| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 LAccepted-AOC 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 | SANGRUR | PUNJAB | 148001 | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹10.0 L+₹8,976.67 (0.91%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹12.4 L+₹2.5 L (25.2%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹13.2 L+₹3.3 L (33.7%)Rejected-Finance SECTOR 10 PANCHKULA | PANCHKULA | PANCHKULA | HARYANA | L4 | Rejected-Finance Being L4 |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
27 Aug 2022, 6:00 pmClosed
Sh Himanshu, IDSE
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH TARAPORE ENCLAVE PATIALA CANTT
As per tender documents
2022_MES_531980_2
GE(S)/PAT/T-17/N/2022-23
Open Tender
Civil Works
Item Rate
180 days
Mil Stn Nabha
Refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (South) Patiala
₹20,000
Yes
23 Sept 2022
6 Aug 2022
29 Aug 2022
6 Aug 2022
27 Aug 2022
13 Aug 2022
Amount
Excavation in trenches in soft soil not exceeding 1.50 metre wide & not exceeding 1.50 metre deep for foundation ,for laying of water supply pipe line in trenches and getting out including dressing/trimming sides and levelling, grading and ramming of bottom of excavation complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, excavated soil in trenches after pipes have been laid and tested, complete all as specified and directed.
Removing excavated surplus spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
Cutting of road /PCC path upto the depth of pipe & making good the disturbed surface with PCC 1:2:4 (20 mm aggregate) using extra cement including earth work complete all as specified and directed.
Taking up or down old rusted steel water GI tubing, 80 mm bore including fitting connections and cleaning tubing, fitting/ cutting threading of serviceable tubing for relaying and removal of unserviceable tubing all as directed by Engr-In- Charge.
All as per serial item no 5 but 50 mm bore
All as per serial item no 5 but 40 mm bore
All as per serial item no 5 but 25 mm bore
All as per serial item no 5 but 20 mm bore
All as per serial item no 5 but 15 mm bore
S & F Steel water tubing, 80 mm bore, medium grade, galvanised with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed.
All as per serial item no 11 but 50 mm bore
All as per serial item no 11 but 40 mm bore
All as per serial item no 11 but 25 mm bore
All as per serial item no 11 but 20 mm bore
All as per serial item no 11 but 15 mm bore
Fixing/laying only water tubing 80mm bore fixed to walls and ceiling or laying in floors including cleaning the old pipe for reuse, with new fittings & fixtures to make it functional complete all as specified and directed. (Excavation, earth work, joints, threading & CI specials shall be measured and paid separately). Note : Old serviceable tubing as retreived under item No.5 shall be re-used under this item.
All as per serial item no. 17 but 50mm bore Note : Old serviceable tubing as retreived under item No.6 shall be re-used under this item.
All as per serial item no. 17 but 40mm bore Note : Old serviceable tubing as retreived under item No.7 shall be re-used under this item.
All as per serial item no. 17 but 25mm bore Note : Old serviceable tubing as retreived under item No.8 shall be re-used under this item.
All as per serial item no. 17 but 20mm bore Note : Old serviceable tubing as retreived under item No.9 shall be re-used under this item.
All as per serial item no. 17 but 15mm bore Note : Old serviceable tubing as retreived under item No.10 shall be re-used under this item.
Supply testing and commissioning of gun metal glove or gate valve heavy duty ISI marked class-1 with iron wheel head, screwed both ends for iron pipe of following bore complete fixed as in repairs. Note: In case short length of GI tubing/nipple is required to fix the valve, it shall be measured & paid under item No. 12 here-in-before. Pipe of 15mm bore
Pipe of 20mm bore
Pipe of 25mm bore
Pipe of 40mm bore
Pipe of 50mm bore
Taking up/out old rusted GI/CI/Ductile Iron water mains including all fittings with spigot and socketed ends or flanged ends including burning out lead joints or dismantling flanged joints for pipe of following bore complete all as specified and directed. Note: (i) Excavation and earth work shall be measured and paid separately. Pipe of 100mm bore
Pipe of 150mm bore
S&F Ductile iron water pipes class K-7 conforming to IS-8329, in any length including jointing with push on rubber tyton joints, as in trenches of following bore in new or old locations of following sizes. (Excavation, earth work & DI specials shall be measured and paid separately. However, the rate of Rubber tyton joints shall be included in the unit rate quoted). 100mm bore complete all as specified and directed.
150mm bore complete all as specified and directed.
Laying, jointing and testing serviceable GI/CI/DI pipes with flanged end or spigot and socketed ends as retrieved vide item No. 24.00 here-in-before in any length including cleaning, cutting for reducing length as required, jointing as in trenches for following bore in new or old locations. (Excavation, earth work, joints, threading & CI specials shall be measured and paid separately). Pipe of 100mm bore
All as per Item Sr No. 26 but Pipe of 150mm bore retrieved vide item No 24.01 here-in-before.
Cast iron fittings of size upto 100/150 mm bore for spigot and socketed pipes e.g. Bends (any type, radius and angle). Tapers any type (Straight, end, increasing, decreasing or double socket etc). Tee pieces single branch, 'Y' junctions double branches, crosses (all sockets or socket and spigot) collars caps and plugs conforming to Is complete all as specified and directed. (Excavation, earth work, & joints shall be measured and paid separately).
All as per Item Sr No. 27 but Ductile iron fittings suitable for DI pipes complete all as specified and directed.
Cutting existing cast iron pipe of following bore of any description for insertion of fittings and setting the pipe in proper alignment complete all as specified and directed. (Excavation earth work and fittings shall be measured and separately). Pipe of 80 mm bore
Pipe of 100mm bore
Pipe of 150mm bore
Construction of brick masonary valve pit of size 120 x 120 x 120 cm (Internal dimension) incl necessary earth work, PCC foundation 1:3:6 a type C-1 and MS sheet 3 mm thick cover with angle iron frame 40 x 40 x 6mm including provision of suitable hold fasts to hold the frame, locking arrangement and lifting handle, duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified directed
All as per serial item No. 30 but pit size 90x90x90
All as per serial item No. 30 but pit size 60x60x90
S&F in replacement, Cast iron sluice valve, 150mm dia conformig to IS - 14846, PN 1.6, clockwise dosing with flanged ends and iron wheel including necessary joints by means of bolts, nuts washers and rubber gaskets complete including taking down old unserviceable sluice valve all as specified and directed.
All as per serial item No 33 but of 100 mm dia.
All as per serial item No 33 but of 80 mm dia.
Repair to sluice valve installed at existing line of following bore by opening up, necessary repair comprising replacement of glands, gland packing, gaskets, facing the gate & valve seat, replacement of nut bolts, re-assembling and fixing in position & testing complete all as directed. Note: -(i) Necessary arrangements for regulating the water supply in line for the purpose of repair shall be made by contractor at his own expenses. (ii) MS Spindle shall be measured and paid separately in the under mentioned item. Pipe of 100mm bore
Pipe of 150mm bore
Supply and replace MS Spindle complete all as specified and directed. Pipe of 100mm bore
Pipe of 150mm bore
Disamantling joints of flanged pipes in position including removing old rubber fiber board gasket bolts , nuts etc bore of pipes in 150/100/80 mm dia and reassembling of joints of flanged pipes in position with new ribber or fiber board gasket bolts nuts & washers all as directed. Note :- Excavation if required shall be measured and paid under respective item of Sch.
Supply & fixing gland packing fiber board gasket for sluice valve of 150 / 100mm/80 mm dia including taking down of old gland packing all as specified & directed
Taking out unserviceable wheel shaft of cast iron sluice valve from pit /column pipe of 150 /100/80 mm dia & carrying to the workshop for cutting, threading, grinding etc & refixing the same after repair complete all as specified & directed by Engineer-in-charge.
M&L for Drilling and tapping of GI/ CI/DI water line for branch connection of 15 mm to 50mm pipe with clamp & connected accessories complete all as specified & directed.
Cleaning and disinfection of entire internal surfaces of chamber of RCC overhead reservoir both compartment of capacity One Lakh gallon at 70 to 80 ft staging at Nabha Military Station including all required T & P and manpower comprising of the following processes. (a) Draining out water and evacuation of internal surfaces including floor and ceiling with mechanical pressure machine by applying solution of H2 02 (Hydrogen per Oxide) in the ratio of 1: 100 (1 LT of H202 and 100 Ltr of water). (b) Disludging the dirt layers with high speed water jet including scrapping the surface with wire brush and draining out the sludge water. (c) Cleaning the internal surfaces complete with Mechanical Scrubber and washing the surfaces with high-pressure water jet. (d) Filling the chambers with clear water and washing out prior to reuse after complete process. (e) Writing on the surface of tank date of cleaning as specified and as directed
Taking down old unserviceable non return valve of 150 mm dia from existing position and supply & fixing cast Iron non return valve of 150 mm dia conforming to IS 14846 with flanged ends including necessary joints by means of bolts and nuts washers and rubber gasket complete all as specified & directed. .
Supply only sodium hypochlorite solution as per the specifications of IS-11673 Gde 1st and as directed by the Engr-in-Charge complete all as specified and directed. Liquid solution should be supplied in PVC Container.
Detecting the leakage from underground CI/DI pipe 150 mm bore and rectifying the leakage by burrning out existing lead and redoing the joint by adding extra lead if required complete all as directed.
Detecting the leakage from underground GI/CI/DI pipe 100 mm bore and rectifying the leakage by threading/burrning out existing lead and redoing the joint by adding extra lead if required complete all as directed.
Detecting the leakage from underground GI/CI/DI pipe 80 mm bore and rectifying the leakage by burrning out existing lead/ threading and redoing the joint by adding extra lead/extra length of pipe if required complete all as directed.
Detecting the leakage from underground GI pipe 15 to 50 mm bore and rectifying the leakage by cutting/treading/adding extra length (up to 1 RM only) of pipe if required complete all as directed.
M&L for painting steel or iron surface of any description wih two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L in replacement of Old Unsv MS sheet pit cover of 3.15 mm thick along with angle iron frame,locking arrangements and necessay civil works including taking up old iron cover complete all as specified and directed.
Supply connecting and testing and comissioning complete in replacement of existing unserviceable electric cable PVC insulated and PVC sheathed water proof 3 phase 3 core AC 1100 volts grade 16 sqmm starnded flat copper conductor suitable for submersible pump including making connection to pump set as well as to control panel complete including taking out old cable all as directed
M&L for carrying out repairs to submersible pump of capacity upto 40 HP after dismantling the assembly complete for replacement of worn out spares such as stage bowls, impellers, pump shaft, sleeves, bushes etc with and incl filling, turning & polishing work to pump shaft, gun metal impellers as necessitated and re-assembling the pump after repairs incl applying a coat of water proof epoxy paint to the external surfaces of pump and testing complete all as specified and directed :- Note: Any spares required to be replaced will be measured and paid separately under respective item of Schedule ‘A’ Note : (A) Lifting up submersible pump set of any capacity along with MS column flanged pipe 125/150 mm dia bore and submersible cable 3 core of size upto 25 Sqmm from existing bore well at different loaction including dismantelling cable connection etc complete all as specified and directed upto 35 mtr depth. (b) Submersible cable, column pipe to be stacked in suitable place at pump house for checking/inspection cleaning properly. (c) All T & P and transportation charges to and fro Nabha mil stn to workshop shall be deemed included in the qouted rate. (d) Lowering of submersible pump set after repair alongwith MS column pipe 150 mm dia, making flanged joints , cable connection to submersible pump complete all as specified and directed depth upto 35 mtr.
M&L for rewinding of submersible motors AC, 3 phase, 440 Volts,upto 40 HP capacity, 75 Mtr head, with PVC insulated copper submersible winding wire of identical gauge and specification of the existing winding wires with all necessary insulating materials including cleaning of stator and slots and applying a coat of water proof epoxy paint to the exterior surfaces of motor and testing on load complete all as specified and directed. Note: Any spares other than specified in the above item will be measured and paid separately under respective item of Schedule ‘A’.
Supply only Motor bush upper and lower suitable for submersible Motor complete all as specified and directed.
Supply only Rotor bearing sleeves upper and lower of existing description & make suitable for submersible motor of any size / capacity complete all as specified and directed.
Supply only Motor thrust bearing assembly complete of existing description & make suitable for submersible pump of 40 HP capacity.
Supply only Gun metal impellers with key and bushes suitable for 22000 GPH complete all as specified and directed.
Supply only Pump shaft stainless steel suitable for 22000 GPH complete all as specified and directed.
Supply only Bearing bush of existing description suitable for submersible pump of 22000 GPH complete all as specified and directed.
Supply only Cast iron bowl assembly complete with stage bolts suitable for submersible pump 22000 GPH complete all as specified and directed.
Supply only Neck rings for 22000 GPH submersible pump of any capacity complete all as specified complete all as specified and directed.
S&F Automatic star delta starter panel moounting type complete3 phase 415 volt upto 40 HP capacity complete fixed as in repair all as specified directed.
Taking down centrifugal pump set of 10 HP from foundation after unscrewing nuts/bolts,inlet-out flanged pipes from floor of room and providing PCC 1:2:4 for platform of suitable size with thickness 10 cm for grouting of pump motor incl plastering work & re-fixing the same on the platform with new heavy duty nut, bolts & washers complete all as directed by engr-in-charge. Note :- Vol of PCC will be measured under relavent item of schedule.
Taking down centrifugal pump set of 10 HP from foundation after unscrewing nuts/bolts,inlet-out flanged pipes and carrying to workshop for repairs and reassembling after necessary repairs which shall include following elements- (1) Disconnecting the pump from motor after unscrewing the coupling nuts/bolts (2) Strip opening the pump for segregation of unserviceable parts. (3) Necessary lathe work for repair to pump.(4) reassembling the pump and reinstallation in the installation including necessary transportation. (5) Paint to pump with one coat of synthetic enameled paint matching with existing colour of motor. NOTE: (i) Any spare part to be replaced shall be measured and paid seperately under respective item of this sch here-in-after, complete all as specified and directed. (ii) All T & P and transportation charges to and fro Nabha mil stn to workshop shall be deemed included in the qouted rate.
Rewinding of 10 HP motor stator with existing size and gauge of super enameled copper winding wire and insulating material compleyte all as specified and directed.
Supply only gun metal bush matching with the size of shaft as per sample complete all as specified and directed.
Supply only stainless steel shaft to match the existing manufacturers design complete all as specified and directed.
S&F Automatic star delta starter wall mounting type 3 phase 415 volt suitablefor 10 HP pump motor complete fixed as in repair all as specified directed.
S&F Pressure Gauge (burdon type) suitable for mounting on 150 mm CI Water supply mains, capacity 0-21 kg / cm , including U bend, GI Pipe and Brass valve arrangement along with pipe fitting complete in all respect.
Dismantling of star delta motor starter, M&L for repair of 3 phase 415 volts star Delta starter of 10 HP pump motor including replacment of unsv parts etc and refixing the same after repairs incl testing all as directed by Engr-in-Charge.
S&F MCCB, 63/100 Amps 4 pole, with adjustable thermal magnetic setting, 415 volt breaking capacity 25 KA including taking down the old one, complete all as specified and directed.
S&F brass tap of 15 mm dia including fittings such as socket,nipple ,elbow as well as taking down unserviceable tap, complete all as specified and directed.
Repair to existing GI pipe 20/25mm by providing GI fittings i.e Elbow, Nipple, Union socket, Tee, Reducer socket etc. as per site requirement including cutting, threading, inserting necessary fittings for jointing existing pipe complete to ensure the joints leak proof for 20/25mm bore pipe, including removing of existing unserviceable pipe to MES store yard, complete all as specified and directed. Note:- (i) These jobs are meant for rectification of leakage / blockage in existing distribution network. (ii) Unit rate quoted against this item includes for necessary excavation & earth work all as directed. (iii) During repair it may necessitated the involvement of bailing out water and work as in mud/wet conditions, so contractor shall arrange all necessary arrangements to avoid stagnation/pending of water in nearby area. Unit rate quoted against this item deemed to be included for all such expences. (iv) Taking down & refixing existing GI pipe for replacement of defective GI fittings is the part of the Job. New GI pipe upto 1 metre wherever required during rectification is the part of the Job. The rate deemed to be included in the quoted rate against this item.
All as per item No. 73 here-in-before but Pipe of 40/50 mm bore
Replacement of defective unserviceable 'D' joints , clamps, sockets etc for CI pipe 100/80 mm dia including cutting /threading and other allied work including earth work complete all as directed.
S&F fixing cast iron pipe with flanged end centrifugally casted class LA in any length 150 mm bore in rising/supply main of O/H reservoir with rubber gasket, nuts & bolts with washers complete including required T&P. NOTE:- (i) The required castigating Scaffolding upto the height of 25 mtrs for opening and fixing of CI Pipe of OH reservoir, Chain pulley Assy, Lifting Jack for holding vertical pipe and other misc T&P items shall be arrangement of the contractor and the cost thereof shall be included in the unit rate quoted.
S&F Change over switch 100 Amps 415 volts, fixed as in replacement of old unserviceable switch, complete all as specified and directed.
S&F in replacement PVC Bib Tap size 20 mm bore dia of pipes standard PTMT and colour high pressure screwed for iron pipe and fixed with nipple/ elbow and socket if required all as specified and directed.
S&F Water Dosing Pump 240 volts of pdosing/pumping capacity 40 Ltr/Hour including connecting to the existing PVC tank complete commissioning & testing all as specified and directed
S&F Water Level indicator system for OH tank (50 ft height) including connecting cable/wire from OH Tank to Duty room (approx distance 180 ft ) all as specified & directed by Engr-in-Charge.
Dismantling unsv Air Release Valve, S & F air relaese valve suitable for 150 mm water supply mains incl fixing on CI pipe line & testing all as directed by Engr-in-Charge.
S&F PVC Foot Valve heavy duty ISI Mark suitable for 100 mm GI Pipe Line.
R D Bansal
m/s panchmukhi builders
M/s Friends Engineering Works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .