Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.1 LAccepted-AOC | L1 | Accepted-AOC L1 |
Tender Value
₹19.7 L
EMD Value
₹39,500
Closing Date
30 May 2022, 5:00 pmClosed
R.Nagender Singh
XEN(E)
Construction of Govt. Unani College and Hospital at Village Akera in Nuh District (Pdg. Fire Alarm system only in Hospital building)
2022_HRY_214578_2
PWD/HRY/MAR-008
Open Tender
Electrical Works
Works
90 days
XEN(E)
Refer DNIT
2 documents required · 2 mandatory
₹1,000
₹39,500
22 Dec 2023
20 May 2022
31 May 2022
20 May 2022
30 May 2022
20 May 2022
Amount
SITC of Micro processor based 2 wire fault tolerant, networkable type fire alarm/ detection control panel having no. of 4 loops to suit minimum 20% extra over the no. of fire detectors. The panel shall be able to give location of all fire/ fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/ OFF respective control module when ever any fire alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 character LCD units / 5.7” TFT to indicate Fire/ fault signal with address analog input, external / inbuilt printer to log all fire or fault events complete in all respects. The panel shall be sheet steel power coated, sealed to IP30. The panel shall have 20 zones with individual LED indicators, expandable 80 LED indicators. The Panel shall have 3 Serial Ports. The panel shall have built in power supply and battery charger along with maintenance free 24 AH.2 X 12 volt SMF lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required and confirming BS5839 standards and duly approved by EN 54/UL/VDS as per specifications complete in all respect up to the entire satisfaction of Engineer-in-charge of work Makes:- BOSCH FPA 4000 series, Fire Finder by Siemens, Edwards EST3, Honeywell Morley DXE Series
Supplying, installation, testing & commissioning of intelligent analog addressable photoelectric detector complete with mounting base complete as required. Approved by EN 54/UL/VDS/ as per specifications complete in all respect up to the entire satisfaction of Engineer-in – charge of work. (Detectors without in built isolators may be considered with an additional isolator Module after 20 devices) (Makes: Bosch FAP-440-T-FAA-440, Siemens, Cerberus OH921-DB-11, Honeywell Morley HM-PTSE+B501, Edwards, SIGA PHD-SIGA
Supplying, installation, testing & commissioning of intelligent analog addressable thermal detector complete with mounting base complete as required. Approved by EN 54/UL/VDS/ as per specifications complete in all respect up to the entire satisfaction of Engineer-in – charge of work. (Detectors without in built isolators may be considered with an additional isolator module as per detector) (Make:- BOSCH FAG-440+FAA-440, Siemens Cerberus H1921+B-11, Honeywell Morley HM-RHSE+B501, Edwards SIGA DH1 + SIGA.
Supply Installation Testing Commissioning of UL/EN54/LPCB listed and FM approved line isloating for isolation the section of circuit in case of short in the addressable loop wiring (Make: Bosch / Siemens Cerberus/ Morley / Edwards.
SITC of intelligent analog addressable type Manual Call point having surface or flush mounting option fully compliant to EN54 having rotary decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect upto the entire satisfaction of Engineer-in-Chage of the work. Make Siemens cerberus/ Morely/ Edwards.
SITC of Intelligent Analog Addressable type Response Indicator with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work Make Siemens cerberus/ Morely/ Edwards.
SITC of Addressable Loop powered sounder complete with mounting base as required performing to BS5839 standards and duly approved by EN54/DU/VDS required to complete the job in all respect up to the entire satisfaction of Engineer-in-charge of work Make:- BOSCH/ Siemens/ Cerberus/Morley/Edwards.
SITC of Addressable control relay module with flexible network structure with a maximum switching current of 1A @ 30V DC shall be EN54/UL/VDS certification Make BOSCH, Siemens/ Cerberus/ Morley/ Edwards.
SITC of addressable monitor module for monitoring of a line with EOL resistor/ Potential free contact/ voltage monitoring shall be EN54/UL/VDS approved (In case of 2 Monitoring features in one module (points) each point shall be consider separately for payment) Makes: BOSCH FLM-325-214, Simens, Cerberus HTRI-M, Morley MI-DMMI, Edwards EST 3.
SITC of minimum 1000 mtr. range Siren generator provided at the proof of the building with separator power supply relay etc. with all accessories required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work Make:- National/ Kheraj
Supply and erection of 2core 1.5sqmm copper cable with all accessories required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work Make:- Havells/ Finolex/RR Kabel
HSR 23.1.6.6Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required2 run of Size 1.50 Sqmm(1/1.40mm)
HSR 23.7.6Supply and erection of PVC CONDUIT ISi marked (Medium) recessed in walVceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of workPVC pipe of 25 mm dia
PVC pipe of 32 mm dia
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .