GE AF THANE
Office of Military Engineer Services ,Garrison Engineer (AF) Thane, Kolshet Road, Sandoz Baugh Post, Thane 400607
SPECIAL REPAIR TO WIRING AT CERTAIN OTM BLDG AND ROOF TREATMENT AT CERTAIN MD ACCN / OTM AT AF STN KANHERI HILLS UNDER GE AF THANE
2026_MES_793151_1
GE (AF) T-66 OF 2026-27 (8683)
Open Tender
Civil Works
Item Rate
180 days
THANE
AS PER NOTICE OF TENDER
8 documents required · 8 mandatory
₹500
GE AF THANE
₹88,000
Yes
9 Oct 2026
9 Oct 2026
4 Nov 2026
9 Oct 2026
28 Oct 2026
23 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Removing existing water proofing treatment where so ever exist (except concretepadding) and removing debris/rubbish off the site complete all as specified and directed by Engr-in-Charge. | 2,300 | SQM | - | - |
| 2 | Demolition of cement concrete of any description and in any position provided as in roof padding, roof curb etc complete all as specified and directed by Engr-in-Charge. Note: - (a) Demolition should be done carefully to roof slab. (b) Any damage occurred in the roof surfaces during demolition shall be made good by the contractor without extra cost to the department. (c) Disposal of debris/retrieved materials shall be thrown out of site at place | 57.5 | CUM | - | - |
| 3 | M&L for providing PCC type B-1, (1:2:4) using 20mm graded stone aggregate as in roof padding laid in slope as per requirement mixed with integral water proofing liquid admixture as per manufacturer's instructions complete all as specified and directed by Engr-in-Charge.
Note : (i) Minimum thickness of PCC shall be 50mm. (ii) Integral water proofing liquid admixture shall be measured and paid separately under appropriate item here in after | 57.5 | CUM | - | - |
| 4 | M&L for 10 mm thick plaster in roof surface in CM 1:3 mixed with integral water proofing liquid admixture as per manufacturer's instructions complete all as specified and directed by Engr-in-Charge. | 1,150 | SQM | - | - |
| 5 | Supply only Liquid water proofing compound complete all as specified and directed by Engr-in-Charge. | 120 | LTR | - | - |
| 6 | Material and labour for water proofing treatment with APP based standard membrane over in roof with the following courses of treatment for:-
(a) Apply bituminous primer (IS 3384) @ 0.40 Ltr per sqm of the surface area including cleaning the surfaces complete all as specified and directed by Engr-in-Charge.
(b) Applying APP based polymeric membrane, minimum weighing 3Kg/Sqm and minimum 3mm thick, over a coat hot blown bitumen grade (30/40) applied @ 1.20 kg/Sqm with side overlap of membrane shall be minimum 75mm and end overlap shall be 100mm and torch bonded at joints including surface preparation before and after application of treatment as per manufactures instruction complete all as specified and directed by Engr-in-Charge.
(c) The entire surface of finished APP membrane shall finally be painted with two coat of Solar reflective bituminous aluminium paint @ 0.1 ltr per Square Meter and other as prescribed by manufacturer ,complete all as specified and as directed by Engr-in-charge | 2,300 | SQM | - | - |
| 7 | Fixing only, after cleaning old steel water tubing, 20mm bore and connections in new or old position using new fittings complete all as specified and directed by Engr-in-Charge. | 78 | RM | - | - |
| 8 | Taking up or down existing steel water tubing, 25mm bore alongwith connections fixed/laid in any situation complete all as specified and directed by Engr-in-Charge. | 60 | RM | - | - |
| 9 | Fixing only, after cleaning old steel water tubing, 25mm bore and connections in new or old position using new fittings complete all as specified and directed by Engr-in-Charge. | 40 | RM | - | - |
| 10 | S&F Galvanised iron steel water tubing, 25mm bore, medium grade with all fittings and fixed to walls and ceilings or laid in floors complete all as specified and directed by Engr-in-Charge. | 20 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
TD8683.pdf
Tender Documents • 2.02 MB
BOQ_889440.xls
BOQ • 0.46 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .