Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹5.0 LAccepted-Finance 1 3104 KUNJ GALI RAM NAGAR EXTN LONI ROAD SHAHDARA DELHI 32 | SHAHDARA | DELHI | 110032 | L-1 | Accepted-Finance L1 accepted | |
| 2 | L-2₹5.4 L+₹36,346 (7.28%)Rejected-Finance 256 MUNDHELA KHURD NEW DELHI 73 | WEST | DELHI | 110008 | L-2 | Rejected-Finance L2 rejected | |
| 3 | L-3₹5.6 L+₹57,316 (11.5%)Rejected-Finance | L-3 | Rejected-Finance L3 rejected |
Tender Value
₹6.6 L
EMD Value
₹13,120
Closing Date
13 Jul 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Ex. Engineer (Elect)-II
OFFICE OF THE Ex. ENGINEER (ELECT)-II, SHAHDARA (N) ZONE, Keshav Chowk, Delhi-110053
Improvement and Development of Electrical Intallation at TB and Chest Clinic Building, Ramp and Flood Lights in VSAS Karawal Nagar in Ward No. 242 Under Shahdara (North) Zone
2023_MCD_160298_1
EE(E)-II/SNZ/MCD/23-24/TC-5/3
Open Tender
Electrical Works
Item Rate
90 days
As per NIT
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
₹13,120
8 Aug 2023
7 Jul 2023
14 Jul 2023
7 Jul 2023
13 Jul 2023
7 Jul 2023
Amount
OD3254/2023-2024:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular type switch, modular plate, suitable GI Box,earthing the point with 1.5 sq mm FRLS PVC insulated copper insulated copper conductor single core cable etc as required Group B
OD3256/2023-2024:Rewiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable and 1.5 sq mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel conduit inculding dismantling as required Group B
OD3257/2023-2024:Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. (i) 6 module( 200 mmx 75 mm)
OD3258/2023-2024:Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. (ii) 8 module( 125 mmx 125 mm)
OD3259/2023-2024:Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. (iii) 12 module( 200 mmx 150 mm)
OD3260/2023-2024:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (a) 5/6 amp switch
OD3261/2023-2024:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (b) 3 Pin 5/6 Amp socket outlet
OD3262/2023-2024:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
OD3263/2023-2024:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required
OD3264/2023-2024:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required (a) 3x2.5 sq.mm
OD3265/2023-2024:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required (b) 3x6 sq.mm
OD3266/2023-2024:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required (c) 3x4 sq.mm
OD3267/2023-2024:Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. ( a) 25 mm
OD3268/2023-2024:Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. ( b) 32 mm
OD3269/2023-2024:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps
OD3270/2023-2024:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single Pole
OD3271/2023-2024:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
OD3272/2023-2024:Supply and fixing extra conduit down rod of 20 cm length GI pipe 15 mm dia heavy gauge including painting etc as required(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
OD3273/2023-2024:Supplying and fiixing following way, horizontal type three pole and neutral sheet steel MCB distribution noard 415V on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted inculding eatrhing etc. as required (But without MCB/RCCB/ISOLATOR) (a) 4 Way (4+12 ), double door
OD3275/2023-2024:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way double door
OD3276/2023-2024:Providing and fixing following capacity MCCB disconnector fuse switch unit inside the existing cubicle panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 100A,16KA,TPMCCB
OD3277/2023-2024:Providing and fixing following capacity MCCB disconnector fuse switch unit inside the existing cubicle panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 150A,16KA,TPMCCB
OD3278/2023-2024:Providing and fixing following capacity MCCB disconnector fuse switch unit inside the existing cubicle panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 250A,25KA,TPMCCB
OD3281/2023-2024:supply, installation, Testing and commissioning of 1200mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Currect (BLDC) Motor, class of insulation:B, 3 nos blades, 30 cm down rod, 2 nos. canopies, shackle kit, safety ropr, copper winding, power factor not less than 0.9, service value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, Earthng etc. complete as required.
AR items
122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm
122.1.2:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm
122.2.2: P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.
122.2.30.a:SITC of 150W LED Flood Light luminaire fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =150 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
OD3280/2023-2024:Supply and fabrication of pole protection system made up 8SWG steel wire mesh of size 25mmX75mm recangular with 50mmx50mmx6mm MS angle iron for supporting the mesh i/c MV danger plate and grounding the protection system to suitable quality of CC etc.
M/s New Gupta Electric Works
AMIT ELEVATOR SERVICES
Bidder Name
M/s New Gupta Electric Works
AMIT ELEVATOR SERVICES
G D Electricals
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .