Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical 4005 4TH FLOOR SKYLINE NEAR KADRU OVERBRIDGE KADRU RANCHI PIN 834008 | RANCHI | RANCHI | JHARKHAND | 834008 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical 00 C O LAKHAN LAL AGRAWAL RATU ROAD NEAR KABLISTHAN RANCHI JHARKHAND 834001 | RANCHI | JHARKHAND | 834001 | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical AT PO DAKRA KHALARI DIST RANCHI JHARKHAND PIN 829210 | RANCHI | JHARKHAND | 829210 | Admitted-Fee/PreQual/Technical |
| 5 | Admitted-Fee/PreQual/Technical HOUSE NO 345 SHREE RAM ELECTRICALS SONIPAT ROAD LAWANSPUR SONIPAT HARYANA 131021 | SONIPAT | HARYANA | 131021 | Admitted-Fee/PreQual/Technical |
Tender Value
₹9.2 L
EMD Value
₹11,500
Closing Date
17 Mar 2026, 5:00 pmClosed
SO EnM NK
GM OFFICE, NK AREA
Making new power arrangement to supply power to Air Conditioners and new equipment installed at different locations under GM Unit, NK Area
2026_CCL_355778_1
GM (NK)/EnM/e-NIT/2025-26/ 137
Open Tender
Electrical and Maintenance Works
Item Rate
14 days
GM Unit, NK Area
As per NIT
2 documents required · 2 mandatory
₹11,500
17 Jun 2026
6 Mar 2026
18 Mar 2026
7 Mar 2026
17 Mar 2026
7 Mar 2026
7 Mar 2026 - 13 Mar 2026
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 x 10 sq mm + 2 x 6 sq mm earth wire.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 x 6 sq mm + 1 x 6 sq mm earth wire.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire.
Supplying, installing, testing and commissioning of following capacity TPN tap off box / plug-in box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing overhead bus bar system complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required. 100 A
Supply and installation of 100 A Bus Bar
Total impact of GST for the purpose of CTC
stage.html
html • 0.03 MB
cancelled_1.pdf
pdf • 0.30 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 2.54 MB
BOQ_368625.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .