Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹26.0 LAccepted-AOC | 1 | Accepted-AOC The lowest bidder M/s Auto Traders is accepted please. | |
| 2 | 2nd₹26.7 L+₹65,187.92 (2.51%)Rejected-Finance | 2nd | Rejected-Finance L2 | |
| 3 | 3rd₹26.8 L+₹76,291.32 (2.93%)Rejected-Finance | 3rd | Rejected-Finance L3 | |
| 4 | 4th₹26.8 L+₹77,033.82 (2.96%)Rejected-Finance | 4th | Rejected-Finance L4 | |
| 5 | 5th₹26.9 L+₹86,941.20 (3.34%)Rejected-Finance | 5th | Rejected-Finance L5 |
Tender Value
₹27.2 L
EMD Value
₹54,364
Closing Date
17 Oct 2023, 6:00 pmClosed
GE AWC MHOW
GE AWC MHOW
SPECIAL REPAIRS TO REPLACEMENT OF LT OVERHEAD LINES WITH UG CABLES AT VINDYA VIHAR UNDER GE(AWC)MHOW.
2023_MES_603817_2
8683 GE(AWC) /MHOW / OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE AWC MHOW
All as per NIT and Tender Documents
7 documents required · 7 mandatory
₹500
Yes
GE AWC MHOW
₹54,364
Yes
22 Jan 2024
25 Sept 2023
18 Oct 2023
26 Sept 2023
17 Oct 2023
3 Oct 2023
Amount
Supplying, laying, fixing, jointing and testing LT under ground XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm x 4 Core, IS 7098 marked, with electric connection lugs, laid in trenches/under floor or fixed naked with walls / on poles/ in ducts / in GI pipes etc. and including taking down complete all as specified and directed. Note - Excavation, earth work, sand cushioning, PCC cover and GI pipe shall be measured and paid separately.
Description same as per Item No. 01 above but 95 sqmm x 3.5 Core complete all as specified and directed.
Dismantling of old u/s ACSR or AAC conductors, all as specified and directed
Dismantling of old u/s GI earth wire or service feeder or distribution span all as specified and directed
Dismantling of old u/s insulators of any type and any size all as specified and directed.
Supply and laying GI pipe 'light grade' 40 mm in trenches, under floors, roads, along poles for protection of cables with all necessary fittings and sealing ends complete all as specified and directed.
Description same as per Item No. 06 above but GI pipe 'light grade' 80 mm complete all as specified and directed.
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for laying of cables, pipes etc. and getting out all excavated material in any type of soil complete all as specified and directed.
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing of excavated surplus soil to a distance not exc 50 m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
M&L of locally available river sand in trenches below and above / around UG cable for cable protection, in duct under & above the cables including punning around cable complete all as specified and directed. Note - Punned thickness shall only be measured and paid.
Supply and laying unreinforced PCC Cable protection cover, class LV, type-1 flat with size 250 x 150 x 40 mm laid flat width wise complete all as specified and directed.
Drilling (Horizontally) existing road (maximum 10 mtr wide) suitable for passing GI tubing complete all as specified and directed.
S&F in replacement of unserviceable Straight through LT joint including jointing material and excavation up to 3mtr length and make good surface after jointing of cable complete of size 50 to 120 sqmm 3.5 core complete all as specified and directed.
S&F Junction Box for street light made out of FRP sheet 3.0mm thick, dust and vermin proof out door type of size 350mm x 300mm x 150mm (HxWxD) with arrangement of incoming and outgoing feeder with 04 Nos Aluminium bus bar of 32 Amp for termination of line with and providing DIN Rail for mounting single MCB SP 230V. 6A 10 KA (in accordance with IS/IEC 60898-1) and making arrangement for fixing aluminium conductor of size 16 sqmm 4 core and copper wire of size 2 x1.5 sqmm with 1 x 1.5 sqmm earth wire in green wire of FRLS PVC insulated copper conductor from Junction Box to street light fitting and clamps made out of MS flat iron 25 X 4 mm ,MS hexagonal bolts, nuts and washer for arrangement to pole /surface complete all as specified and directed.
M&L for rigid non-metallic PVC FRLS conduit heavy duty of size 20 mm external dia, exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc, to be fixed along the pole and including taking down complete all as specified and directed.
M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to galvanised earth strip of size 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate no. 3 of SSR Part - 1, connected to earthing test point and complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) earth chamber, RCC 1:1.5:3, type A-1 cover slab, 40 mm thick reinforced with 6 mm dia TMT bar @ 150 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 15 mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
Supply , installation , testing and commissioning LT PANEL board outdoor type (CPRI Approved) of suitable size Kiosk type factory assembled fabricated and of suitable size angle iron, channel and MS sheet 3 to 3.15 mm thick (inner compartment is 2.0 mm thick) double door type, front and rear openable with locking arrangement and indepent duly prewired with colour code three phases and natural for 415 volts, 50 Hz electric supply with and including suitable sizes of cable glands for incoming and outgoing cables cubical type duly powder coated over a coat of primer, grouting of panel 60 cm above the ground level by provisioned 90 cm long angle iron frame bottom of panel 40 x 40 x 5 mm thick, welded on all four corners, embedded in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate up to 30 cm and grouting the panel board on and including suitable size foundation structure with the following components. (a) MCCB 250 Amps 4 pole, 25KA 415 volts, Ics =100 % Icu Adjustable short circuit setting type (incoming) – 01 Nos (b) MCCB 100 Amps 4 pole, 10 KA 415 Volts, Ics =100 % Icu Adjustable short circuit setting type (out going ) – 01 Nos (c) MCCB 63 Amps 4 pole,10 KA 415 Volts, Ics =100 % Icu Adjustable short circuit setting type (out going ) – 04 Nos (d) MCB TPN 63 Amps 3 phase and neutral - 02 Nos. (e) Aluminium Bus bar of capacity 600 Amps 3 phase and neutral -1 set. (f) Digital type voltmeter 0-500 volts. (g) Digital type Ammeter with CT of suitable ratio for reading up to 400 amps load-01 Nos (h) Indicating lamps R,Y& B -01 set
Supply , installation , testing and commissioning LT PANEL board outdoor type (CPRI Approved) of suitable size Kiosk type factory assembled fabricated and of suitable size angle iron, channel and MS sheet 3 to 3.15 mm thick (inner compartment is 2.0 mm thick) double door type, front and rear openable with locking arrangement and indepent duly prewired with colour code three phases and natural for 415 volts, 50 Hz electric supply with and including suitable sizes of cable glands for incoming and outgoing cables cubical type duly powder coated over a coat of primer, grouting of panel 60 cm above the ground level by provisioned 90 cm long angle iron frame bottom of panel 40 x 40 x 5 mm thick, welded on all four corners, embedded in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate up to 30 cm and grouting the panel board on and including suitable size foundation structure with the following components. (a) MCCB 200 Amps capacity 4 pole, 16 KA, 415 V Ics =100 % Icu Adjustable short circuit setting type ( incoming ) - 01 Nos. (b) MCCB 63 Amps capacity 4 pole, 10 KA, 415 V Ics =100 % Icu Adjustable short circuit setting type type ( outgoing) - 05 Nos. (c) MCB TPN 40 Amp - 04 Nos (d) Aluminium Bus bar of capacity 400 Amps 3 phase and neutral -1 set. (e) Digital type Ammeter with CT of suitable ratio for reading up to 400 amps load-01 Nos (f) Digital type voltmeter 0-500 volts. (g) Set of indicating lamp with toggle switch RYB -01 Set.
Supply , installation , testing and commissioning LT PANEL board outdoor type (CPRI Approved) of suitable size Kiosk type factory assembled fabricated and of suitable size angle iron, channel and MS sheet 3 to 3.15 mm thick (inner compartment is 2.0 mm thick) double door type, front and rear openable with locking arrangement and indepent duly prewired with colour code three phases and natural for 415 volts, 50 Hz electric supply with and including suitable sizes of cable glands for incoming and outgoing cables cubical type duly powder coated over a coat of primer, grouting of panel 60 cm above the ground level by provisioned 90 cm long angle iron frame bottom of panel 40 x 40 x 5 mm thick, welded on all four corners, embedded in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate up to 30 cm and grouting the panel board on and including suitable size foundation structure with the following components. (a) MCCB 160 Amps capacity 4 pole, 36 KA, 415 V Ics =100 % Icu Adjustable short circuit setting type ( incoming ) - 01 Nos. (b) MCCB 63 Amps capacity 4 pole, 16 KA, 415 V Ics =100 % Icu Adjustable short circuit setting type type ( outgoing) - 05 Nos. (c) MCB TPN 40 Amp 3 Phase and neutral - 02 Nos (d) Aluminium Bus bar of capacity 400 Amps 3 phase and neutral -1 set. (e) Digital type Ammeter with CT of suitable ratio for reading up to 400 amps load-01 Nos (f) Digital type voltmeter 0-500 volts. (g) Set of indicating lamp with toggle switch RYB -01 Set.
Supplying, fixing, testing and commissioning of outdoor type electronic based APFC Panel of capacity 100 KVAR comprising of heavy-duty capacitors and suitable capacity incomer MCCB and branch protection MCB with auto manual switching complete with following specifications: - (a) Power rating – 100 kVAr (b) Power supply – 3 phase 4 wire (c) Rated system voltage – 440 volts (d) Rated frequency – 50 Hz (e) Short circuit rating > 36 kA (f) Duty – continuous (g) Ambient temperature – 5 to 45 degree C (h) Relay current input signal – 600/5 A with 3 CT sensing (i) Capacitor rating – 12.5kVAR x 02 Nos, 10 kVAR x 02 Nos, 5 kVAR x 06 Nos, 3 kVAR x 05 Nos, 02 kVAR x 05 Nos (j) Enclosure – Load bearing structure, bottom, top, all three sides and front door made out of 3 to 3.15 mm thick CRCA sheet, the internal components are assembled on opening the front door. Ingress Protection – IP 65 (k) Capacitor – heavy duty cylindrical capacitors (MPPH) having life >= 2 lakh hours and switching operations >= 15000 (l) Switching device (contractor) – 3 pole MPX capacitor duty contractors of adequate rating for respective steps. (m) 3 CTs & Ratio 600/5 Amp.
Design, Supply, installation, testing and commissioning of bus bar chamber box of size 0.5Mx0.8Mx0.60M depth,(HxBxD) outdoor type factory fabricated made out of CRCA sheet of 3 to 3.15 mm thick, fully enclosed and angle iron frame of size 40 x 40 x 6mm thick and T section with front and rear openable double door shutter, dust and vermin proof and rear opening complete with locking arrangement, having a system of bus bars of aluminium of suitable size of 200 Amps duly insulated and mounted on Epoxy/porcelain insulators in totally enclosed chamber with 160 Amp MCCB three phase and neutral arrangement 415 volts, AC, system, provn of suitable cable glands, duly powder coated and provn of digital time switch (programmable every 1 min, with backup of 06 yrs, 28 memory locations, current capacity 16 Amps, weekly program, with 1 changeover (1CO) total 28 programs) complete all as specified and directed by Engr -in charge.
Vinayak Trading House
AGARWAL BUILDERS
Ms Kailash Chandra Babulal
ENVIRO TECH SERVICES
SUNIL ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .