.
SECURITY WALL, FENCING AND GATE Supply and fixing concertina coil with 600 mm dia (wire 275 GSM & strip 200 GSM) tensile strength of wire 1400-150 N/Sqmm, weight 6-8 Kg/coil, stretchable length 6 m to 8 m including securing or tying at crossing with galvanized steel wire staples or steel pins etc complete all as specified and directed.
EXTERNAL WATER SUPPLY Cutting existing DI pipe line 150 mm dia for insertion of tee of size 150 x 150 x 100 mm for branch connection including excavation and earth work complete
Supply, laying and jointing of ductile iron pipes with spigot and socket ends suitable for push on rubber tightened joint centrifugally cast, class(K-7), Inner side cement lining and outer side metallic zinc/black bitumen coating and any length , laid in trenches of 100 mm bore pipe including push on rubber (EODM) ring with ISI marked including special complete all as specified and directed. Note : (i) Please note cost of rubber tightened joints to be included in the above quoted rate. (ii) Excavation and earth work shall be masured and paid under respective schedule
Supply and fix Sluice valve 100mm bore both ends flanged class PN 1.6 with stainless steel spindle and 01 No hand wheel including making new flanged joint with 3 mm thick rubber gasket (Packing ring) with necessary bolt, nuts and washer of suitable size necessary including testing complete all as specified and directed.
Construction of Sub-class 'B' brick masonry valve pit chamber of size 1200 mm X 1200 mm X 1200 mm (internal dimensions) including necessary excavation & earth work, 150cmx 150cmx100cm thick base for foundation with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, 230 mm thick brick work in cement mortar (1:6), 10 mm thick rendering in cement mortar (1:4) on internal & exposed surfaces including mild steel sheet cover of size 1m x 1m x 3mm thick and angle iron of size (40 x 40 x 5) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key (Make - Godrej or equivalent make as approved by GE complete) including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface including necessary earthwork & demolition of existing old valve pit complete all as specified and directed.
Construction of Sub-class 'B' brick masonry valve pit chamber of size 600 mm X 600 mm X 600 mm (internal dimensions) including necessary excavation & earth work, 750cm x 750cm x 100cm thick base for foundation with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, 230 mm thick brick work in cement mortar (1:6), 10 mm thick rendering in cement mortar (1:4) on internal & exposed surfaces including mild steel sheet cover of size 75cm x 75cm x 3 mm thick and angle iron of size (30 x 30 x 5) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key (Make - Godrej or equivalent make as approved by GE complete) including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface including necessary earthwork & demolition of existing old valve pit complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY : Supply installation, commissioning and testing of transformer ( Energy efficient, EEL-2, Level - 2 ) copper wound step down 200 KVA out door type 11/0.433 KV at no load 3 ph, 4 wire 50 HZ AC with oil immersed air naturally cooled (ONAN Type), with 1st filling of IS-335, external cooling tubes/radiators, Double wound core type copper wound having no load voltage ratio 11 KV/415 Volts corresponding to principal tapping, delta connected primary side (HV Side) and star connected on secondary side (LV Side) in accordance with vector symbol DYN 11 (Vector group-4) with neutral brought out on LV side and having tapping on HV side for constant out put so as to alter vary secondary voltage from ± 2 ½ %, ± 5% and ± 7 ½ % in step to be changed by mean of manual off load tap changing arrangements complete confirming to IS-1180 Pt-I 2014 with latest at the time of installation all as specified. The transformer shall be complete with following fittings and accessories:- (a) Oil conservator tank with filling hole and cap drain and oil level gauge. (b) Silica gel breather with oil seal and first fill of dehydrating agent. (c) Pressure relief valve with automatic resetting arrangement after release of pressure - 01 set. (d) Oil temperature gauge having range 0-120 C with max reading 100 mm dia with shut off valve between the conservator and main tank. (e) Adequate No of thermometer pocket including one number for accommodating bulb type thermometer. (f) Drain cum bottom valve.
(g) Top filter valve. (h) Prismatic oil level gauge. (j) Inspection cover. (k) Cover lifting lugs. (l) Jacking and lifting lugs. (m) Rating and diagram plate. (n) Separate neutral bushing brought out for earthing on LV side. (o) First filling of transformer oil confirming to IS-335-1972. (p) Earthing terminals -02 Nos located on diagonally opposite transformer tank base including lugs. (q) Transformer should have cable box on LT side and brass bushings on HT side.
Notes- (i) Drawing should be approved by GE before placing order. (ii) Transformer shall be platformed mounted as per TD drawing No TD-669 sheet 1/1 complete and rates quoted against this items shall be deemed to include for this provision. (iii) The contractor shall arrange factory visit as detailed by accepting officer to check the above system. (iv) Transformer should be 5 star rated and internal losses not more than 1% allowed.
Supply and erecting Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 of 11 mtr long, all as specified and shown on drawings including the followings:- (a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work complete. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work complete. (d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base. (e) Painting of poles externally with two coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block. (f) Painting of coping shall be cement base paint complete all as directed. (g) Embeded portion shall be painted with two coat of black bituminous paint complete all as specified and directed. Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately.
Supply and fix cable jointing kit for 1.1 KV grade cable for end termination joint indoor/outdoor type complete with jointing material heat shrink type and accessories suitable for 3.5/4 core XLPE armoured, aluminium conductor cable of size 70 to 95 sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for end termination joint indoor/outdoor type complete with jointing material heat shrink type and accessories suitable for 3.5/4 core XLPE armoured, aluminium conductor cable of size 240 sqmm complete all as specified and directed.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as directed.
M & L for DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof for outdoor installation and including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/6 sqmm 2 core and fixed to the PSC/Steel Poles by means of suitable size of clamps with nut and bolts with suitable busbar all as spcd and directed.
S & F pole mounted enclouser made of UV stabilized, FR grade special moulding compound having facility duriation base switching ON / OFF of capacity 5 KW, single phase, with suitable size of FI clamps 02 Nos with the following accessories and all as directed. (i) Contactor 40 amps. = 01 No. (ii) MCB 40 Amps(SP),10 KA ,240 volts. = 02 Nos (iii) NATURESWITCH-01
Supply and erecting Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 of 9 mtr long, all as specified and shown on drawings including the followings:- (a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work complete. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work complete. (d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base. (e) Painting of poles externally with two coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block. (f) Painting of coping shall be cement base paint complete all as directed. (g) Embeded portion shall be painted with two coat of black bituminous paint complete all as specified and directed. Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately.
M & L for cable route indicaor showing "MES HT U/G 11 KV " and route of cable with arrow (Embossed or engraved) made RCC in suitable shape and fixed in PCC block 1 : 3 :6 type C-2 using 40 mm gaded aggregate 60 cm X 30 cm in ground , 30 cm below ground level and 30 cm above ground level to show clear indication of cable including painting the complete slab wih red paint and marking the engraved/embosed letters/arrow with white paint complete all as directed. Note :- Quoted rate shall be deemed to included the cost of excavation, returning, filling and removal of excavated earth upto a distance of not exceeding 30 mtr complete.
Materials and labour for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel strip 32x6 mm as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 40 mm pipe medium grade for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore GI Pipe medium grade for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
M&L for preparation of new steel surface and applying two coat of aluminium paint over a coat of red oxide primer on HT pole, cross arms ,MS channel, angle iron frame work, bracing etc including numbering of poles with black paint complete all as directed.
Supply, installation, testing and commissioning of factory made powder coated (CPRI tested as per IS-8623) LT panel board cubical, outdoor type, degree of protection IP-51, weather, dust and vermin proof , cubical type made out of CRCA sheet 3 mm thick and doors and covers 2 mm thick, shrouds & partitions shall be of minimum 1.6mm thickness. with base frame of angle iron 50x50x6mm suitable for 415 volts, 3 phase,50 Hz, 4 wire system with front and rear side openable with double shutters, hinged and locking arrangement and slanted roof. The size of panel boards shall be suitable for housing the accessories given here under. The switch gears in the panel shall be such arranged so as to facilitate their maintenance and ease of inspection at the same time a adequate degree of safety.Minimum clearance of 25mm and 19mm respectively shall be maintained between phases/phase to neutral/phase to earth and between neutral to earth. When for some reason, these clearances are not available, suitable insulation shall be provided. All insulating materials used in the construction shall be non-hygroscopic type duly treated to withstand the effects of high humidity, high temperature tropical ambient service conditions. The switchgear panel shall be tested for the following- (a) Electrical and Mechanical operation test. (b) Insulation test at 2.5 KV for one minute. (c) Heat run test at rated current. (d) Megger test by 1000V megger The panel board shall comprise of following items with and including necessary connection complete all specified and directed.
WATER COOLER : Supply, installation, testing & commissioning of Water cooler fully Stainless steel (SS 304 grade), electric driven single phase 230 volt, BEE-5Star, 50 Hz having storage capacity 120 Ltrs & and nominal cooling capacity 60 Ltrs per hour, 100% copper cooling , as per latest version including connection by means of water pipe line, inlet and outlet, PVC pipe connection with brass coupling, nuts at both ends and other necessary fittings including necessary electric connection with and including plug top 15 Amps from voltage stabilizer to water cooler complete all as specified and directed.
DESERT COOLER : Supply and fixing of heavy duty desert cooler PVC body,3-side high efficiency honeycomb pads with dust filters for pure healthy air, powerful fan 15'' diameter with Robust weather resistant body for long life, Digital touchscreen & full function remote, Powerful 3 speed fan and empty water-tank alarm, Easily removable and cleanable cooling pads. Fully closable horizontal louvers, Float valve for auto water filling and lockable heavy-duty wheels, 4000 m³/hr air delivery low power consumption - 185 watts, storage capacity of tank should not be less than 50 litres and motor with thermal overload protection and including writing MES No. complete all as specified and directed. Note for WATER COOLER & DESERT COOLER Items:- (a) Minimum warranty 2 years on product, 10 years on compressor & 5 years condensor . (b) Item mfg date should not be older than 06 Months from installation date. (c) All items must have a permanent type vinyl sticker on outer body bearing following details and quoted rate are deemed to inclusive cost of sticker. (i) Machine Srl No._____________ (ii) MES No______________ (iii) Date set to work.____________ (iv) PRB Page No ______________. (v) Location__________________ (vi) CA No.________________________
HOT WATER : Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed.
RAIN WATER HARVESTING : M&L loose filling with pea gravel of size 1/18" to 3/18" to as in filter bed of approved quality complete all as specified and directed.
Drilling of hole in any kind of soil /strata by mechnical percussion or rotary ring method below GL including electric loging through any type of strata soil/rock disposal of soil within 10 mtr keeping space for pea gravel packing and including lowering and extraction of perforated PVC pipes of dia 200mm complete all as specified.
S&F Perforated PVC pipe 200mm dia in any length and fixed in any position including inverted earthen pots with holes on top complete all as specified.
ARBORICULTURE : Supply only compost manure incl loading, unlaoding & transportation & stacking at site complete all as directed . Note: (i) The compost shall be of uniform texture relatively dry of dark brown or black colour & should have an non offensive earth like odour. It shall be nutrient rich soil like material created by the biological decomposition of organic material such as vegetative debris & live stock manure. (ii) The net measurement of the compost manure shall be arrived at by reducing the actual stack measurements by 8% .
Supply only chemical fertilizer in bags complete all as specified and directed.
Supply only Urea / Ammonium Sulphate in bags complete all as specified and directed.
Supply only Bone Meal in bags complete all as specified and directed.
Supply only Potassium Sulphate or Murate of Potash in bags complete all as specified and directed.
Supply only insecticide/herbicide of approved make Chloropyriphos 35%EC or Monocrotophos 30% EC complete all as specified and directed.
Supply only of good earth (sand) from outside MD Land free from kankar, stones, cobbles,Moorum, shingle, Rocks building rubbish etc of all kinds & suitable foragricultuer/arboricultuer purpose, the 'Ph' of the soil brought shall be of the range 6 to 8.50 with net measurement of the compost manure shall be arrived at by reducing the actual stack measurements by 20% complete all as specified and directed. Note: Manure and chemical shall be measured and paid separately.
Supply & planting of Amaltas ( Cassia Fistula) height of sapling 1.20 to 1.50 m trees at desired distances in rows or other patterns to provide a green cover to the area in the following stages. Note:- (i) Excavating pits of size 75 cm dia & depth 75-80 cm taking out the soil & keeping aside . (ii) Removing the stones, cobbles, boulders, vegetation etc from the excavated soil & mixing the balance excavated earth with a mixture of good earth & compost manure mixed @ 4:1 & filling the mixture so obtained in layers in the excavated post hole aroud the sapling together with watering & supporting the plant/tree sapling with a bamboo /wooden stake & tieing with two ties all as directed. (iii) Manure and chemical shall be measured and paid separately.
Ditto all as per srl No.14.67 here -in-before but Gulmohar ( Delonix Regia) Ht of Sapling 1.20 to 1.50 m complete all as specified and directed.
Ditto all as per srl No.14.67 here -in-before but Neeli Gulmohar (Jacaranda Mimasifolia) height of Sapling 1.20 to 1.50 m complete all as specified and directed.
Ditto all as per srl No.14.67 here -in-before but Ashoka Tree ( polyalthai longifolia ) height of Sapling 1.20 to 1.50 m complete all as specified and directed.
Ditto all as per srl No.14.67 here -in-before but Neem tree (Azadirachta Indica) height of sapling 1.20 to 1.50 m complete all as specified and directed.
Ditto all as per srl No.14.67 here -in-before but Ficus benzamin height of sapling 1.20 to 1.50 m complete all as specified and directed.
Ditto all as per srl No.14.67 here -in-before but Bottle Palm tree ( height 2.00 m when planted) complete all as specified and directed.
Ditto all as per srl No.14.67 here -in-before but Mango tree (height 2.00 m when planted) complete all as specified and directed.
Supply and landscaping of natural turfgrass (Green mexican lawn grass/natural nilgiri grass) in lawn area and described arboriculture portions complete all as specified and directed.
S&F tree guards 1.50m high fabricated with 40 mm thick RCC precast Jali with intricates designs & jointed using wire & cement mortar all as directed at site incl two coats of syn enamel paint all as specified & directed at site together with necessary excavation & earthwork for fixing /errection complete all as specified and directed.
BD AGARWAL BUILDTECH INDIA PRIVATE LIMITED (BID ID -3267935)
S. K. CONSTRUCTION (BID ID -3261790)
YAUK ENGINEERS (BID ID -3263153)
MD BUILDER (BID ID -3259402)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .