| 1 | L1₹64.1 LAccepted-AOC NO 1C CHROMPET KANCHIPURAM TAMIL NADU 600044 INDIA | CHENGALPATTU | TAMIL NADU | 600044 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹71.2 L+₹3.7 L (5.47%)Rejected-Finance 25 A BR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | L2 | Rejected-Finance Being other than lowest tenderer | |
| 3 | Rejected-Technical 64 INDUSTRIAL ESTATE PERUNGUDI CHENNAI TAMIL NADU 600096 | CHENNAI | TAMIL NADU | 600096 | - | Rejected-Technical Not meeting eligilibity criteria. Shortfall documents not submitted as per NIT and asked vide this office letter No 86501/07/E8 dt 22 Jan 2022. | |
| 4 | Rejected-Technical 27 1ST STREET PERIYAR NAGAR 1ST STREET PERIYAR NAGAR ADAMBAKKAM KANCHIPURAM TAMIL NADU 600088 | CHENNAI | TAMIL NADU | 600088 | - | Rejected-Technical Not meeting eligibility criteria. Residual work load in hand exceeds the ceiling limit. | |
| 5 | Rejected-Technical | - | Rejected-Technical Not meeting eligility criteria. Shortfall documents not yet submitted/uploaded. |
Tender Value
₹69.5 L
EMD Value
₹1.3 L
Closing Date
1 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri. Narinder Singh, IDSE, SE(SAG)
COMMANDER WORKS ENGINEERS CHENNAI PALLAVAN SALAI CHENNAI 600 002
SPECIAL REPARS REPLACEMENT OF HT LT CABLES AND CONNECTED WORKS UNER GE STM CHENNAI
2021_MES_491142_1
86501/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE STM chennai
As per NIT
8 documents required · 8 mandatory
₹1,000
₹1.3 L
Yes
9 Mar 2022
29 Nov 2021
8 Jan 2022
29 Nov 2021
1 Jan 2022
20 Dec 2021
29 Nov 2021 - 10 Dec 2021
60 days
Amount
BOQ UPLOADED ON 29 NOV 2021
SCH "A" PART-I (E/M ITEMS)
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc not exceeding 10 sqm on plan and not exceeding 1.5m depth and getting out in any type of soil all as specified and as directed.
Removing excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and as directed.
Fine seived excavated dry soil laid to the required width of trench at bottom and top of cable as cushioning all as specified and as directed.
(i) Punned thickness only shall be measured. (ii) The soil used shall be free from sharp grains and deletrious materials like dry/decayed plants etc.,
Common burnt bricks sub class "B" of old size, designation 50, laid dry in trenches with width equal to length of bricks across the cable for cable protection all as specified and as directed.
Reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mmx l80mm x 40mm all as specified and as directed.
Taking out existing cable any type / cross section and Supply, laying, connecting and testing HT UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 11000 volts grade, (Earthed), 3 core, cross sectional area 95 sqmm in bridges / culvert / trenches / drawn through pipe / fixed on walls / bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipments complete all as specified and as directed.
Taking out existing cable any type / cross section and Supply, laying, connecting and testing HT UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 11000 volts grade, (Earthed), 3 core, cross sectional area 120 sqmm in bridges / culvert / trenches / drawn through pipe / fixed on walls / bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipments complete all as specified and as directed.
Taking out existing cable any type / cross section and Supply, laying, connecting and testing HT UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 11000 volts grade, (Earthed), 3 core, cross sectional area 185 sqmm in bridges / culvert / trenches / drawn through pipe / fixed on walls / bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipments complete all as specified and as directed.
Note for item No 8.00 to 10.00:-
(a) Lugs and glands shall be used appropriately wherever required while connecting cables to the panel board and the quoted rates are deemed be include for the same.
(b) Earthwork, sand cushioning, protection for cable etc., as required shall be measured and paid separately.
Dismantling of ACSR conductors complete all as specified and as directed.
Dismantling of cradle guard/ GI wire complete all as specified and as directed.
Dismantling of cross arms, bracing supports etc complete all as specified and as directed.
Dismantling of insulators any type any size complete all as specified and as directed.
Plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as in coping of poles and similar work complete all as specified and as directed.
Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundation of poles, stay assembly complete all as specified and as directed.
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and as directed.
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and as directed.
Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and as directed.
Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120sqmm to 185 sqmm complete all as specified and as directed.
Steel tubing, galvanised, light grade, with necessary fittings such as bends, elbows, tees etc., and laid in bridges / culvert / trenches / under roads / crossings etc., of bore of pipe 100mm for cable protection complete all as specified and as directed.
Steel tubing, galvanised, light grade, with necessary fittings such as bends, elbows, tees etc., and laid in bridges / culvert / trenches / under roads / crossings etc., of bore of pipe 80mm for cable protection complete all as specified and as directed.
Steel tubing, galvanised, light grade, with necessary fittings such as bends, elbows, tees etc., and laid in bridges / culvert / trenches / under roads / crossings etc., of bore of pipe 40mm for cable protection complete all as specified and as directed.
Earthwork as required shall be measured and paid separately.
Supply and fix/erect/ground cable route indicator marked with HT/LT cable made out of GI plate 3mm thick and 150mm dia duly marked with working voltage, size of cable and fixed with angle iron of size 25x25x3mm thick 500mm long embedded in PCC 1:2:4 type B1 of size 300 x 300 x 300mm in ground complete all as specified and as directed.
Supply, laying, connecting and testing LT UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts grade, 4 core, cross sectional area 16 sqmm in bridges / culvert / trenches / drawn through pipe / fixed on walls / bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipments complete all as specified and as directed.
Supply, laying, connecting and testing LT UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts grade, 4 core, cross sectional area 25 sqmm in bridges / culvert / trenches / drawn through pipe / fixed on walls / bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipments complete all as specified and as directed.
Supply, laying, connecting and testing LT UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts grade, 3.5 core, cross sectional area 50 sqmm in bridges / culvert / trenches / drawn through pipe / fixed on walls / bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipments complete all as specified and as directed.
Note for item No 25.00 to 27.00:-
(a) Lugs and glands shall be used appropriately wherever required while connecting cables to the panel board and the quoted rates are deemed be include for the same.
(b) Earthwork, sand cushioning, protection for cable etc., as required shall be measured and paid separately.
Supply and fix dust and vermin proof Street light panel Timelite distribution board 63A, 3 pole, 230V , 3 phase analog time switch with the following features:- (i) Frame - 1 (ii) Max load - 12KW (iii) Timer Digital contactor - 65 Amps TP (iv) MCB - 63 Amps TPN (v) Degree of protection - IP 54
Supply, fixing or passing through pipe, FR PVC insaulated round sheathed copper conductor, 1100 volts grade, heavy duty (flexible), 3 core 1.5sqmm including suitable size PVC conduit but not less than 19mm dia complete all as specified and as directed.
Junction box, sheet moulding compound (SMC) type with hinged type door, weather proof, dust and vermin proof, locking arrangement off white colour of size 240x130x110 mm, comprising 1 No MCB, 6 Amps, 1 No neutral link complete fixed on pole/wall/ground etc with suitable size clamps, bolts, nuts complete all as specified and as directed. Make : Sintex or equivalent.
Design, fabricate, install, connect, test and commissioning LT electrical feeder pillar panel board, Ac, 3 phase, 4 wire, 415/500 V, 50 Hz, outdoor weather proof type fabricated with 3mm thick mild steel sheet to accommodate the accessories detailed below with hinged door, front and back side openable with locking arrangements, epoxy powder coated to minimum IP-54 protection class of IS-2147, chamber for cable entry and and exit, chamber for aluminium bus bars including aluminium bus bars of suitable capacity a per IS specification insulated with coloured PVC sleeves mounted on suitable insulators and seperators, holes drilled for connections complete all as specified and as directed.
(a) MCCB 100 Amps, 4 pole, 415 V, 25KA adjustable thermal and fixed magnetic type setting - 1 No (b) MCCB 63 Amps, 4 pole, 415 V, 25 KA adjustable thermal and fixed magnetic type setting - 2 No (c) Timer switch Digital type 230 V AC - 1 No (d) Power contactor 3 pole 40 Amps - 1 No (e) Multi functional meter with CT & PTs - 1 No (f) Phas indication lamps - 3 Nos
Note No 1 : All swich gears and timers are panel mounted without enclosures main switches with HRC fuses
Note No 2 : The LT panel board shall be kept on platform 450mm above ground level mounted on base frame work of angle iron 50mm x 50mm x 6mm planted into platform of PCC 1:2:4, type B1 using 20mm graded stone aggregate over PCC foundation of 100mm thickness in PCC 1:4:8, type D2 using 40mm graded stone aggragate, the exposed concrete surfaces shall be rendered in CM 1:4, 10mm thick, finished fair and even and applied white wash three coats.
Removing of old earthing materials and taken on credit and provision of new earthing complete with galvanised iron earth plate electrode 600mm X 600mm X minimum 6mm thick, with and including earthing of 25mm x 4mm GI strip protected by 40mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
Removing of old earthing materials and taken on credit and provision of new earthing complete with galvanised iron earth plate electrode 600mm X 600mm X minimum 6mm thick, with and including earthing of 32mm x 6mm GI strip protected by 40mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
Supply, install, testing and commissioning of 11 KV outdoor type RMU Non extensible with internal copper bus bar consisting of fixed type 2 Nos Motor operated Vaccum Circuit Breaker and 4 Nos Motor operated load break switches module alongwith air insulated metering module. All live parts , bus bars of RMU shall be enclosed in tank to avoid multiple inter connection and sealed for life robotically for the three sides and one side manual welded non magnetic/non ferrile / stainless steel tank Grade 304 of minimum 2.5mm thick having IP 67 degree of protection filled with SF6 gas to fulfill the requirements as per IEC 60376 & 603760 Bas insulation with leakage rate less tha 0.1% per year tested as per IEC 62271-200. Th eunit shall have front cable entry for easy installation. RMU shall be complete with all accessories such as terminal boots, manometer as per IEC standard 62271-20, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. The altitude of installation upto 100m as per IEC 60120. The RMU shall be tested for an internal arc fault of 21KA for 1 sec for tank as per IEC 62271-200 complete as as specified in particular specification and as directed.
rvelectricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .