| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹39.2 LQualified Make: Orion
Model: ORION & Mod5T 4 R G BARUAH ROAD SUNDARPUR GUWAHATI KAMRUP ASSAM 781005 | KAMRUP METRO | ASSAM | 781005 | Make: Orion
Model: ORION & Mod5T | L1 | Qualified MSE, Category: General | |
| 2 | L2₹58.8 L+₹19.5 L (49.7%)Qualified Make: Delta
Model: DELTA DPH 500 B 42 BHIKAJI CAMA PLACE BHIKAJI CAMA PLACE SOUTH DELHI DELHI 110066 INDIA | NEW DELHI | DELHI | 110066 | Make: Delta
Model: DELTA DPH 500 | L2 | Qualified MSE, Category: General | |
| 3 | L3₹58.8 L+₹19.5 L (49.8%)Qualified Make: Delta
Model: DPH 300 A 16 BASEMENT JANGPURA EXTENSION DELHI DELHI 110014 | SOUTH EAST DELHI | DELHI | 110014 | Make: Delta
Model: DPH 300 | L3 | Qualified MSE, Category: General | |
| 4 | L4₹60.9 L+₹21.7 L (55.2%)Qualified Make: EATON MODULAR UPS
Model: 250 KVA Cabinet(150 kVA Modular UPS(N+1)(25 KVA(6+1) including construction of Chemical Earthing with copper strip, I/O Cu Cabling) C 2 SOAMI NAGAR SOUTH DELHI NEW DELHI DELHI 110017 | SOUTH DELHI | DELHI | 110017 | Make: EATON MODULAR UPS
Model: 250 KVA Cabinet(150 kVA Modular UPS(N+1)(25 KVA(6+1) including construction of Chemical Earthing with copper strip, I/O Cu Cabling) | L4 | Qualified | |
| 5 | L5₹79.8 L+₹40.6 L (103.3%)Qualified Make: APC
Model: APC by Schneider Electric - Symmetra PX 250 KW 309 SKYLARK BUILDING 309 SKYLARK BUILDING 60 NEHRU PLACE NEW DELHI NEW DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | Make: APC
Model: APC by Schneider Electric - Symmetra PX 250 KW | L5 | Qualified |
Tender Value
Refer Docs
EMD Value
₹1.9 L
Closing Date
22 Oct 2018, 12:00 pmClosed
Online UPS Modular Type Average Turn Over of Last 3 Years 150 Lakh (s) Experience with Gov. Required 5 Year (s) Online UPS Modular Type ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Online UPS Modular type should supoort for Data Centres
Network operating centres
Security operation centres
State and District centres
Command and Control centre etc.
across the Country to provide impetus to the e- Governnance services e.g.Public food distribution
e Way bill
Counseling
e-Office
IVFRT etc.
services under Digital India Programme Yes * Modular type UPS equipped with Yes * 1/9 microprocessor/Digital signal processor and power modules
Power expansion facility
LCD/Digital display upto maximum expandable capcity
Cable entry
RS 232 port and SNMP port with each power module and with suitabale rack (compatible maximum expandable) with complete lockable door having visibility for maximum expandable capacity Output power capacity including re dudancy/Expandable (Rack facility) upto/Minimum backuptime (including redudancy) Minimum VAH (VAH shall be calculate Battery voltage x Battery Ah x No. of batteries = Total VAH) 150 KVA/250KVA/30 Minutes/123000 VAH * VAH tolerance -1% of the defined capacity * Hot swappable power module Yes * Battery module using two or more strings in parallel for redudanct supply and battery module shall be fuse protected Yes * Inverter Technology PWM with IGBT
double conversion * Output wave form Pure sine wave * Country of origin for Inverter India * Noise level </= 65 dB </= 55 dB
</= 65 dB
</= 70 dB Type of cool (Minumum 2 Fans for each power module) Air cooled * 2/9 Parallel (Power Modules) load sharing redundant operation with all accessories Yes * Installation and commissioning Yes * UPS shall be supply with insallation and operation manual Yes * INPUT Input AC Three Phase * In put Voltage Range 320 V to AC to 470 V AC 3 Phase 320 V to AC to 470 V AC 3 Phase
340 V to AC to 470 V AC 3 Phase Input frequency range 50 +/-6% Hz * Input power factor at full output load leading to unity with active power factor correction (APFC) (from 25% load to 100% load) >/=0.99 * Distortion (current) </= 3% </= 3%
</= 5% UPS shall have DG set compatibility Yes * OUTPUT Output AC Three Phase * Out put voltage 380/400/415
3 phase
4 wire * Voltage regulation (Steady state) at No load to full load
0.6 lag to Unity PF
During entire back up time
Complete input voltage range +/-1% * Output powr factor >/= 0.90 * Frequency 50 Hz +/-0.5 % Hz * CONSTRUCTION Minimum thickness (in mm) of Rack Enclosure for Modular UPS duly powder coated 1.2 2.0
1.2 UPS shall be free from workmanship defects
sharp edges
nicks
scratches
burst
etc. All fasteners shall be fixed properly. The equipment shall be complete with all parts and all parts shall be Yes * 3/9 functional UPS enclosure's degree of protection as per IS:13947 (Part 1)/1993 latest IP20 IP21
IP20 Standard quality Out put terminals shall be provided for output connection Yes * UPS shall have static and manual by pass facility Yes * UPS shall be supplied with required rated power cable (Copper) 5 Meters * Total Harmonic Distrotion (THD) for 100% linear load < 3% < 3%
< 2% Total Harmonic Distrotion (THD) for 100% non-linear load < 4% < 5%
< 4% Operating temeprature 0 deg C to +40 deg C * Humidity Upto 95% non- condensing * Operational: 1000 meters above sea level at 40 deg. C maximum Yes * Crest factor on full non- linear load Not less than 3:1 * Over all efficiency on rated full load of 0.8 PF (min.) AC output >/=90% * Inverter efficiency on rated full load of 0.8 PF (min.) AC output >/=95% * UPS shall withstand Over load capacity - 125% (Output with mains AC-AC) for 5 Minutes (Minimum) * UPS shall withstand Over load capacity - 150% (Output with mains AC-AC) for 60 seconds (Minimum) * UPS shall withstand Over load capacity - 125% (Output in battery run DC-AC) for 2 Minutes (Minimum) * UPS shall withstand Over load capacity - for 30 seconds (Minimum) * 4/9 150% (Output in battery run DC-AC) Load power factor 0.8 lagging to unity Yes * Transient response time (for 100% load change
output must remain within +/-1% and recovery) <20 milli seconds * PROTECTION Short circuit protection Yes * Over load protection Yes * Over temperature protection Yes * In put low/high voltage control Yes * DC low/high voltage trip Yes * Back feed protection for both
mains and bypass input Yes * BATTERY Battery shall conforming to JISC:8702(Pt.I
II&III) latest or equivalent BIS standard Yes * Battery type SMF VRLA * Country of origin for Battery India * Battery recharge time (after complete discharge to 90% charge) and charge rating: Battery recharge time to 90% charge after 100% DoD 8 to 10 hours * Battery charger (One in each power module) should be capable to charge battery on C10 rating Yes * Battery cutoff voltage during back up Not less than 10.5 V * Batteries shall supply with With metal rack * Modular UPS shall supply with DC Cable from UPS to battery and batteries to UPS
Battery interlink cables
Yes * 5/9 battery breaker Meters
Indicators and Display All the meters and display LCD/Digital type shall support for maximum expanadable capacity Yes * Input: Voltage line to line and line to neutral
currents
frequency
power factor display Yes * Bypass: Phase voltage
line to line voltge
frequency display Yes * UPS Output: Phase voltage
phase currents
line-line voltage
power factors
frequency display Yes * Local load: Load of each phase (% age of total load)
Active power (KW)
Apparent power (KVA)
and Ractive power (KVAR) of each phase
load crest factor display Yes * Battery: Battery bus voltage
battery charge and discharge current
forecasted battery back up time
battery capacity (Ah) Yes * Parrallel load (for parallel operation system): Apparent power (KVA) of each phase
Active power (KW) of each phase
reactive power (KVAR) of each phase Yes * UPS shall have an indication for Mains on
Load on battery
Inverter
Battery level
Load level
Inverter over load Yes * UPS shall have audible alaram for over temperature
mains failure
battery low
inverter overload Yes * Communication Yes * 6/9 interface: SNMP/MODB US/HTTP/JAVA/UPSMON SMTP etc.
and 2 serial port USB/RS232
RS485
1 logic level port
4 Dry contacts ports Log History storage facility with display (minium 200 events) Yes * WARRANTY AND SERVICES Warranty for Modular UPS (on site comprehensive warranty) (in years) 5 3
5 Warranty for battery (replacement warranty) (in years) 5 2
3
5 After sales and complaint service within 24 hours within 24 hours
within 48 hours
Within 7 days PAN India service support on 24 x 7 basis Yes Yes
No AMC support available after 3 year warranty Yes Yes
No Quarterly preventive maintenance Yes Yes
No Manufacturer shall provide and support for installation
commissioning
spares
technical support all over India Yes Yes
No Availability of spares in close proximity (Spares should be easily available close to the site) Yes Yes
No CERTIFICATIONS ISO: 9001 Certification Yes * ISO: 14001 Certification Yes * Environmental compliance certificate RoHS Yes * CE Certification and marking Yes Yes
No UPS shall meet and comply with the General and safety Yes * 7/9 requirements as per IEC:62040-1 UPS shall meet and comply with the Electromagnetic compatibility (EMC) requirements as per IEC:62040-2 Yes * Damp Heat Test : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C
two cycles of (12+12) hours each 2007) Yes Yes
No Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes Yes
No Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes Yes
No Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * All the test reports and certificates shall furnish by the supplier to the buyer/consignee on demand Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ravindra Kumar Pandey 110003
NATIONAL INVESTIGATION AGENCY
OPPOSITE CGO COMPLEX
LODHI ROAD
NEW DELHI 1 45 8/9
686043
GEM/2018/B/97147
Online UPS Modular Type
45 days
Delhi; New Delhi
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Online UPS Modular Type Average Turn Over of Last 3 Years 150 Lakh (s) Experience with Gov. Required 5 Year (s) Online UPS Modular Type ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Online UPS Modular type should supoort for Data Centres | - | - | - |
| Network operating centres | - | - | - |
| Security operation centres | - | - | - |
| State and District centres | - | - | - |
| Command and Control centre etc. | - | - | - |
| across the Country to provide impetus to the e- Governnance services e.g.Public food distribution | - | - | - |
| e Way bill | - | - | - |
| Counseling | - | - | - |
| e-Office | - | - | - |
| IVFRT etc. | - | - | - |
| services under Digital India Programme Yes * Modular type UPS equipped with Yes * 1/9 microprocessor/Digital signal processor and power modules | - | - | - |
| Power expansion facility | - | - | - |
| LCD/Digital display upto maximum expandable capcity | - | - | - |
| Cable entry | - | - | - |
| RS 232 port and SNMP port with each power module and with suitabale rack (compatible maximum expandable) with complete lockable door having visibility for maximum expandable capacity Output power capacity including re dudancy/Expandable (Rack facility) upto/Minimum backuptime (including redudancy) Minimum VAH (VAH shall be calculate Battery voltage x Battery Ah x No. of batteries = Total VAH) 150 KVA/250KVA/30 Minutes/123000 VAH * VAH tolerance -1% of the defined capacity * Hot swappable power module Yes * Battery module using two or more strings in parallel for redudanct supply and battery module shall be fuse protected Yes * Inverter Technology PWM with IGBT | - | - | - |
| double conversion * Output wave form Pure sine wave * Country of origin for Inverter India * Noise level </= 65 dB </= 55 dB | - | - | - |
| </= 65 dB | - | - | - |
| </= 70 dB Type of cool (Minumum 2 Fans for each power module) Air cooled * 2/9 Parallel (Power Modules) load sharing redundant operation with all accessories Yes * Installation and commissioning Yes * UPS shall be supply with insallation and operation manual Yes * INPUT Input AC Three Phase * In put Voltage Range 320 V to AC to 470 V AC 3 Phase 320 V to AC to 470 V AC 3 Phase | - | - | - |
| 340 V to AC to 470 V AC 3 Phase Input frequency range 50 +/-6% Hz * Input power factor at full output load leading to unity with active power factor correction (APFC) (from 25% load to 100% load) >/=0.99 * Distortion (current) </= 3% </= 3% | - | - | - |
| </= 5% UPS shall have DG set compatibility Yes * OUTPUT Output AC Three Phase * Out put voltage 380/400/415 | - | - | - |
| 3 phase | - | - | - |
| 4 wire * Voltage regulation (Steady state) at No load to full load | - | - | - |
| 0.6 lag to Unity PF | - | - | - |
| During entire back up time | - | - | - |
| Complete input voltage range +/-1% * Output powr factor >/= 0.90 * Frequency 50 Hz +/-0.5 % Hz * CONSTRUCTION Minimum thickness (in mm) of Rack Enclosure for Modular UPS duly powder coated 1.2 2.0 | - | - | - |
| 1.2 UPS shall be free from workmanship defects | - | - | - |
| sharp edges | - | - | - |
| nicks | - | - | - |
| scratches | - | - | - |
| burst | - | - | - |
| etc. All fasteners shall be fixed properly. The equipment shall be complete with all parts and all parts shall be Yes * 3/9 functional UPS enclosure's degree of protection as per IS:13947 (Part 1)/1993 latest IP20 IP21 | - | - | - |
| IP20 Standard quality Out put terminals shall be provided for output connection Yes * UPS shall have static and manual by pass facility Yes * UPS shall be supplied with required rated power cable (Copper) 5 Meters * Total Harmonic Distrotion (THD) for 100% linear load < 3% < 3% | - | - | - |
| < 2% Total Harmonic Distrotion (THD) for 100% non-linear load < 4% < 5% | - | - | - |
| < 4% Operating temeprature 0 deg C to +40 deg C * Humidity Upto 95% non- condensing * Operational: 1000 meters above sea level at 40 deg. C maximum Yes * Crest factor on full non- linear load Not less than 3:1 * Over all efficiency on rated full load of 0.8 PF (min.) AC output >/=90% * Inverter efficiency on rated full load of 0.8 PF (min.) AC output >/=95% * UPS shall withstand Over load capacity - 125% (Output with mains AC-AC) for 5 Minutes (Minimum) * UPS shall withstand Over load capacity - 150% (Output with mains AC-AC) for 60 seconds (Minimum) * UPS shall withstand Over load capacity - 125% (Output in battery run DC-AC) for 2 Minutes (Minimum) * UPS shall withstand Over load capacity - for 30 seconds (Minimum) * 4/9 150% (Output in battery run DC-AC) Load power factor 0.8 lagging to unity Yes * Transient response time (for 100% load change | - | - | - |
| output must remain within +/-1% and recovery) <20 milli seconds * PROTECTION Short circuit protection Yes * Over load protection Yes * Over temperature protection Yes * In put low/high voltage control Yes * DC low/high voltage trip Yes * Back feed protection for both | - | - | - |
| mains and bypass input Yes * BATTERY Battery shall conforming to JISC:8702(Pt.I | - | - | - |
| II&III) latest or equivalent BIS standard Yes * Battery type SMF VRLA * Country of origin for Battery India * Battery recharge time (after complete discharge to 90% charge) and charge rating: Battery recharge time to 90% charge after 100% DoD 8 to 10 hours * Battery charger (One in each power module) should be capable to charge battery on C10 rating Yes * Battery cutoff voltage during back up Not less than 10.5 V * Batteries shall supply with With metal rack * Modular UPS shall supply with DC Cable from UPS to battery and batteries to UPS | - | - | - |
| Battery interlink cables | - | - | - |
| Yes * 5/9 battery breaker Meters | - | - | - |
| Indicators and Display All the meters and display LCD/Digital type shall support for maximum expanadable capacity Yes * Input: Voltage line to line and line to neutral | - | - | - |
| currents | - | - | - |
| frequency | - | - | - |
| power factor display Yes * Bypass: Phase voltage | - | - | - |
| line to line voltge | - | - | - |
| frequency display Yes * UPS Output: Phase voltage | - | - | - |
| phase currents | - | - | - |
| line-line voltage | - | - | - |
| power factors | - | - | - |
| frequency display Yes * Local load: Load of each phase (% age of total load) | - | - | - |
| Active power (KW) | - | - | - |
| Apparent power (KVA) | - | - | - |
| and Ractive power (KVAR) of each phase | - | - | - |
| load crest factor display Yes * Battery: Battery bus voltage | - | - | - |
| battery charge and discharge current | - | - | - |
| forecasted battery back up time | - | - | - |
| battery capacity (Ah) Yes * Parrallel load (for parallel operation system): Apparent power (KVA) of each phase | - | - | - |
| Active power (KW) of each phase | - | - | - |
| reactive power (KVAR) of each phase Yes * UPS shall have an indication for Mains on | - | - | - |
| Load on battery | - | - | - |
| Inverter | - | - | - |
| Battery level | - | - | - |
| Load level | - | - | - |
| Inverter over load Yes * UPS shall have audible alaram for over temperature | - | - | - |
| mains failure | - | - | - |
| battery low | - | - | - |
| inverter overload Yes * Communication Yes * 6/9 interface: SNMP/MODB US/HTTP/JAVA/UPSMON SMTP etc. | - | - | - |
| and 2 serial port USB/RS232 | - | - | - |
| RS485 | - | - | - |
| 1 logic level port | - | - | - |
| 4 Dry contacts ports Log History storage facility with display (minium 200 events) Yes * WARRANTY AND SERVICES Warranty for Modular UPS (on site comprehensive warranty) (in years) 5 3 | - | - | - |
| 5 Warranty for battery (replacement warranty) (in years) 5 2 | - | - | - |
| 3 | - | - | - |
| 5 After sales and complaint service within 24 hours within 24 hours | - | - | - |
| within 48 hours | - | - | - |
| Within 7 days PAN India service support on 24 x 7 basis Yes Yes | - | - | - |
| No AMC support available after 3 year warranty Yes Yes | - | - | - |
| No Quarterly preventive maintenance Yes Yes | - | - | - |
| No Manufacturer shall provide and support for installation | - | - | - |
| commissioning | - | - | - |
| spares | - | - | - |
| technical support all over India Yes Yes | - | - | - |
| No Availability of spares in close proximity (Spares should be easily available close to the site) Yes Yes | - | - | - |
| No CERTIFICATIONS ISO: 9001 Certification Yes * ISO: 14001 Certification Yes * Environmental compliance certificate RoHS Yes * CE Certification and marking Yes Yes | - | - | - |
| No UPS shall meet and comply with the General and safety Yes * 7/9 requirements as per IEC:62040-1 UPS shall meet and comply with the Electromagnetic compatibility (EMC) requirements as per IEC:62040-2 Yes * Damp Heat Test : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C | - | - | - |
| two cycles of (12+12) hours each 2007) Yes Yes | - | - | - |
| No Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes Yes | - | - | - |
| No Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes Yes | - | - | - |
| No Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * All the test reports and certificates shall furnish by the supplier to the buyer/consignee on demand Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ravindra Kumar Pandey 110003 | - | - | - |
| NATIONAL INVESTIGATION AGENCY | - | - | - |
| OPPOSITE CGO COMPLEX | - | - | - |
| LODHI ROAD | - | - | - |
| NEW DELHI 1 45 8/9 | - | - | - |
₹1.9 L
22 Oct 2018
3 Oct 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_686043.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .