Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.1 CrAccepted-AOC PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | ₹1.1 Cr | 1 | Accepted-AOC OK |
| 2 | 2₹1.1 Cr+₹6.1 L (5.68%)Rejected-Finance | ₹1.1 Cr+₹6.1 L (5.68%) | 2 | Rejected-Finance Not lowest |
| 3 | 3₹1.1 Cr+₹7.9 L (7.43%)Rejected-Finance 402 C WING BUILDING NO 86 NAVRANG CO OP HSG SOCIETY LTD TILAKNAGAR CHEMBUR MUMBAI 89 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400089 | ₹1.1 Cr+₹7.9 L (7.43%) | 3 | Rejected-Finance Not lowest |
| 4 | Rejected-Technical 78 14 DEEN DAYAL NAGAR KARERA KARERA SHIVPURI MADHYA PRADESH 473660 UDYAM MP 45 0004529 | SHIVPURI | MADHYA PRADESH | 473660 | - | - | Rejected-Technical Adverse remarks in WLR of CESC QE Mar 2021 |
Tender Value
Refer Docs
EMD Value
₹1.9 L
Closing Date
9 Aug 2021, 6:00 pmClosed
CE R and D Secunderabad
CE R and D Picket Secunderabad
SPECIAL REPAIRS TO MANAGEMENT BLOCK AT NMRL AMBERNATH
2021_MES_457312_1
CA NO.CERD/PSN/TOKEN/14 OF 2020 -2021
Open Tender
Civil Works
Item Rate
365 days
Ambernath
As per NIT
7 documents required · 7 mandatory
₹1,000
Yes
GE I R and D Pashan Pune
₹1.9 L
Yes
17 Sept 2021
5 Jul 2021
14 Aug 2021
5 Jul 2021
9 Aug 2021
26 Jul 2021
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the MD land premises, complete all as specified and directed.
Demolition of cement concrete in floors not exceeding 150mm thick below & above ground level and removing demolition material out of site exceeding 1.5 Kilometre but not exceeding 5.00 Kilometre and depositing where directed complete all as specified and directed.
Providing 25 mm thick plain cement concrete 1:2:4 type B0 (12.5mm graded stone aggregate) as floor sub base to receive any type of floor finishes complete all as specified and directed.
Machine cut Granite (of any type) stone slab of 18-20mm thick (table rubbed and polished) as in floors and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, laid over and including provision of 15mm thick screed bed in CM 1:4 and including cutting ,grinding , rounding the smooth edges and polishing complete all as specified and directed.
Machine cut Granite (of any type) stone slab of 18-20mm thick (table rubbed and polished) as in skirting /dado/steps /risers etc as in single piece and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, laid over and including provision of 15mm thick backing coat in CM 1:4 and including cutting ,grinding , rounding the smooth edges and polishing complete all as specified and directed.
Double charged fully Vitrified tiles, LIGHT colour 8 to9 mm thick of size 600mm x 600mm polished in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match coloured tiles , laid over and including provision of 15mm thick screed bed or bedding layer in CM 1:4 complete all as specified and directed.
Double charged fully Vitrified tiles, LIGHT colour 8 to 9 mm thick polished as in dado/ skirting set and jointed in neat cement slurry and pointed in coloured cement to match coloured tiles , laid over and including provision of 10mm thick backing coat in CM 1:3 complete all as specified and directed.
Non - skid Ceramic coloured tiles (Grade B-IIa) of superior quality of size 400mmx400mmx 7 to 8 mm thick in floors, set and jointed in neat cement slurry and pointed with tile epoxy to match coloured tiles , laid over and including provision of15mm thick screed bed or bedding layer in CM 1:4, complete all as specified and directed.
Glazed ceramic tiles (Grade B-III) of superior quality in vertical surfaces such as dado/ skirting 300 mm x 600 mm x 7 to 8 mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match, laid over and including 10 mm thick backing coat in CM 1:3 complete all as specified and directed.
Non - skid Ceramic coloured tiles (Grade B-IIa) of superior quality of size 300mmx300mmx 7 to 8 mm thick in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles , laid over and including provision of15mm thick screed bed or bedding layer in CM 1:4, complete all as specified and directed.
Glossy finished 60 mm thick machine pressed precast concrete interlocking paver block any shape and size, with grey cement and pigment, confirming to IS 15658-2006 -M-35 Grade complete all as specified and directed. Make as approved by GE.
50 mm thick Crushed stone sand /M-sand in cushioning for interlocking tiles complete complete all as specified and directed.
Dismantling mild steel works complete all as specified and directed.
Stanless Steel Railing in 304 grade material for stair case railing of height 0.95 metre with top rail pipe 75mm dia 16 gauge, verticle pipe 50 mm dia 16 gauge @ n exc 2.00 metre centre to centre and turning and corners and three longitudinal parellel pipe of size 20 mm dia 16 gauge including connected socket, base coupling, brackets, tee, cross, bend, fixed side of steps with neccesary fasteners complete mat finish including dismantling of old existing railing complete all as specified and directed.
Taking down shutters of any description ( Cabinet and Cupboard shutters) area exceeding 1.0sq.m but not exceeding 2.0 sq.m each complete all as specified and directed.
Taking down chowkats or frames with shutters including grills (without taking off shutters from the frames), area exceeding 1.5sq.m each but not exceeding 4.0sq.m each, complete all as specified and directed.
Second class hard wood plain, solid straight chowkats or frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue and pinned at joints including cutting holes in brick walls in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concerete 1:2:4 type B-1 as required (depth of embedded portion of holdfasts exceeding half brick but not exceeding one brick) and including supply and fixing of holdfasts complete all as specified and as directed.
35mm thick factory made flush shutters, solid core construction with block board core and plywood face panels and commercial decorative veneering on both sides complete all as specified and directed.
Aluminium die cast body door closer hydraulically regulated, designation No, 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61to 80 kg ,aluminium die cast body complete all as specified and directed.
300mm long Aluminium alloy, anodised, sliding door bolt, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixed, complete all as specified and directed.
200 mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
Extruded aluminium handles, fabricated type, anodised, 150mm long, complete all as specified and directed.
Stainless steel Butt hinges 100mm size medium weight as per IS 12817-2013 finished bright with smooth surface without chemical coating complete all as specified and directed.
French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works and applying two coats of french polish complete all as specified and directed.
Taking down shutters of any description area not exceeding 1.0sq.m each complete all as specified and directed.
Aluminium powder coated any colour (minimum thickness of powder coating 50 micron ) frame for doors,partition , windows and ventilators with one or more rebates including cleat for fixing etc complete all as specified and directed.
Aluminium door shutters powder coated any colour (minimum thickness of powder coating 50 micron) aluminium section weighing 0.55 kg per metre including necessary joining cleats glazing clips, rubber neoprene packing. handles 2 Nos in each door, hinges anodised aluminium snap beading screws etc complete all as specified and directed.
Aluminium window and ventilator shutters powder coated any colour (minimum thickness of powder coating 50 micron), fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specified and directed. Note: The rates quoted shall deemed to include aluminium sliding shutter wherever required in track system and rates should also include supply and fixing of sliding lock latches and fittings required for aluminium windows.
Sheet glass, 4.8 mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5 sq. m in each pane of aluminium door / window / ventilator etc., complete all as specified and directed.
Figured glass, 4.0 mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5 sq. m in each pane of aluminium door / window / ventilator etc., complete all as specified and directed.
12 mm thick prelaminated particle board, exterior grade decorative lamination on both faces fixed in aluminium partition /doors etc complete all as specified and directed.
Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified and directed.
Demolition of brick /stone masonry walls, built in cement mortar including all quoins, arches, pillars, etc complete all as specified and directed.
Taking down cement plaster on brick or concrete surfaces, etc. including raking out joints, hacking for key, scrubbing down with water, etc.and removing rubbish off the premises of MD land, complete all as specified and directed.
Rendering 10mm thick in CM 1:6 on brick work or concrete surfaces finishing the surface even and smooth with out using extra cement complete all as specified and directed.
Rendering 5 mm thick, in CM 1:3 on ceiling, chajjas and facias and finishing the surfaces even and smooth with out using extra cement complete all as specified and directed.
Rendering 15mm thick in two layers (first coat 10mm thick in CM 1:6 and second coat 5mm thick CM 1:4 mixed with water proofing liquid) on fair faces of brick work or concrete surfaces and finishing the surface even and smooth with out using extra cement on external walls complete all as specified and directed. NOTE: Water proofing liquid shall be measured and paid separately under respective item of this Schedule.
Preparation of new plastered surfaces of walls, columns and applying two coat of acrylic emulsion distemper over a coat of alkali resistant primer complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying three coats of white wash on ceiling complete all as specified and directed.
Complete removal of existing treatment from external surfaces of walls including pilasters, cornices etc., by scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots with wire brushes and removing existing loose particles etc., and applying two coats of weather-proof exterior emulsion paint over a coat of exterior grade acrylic wall primer and over two coats of external grade wall care putty (total thickness not less than 1.50mm in two coats) finished even and smooth any height including necessary scaffolding etc. complete all as specified and directed.
Complete removal of existing treatment on surfaces of walls by scraping with wire brushes, washing down with water and applying two coats of acrylic emulsion distemper over a coat of alkali resistant primer at any height including necessary scaffolding etc. complete all as specified and directed.
Complete removal of existing treatment on surfaces of ceiling by scraping with wire brushes, washing down with water and applying two coats of acrylic emulsion distemper over a coat of alkali resistant primer at any height including necessary scaffolding etc complete all as specified and directed.
French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on old works and applying one coat of french polish complete all as specified and directed.
Preparation of old painted wooden surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Vitreous china squatting pan 'Orissa" pattern, size 580x440mm ivory colour, integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti-syphonage pipe, WC pan shall be set in lean concrete below level of rim of pan to receive the floor finish etc complete and including taking down existing unserviceable one complete all as specified and as directed.
Vitreous China wash down water closet pan (pedestal pattern), ivory colour (excluding fixing bolts, flushing cistern and flush pipe), including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc., with and including provision of seat cover black closed pattern with flat bottom with mild steel CP hinging device including taking down existing unserviceable one complete all as specified and directed.
Urinal, vitreous china, full stall type, white, (including flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement with grating and union etc., including taking down existing one complete all as specified and directed.
PVC valveless, syphonic action type, flushing cistern, 10 litre capacity, low level, white, with inlet, ball valve, float and handle including brackets, jointing with existing 32mm dia flush pipe and connections to pipes and fixing of chain and pull, or lever, taking down existing unserviceable one complete all as specified and directed.
Wash hand basin, Vitreous China, first quality, white colour, of size 550x400mm including cutting for and pinning in ends of brackets or erecting stand, with and including GI brackets, including taking down existing item complete all as specified and directed.
Pillar taps, cast copper alloy, with capstan heads, fancy type, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, 15mm bore, including taking down old pillar tap of any dia, complete all as specified and directed.
Stop cock , cast copper alloy, fancy type, chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, 15mm bore, including taking down unserviceable stop valve of any size, complete all as specified and directed.
32mm bore CP waste coupling (half or full threaded ) including taking down existing item complete all as specified and directed.
PVC connections 15mm size with PTMT nuts of length 450mm, both ends having brass coupling nut and PVC washers, complete all as specified and directed.
Bib taps, cast copper alloy, fancy type, chromium plated, long body with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule , 15mm bore, with CP flange, including taking down old bib tap of any dia, complete all as specified and directed.(Minimum weight 550grams per each)
Towel ring 200 mm dia 1.6 mm thick brass Chromium plated of stainless fixed to wall etc including taking down existing one complete all as specified and directed.
Chromium plated 100 mm dia grating including taking down existing one complete all as specified and directed.
Taking down rainwater pipes (any size or pattern),including all fittings heads, shoes, bends, swan-necks etc (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
75mm bore UPVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with and including provision of suitable size of PVC clamps complete all as specified and directed.
110mm bore UPVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with and including provision of suitable size of PVC clamps complete all as specified and directed.
UPVC (SWR) bends any radius, 75mm bore with access door complete all as specified and directed.
UPVC (SWR) bends any radius, 110mm bore with access door complete all as specified and directed.
75mm bore UPVC (SWR) branch piece single (single 'T' ) equal or unequal, with access door, complete all as specified and directed.
110mm bore UPVC (SWR) branch piece single (single 'T' ) equal or unequal, with access door, complete all as specified and directed.
UPVC (SWR) vent cowl, 75mm bore, complete all as specified and directed.
UPVC (SWR) vent cowl, 110 mm bore, complete all as specified and directed.
75 mm bore UPVC (SWR) multi floor trap / nahni trap, plain / single hole chromium plated grating including jointing to waste pipe with solvent cement, fixed in PCC 1:2:4 type B1 including taking down existing floor trap complete all as specified and directed.
Taking up or down steel tubing and connections, 20mm bore, complete all as specified and directed.
Supplying and laying of 16 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors complete all as specified and directed.
Supplying and laying of 20 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls / ceiling or laying in floors complete all as specified and directed. Note: The rates quoted for item No. 69 & 70 shall deemed to include special CPVC fittings items required to connect the pipe with bib tap, angle valve, stop valve, gate valve, water tank etc, such as brass elbow, brass tee, male threaded adapter, female threaded adaptor, tank adaptor etc.
Providing & fixing of Armstrong Mineral Fibre Acoustical Suspended Ceiling System with Fine Fissured (Bevelled Tegular) Edge Tiles with Armstrong 15mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.6, Light Reflectance >85%, Thermal Conductivity k=0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0/Class 1 (BS 476 pt-6 & 7) in module size of 600 x 600 x16mm, suitable for Green Building application, with Recycled content of 31%. The tile shall be laid on Armstrong Suprafine 32 with 15mm wide T section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200mm & 600mm cross Tees with a web height of 32mm and a load carrying capacity of 7.5 Kgs/M2 & minimum pull out strength of 100 Kgs. The 'T' sections have galvanising of 90 grams per M2 and need to be installed with suspension system complete all as specified and directed. Makes: Armstrong or equivalent in Saint Gobain.
Taking down existing roof treatment of any description with bituminous felt including plaster / loose concrete and roughening the surfaces of old concrete by picking, scraping, cleaning and washing down with water to remove all dust etc complete all as specified and directed including disposing off out side MD land.
Brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified and directed.
PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregate as in leveling course thickness 40mm to match the undulations of roof including form work if any mixed with water proofing liquid including necessary form work complete all as specified and directed. NOTE: Water proofing liquid shall be measured and paid for separately as supply only.
Four course water proofing treatment to roof using APP based polymeric membrane minimum weighing 3.0Kg/Sqm and minimum 3mm thick reinforced with polyester non woven fabric (not less than 150 grams per sq.m) laid over primed surface including torching by butane torch with commercial gas cylinder by forced application, complete all as specified and directed. Four course treatment shall be as under:- (i) Applying one coat of bituminous primer conforming to IS-3384 @0.3 litre per sqm (ii) Laying of APP based membrane as specified thickness and weight (iii) Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.20 Kg/Sqm including cleaning surfaces. (iv) Applying two coats of aluminium paint @ 100 ml/sqm for each coat. (v) The work shall be got executed through authorized applicator of manufacturer as approved by GE. (vi) Contractor has to submit guarantee for effectiveness of water proofing treatment for 10 years.
Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified and directed.
Bitumastic gola, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surfaces complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
Dismantling unsound and damaged /distressed plaster / concrete by scrapping with utmost care to expose reinforcement , cleaning the rusted reinforcement by rubbing with wire brushes or emery paper and including disposal of debris not exceeding 500 metre complete all as specified and as directed.
Applying epoxy based bonding material Nitobond EP of FOSROC or equivalent of PIDILITE over cleaned exposed reinforcement as well as new reinforcement provided for corrosion prevention and fresh plaster bonding to old concrete complete all as specified and as directed.
Hard drawn steel wire fabric not exceeding 4kg per sqm cut to length, bent to shape fixing with and including mild steel wire annealed not less than 0.9 mm dia as in reinforcement up to height of 10 metre from ground complete all as specified and as directed.
Pressure guniting 40 mm thick to effected area of RCC / masonry surfaces including necessary scaffolding for the height of 4 metre from ground using sprayset HBL of FOSROC or equivalent of PIDILITE @5% per 100 kg of cement and coarse sand in the ratio of 1:3 as per manufacturers instructions complete all as specified and directed. Note: Supply of Sprayset HBLof FOSROC or equvalent of PIDILITE will be measured and paid separately.
Supply only Sprayset HBL of FOSROC or equivalent of PIDILITE complete all as specified and directed.
Rendering 10 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth with out using extra cement using water proofing liquid as per manufacturers instructions, complete all as specified and as directed. Note: Supply only water proofing liquid will be measured and paid separately.
Preparing of newly plastered surfaces and applying two coats of weather-proof exterior emulsion paint over a coat of alkali resistant primer complete all as specified and directed.
TMT bars 8 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and as directed.
Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), 1000 litre capacity (ISI embossed), double layered, hoisted and fixed in position complete all as specified in SSR Part I including taking down existing one complete all as specified and directed.
20 mm dia bore Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed.minimum weight 210gms complete including taking down existing ball valve any type complete all as specified and directed.
20 mm bore Gun metal, globe or gate valves with iron wheel head, ISI Marked screwed both ends for iron/GI pipe and fixed including taking down existing gate valve complete all as specified.
Supply, installing, testing and commissioning factory made and CPRI approved LT panel board outdorr type, weather, vermin proof, cubical type, platform mounted suitable for 415 volts, 3 phase 4 wire 50 Hz AC supply system all as specified and directed with necessary insulated bus bar arrangement of 4 strips, the panel should be dust proof, IP 54 class protection and made out of 3.0 mm thick CRCA mild steel sheet with 50x50x6mm angle iron frame with necessary earth work excavation, hinged doors, front and rear opening and locking arrangement and duly powder coated on the out side and inside ,,cable glands and lugs for incoming and out going cable etc ,independent chamber to accommodate complete all as specified and directed including following accessories:- INCOMING a) Bus bar chamber with electrolytic aluminium bus bar suitable for 800 amps capacity for 3 phase and neutral ( all connection inside the panel shall be through aluminium strip) connected duly supported with FRP insulators including colour code heat shrieked insulating sleeves-Set -1 b) MCCB 4 pole adjustable thermal magnetic setting 400 Amps ,415 Volts 50 KA -01 No. OUTGOING b) MCCB 3 pole 100 Amps ,415 Volts 10 KA over load and short circuit protection ,adjustable thermal magnetic release type -04 Nos b)MCB TPN 40 Amps ,415 Volts -08 Nos c) Indicator lamp 22.5 mm dia RYB ,230 Volts - 01 Set d) Panel wiring with suitable size PVC insulated heavy duty 1100 Volts grade single core cable with copper conductor multistranded with cable termination lugs e) Necessary wiring copper made for digital LED indicators and Amp ,Volt metering system
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, tubular poles or laying of pipes, or for removal / laying of cables etc., not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in soft loose soil, including trimming sides of foundations and aforming bottom surface to required level, complete all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, tubular poles or laying of pipes, or for removal / laying of cables etc., not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in hard/dense soil, including trimming sides of foundations and aforming bottom surface to required level, complete all as specified and directed.
Returning, filling in, in soils, including spreading, levelling, watering and well ramming in layers not exceeding 25cm., complete all as specified and directed.
Removing surplus excavated soils to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and directed.
Labour only for spreading riddled earth obtained from excavation work for cable protection, complete all as specified and directed. NOTE:- Punned thickness shall only be measured and paid.
Supply and laying common burnt clay Bricks class 'B' designation 75 old size 230mm x 115mm x 75mm in trenches for cable protection, complete all as specified and directed.
Galvanized iron tubing light grade of the size 80mm dia for protection of cable under road, floors etc complete all as specified and directed.
Supply, lay, test and commissioning of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor, LT 1100 volts grade, ISI mark as per IS-7098 (Part -1) -1985, cross-sectional area 150 sq.mm 3.5 core, laid in trenches / on poles / walls including provision of suitable hardware accessories, connecting up, testing on completion and commissioning complete all as specified and directed.
Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials and making good disturbed surfaces of walls, floors, etc, complete all as specified and directed.
Taking down carefully DBs any type any size, two pin and earth plug etc all as specified and making good to the disturbed surfaces to match with the existing complete all as specified and directed.
Taking down old unserviceable light fittings of any capacity complete all as specified and directed.
Taking down ceiling fans of 1200/1400mm sweep and painting with one coat of synthetic enamel paint by sparying including filling cavities with filler after cleaning all dust etc and hanging ceiling fan and conecting up including provision of cable from ceiling rose or connector to fan after completion of civil works complete all as specified and directed.
Taking down exhaust fans any sweep and painting with one coat of synthetic enamel paint by sparying including filling cavities with filler after cleaning all dust etc and hanging ceiling fan and conecting up including provision of cable from ceiling rose or connector to fan after completion of civil works complete all as specified and directed.
Point wiring complete with 1.5 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor 1100 V grade drawn through and including 20mm dia PVC conduit, medium grade, and conduit accessories, concealed in the walls /ceiling and terminated to sunken box of modular type and including provision of GI modular box ISI marked in the walls suitable for modular switches, sockets etc., and including modular white plates for fixing modular switches, sockets / regulators etc., including 1.5sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly with brass screws, washers, copper lugs etc., complete all as specified and directed for one light / fan point /bell point/ceiling fan point/exhaust point controlled by one, one-way switch 5 Amp. NOTE: 1. The quoted rate shall deemed to include the cost of Modular boxes, modular white cover plate, provision of blank plates as per requirement etc. 2.Rates deemed to be including cutting groves and nitch for fixing of Modular boxes / conduit pipe where ever required and making good the disturbed surfaces of wall / ceiling matching with adjoining surfaces .
All as per Sl. Item No. 104 here-in-before but for one 3-pin 5/6Amp socket outlet point on same board controlled by one one-way 5/6Amp switch, complete all as specified and directed.
All as per Sl. Item No. 104 here-in-before but for one 3-pin 5/6Amp socket outlet point on independent board controlled by one one-way 5/6Amp switch, complete all as specified and directed.
Point wiring complete with 2.5 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor 1100 Volts grade, ISI marked, drawn through in and including 20mm dia rigid PVC conduit medium grade and conduit accessories, concealed in the walls /ceiling and terminated to sunken box of modular type and including provision of GI modular box ISI marked in the walls suitable for modular switches, sockets etc., and including modular white plates for fixing modular switches, sockets / regulators etc., including 2.5 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly with brass screws, washers, copper lugs etc., complete all as specified and directed for 3-pin 15/16 Amp socket outlet point on independent board, complete all as specified and directed. NOTE: 1. The quoted rate shall deemed to include the cost of modular boxes, modular white cover plate, provision of blank plates as per requirement etc. 2.Rates deemed to be including cutting groves and nitch for fixing of Modular boxes / conduit pipe where ever required and making good the disturbed surfaces of wall / ceiling matching with adjoining surfaces .
Modular Switch 6 Amps 240 V one way, 1 module complete all as specified and directed.
Modular Switch 16 Amps, 240 V one way, 1 module complete all as specified and directed.
Modular Socket 6 Amps (3 pin) 2 module complete all as specified and directed.
Modular Socket 6/16Amps 2 in 1 (6 pin) 2 module complete all as specified and directed.
Fan step regulator, 120W -2 Module 230Volts complete all as specified and directed.
Ceiling rose of size 65x75mm three terminal surface bakelite type AC 50 Hz 230V, complete all as specified and directed.
Modular bell push 6 Amps, 240 V one way, 1 module complete all as specified and directed.
Bell multi music type complete all as specified and directed.
High efficient LED batten surface /wall monted specially designed extruded thermal polycarbonate housing high optically efficient polycorbonate diffuser ,in built electronic driver duly wired upto thermal block, IP20 ,CRI 80 ,temparature rage 0 to 50 degree centigrade , driver efficiency 95 & power facor 0.95 ,THD 20% ,Color temparature -6500 K ,Surge protection 2.5 KV ,50000 burning hours as per L70 Criteria ,Multistage isolated constant current operated driver with range 150-270 V AC and safety extra low voltage safe level 60V DC as per IEC standard ,LED batten wattage 20 W with Lumnaire lumen 2000 and system efficacy 100lm/W complete all as specified and directed.
Industrial channel with high luminous efficacy LED and energy efficient driver, ultra slim, light weight design in high quality extruded Sabic LUX grade optics and powder coated CRCA steel housing, opal polycarbonate diffuser with energy eiicient LED driver duly wired up to terminal block , luminaire lumen > 4150, CRI > 80 efficacy > 170 lm/W color temparature -5700 K ,IP20, system efficacy > 105lm/ W, 5000 burning hours as per L70 Criteria, Ambient temparature range 0 to 50 Deg C, driver efficiency > 80%, THD < 10%, Power factor > 0.95, Surge protection in CM-3.0 KV, multistage isolated constant current - constant voltage opearated driver with range 150-270V AC and safety eatra low voltage safe level < 60 V DC as per IEC standard, wattge < 20W complete all as specified and directed.
MCB DB SPN double door 4-way sheet metal enclosure factory made suitable for MCBs 240volts confirming to IEC -61439-3 with 200 amps rated busbar, neutral & earthing link bar, surface mounting and making good distrubed surfaces complete all as specified and directed. Note: All MCBs shall be measured and paid under appropriate item.
MCB DB SPN double door 8-way sheet metal enclosure factory made suitable for MCBs 240volts confirming to IEC -61439-3 with 200 amps rated busbar ,neutral & earthing link bar ,surface mounting and making good distrubed surfaces complete all as specified and directed. Note: All MCBs shall be measured and paid under appropriate item .
MCB DB SPN double door 12-way sheet metal enclosure factory made suitable for MCBs 240volts confirming to IEC -61439-3 with 200 amps rated busbar ,neutral & earthing link bar ,surface mounting and making good distrubed surfaces complete all as specified and directed. Note: All MCBs shall be measured and paid under appropriate item .
MCB DB SPN double door 8-way sheet metal enclosure factory made suitable for MCBs, 415volts confirming to IEC -61439-3 with 200 Amps rated bus bar, neutral & earthing link bar, surface mounting and making good distrubed surfaces complete all as specified and directed. Note: All MCBs shall be measured and paid under appropriate item.
MCB DB SPN double door 4-way sheet metal enclosure factory made suitable for MCBs, 415volts confirming to IEC -61439-3 with 200 Amps rated bus bar, neutral & earthing link bar, surface mounting and making good distrubed surfaces complete all as specified and directed. Note: All MCBs shall be measured and paid under appropriate item.
Sheet metal enclosure with three pole and neutral with 3 pin and earth plug and socket complete with one single pole MCB 20 Amps 240 volts A/C and 20 Amps industrial plug top complete all as specified and directed .
MCB triple pole and neatral 60 Amp, 415 Volt, 'C' curve, 10KA breaking capacity, complete all as specified and directed.
MCB SPN 6 to 32 Amp, 240 Volt, 'C' curve, 10KA breaking capacity, complete all as specified and directed.
MCB SPN 40 Amp, 240 Volt, 'C' curve, 10KA breaking capacity, complete all as specified and directed.
Cutting , chases for connecting the conduit in old brick /stone masonry wall including making good the disturbed surface to matching with existing one complete all as specified and directed.
Rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth, tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc for size 25 mm external dia for laying of telephone and speaker cables complete all as specified and directed.
Taking down carefully sub main wiring of any size including conduit and making good disturbed surfaces of walls /ceiling etc complete all as specified and directed.
Sub main wiring complete with 2 runs of single core 2.5 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of non-metallic rigid heavy duty PVC conduit 25mm dia external but shall be increased as per actual site requirement and its accessories wall thickness not less than 1.8 mm ,concealed in brick masonry walls etc in and including cutting& chasing and making good the surface to match the existing and connecting terminal ends to DB's including providing 1 run of single core 2.5 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, including taking down old sub main wiring of any type and any size complete all as specified and directed. NOTE:- (i) Two runs of 2.5 sq.mm copper conductor, One run of 2.5 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) The rate quoted per unit shall be deemed to be inclusive of the extra length of cable /wire required for connection to MCBs .
Sub main wiring complete with 2 runs of single core 4.0 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of non-metallic rigid heavy duty PVC conduit 25mm dia external but shall be increased as per actual site requirement and its accessories wall thickness not less than 1.8 mm ,concealed in brick masonry walls etc in and including cutting& chasing and making good the surface to match the existing and connecting terminal ends to DB's including providing 1 run of single core 4.0 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, including taking down old sub main wiring of any type and any size complete all as specified and directed. NOTE:- (i) Two runs of 4.0sq.mm copper conductor, One run of 4.0 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) The rate quoted per unit shall be deemed to be inclusive of the extra length of cable /wire required for connection to MCBs .
Sub main wiring complete with 2 runs of single core 6.0 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of non-metallic rigid heavy duty PVC conduit 25mm dia external but shall be increased as per actual site requirement and its accessories wall thickness not less than 1.8 mm ,concealed in brick masonry walls etc in and including cutting& chasing and making good the surface to match the existing and connecting terminal ends to DB's including providing 1 run of single core 6.0 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, including taking down old sub main wiring of any type and any size complete all as specified and directed. NOTE:- (i) Two runs of 6.0sq.mm copper conductor, One run of 6.0 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) The rate quoted per unit shall be deemed to be inclusive of the extra length of cable /wire required for connection to MCBs .
Sub main wiring complete with 2 runs of single core 10.0 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of non-metallic rigid heavy duty PVC conduit 32mm dia external but shall be increased as per actual site requirement and its accessories wall thickness not less than 1.8 mm ,concealed in brick masonry walls etc in and including cutting& chasing and making good the surface to match the existing and connecting terminal ends to DB's including providing 1 run of single core 10.0 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, including taking down old sub main wiring of any type and any size complete all as specified and directed. NOTE:- (i) Two runs of 10.0sq.mm copper conductor, One run of 10.0 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) The rate quoted per unit shall be deemed to be inclusive of the extra length of cable /wire required for connection to MCBs .
Sub main wiring complete with 4 runs of single core 6.0 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of non-metallic rigid heavy duty PVC conduit not less than 40mm dia external but shall be increased as per actual site requirement and its accessories wall thickness not less than 1.8 mm ,concealed in brick masonry walls etc in and including cutting& chasing and making good the surface to match the existing and connecting terminal ends to DB's including providing 2 runs of single core 6.0 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, including taking down old sub main wiring of any type and any size complete all as specified and directed. NOTE:- (i) Four runs of 6.0sq.mm copper conductor, Two runs of 6.0 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) The rate quoted per unit shall be deemed to be inclusive of the extra length of cable /wire required for connection to MCBs .
Sub main wiring complete with 4 runs of single core 10.0 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of non-metallic rigid heavy duty PVC conduit 40mm dia external but shall be increased as per actual site requirement and its accessories wall thickness not less than 1.8 mm ,concealed in brick masonry walls etc in and including cutting& chasing and making good the surface to match the existing and connecting terminal ends to DB's including providing 2 runs of single core 10.0 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, including taking down old sub main wiring of any type and any size complete all as specified and directed. NOTE:- (i) Four runs of 10.0sq.mm copper conductor, Two runs of 10.0 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) The rate quoted per unit shall be deemed to be inclusive of the extra length of cable /wire required for connection to MCBs .
Sub main wiring complete with 4 runs of single core 16.0 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of non-metallic rigid heavy duty PVC conduit not less than 40mm dia external but shall be increased as per actual site requirement and its accessories wall thickness not less than 1.8 mm ,concealed in brick masonry walls etc in and including cutting& chasing and making good the surface to match the existing and connecting terminal ends to DB's including providing 2 runs of single core 16.0 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, including taking down old sub main wiring of any type and any size complete all as specified and directed. NOTE:- (i) Four runs of 16.0sq.mm copper conductor, Two runs of 16.0 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) The rate quoted per unit shall be deemed to be inclusive of the extra length of cable /wire required for connection to MCBs .
Sub main wiring complete with 4 runs of single core 25 Sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of non-metallic rigid heavy duty PVC conduit not less than 40mm dia external but shall be increased as per actual site requirement and its accessories wall thickness not less than 1.8 mm ,concealed in brick masonry walls etc in and including cutting& chasing and making good the surface to match the existing and connecting terminal ends to DB's including providing 2 runs of single core 16.0 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, including taking down old sub main wiring of any type and any size complete all as specified and directed. NOTE:- (i) Four runs of 25.0sq.mm copper conductor, Two runs of 16.0 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) The rate quoted per unit shall be deemed to be inclusive of the extra length of cable /wire required for connection to MCBs .
Earthing complete with GI earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth wire 4mm dia by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 15mm dia GI pipe 'light grade', GI watering pipe 20mm dia GI pipe 'medium grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 50mm thick RCC cover (1:2:4) mix as in cover slab with 8mm dia TMT bars as in reinforcement @ 150mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciifed and as directed. NOTE:-1 Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC chamber , funnel and RCC cover plate.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed and dispose the dismantled material out of MoD land.
10mm thick screed / cement plaster in cement mortar 1:4 over PCC (while concrete is green) using approved liquid water proofing compound as per manufactures instructions complete all as specified and directed. Note: Supply of liquid water proofing compound will measured and paid separately.
Brick work with sub class 'B' bricks, straight or curved or plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
Brick work with sub class 'B' bricks, straight or curved or plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
Perforated GI cable tray made out of 14 SWG galvanised sheet of size 300mmx 50 mm fixed complete on walls and columns and necessary angle iron supports , mild steel clamps including two coats of synthetic enamel painting over a coat of primer complete all as specified and directed.
Perforated GI cable tray made out of 14 SWG galvanised sheet of size 150mmx 50 mm fixed complete on walls and columns and necessary angle iron supports , mild steel clamps including two coats of synthetic enamel painting over a coat of primer complete all as specified and directed.
Modern Engineering Co
Sai construction & services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .