Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.2 LAccepted-Finance | ₹37.2 L | L1 | Accepted-Finance Being lowest |
| 2 | L2₹37.9 LRejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | ₹37.9 L | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹40.4 LRejected-Finance CB 1 MAHAVEER NAGAR BARMER 344001 RAJ | BARMER | RAJASTHAN | 344001 | ₹40.4 L | L3 | Rejected-Finance Not being lowest |
| Sl No | Description | Qty | Unit | HIMANSHI ENTERPRISES L1 | M/s Rohit Construction Co. L2 | M/S PRASHANT BENIWAL L3 |
|---|---|---|---|---|---|---|
| 1.00 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge. | 108 | Cum | 650 ₹70,200 | 500 ₹54,000 | 800 ₹86,400 |
| 2.00 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/ disintegrated rock all as specified & directed by Engineer-in-Charge. | 96 | Cum | 50 ₹4,800 | 30 ₹2,880 | 50 ₹4,800 |
| 3.00 | Removing excavated soft/ disintegrated rock to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by the Engineer-in-Charge. | 12 | Cum | 50 ₹600 | 30 ₹360 | 150 ₹1,800 |
| 4.00 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in soft/loose soil complete all as specified & directed by Engineer-in-Charge. | 134 | Cum | 250 ₹33,500 | 300 ₹40,200 | 300 ₹40,200 |
| 5.00 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick soil complete all as specified & directed by Engineer-in-Charge. | 116 | Cum | 50 ₹5,800 | 20 ₹2,320 | 50 ₹5,800 |
| 6.00 | Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-Charge. | 18 | Cum | 50 ₹900 | 20 ₹360 | 50 ₹900 |
| 7.00 | Taking down defective/unservicable solar street light/ Flood light/solar PV panel ,any type of battery ,GI brackets, fitting of any size /type/capacity any Watt from height of pole for repair work and fixing back after repair work including checking, inspecting, testing and commissioning complete all as specified.
Note :- (a) Spares like drivers,battery ,PIR motion sensor , LED Driver,surge protector,light, etc. shall be measured and paid as separetely under relavant items of schedule'A'
(b) Necessary tools like mobile ladder & other T&P required etc shall be arranged by the contractor without any extra cost.
(c) The rate quoted deemed to be inclusive for minor repair parts like nuts, bolts, cirle clips , clamps etc required if any at site. | 530 | Each Job | 90 ₹47,700 | 200 ₹1.1 L | 100 ₹53,000 |
| 8.00 | Supply and fix in repair of electronic driver for LED flood light fitting, LED out put power 100 watt, input voltage range : 170 - 300 volt AC , out put voltage DC as per make/ model range: 24 volt to 110 volt, make as per site requirement complete all as specified. | 20 | Each | 700 ₹14,000 | 700 ₹14,000 | 500 ₹10,000 |
| 9.00 | All as per item No 8 above but capacity 150 watt | 15 | Each | 900 ₹13,500 | 1,000 ₹15,000 | 1,000 ₹15,000 |
| 10.00 | All as per item No 8 above but capacity 200 watt | 20 | Each | 1,350 ₹27,000 | 1,200 ₹24,000 | 1,500 ₹30,000 |
Updated dates
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
27 Feb 2026, 6:00 pmClosed
GE Army Jaisalmer
GE Army Jaisalmer - 345001
REPAIR AND MAINT OF SOLAR STREET LIGHT AND HIGH MAST LIGHT UNDER GE ARMY JAISALMER AT MIL STN JAISALMER
2026_MES_750675_1
8559/25-26/E8
Open Tender
Electrical and Maintenance Works
180 days
Jaisalmer
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Army Jaisalmer
₹80,000
Yes
30 Mar 2026
30 Jan 2026
2 Mar 2026
30 Jan 2026
27 Feb 2026
13 Feb 2026
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/ disintegrated rock all as specified & directed by Engineer-in-Charge.
Removing excavated soft/ disintegrated rock to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by the Engineer-in-Charge.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in soft/loose soil complete all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick soil complete all as specified & directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-Charge.
Taking down defective/unservicable solar street light/ Flood light/solar PV panel ,any type of battery ,GI brackets, fitting of any size /type/capacity any Watt from height of pole for repair work and fixing back after repair work including checking, inspecting, testing and commissioning complete all as specified. Note :- (a) Spares like drivers,battery ,PIR motion sensor , LED Driver,surge protector,light, etc. shall be measured and paid as separetely under relavant items of schedule'A' (b) Necessary tools like mobile ladder & other T&P required etc shall be arranged by the contractor without any extra cost. (c) The rate quoted deemed to be inclusive for minor repair parts like nuts, bolts, cirle clips , clamps etc required if any at site.
Supply and fix in repair of electronic driver for LED flood light fitting, LED out put power 100 watt, input voltage range : 170 - 300 volt AC , out put voltage DC as per make/ model range: 24 volt to 110 volt, make as per site requirement complete all as specified.
All as per item No 8 above but capacity 150 watt
All as per item No 8 above but capacity 200 watt
All as per item No 8 above but capacity 250 watt
Supply and fix in repair Surge Protector 10KV for street light fitting, Normal voltage input range : 170- 300 volt complete all as specified.
Supply & Fixing in repair Led Flood Light Fitting 150 Watt Elegently Designed, Pressure Die Cast Aluminium Housing In Powder Coated Finish Ip-66, Lumen Efficacy >= 120lm/W And Total Lumens Output Must Be = 30,000 Lumens Or More, Operating Voltage Range 120 – 270, P.F > 0.95,Cct – 5700k, Surge Protector Of 10 Kv Inside Fitting, Driver Of The Fitting Shall Be Potted Type Only For Vibration Proof Performance With Inbuilt Surge Protector, Over Voltage Protection. Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver.Including Disconnected & Taking Down Old Unserviceable Light Complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. Including Making Connection With 3 Core X 1.5 Sqmm Frlsh Wire, All As Per Directed By Eic As all as specified and directed by Engr-in-Charge Per Make – Crompton/Havells/Bajaj Crompton Cat no TFS-507-150-57-60 D-SL-GL-NSG Bajaj Cat no:- JENXT P180L WH PO TG SD Orient Cat no:-Orient cat no:LFSM-150-C-V3 or equivalent in Appx 'C' list of makes.
Supply & Fixing in repair Led Flood Light Fitting 200 Watt Elegently Designed, Pressure Die Cast Aluminium Housing In Powder Coated Finish Ip-66, Lumen Efficacy >= 120lm/W And Total Lumens Output Must Be = 30,000 Lumens Or More, Operating Voltage Range 120 – 270, P.F > 0.95,Cct – 5700k, Surge Protector Of 10 Kv Inside Fitting, Driver Of The Fitting Shall Be Potted Type Only For Vibration Proof Performance With Inbuilt Surge Protector, Over Voltage Protection. Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver.Including Disconnected & Taking Down Old Unserviceable Light Complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. Including Making Connection With 3 Core X 1.5 Sqmm Frlsh Wire, All As Per Directed By Eic As all as specified and directed by Engr-in-Charge Per Make – Crompton/Havells/Orient Crompton Cat no TFS-507-200--57-60 D-SL-GL-NSG havells Cat no:- JETAIRIMAXFL200WLED757PWBLTG Orient Cat no:- :LFSM-200-C-V3 or equivalent in Appx 'C' list of makes.
Supply & Fixing in repair Led Flood Light Fitting 250 Watt Elegently Designed, Pressure Die Cast Aluminium Housing In Powder Coated Finish Ip-66, Lumen Efficacy >= 120lm/W And Total Lumens Output Must Be = 30,000 Lumens Or More, Operating Voltage Range 120 – 270, P.F > 0.95,Cct – 5700k, Surge Protector Of 10 Kv Inside Fitting, Driver Of The Fitting Shall Be Potted Type Only For Vibration Proof Performance With Inbuilt Surge Protector, Over Voltage Protection. Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver.Including Disconnected & Taking Down Old Unserviceable Light Complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. Including Making Connection With 3 Core X 1.5 Sqmm Frlsh Wire, All As Per Directed By Eic As all as specified and directed by Engr-in-Charge Per Make Crompton/Havells/Bajaj – Crompton Cat noCFS-506-250-57-30D-HL2-GL-NSG,Havells Cat No :-JETAIRIMAXFL250WLED757PWBLTG , Orient cat no:LFSM-250-C-V3 or equivalent in Appx 'C' list of makes.
Supply & Fixing in repair Led Flood Light Fitting 400 Watt Elegently Designed, Pressure Die Cast Aluminium Housing In Powder Coated Finish Ip-66, Lumen Efficacy >= 120lm/W And Total Lumens Output Must Be = 48,000 Lumens Or More, Operating Voltage Range 120 – 270, P.F > 0.95, , Cct – 5700k, Of Surge Protector Of 10 Kv Inside Fitting, Driver Of The Fitting Shall Be Potted Type Only For Vibration Proof Performance With Inbuilt Surge Protector, Over Voltage Protection. Both Fixture And Drivre Must Have Seperate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver.Including Disconnected & Taking Down Old Unserviceable Light Complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. Including Making Connection With 3 Core X 1.5 Sqmm Frlsh Wire, All As Per Directed By Eic all as specified and directed by Engr-in-Charge Per Make Crompton/Havells/orient– Cat no CFS-512-400-57-30D-SL-GL-NSG ,havells Cat No:- JETAVALOURLEFL400W3MLED757PINTNBLTG Orient cat no:LFSMU-400-C or equivalent in Appx 'C' list of makes.
Supply & Installation in repair of Mono crystalline Solar PV Panel of 12V 135Wp (Suitable for 30 Watt solar light) with wires and connectors to fit in existing system,complete all as specified & directed by Engr-in-Charge.
Supply & Installation in repair of Mono crystalline Solar PV Panel of 12V 80Wp (Suitable for 9 to 12 Watt solar light) with wires and connectors to fit in existing system,complete all as specified & directed by Engr-in-Charge.
S & F in repair/replacement of PVC insulated, sheathed weather proof, copper conductor of size 2.5 sqmm, 2 core complete all as specified.
Supply & Installation in repair of 12 watt LED street light Luminary for solar light with inbuilt charge controller, High brightness W-LED(120-180lm/watt) lamp with proper optics lens for better light distribution , CRI >70, Color Temperature 6500K, Microcontroller based charge controller cum driver, automatic dimming function, Dusk to Down Operation, Protections: Short Circuit, overload, Reverse polarity and battery protections. With Vital Parameters Test report from NABL accredited lab and should be of made in India with CE & ROHS, IP66 and IK08 Compliant. complete all as specified & directed by Engr-in-Charge.
Supply & Installation in repair of 30 watt LED street light Luminary for solar light with inbuilt charge controller, High brightness W-LED(120-180lm/watt) lamp with proper optics lens for better light distribution , CRI >70, Color Temperature 6500K, Microcontroller based charge controller cum driver, automatic dimming function, Dusk to Down Operation, Protections: Short Circuit, overload, Reverse polarity and battery protections. With Vital Parameters Test report from NABL accredited lab and should be of made in India with CE & ROHS, IP66 and IK08 Compliant. complete all as specified & directed by Engr-in-Charge.
Supply & Installation in repair of Maintenance free lead Acid VRLA type Battery 12V 80 Ah (Suitable for solar street light,warrenty minimum 24 month of battery) with other necessary wires and connectors suitable for existing system.complete all as specified & directed by Engr-in-Charge. make Exide,amron,luminious
Supply & Installation in repair of Maintenance free lead Acid VRLA( maintance free battery type Battery 12V 40 Ah with charge controller (Suitable for solar street light warrenty up to 36 month of battery) with other necessary wires and connectors suitable for existing system.complete all as specified & directed by Engr-in-Charge.
Supply & fix in repair of Solar Charge Controller for inbuilt solar street light all in one MPPT 10 Amp with protection circuit Solar street Light System: 12V Nom inal Capacity: 80Wp Max Regulation: Low Loss, Shunt Type OVD: Output Voltage Dropcomplete all as specified & directed by Engr-in-Charge.
Supply and fix in repair of of PIR Motion Sensor 170uA for Solar street Light all in one Standard Detection 5m Lens Color : White complete all as specified and directed by Engr -in- Charge
Supply & fix in repair & Installation of Lithium Battery 12.8V/ 42 Ah (Suitable for 16 to 40 Watt solar light) with BMS Circuit and other necessary wires and connectors suitable for 16 to 40 watt Integrated all in one Solar Lights complete all as specified and directed by Engr -in- Charge.
Supply & fix , Installation,in repair of Lithium Battery 12.8V/ 36Ah (Suitable for 12 to 16Watt solar light) with BMS Circuit and other necessary wires and connectors all as specified & directed by Engr-in-Charge.
Supply & fixing in reapir of Rocker Switch 6 to 10Amp for solar lights complete all as specified and directed by Engr -in- Charge.
S&F in repair solar street light of 20 watt all in one FRP/Aluminium extruded Lithium based energy efficient Integrated with polyurethane coating camouflag colour servicable battery compartment, solar PV panel of 35-40 WP mono crystalline,, Lithium battery 12.8 Volt, 18-24 Ah LiFeP04 , Min Lux level >3000 Lumens ,MPPT Charger with inbuit BMS Technology ,PIR motion sensor system at 30% start dimming brightness glow to 100% for 30 second upon motion detection High brightness luminous efficiency W-LED (135-180 Im/Watt),life span of of LED >50,000 Hrs , protection lamp with aluminium reflector for better lighting distribution, CRI > 70, colour temperature 5700 ANSI, Microcontroller based charge controller cum driver in built DC type, automatic fix motion dimming function with PIR motion sensor,Dusk to dawn operation, ,working temp : (-10 C ) to (+) 55 C ,humidity range 0-95%, with adjustable MS Clamp suitable for existing pole/wall mounting ,low votage indication ,charging indication ,with bty over charge protcetion ,Bty deep discharge protection ,No load/Open load protection etc complete all as specified and directed by Engr-in-Charge. Make :- Crompton cat no-CSOP-814-20-57-HL5-FD-LM-SR or equivalent in Appx 'C' list of makes. Note : Short Circuit, overload, reverse polarity and battery protections to be provided. OEM should provide vital parameters test report from NABL accredited lab and should be of made in India with CE & ROHS , IP65/ 66 and IKO8 complaint
S&F in repair solar street light of 30 watt all in one FRP/Aluminium extruded Lithium based energy efficient Integrated with polyurethane coating camouflag colour servicable battery compartment, solar PV panel of 48-60 WP mono crystalline,, Lithium battery 12.8 Volt, 24-30 Ah LiFeP04,Min lux level >4500 lumens ,MPPT Charger with inbuit BMS Technology ,PIR motion sensor system at 30% start dimming brightness glow to 100% for 30 second upon motion detection High brightness luminous efficiency W-LED (150-180 Im/Watt),life span of of LED >50,000 Hrs , protection lamp with aluminium reflector for better lighting distribution, CRI > 70, colour temperature 5700 ANSI, Microcontroller based charge controller cum driver in built DC type, automatic dimming function ( first four hours at full brightness & rest of the time at lower light level with PIR motion sensor,Dusk to dawn operation,and ,working temp : (-10 C ) to (+) 55 C ,humidity range 0-95%, weight 15-20 KG with adjustable MS Clamp suitable for existing pole/wall mounting ,low votage indication ,charging indication ,with bty over charge protcetion ,Bty deep discharge protection ,No load/Open load protection etc complete all as specified and directed by Engr-in-Charge. Make :-Crompton cat no-CSOP-815-30-57-HL5-PIR-LM-SR or equivalent in Appx 'C' list of makes. Note : Short Circuit, overload, reverse polarity and battery protections to be provided. OEM should provide vital parameters test report from NABL accredited lab and should be of made in India with CE & ROHS , IP 66 and IKO8 complaint.
S&F in repair solar street light of 40 watt all in oneFRP/ Aluminium extruded Lithium based energy efficient Integrated with polyurethane coating camouflag colour servicable battery compartment, solar PV panel of 48-60 WP mono crystalline,, Lithium battery 12.8 Volt, 24-30 Ah LiFeP04,Min lux level >4500 lumens ,MPPT Charger with inbuit BMS Technology ,PIR motion sensor system at 30% start dimming brightness glow to 100% for 30 second upon motion detection High brightness luminous efficiency W-LED (150-180 Im/Watt),life span of of LED >50,000 Hrs , protection lamp with aluminium reflector for better lighting distribution, CRI > 70, colour temperature 5700 ANSI, Microcontroller based charge controller cum driver in built DC type, automatic dimming function ( first four hours at full brightness & rest of the time at lower light level with PIR motion sensor,Dusk to dawn operation,and ,working temp : (-10 C ) to (+) 55 C ,humidity range 0-95%, weight 15-20 KG with adjustable MS Clamp suitable for existing pole/wall mounting ,low votage indication ,charging indication ,with bty over charge protcetion ,Bty deep discharge protection ,No load/Open load protection etc complete all as specified and directed by Engr-in-Charge. Make :-Crompton cat no-CSOP-815-30-57-HL5-PIR-LM-SR or equivalent in Appx 'C' list of makes. Note : Short Circuit, overload, reverse polarity and battery protections to be provided. OEM should provide vital parameters test report from NABL accredited lab and should be of made in India with CE & ROHS , IP 66 and IKO8 complaint.
Supply and fixing in replacement of copper wire 2.5 Sqmm 6 core suitable for high mast light all as specfied and directed by Engineer -in -charge
Taking down by disconnected the existing electrical connection of winch motor for rewinding /repairs including rewinding the mortor of capacity up to 2 HP with best class supper enameled copper wire of existing guage and size including varnishes and insulating 230 V AC 50 HZ electric supply system . refixing and reconnected it to the original location for satisfactory functioning of wintch on 230 v electric supply system all as specfied ,
Supply & fix MNX Power contactor suitable for power supply 40 Amps 4 pole 4 NO Contactor including making electrical connection to the contactor complete all as specified & directed by Engr-in-Charge. Make: Legrand or equivalent make of Havells/L&T.
Supply & fix MNX Power contactor suitable for power supply 63 Amps 4 NO Contactor including making electrical connection to the contactor complete all as specified & directed by Engr-in-Charge. Make: Legrand or equivalent make of Havells/L&T.
S&F in repair Digital Astronomical timer switch 240V AC-2W,C/O, Base/DIN type complete for switching of contactors complete all as specified and directed by Engineer-in-charge.
S&F Nature switch( using infrared sensor technology ) based automatic street light control panel. The panel should be enough to take three phase load of 3-5 kw.Nature switch operation should be based on natural light luxes. required illuminance level switching ON is <=60 and for Switching OFF >=10 lux. the senser should be have a part night operation facility of min 4HRS to max 12 hrs . the senser along with suitable 3 phase load of 3-5 KW with 3 nos contractor ,3 nos Incoming MCBs of 63 Amps and outgoing MCBs of 40 Amp and circuit wire copper of min 16 Sqmm and should be enclosed in a pole /wall mountig Rust proof ,Electric shock proof ,Termite proof and FR grade thermoplastic polycarbonate enclouser (with hinged lid) conforming to IP66 protection.The circuit should also have provision gor Manual or Auto operation . complete all as specified and directed by Engr-in-Charge.
Supply & fix in repair MCB, SPN, 32 Amp, 240 Volts, 'C' Curve 10KA including dismantling old one Complete all as specifed and directed by Eng-in-Charge.
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning. TPN 40 to 100 Amp including taking down and dismentaling old one Complete all as specifed and directed by Engr-in-Charge.
Supply & fix in repair MCCB 415V, 3 phase 50 HZ 4 pole 63 Amps breaking capacity 16 KA (Ics = 100% Icu) with including dismantling old one connection link on LT panel /fedder piller Complete all as specifed and directed by Eng-in-Charge
Supply ,laying, test and commissioning in repair of LT UG ,XLPE insulated, heavy duty, 1100V grade of electric cable size 16 Sqmm 4 core with aluminium conductor ,served with an inner sheathing of PVC tape armoured eith galvanized steel wire or tape and overall PVC sheathed,laid in trench or passing through pipe, making all connection with and including provision of necessary glands ,lugs,bushing etc as required complete all as specified and directed by Engineer-in -Charge of following size:- Note: Earthwork excavation sand cushioning ,Jodhpur stone patti, GI protcetion pipe shall be measured and paid separately in their respective items.
All as above item no 42 but size 25 Sqmm 4 core
All as above item no 42 but size 35 Sqmm 3.5 core
Supply and laying DOUBLE WALL CORRUGATED (DWC) pipe 40 mm outer dIa 32 mm bore as per is 16205 part 24 cable protectionincluding all fitting as required complete all as specified and directed by engineer- in-charge.
Supply and laying DOUBLE WALL CORRUGATED (DWC) pipe 50 mm outer dIa 38 mm bore as per is 16205 part 24 cable protectionincluding all fitting as required complete all as specified and directed by engineer- in-charge.
S&F In rtepair of GI Pipe of 80 mm in single length (20 ft /06 mtr )for solar street light complete all as specified & directed by Engr-in-Charge.
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate in foundation for PCC poles/struts including necessary form work complete all as specified & directed by Engr-in-Charge.
M & L for plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation of stay assembly including necessary form work all as specified and directed by Engr-in-Charge.
M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) for pedestal/coping/plinth of poles, including necessary form work finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
Supply & fix in repair 40 mm bore GI tubing medium grade in trenches or on pole for cable protection complete all as specified and as directed.
Supply & fix in repair 50 mm bore GI tubing medium grade in trenches or on pole for cable protection complete all as specified and as directed.
M&L for Cutting the road / hard standings and excavating in trenches not exceding 0.40 mtr wide and not exc 0.80 mtr deep across the road for laying cable including making good the excavated portion by means of PCC 1:2:4, type B1 using 20mm graded stone aggregate complete and matching with the surroundings complete all as specified.
Supply and, fixing fabricate structural mild steel RS joist , channel angle iron, flat iron and brackets etc for fabrication of cross arms, bracing supports clamps including D clamps, eye hook and back plate etc fabricated from structural steel section including nuts , bolts, washers, welding (cold and hot ) drilling holes for bolts, bend to any shape or size as indicated and directed, inclusive of one primer coat and two coats of aluminium paint after preparation of surfaces complete all as specified and directed by Engineer-in-charge.
Note No.1 : (a) Contractor has to arrange his own vehicles along with mounted hydraulic ladder/articulated & telescopic boom lift arrangement for attending the complaint throughout jaisalmer cantt area. (b) Contractor shall depute minimum 2 staff daily to attend and rectify the complaint within minimum time, if not, Contractor shall have to bear a penalty of Rs 50.00 per complaint or maximum of Rs 500 per day on this account (c) Complaints has to attend and rectify the complaint/defect irrespective of no of trips/Complaints as alloted by Eng-in-Charge.(d) Complaint should be attend in Night also Note No.2 : Contractor has to arrange telescopic boom lift for maintenance at height of 15m at his own cost. No extra payment will be paid by department.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
BOQ_840750.xls
BOQ • 3.98 MB
Tenderdocuments8559.pdf
Tender Documents • 0.93 MB
Download all tender documents and submit your bid