Tender Value
₹14.4 L
EMD Value
₹18,100
Closing Date
6 Jan 2025, 10:00 amClosed
SO(EnM), Dhori
Office of the General Manager, Dhori, Po- Dhori, Bokaro, pin-825102
Repair and maintenance of 12 nos distribution transformer of different capacity under AADOCM, Dhori Area.
2024_CCL_324212_2
GM(D)/SO(EnM)/DA/24-25/55
Open Tender
Electrical and Maintenance Works
Item Wise
30 days
AADOCM
please refer tender documents
2 documents required · 2 mandatory
₹18,100
4 Feb 2025
26 Dec 2024
7 Jan 2025
27 Dec 2024
6 Jan 2025
27 Dec 2024
27 Dec 2024 - 31 Dec 2024
Amount
Part A Repairing/maintenance of 100KVA, 11/415V lighting transformer installed at old Karkhana of AADOCM.
Providing of spout bushing insulator with stud set primary side.
Providing & fixing of all gaskit at tanki cover, primary & secondary side insulator points, Conservator tanki pipe joints, oil indication place, drain valve joints, etc places
Testing, checking and commissioning of lighting transformer at site
Part B Repairing/maintenance of 630KVA, 11KV/440V Lighting transformer for Power Supply of old W/Shop (karkhana) in r/o AADOCM.
Raditor cleaning and fitting
Replacement of nuts, bolts, washer, and tio rods.
Providing of Buchholz relay, 3'' dia flang type.
Providing & fixing of all gaskit at tanki cover, primary & secondary side insulator points, Conservator tanki pipe joints, oil indication place, drain valve joints, etc places
Providing of spout bushing insulator with stud set primary side.
Testing, checking and commissioning of lighting transformer at site
Part C Repairing/maintenance of 500KVA, 11KV/440V Lighting transformer for Power Supply of Dhori dispensary in r/o AADOCM.
Providing of spout bushing insulator with stud set primary side.
Replacement of nuts, bolts, washer, and tio rods.
Providing & fixing of all gaskit at tanki cover, primary & secondary side insulator points, Conservator tanki pipe joints, oil indication place, drain valve joints, etc places
Repairing of raditor valve
Raditor cleaning and fitting
Providing of breather with silcagel set.
Testing, checking and commissioning of lighting transformer at site
Part D Repairing/maintenance of 250KVA, 11/433V lighting transformer installed at Gorango colony of AADOCM. Sl no. NEI-275
Providing of spout bushing insulator with stud set primary side.
Providing & fixing of all gaskit at tanki cover, primary & secondary side insulator points, Conservator tanki pipe joints, oil indication place, drain valve joints, etc places
Raditor cleaning and fitting
Testing, checking and commissioning of lighting transformer at site
Part E Repairing/maintenance of 250KVA, 11/433V lighting transformer installed at Rajander colony 96 Qtrs of AADOCM. Sl no. NEI-02
Replacement of nuts, bolts, washer, and tio rods.
Providing & fixing of all gaskit at tanki cover, primary & secondary side insulator points, Conservator tanki pipe joints, oil indication place, drain valve joints, etc places
Raditor cleaning and fitting
Replacement of drain valv, size-1"
Testing, checking and commissioning of lighting transformer at site
Part F Repairing/maintenance of 500KVA, 11kv/440V lighting transformer installed at Rajander colony of AADOCM
Replacement of drain valv, size-1"
Providing & fixing of all gaskit at tanki cover, primary & secondary side insulator points, Conservator tanki pipe joints, oil indication place, drain valve joints, etc places
Complete body cleaning, Double coat primer and Enamel painting by Spray painting machine including cost of cleaning and painting materils as well as labour cost.
Providing of spout bushing insulator with stud set primary side.
Testing, checking and commissioning of lighting transformer at site
Part G Repairing/maintenance of 250KVA, 11kv/440V lighting transformer installed at Rajander colony of AADOCM
Replacement of nuts, bolts, washer, and tio rods.
Replacement of drain valv, size-1"
Providing & fixing of all gaskit at tanki cover, primary & secondary side insulator points, Conservator tanki pipe joints, oil indication place, drain valve joints, etc places
Providing of spout bushing insulator with stud set primary side.
Testing, checking and commissioning of lighting transformer at site
Part H Repairing/maintenance of 100KVA, 11kv/440V lighting transformer installed at Amlo W/B check post of AADOCM
Providing & fixing of all gaskit at tanki cover, primary & secondary side insulator points, Conservator tanki pipe joints, oil indication place, drain valve joints, etc places
Replacement of drain valv, size-1"
Providing of spout bushing insulator with stud set primary side.
Testing, checking and commissioning of lighting transformer at site
Part I Repairing/maintenance of 100KVA, 3.3kv/440V lighting transformer installed at 12 no. Sub-station of AADOCM. Sl no. 2246(local Sl no.Tr/05)
Providing of spout bushing insulator with stud set primary side.
Providing & fixing of all gaskit at tanki cover, primary & secondary side insulator points, Conservator tanki pipe joints, oil indication place, drain valve joints, etc places
Testing, checking and commissioning of lighting transformer at site
Part J Repairing/maintenance of 100KVA, 3.3/440V lighting transformer installed at Amlo transport sub-station of AADOCM. Local sl no. Tr/06
Replacement of nuts, bolts, washer, and tio rods.
Providing of spout bushing insulator with stud set primary side.
Testing, checking and commissioning of lighting transformer at site
Part K Repairing/maintenance of 63KVA, 3.3/440V lighting transformer installed at Amlo transport sub-station of AADOCM. Local sl no. Tr/02
Replacement of drain valv, size-1"
Providing of spout bushing insulator with stud set primary side.
Testing, checking and commissioning of lighting transformer at site
Part L Repairing/maintenance of 50KVA, 3.3/440V lighting transformer installed at 4 no. coal stock of AADOCM.
Providing of spout bushing insulator with stud set primary side.
Replacement of drain valv, size-1"
Testing, checking and commissioning of lighting transformer at site
Supervision , incidental & overhead expenses
Total impact of GST for the purpose of CTC
M/S NATIONAL ELECTRICAL WORKS (BID ID -1114516)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .