Loading…
Loading…
Tender Value
₹6.5 Cr
EMD Value
₹4.8 L
Closing Date
19 Dec 2025, 3:00 pmClosed
Salem Division-SAMT-Proposed Goods Yard remodelling work for direct Reception and Dispatch facility.
SA-SG-120-I-OT-14-2025~SR
SA-SG-120-I-OT-14-2025
Open
Works - General
12 Months
Salem, Tamil Nadu
₹0
₹4.8 L
19 Dec 2025
27 Nov 2025
5 Dec 2025
A-Items which are covered under SOR 2022.
B-Items which are not covered under SOR 2022.
Item Breakup - A-Items which are covered under SOR 2022.
1.00 948672.10 per enclosed drawing No PROJ/SG/MS/70/2019 - work space (as approved by engineer in charge) with control desk for 2 monitors, 2 operators & one module to be provided for storage - should include space for housing Two nos of Embedded PCs, 2 nos FDMS and their Power supply arrangement for with proper ventilation with two chairs (as per Drawing enclosed or as per site requirement)
Submission drawings/ Plans, Ru l e Diagrams, Station Working Rules, CRS Documents, TSAA documents" SALEM DIVISION-S AND T/SOUTHERN RLY
1.00 signalling installations j o i n t l y w i t h the R a i l w a y representative a t s i t e a t the stations/ L C gates covered under various schedules of the Contract and ensuring that all t h e signalling gears a r e installed and adjusted as per the existing rules. The work also involves s u p p l y o f required n u m b e r of bound registers w i t h good quality papers with all updated details of cable meggering, relays, batteries, block joints, route cancellation, relay roo m key e n t r i e s , block instrument k e y , earth resistance e t c . , and handing over to Railways. (Supply of 'As mades' is not covered in this schedule)."Testing and commissioning of stations (more than 5 roads)
200.00 of circuit diagrams, contact analysis charts, termination particulars of apparatus cases and cable termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the 'As mades' check print shall be submitted before Testing the circuits. The final negatives shall be made in tracing sheet (80 to 90 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back to back in one plastic cover) and handed over to Railways. Also the contractor has to supply one set of As mades in 'Reproduction Film'. The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as-made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incoporate the details of all the new wirings and alterations in the CD/ RP film and submit them to Railways. Onapproval 8 copies shall be made for As-made circuit diagrams also as mentioned above"
1.00 491478.25 Digital and 32 Analog as per RDSO spec .no IRS-S-99/2006 o r l a t e s t including Power Supply and Back-up arrangements(This work does not includes wiring of inputs from Relay to Intermediate t a g b l o c k & from intermediate tag block t o Datalogger equipment)
1.00 analysis of fault and generating reports for Datalogger installed a t stations. A s per Technical Specifications."
1.00 Electronic Interlocking system equipment SALEM DIVISION-S AND T/SOUTHERN RLY
1.00 converter suitable to insert in the Datalogger Eurorack for inter-linking Datalogger/MFEP
1.00 Dual Card modem as per RDSO specification IRS:S-99/2006 or latest. As per technical Specification
1.00 D i g i t a l a n d 3 2 A n a l o g . T h i s includes transportation o f materials t o Site location a n d provision o f Ladder a n d cable trough arrangements including connection t o the BRC earth. Also includes carrying out of pre- commission checklist a n d Networking of datalogger. (This schedule doesn't cover w i r i n g and preparation of Simulation chart)"
300.00 Wago block to Datalogger. Necessary Wagos required is included as per schedule
50.00 Datalogger. Necessary Wagos required is included as per schedule
1.00 analysis of fault and generating reports for Datalogger installed at stations)
1.00 with one Dual card Modem.)
20.00 Class D Surge Protection Device f o r 24V DC/48V DC (spark gap type), with Potential Free contacts and installed as per the instructions of t h e Engineer i n charge at site ( OBO, DEHN, PHOENIX, LPI, ZOTUP, H A K E L or better make).All other m iscellane o us m a t e r i a l s required for installation s h a l l b e s u p p l i e d b y the contractor.
20.00 Class D SPD of Operating Voltage of 110V AC/DC with Potential Free contacts and installed as per t h e instructions o f the Engineer in charge a t s i t e (OBO, DEHN, PHOENIX, LPI, ZOTUP, HAKEL or better make). All other miscellaneous materials required for installation shall be supplied by the contractor.
5.00 RDSO Specification RDSO/SPN/197/2008 or l a t e s t ( a s p e r Te c h n i c a l Specification enclosed)
40.00 no SG/CN/02/13 SALEM DIVISION-S AND T/SOUTHERN RLY
40.00 drawing No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor].
50.00 of size 1050x25x3mm as given in enclosed Box drawing t o connect a l l cable armours to earth point with suitable nuts/bolts as given below. A) G I nuts/bolts o f size 8x25mm w i t h Two flat a n d o n e spring washer o f 23set. B ) GI nuts/bolts o f size 12x40mm w i t h t w o flat and one spring washer of 02set as per site incharge"
20.00 of size 550x25x3mm a s given i n enclosed Box drawing t o connect a l l cable armours to earth point with suitable nuts/bolts as given below. A) G I nuts/bolts o f size 8x25mm w i t h Two flat a n d o n e spring washer o f 23set. B ) GI nuts/bolts o f size 12x40mm w i t h t w o flat and one spring washer of 02set as per site incharge"
1.00 150841.73 D e t e c t o r a s p e r R D S O Specifications RDSO/SPN/256/2002 or latest
1.00 AC/110V AC, 3000VA as per IRS S-72
1.00 3KVA as per IRS Specifications No S-74-89
125.00 and carrier with 4/6/10/16/20A/32 A fuse as p e r t h e loa d condition a t location boxes, c a b l e h u t s e t c . a s p e r approved circuit diagram. This work also includes painting of particulars of HRC fuse block installed in p o w e r p a n e l i n s t r u c t e d b y Railway representative a t s i t e . ( H RC f u s e block, Fu s e s , w i r e s , C u . l u g s a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor.)
1.00 S t a n d a t stations/Huts/Power r o o m at station. As per drawing enclosed SALEM DIVISION-S AND T/SOUTHERN RLY
1.00 phynolic sheet 1200mm x 1200mm x 10mm and erecting i t u s i n g M S angles
meters, stabilizer and ammeter b y pass switches, H RC fuse blocks, P B T terminals
equipments t o the power p a n e l a s per approved power diagram, in the power room.)
60.00 2V, 300Ah - 1 c e l l a s p e r RDSO Specifications IRS S: 93/96 with Amnd 1 or latest
1.00 1307398.11 per RDSO Specifications RDSO/SPN/165 or l a t e s t ( T h i s schedule d o e s n o t include Batteries) As per drawing enclosed
45.00 o f t h e following capacities with necessary inspection a s p e r specification/ drawing/ description enclosed in this document.b)Supply of Secondary cells - 2V- 80AH capacity
Numbers SALEM DIVISION-S AND T/SOUTHERN RLY
1.00 219668.82 suitable power equipment s t a n d i n the power room at stations (with more than 5 roads) usingM.S. Angles 65mm x 65mm x 8mm and MS flats 50mmx6mm covered with 100mmx50mm hardwood reapers, installation of power equipments and wiring the same using wire P V C 7/1.4mm and 3/0.75mm copper a s p e r approved wiring diagram, fabrication and installation of Power p a n e l B o x t y p e u s i n g powder coated 16G M S sheet w ith inbuilt locking facility with a power distribution board fitted inside made o f Phynolic synthetic industrial fibre base fine weave cotton fibre sheet of size 1200mm X 1200mm X10mm. Terminations using circuit breakers, HRC fuse blocks and PBT terminals s h a l l be provided o n the phynolic sheet. DIGITAL Voltmeters, ammeters a n d b y pass switches shall be fitted on the front side of t h e M S power panel. T h i s w o r k includes installation of power distribution diagram board using phynolic sheet 6mm thick of size 1800mm x 1200mm w ith Aluminium grooved channel frame i n t h e relay room. The particulars shall be digitally using good quality laminated g u m sheet. (Supply of power equipments i s n o t covered i n this schedule).[M S a n g l e s 65mmx65x8mm, Phynolic synthetic industrial fibre base fine w e a v e c o t t o n fi b r e s h e e t o f size 1200x1200x10mm, Hard Woo d planks for reapers 100x50mm, Power coated 16G MS s h e e t , teakwood b a s e p l a n k s 2 5 m m x 150mm and 50mm x 50mm for fixing cables, 50mm, bolts & n u t s required for manufacturing power panel & power rack, circuit breakers, HRC Fuses with base and carrier, ammeters, voltmeter- 3 Nos., by- pass switches for stabilisers-63A capacity - 3 Nos., power distribution diagram board using phynolic sheet - 6 m m thick o f size 1200X1800mm w i t h Aluminium grooved channel frame, paints, wire P V C 7/1.4mm a n d 3 / 0 . 7 5 m m c o p p e r , a n d a l l other miscellaneous materials required shall be supplied by the Contractor
194.95 2.5sq.mm 2 IN 2 OUT type disconnect type of Wago/Phoenix make or similar along with accessoriesa sp e r RDSO Spec.No.RDSO/SPN/189/2004/ rev 2 or latest.
500.00 indication upto 2.5sq.mm screw type 1 IN 1 O U T ( Suitable 400mA, 630mA, 1 A , 1.6A, 2A, 4A, 6.3A, & 10A) (Without Fuse) as per RDSO Spec.No.RDSO/SPN/189/2004/ r e v 2 or latest."
25.00 color SALEM DIVISION-S AND T/SOUTHERN RLY
1.00 stripper for modular terminal. These tools shall b e o f Wago/Phoenix make o r similar and model suitable for the modular terminal supplied
1.00 to'KILBURN' make capacity 3.5 to 4.5 Lits. per hour, with two detachable heating elements of 1500W each to work on 230VAC, single phase, fitted with automatic cut-outs and removable connectors, with Stainless Steel boiling chambers, condenser pipe, toughened glass lid; Distilled water plant, tank 200 Litres capacity similar to sintex make, GI pipe 25mm dia, power plug with socket, regulating valves, jelly, cement, sand and other materials shall be supplied by the Contractor"
1.00 provision o f water supply connection from water t a p t o w a t e r t a n k , w a t e r t a n k to distilled water plant using G.I Pipes 25mm dia and with regulating valves, provision of separate power supply socket a n d wiring. This work includes fixing of 2 Nos. of rails on the wall a n d grouting a s instructed by Railway representative at site. (Cut rails will be supplied by Railways)."
1.00 Detector. T h i s includes transportation of materials t o Site location a n d provision of c a b l e t r o u g h a r r a n g e m e n t s including connection to the BRC earth.Also includes carrying out of pre-commission checklist.
1.00 Capacity 230V A C , 3 t o 5KVA. Necessary w ire coils required i s covered under the scope including connection to earth bus bar.
1.00 Capacity 1/2/3KVA. Necessary w i r e coils r e q u i r e d i s c o v e r e d u n d e r t h e scope including connection to earth bus bar.
1.00 includes arrangement o f OEM engineer for checking the Installation and carrying out adjustments of IPS modules and submission of Pre- commissioning checklist
1.00 RDSO Specification No. RDSO /SPN /165 or latest.This w ork includes transporting the IPS from the Stores by loading without any damages and installation of the same at site. This a l s o i n c l u d e s w i r i n g o f all modules, proper earthing of equipments and all other works connected f o r testing and commissioning of the same. Necessary p o w d e r e d c o a t e d A l u m i n i u m ladder arrangements i n c l u d i n g cable trench, pipes, bolts, a n d o t h e r accessories is included in this schedule.[Earthing i s not covered under this schedule] SALEM DIVISION-S AND T/SOUTHERN RLY
28.97 along w i t h accessories w i t h provision of fixing holes o n hylam sheet/side angles of Location Box and fixing by Galvanized nuts and bolts. This includes fixing of DIN channel for cable termination on Modular terminal
28000.00 i n s u l a t e d Armoured, unscreened underground Railway Signalling copper cable as per IRS: S-63/2014 REV.4
15000.00 Armoured, unscreened underground Railway Signalling copper cable as per IRS: S-63/2014 REV.4
1000.00 Armoured, unscreened, underground Railway Signalling Copper cable as per spec IRS.S.63/2014(Rev.4.0) or latest"
1500.00 insulated Armoured, inscreened underground Railway Signalling copper cable as per IRS: S-63/2014 REV.4
2500.00 0.9MM Dia a s p e r spec IRS:TC 30-05 with amd 5 or latest
2000.00 p e r R D S O Specification RDSO/SPN/TC/ 110/2020 Rev. 0 or latest
500.00 Sheathed armoured Jelly Filled Telephone C a b l e w i t h Poly-AL Moisture Barrier, 20 Pairs, 0.63 MM Conductor Diameter a s per RDSO Specification N o . IRS:TC-41/97 with amendment 1 or latest
300.00 PC/LC- PC t o FC-PC/SC-PC/LC-PC s o a s to suit for switches and FMS supplied)"
f S w i t c h B o a r d cable, Metre Fi n o l e x / D e l t r o n m a k e o r better 0.5mm/10Pairs, conforming to IRS/TC/24- 91 cable
1000.00 UL or CE3P certified panduit or Systimax or R & M o r A M P o r M o l e x o r K r o n e O r D- LinkMakes
2.00 housed in MS box and termination of Cables
1.00 ohms)for terminating 1 6 E 1 s o f wrapping type & Mountable on 19" rack similar to TVSmake or better.
1.00 b u t t o n switches a n d h a v i n g conference facility. Model N o AM-10 similar t o Epsilon, Telelinks or better"
10.00 Thermo shrink jointing kit (RDSO specs No TC/77/2012 ( Re v. 3 ) w i t h amendment N o . 1 & 2 o r l a t e s t . & j o i n t i n g k i t t o be inspected b y RDSO) f o r 4 / 6 q u a d cable normal joint. The work includes excavation o f j o i n t p i t o f s i z e 1mX1.5mX1.5m and closing the same after completion o f cable j o i n t a s p e r t h e instruction o f Railway representative at site. SALEM DIVISION-S AND T/SOUTHERN RLY
4.00 enclosure for armoured optical fibre cable c o n f o r m i n gt o RDSO spec.RDSO/SPN/TC/68/2014 rev2.0 or latest
100.00 RCC cable markers a s p e r drawing No.CSTE/CN/OFC/1. T h e lettering o n the cable marker shall be "SIG" / "TELE" / "OFC" as p e r t h e instructions o f Railway representative a t s i t e . ) as per drawing enclosed
20.00 covering of G I Pipes/cables. Providing & L a y i n g in position c e m e n t concrete of specified proportion i n c l u d i n g c o s t of cement, centering a n d shuttering with 1:3:6 composition 1 Cement: 3 S a n d : 6 grade stone aggregate 25mm nominal size) (Cement, M-Sand, stone jelly of 25mm and a l l other m isc materials required f o r the work should be supplied by Contractor).
3000.00 board (10 pair/ 20 pair/50 pair) Cables in 1" PVC conduit/case caping a n d clamping on t h e wall/Roof tops/ Shelters w i t h suitable clamping a n d hose t o b e provided where e v e r b e n d s / c u r v e s ( P V C conduit/ Case capping and other accessories to be supplied by the contractor)
1750.00 soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this schedule)
200.00 on the Passenger Platform, trenching to a depth of 0 . 6 m t o accommodate the additional cables, replacing the slabs removed after the cables are laid and replastering with cement mortar, refilling the trench by ramming and consolidating it a s p e r t h e in s tru c tio n s of Railway Representatives at site. (Laying of cables is not included in this schedule).
240.00 for track crossing of cables, refilling of trench by ramming and consolidating i t as p e r the instructions of Railway representative at site after l a y i n g of D W C / RC C p i p e s . During excavation of trench, i t h a s t o b e ensured that the excavated soil does not mix with the ballast available. T h e depth o f 1 m trench shall b e fro m t h e bottom o f sleepers for track crossings. Laying o f cables and DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule).
60.00 for road crossing of cables, laying of DWC/ RCC pipes with collar/ coupling, refilling of trench by ramming and consolidating it and resurfacing it to the original position. Laying of cables is not included in this schedule. (Supply o f DWC/RCC pipes with couplers/collars is not included in this schedule). SALEM DIVISION-S AND T/SOUTHERN RLY
180.00 cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site. (Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor.
120.00 cable laying in hard rocky area with off sets at b o t h e n d s d u l y supported by concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall b e c l o s e d w i t h brick masonry abutments work so that no cable is exposed, The work shall be carried out as p e r the instructions of Railway representative at site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).[Stone jelly of size 20/25mm, bricks, sand, cement, and all other miscellaneous materials required for t h e w o r k s h a l l be supplied by the Contractor].
f signaling/power/ Metre telecommunication cables as per cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply of cables is not included in this schedule).
1750.00 width throughout, with earth after laying of cables, a n d consolidating t h e trench by ramming and levelling."
f o u n d a t i o no f size 300mmX300mmX300mm and Placing of RCC cable markers on top of the foundation and refilling the pit and consolidating i t by ramming. T h e cable markers s h a l l be provided a t a n interval of 20 Mtrs. within station limits a n d 5 0 Mtrs. outside station l i m i t s t h r o u g h o u t t h e cable route, diversions a n d a l s o a t every track/road crossing." SALEM DIVISION-S AND T/SOUTHERN RLY
2.00 1.5mx1.5m a n d d e p t h a s instructed by Railway representative at site, for coiling the cables i n r e a r o f relay rooms/ AFTC huts, apparatus c a s e s e t c . T h e work includes coiling t h e underground cables a n d placing closely o n e layer o f country bricks o f size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling.[Country bricks of size
shall be supplied by the Contractor].
120.00 Horizontal Drilling at approximately depth of 1.5 to 2 m below t h e formation level of the earth including insertion of HDPE pipe/DWC pipe along with couplers, drawl of cable (or) direct drawl o f cables etc. (Note: The pilot used for HDD should be of sufficient size to suit insertion o f HDPE /DWC pipe o f size 120mm (outer dia.) or direct drawl of three cables (Signalling/Power/Quad/OFC) or three nos.of 40mm d i a HDPE pipe o r a n y other combination a s d i r e c t e d b y t h e site engineer) ( Supply o f H D P E p i p e i s not covered in this schedule)"
2000.00 cable/Signalling cable inside permanently solid lubricated HDPE Pipe already laid. This work includes necessary duct integrity test for solid lubricated HDPE pipe. ( This includes Transportation o f materials from nominated stores to site)
2.00 as per R D S O Specifications No.RDSO/SPN/199/2010 Rev1.1 or latest
9.00 as per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest
9.00 per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest
20.00 L E Da s p e r R D S O Specifications SPECIFICATION N O . RDSO/SPN/153/2023 Revision 5.0 or latest
13.00 o n L E D a s p e r R D S O Specifications SPECIFICATION N O . RDSO/SPN/153/2023 Revision 5.0 or latest
40.00 L E Da s p e r R D S O Specification SPECIFICATION N O . RDSO/SPN/153/2023 Revision 5.0 or latest
1.00 Double Digit) from 1 t o 9 with white LED (With Housing) as per technical specification
2.00 d i a , 4 . 6 m / 3 . 6 m t a l l w i t h necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply o f colour light Signal pole 4.6m tall and 140 mm dia(Galvanised) SALEM DIVISION-S AND T/SOUTHERN RLY
7.00 d i a , 4 . 6 m / 3 . 6 m t a l l w i t h necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply o f colour light Signal pole 3.6m tall and 140 mm dia (Galvanised)
9.00 pole 140mm dia with necessary inspection a s p e r specification/ drawing/ description enclosed in this document.
2.00 s u i t C L S p o l e 4 . 6 m / 3 . 6 m t a l l , with necessary inspection a s p e r specification/ d r a w i n g / description e n c l o s e d i n this document. a)Supply of ladder with platform (4.6m) for CLS(Galvanised)
7.00 s u i t C L S p o l e 4 . 6 m / 3 . 6 m t a l l , with necessary inspection a s p e r specification/ d r a w i n g / description e n c l o s e d i n this document. b)Supply of ladder with platform (3.6m) for CLS(Galvanised)
7.00 with hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document.
8.00 complete w i t h surface base, signal pole, hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document.
2.00 type- complete for 4/ 3/ 2 aspect with mounting socket, with necessary inspection a s per specification/ drawing/ description enclosed in this document. b)Supply of colour light Signal unit (3 aspect)
7.00 type- complete for 4/ 3/ 2 aspect with mounting socket, with necessary inspection a s per specification/ drawing/ description enclosed in this document. c)Supply of colour light Signal unit (2 aspect)
2.00 unit arm - 1/ 2/ 3/ 4/ 5/ 6 way with mounting sockets, with necessary inspection as per specification/ drawing/ description enclosed in this document. d)Supply of Junction type route indicator - 4 way
13.00 light - complete with necessary inspection as per specification/ drawing/ description enclosed in this document. a)Supply of Calling On Signal
2.00 made of cast iron with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply of Off set bracket - large
2.00 made of cast iron with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply of Off set bracket - small SALEM DIVISION-S AND T/SOUTHERN RLY
2.00 w i t h n e c e s s a r y i n s p e c t i o n a s per specification/ drawing/ description enclosed in this document.
2.00 facility of paging a n d talk-back including voice communication e q u i p m e n t with suitable switching arrangement a t the S i g n a l post and a t S M ' s r o o m a s per specification enclosed i n t h i s document. This includes drawl of tail cable through GI p i p e 25mm dia and 2 mtrs long duly clamped to Signal post w i t h b e n d as required at site, termination of tail cable at one end in the apparatus case and other end in the console. In the SM's room, console shall be fixed on a table top. The w i r i n g s h a l l b e d o n e using wire PVC 16/0.2mm copper. [Talk-back equipment complete including housing box, wire PVC 16/0.20mm a n d all other miscellaneous materials required for the w o r k shall be supplied by the Contractor].
30.00 Magnetically Latched Neutral Line 24V DC, 11F/4B contacts Relay complete with plug board (base plate), connectors and retaining clips and conforming to BRS 935A and RDSO Spn. N o I R S S 3 4 a n d S - 2 3 or latest. The interlocking code f o r this unit shall be "ABDEG"
10.00 Key Lock Checking Relay (KLCR) with one number K-50 neutral Relay to work on 24V DC non AC immunized a s per specification No.RDSO/SPN/219/2016 Ver 1.0 with Amdt- 1 o r latest (with one extra ward plate and with case) contact configuration-4F/4B and as per IRS:S-23, IRS:S@58"44@ IRS:46 or latest.
35.00 a)LED aspects with plug boards, connectors and retaining clips with necessary inspection as per specification/
5.00 frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug i n type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d Point control circuits, fixing o f p l u g b o a r d s , relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring a n d termination as per approved circuit diagram and painting the particulars.[Wire P V C c o p p e r , 3 / 0 . 7 5 m m and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6 m m brass bolts a n d nuts, p a i n t s , s o l d e r i n g materials, resistors, condensers a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. a)Wiring of Signal/ point/ LC control circuit (up to 4 relays/Plug in type) SALEM DIVISION-S AND T/SOUTHERN RLY
10.00 frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug i n type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d Point control circuits, fixing o f p l u g b o a r d s , relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring a n d termination as per approved circuit diagram and painting the particulars.[Wire P V C c o p p e r , 3 / 0 . 7 5 m m and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6 m m brass bolts a n d nuts, p a i n t s , s o l d e r i n g materials, resistors, condensers a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. b)Wiring of Signal/ Point/ L C control circuit (up to 8 relays/plug in type)
10.00 frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug i n type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d Point control circuits, fixing o f p l u g b o a r d s , relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring a n d termination as per approved circuit diagram and painting the particulars.[Wire P V C c o p p e r , 3 / 0 . 7 5 m m and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6 m m brass bolts a n d nuts, p a i n t s , s o l d e r i n g materials, resistors, condensers a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. c)Wiring of Signal/ Point/ L C control circuit (up to 12 relays/plug in type) SALEM DIVISION-S AND T/SOUTHERN RLY
8.00 frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug i n type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d Point control circuits, fixing o f p l u g b o a r d s , relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring a n d termination as per approved circuit diagram and painting the particulars.[Wire P V C c o p p e r , 3 / 0 . 7 5 m m and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6 m m brass bolts a n d nuts, p a i n t s , s o l d e r i n g materials, resistors, condensers a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. d)Wiring of Signal/ Point/ L C control circuit (up to 20 relays/Plug in type)
2.00 Nos of KLCRs
and e r e c t i o n o f cable Numbers termination r a c k 500/210/140 Terminals capacity o n teakwood base frame o f size 50mmx150mm of suitable length and width with rectangular slot in the centre for taking in t h e cables a n d painting a s per standard practice.(Supply o f cable termination racks a r e not included in this schedule).[Foundation bolts a n d nuts with washers, cement, sand, stone jelly, teak w o o d base frame 50mmx150mm of suitable length and breadth, paint, varnish a n d a l l other miscellaneous materials required for the work shall be supplied by the contractor]. b)Concreting and erection of cable termination rack -500 terminal capacity SALEM DIVISION-S AND T/SOUTHERN RLY
2000.00 block, rubber grommets, clamping of cables using teakwood cable clamps and base planks, t e r m i n a t i o n o f cables, provision of ND t y p e f u s e s o f required capacities, provision o f copper bus bar for supply terminals, w i r i n g , p r o v i s i o n of termination particulars d i a g r a m board u s i n g p l y w o o d of thickness 1 2 m m - teakwood finish of size 1800mm x 1200mm with Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rack shall be covered with phynolic sheet o f thickness 3 m m wherever required. T h e termination and cable core particulars shall b e painted o n t h e PVC/ nylon sleeves. T h e work also includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply o f PBT terminal blocks 25mm & 60mm centers and P B T Fu s e blocks i s not covered in the schedule) [Wire P V C 3/0.75mm copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm for base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel f r a m e , phynolic sheet 3 m m thick, paint a n d a l l other miscellaneous materials shall be supplied by the Contractor]. a)Fixing of PBT terminal blocks (25mm/60mm centre) and termination (Per Unit = Per Terminal Block) SALEM DIVISION-S AND T/SOUTHERN RLY
100.00 block, rubber grommets, clamping of cables using teakwood cable clamps and base planks, t e r m i n a t i o n o f cables, provision of ND t y p e f u s e s o f required capacities, provision o f copper bus bar for supply terminals, w i r i n g , p r o v i s i o n of termination particulars d i a g r a m board u s i n g p l y w o o d of thickness 1 2 m m - teakwood finish of size 1800mm x 1200mm with Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rack shall be covered with phynolic sheet o f thickness 3 m m wherever required. T h e termination and cable core particulars shall b e painted o n t h e PVC/ nylon sleeves. T h e work also includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply o f PBT terminal blocks 25mm & 60mm centers and P B T Fu s e blocks i s not covered in the schedule) [Wire P V C 3/0.75mm copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm for base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel f r a m e , phynolic sheet 3 m m thick, paint a n d a l l other miscellaneous materials shall be supplied by the Contractor]. b)Termination using P B T fuse block i n cable termination rack (Per Unit = Per Fuse Block)
200.00 blocks w ith 2 B A terminals, a n d wiring of Relay relays as per the approved circuit diagram using wire PVC 16/0.2mm copper. Suitable wire supporting tray with cover made of PVC shall b e provided horizontally and vertically in the relay racks.. While running the wires on the aluminium ladder proper care shall be taken t o provide smooth m a t e r ia ls like rubber beading in the openings on Phynolic sheets, to avoid damage to wires. The work also includes w i r i n g o f contacts f o r data logger and terminating them in tag blocks, provision of relay index board.(Supply o f relays, plug boards, connectors and retaining clips is n o t covered i n this schedule). [Wire PVC
terminals, hard wood plank of size 600mmx 900mmx25mm w i t h decolum finish, MS angles o f size 25mmX25mmX6mm, relay fi x i n g b o l t s and nuts, teakwood plank 25mm thick for fixing resistors and condensers, phynolic sheet 6mm thick of s i z e 1200mmX1800mm with aluminium grooved channel f r a m e f o r relay index b o a r d , p a i n t s , s o l d e r i n g materials, bunching thread, w i r e w o u n d resistance, condenser, wire supporting tray with cover of suitable size made of PVC, paint, varnish a n d a l l o t h e r miscellaneous materials required for the work shall b e supplied by the Contractor]. SALEM DIVISION-S AND T/SOUTHERN RLY
50.00 relays in the relay racks/apparatus cases as Relay per the approved circuit diagram using wire PVC 16/0.2mm c o p p e r. T h e work includes painting alterations a n d releasing the unwanted w i r e s c a r e f u l l y without disturbing the existing wiring.[Wire PVC
bunching threads, condensers, resistances and teakwood plank for fixing them and all other miscellaneous materials required for t h e w o r k s h a l l b e s u p p l i e d by the Contractor].
1.00 708081.12 Highly sensitive smoke aspiration system for Monitoring of rooms and equipment's for earliest possible fi r e detection F o r Relay r o o m sa s p e r R D S O spec No.RDSO/SPN/217/2021 Ver.3.0 or latest.
1.00 311682.08 Fi r e Alarm system w i t h l o o p capacity of connecting maximum 50 devices. The panel shall have a built in power supply and b a t t e r y c h a r g e r R D S O Spec. No.RDSO/SPN/217/2021 Ver.3.0 or latest.
20.00 Optical/ Thermal as per RDSO specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest.
2.00 manual call point with back box (RED) as per RDSO specification No.RDSO/SPN/217/2021 Ver.3.0 or latest.
2.00 to 92 d b A a s p e r R D S O specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest.
1.00 m o d u l e a s p e r R D S O specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest.
2.00 m o d u l e a s p e r R D S O specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest.
1.00 generation & routing in case of Fire Alarm to concerned p e r s o n s a s p e r RDSO No.RDSO/SPN/217/2021 Ver.3.0 or latest.
300.00 unarmoured cable a s per RDSO specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest.
100.00 No.RDSO/SPN/217/2021 Ver.3.0 or latest.
1.00 155660.60 No.RDSO/SPN/217/2021 Ver.3.0 or latest.
1.00 CPVC Pipes with all required accessories for Aspiration system)
2.00 Stainless Steel preventive device w ith UL approved c l e a n g a s w i t h A u t o manual Reverse Stainless Steel valve 'NASA 400 MAR' or similar having capacity of 4kg, and m a d e o f stainless s t e e l 3 0 4 g r a d e with Indian Railway logo put on each unit.
1.00 specification No.RDSO/SPN/217/2021 Ver.3.0 or latest. SALEM DIVISION-S AND T/SOUTHERN RLY
1.00 interfacing t h e Fi r e Alarm a n d Detection systems
1.00 charges o f fi r e a l a r m s y s t e m including programming of devices and fire alarm panel
1.00 C o m m i s s i o n i n g o f A s p i r a t i o n smoke detection
180.00 103.5mm inner d i a & 1 2 0 m m o u t e r dia c o n f o r m i n g t o s p e c i fi c a t i o n N o . IS 14930(Part 2 ) : 2001 with o n e coupler for e v e r y 6 m o f p i p e a s p e r Technical specification
120.00 thick as per Technical specification
1750.00 colour Orange, width o f 250mm (10") by p r i n t i n g w i t h b l a c k l e t t e r s 'Indian RailwaySignal/Telecom/OFC Cable' on both sides
2000.00 mm (inner dia) with couplers
5.00 mountable 2 4 Fibre management system ( F M S ) c o n f o r m i n g t o RDSO/SPN/TC- 37/2000(rev-3 amdt-1 o r latest similar to COMMSCOPE make o r better, suitable for splicing and front patching 24F cable with all accessories and terminating the optical fibre cable with splicing and front patching in FMS in the Location Box. This includes Supply and Provision of 4 nos of Patch cords of required length (All other materials required for splicing are to be supplied by contractor )
1.00 mountable type 19 inch 12U network Rack w ith front glass doo r w i t h l o c k a n d rack fi x i n g multipoint A C P o w e r t r i p & all accessories (Power extension board with one set of MCB, exhaust fan, cable manager)
2.00 Racks of size 1950mm x600mm x 600mm or higher (Make: HCL/ Vero/President/ Rittal/ Puncom or better) complete with all fittings including DC Fans (24V/48V)-2nos, separator sheet/ plate to keep testing equipment-1no and AC power distribution panel ( Horizontal fitting) with power sockets and fuse protection ( min 6 nos of 230V - 15/5A combined and other accessories
80.00 with 4 terminals and stumps with necessary inspection a s p e r specification/ drawing/ description enclosed in this document.
61.44 centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply of PBT terminals 25mm centre. SALEM DIVISION-S AND T/SOUTHERN RLY
100.00 centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply of PBT terminals 60mm centre.
100.00 centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. c)Supply of PBT fuse block without ND fuse
40.00 and fixing on the cable termination rack for indicating "FUSE BLOWN OUT" for each circuit. The LEDs and resistances shall be fixed on a phynolic sheet 50mm width and 3mm thick. The phynolic sheet shall be fixed by the side of the corresponding Fuse Blocks. Separate switch shall be provided for each circuit.[LEDs 10mm, holders, resistance, switch, phynolic sheet, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor].
1.00 e q u i p m e n t c o m p l e t e a s p e r RDSO specification No.IRS.TC@45<47@93 a n d 4 wire control telephone with audio visual indication and r e s e t b u t t o n fi t t e d on telephone conforming to specification No.IRS-TC@45&47@97 or latest.
1.00 diagram board in the station master's room. The board shall be made of Phynolic synthetic industrial fibre base fi n e weave cotton fibre board (matt finish) 6mm thick size 1800mm X 1200mm w ith aluminium channel frame. T h e y a r d layout shall be neatly painted a n d fixed a s instructed by Railway representative at site.[All materials required for the work shall be supplied by the Contractor]. SALEM DIVISION-S AND T/SOUTHERN RLY
1.00 box of size 1000X750X100mm made of 25mm thick teak wood persplex sheet fronted 6mm (Colourless) fixed on the wall at a convenient location as instructed by Railway representative at site. The board should have provision of pad lock and locking arrangements and shall be equipped with the following tools[reputed make]: a. Digital Mulltimeter similar to Model No. Rish Multi 18S with suitable carrying case and test probes. b. Centre zero ammeter 30-0-30 Amps - 1 No. c. Screw drivers of different types and sizes with common handle - 1 set d. Spanner double ended 33mm - 1 No. e. Spanners double ended 3/8x1/2" - 1 No. f. Spanners double ended 5/8x3/4" - 1 No. g. Spanners double ended 7/8x1" - 1 No. h. Hammer 1 1/2 lbs ball pane - 1 No. i. Hacksaw frame - 1 No. j. Adjustable screw spanner 12" - 1 No. k. Insulated cutting pliers- 1 No. l. Insulated nose plier- 1 No. m. Electric soldering iron 230V 60W Soldron/Philips make - 1 No. n. Electric soldering iron 110V 35W Soldron/Philips make - 1 No. o. Megger 500V/ 500Mohms. with Probe- 1 No. The above tools shall be purchased from Reputed manufacturers only in consultation with the Railway representative at site. [Teak wood tool box made o f 25mm teak w oo d plank, perspex sheet, a l l t h e tools m e n t i o n e d a b o v e , p a d l o c k a n d other miscellaneous items shall be supplied by the Contractor].
4.00 and supply of Ni-cad power pack 4V-2.2AH with charger to work on 110VAC
1.00 fronted b o x o f s i z e 300mm x 600mm x 75mm with hooks to keep various keys with description engraved on the tags. [TW Glass fronted box of size 300mmx600mmx 75mm with built in lock, hooks, engraved tags and all other miscellaneous materials required for the work shall b e supplied by the Contractor].
100.00 (Per unit=Per fuse)
1000.00 less than 6mm thick and with an insulation Foot t o withstand 650VAC, o n the floor o f relay room etc at places a s indicated b y railway representative at site."
2.00 termination boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia and 300mm long at the bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each pipe for cable entry and one GI pipe 150mm long 32mm dia for drawl of jumper wires for Point machines etc., fixing of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside and outside with o n e c o a t of red-oxide a n d t w o c o a t s of aluminium paints. SALEM DIVISION-S AND T/SOUTHERN RLY
15.00 machine-IRS t y p e a n d c o n n e c t i n g all ground connections including wiring and termination in p o i n t m a c h i n e and interconnections between point machine and CT box through PVC hose pipe with 3/0.75mm and 7/1.40mm copper wire and painting. This work includes provision of insulation to stretcher bars, throw b a r lug and "D" bracket wherever required, cutting of notches on the point machines covers to suit crank handle configuration.(Combined type point machine with ground connection, uninsulated stretcher bar, throw bar lug and 'D' brackets will be supplied by Railways.[All types of insulations connected to point work, coal bengal, all type of bolts and nuts, washers spring/flat wire PVC 7/1.4mm copper, PVC hope pipe, paints, PVC/nylon sleeves and all other miscellaneous materials required f o r t h e w o r k s h a l l b e supplied by the Contractor].
post (paging and talk back)
5.00 foundations for a width of 0.5m on all sides, up t o a l e v e l 1 5 0 m m b e l o w the foundation top. T h i s w o r k includes consolidation of earth by watering and ramming.The e a r t h s h a l l b e t a k e n from Railway premises as instructed by Railway representative at site.
9.00 foundation as per Drg.No.SG/CN/02/9 using metallic templates, f o r erection o f colour light signals up to 4 aspects.[Foundation bolts, cement, M sand, stone jelly o f size 20/25mm d i a a n d a l l other miscellaneous materials required f o r the work shall be supplied by the Contractor]. SALEM DIVISION-S AND T/SOUTHERN RLY
9.00 mounting o f colour l i g h t signal u p t o 4 aspects complete o n Signal pole/ Off-set bracket, ( f o r L E D / filam e nt b u l b s ) with lenses, triple p o l e l a m p holder, filament switching units, C L S transformer, current regulators (whichever is applicable), fixing of ladder w i t h platform c o m p l e t e and concreting of ladder shoe, fixing of number plates, marker board, lens guard, fixing of s p e e d l i m i t b o a r d wherever necessary, termination o f tail cables, wiring o f signal u n i t w i t h P V C w i r e 3 / 0 . 7 5 m m copper, provision of EWS locks, and painting of one c o a t o f r e d o x i d e a n d t w o c o a t s of aluminium/ enamel paints. When the aspect is fixed on Offset bracket using 'U' bolts and nuts, a through b o l t s h a l l be provided by drilling a hole in the signal pole t o prevent the offset bracket from sliding down.(Supply of surface base, Offset bracket, CLS pole, C L S aspects complete, ladder with shoes and platform, Speed limit board, LED aspects, curre nt regulators, l a m p holders, lamps, filament switching unit and CLS transformer is not covered in this schedule).['U' bolts and nuts, through bolts and nuts, cement, s t o n e jelly 20/25mm dia, M sand, Signal Collar Rings, wire PVC 3/0.75mm copper, lens-guard, all fixing bolts and nuts, lead w o o l , paints P V C / N y l o n sleeves, enameled number p l a t e s . enameled marker boards, EWS locks, and all other miscellaneous materials for the work shall be supplied by the Contractor]."
8.00 foundation a s p e r D r g , No.SG/CN/02/10 using metallic templates, f o r erection of g r o u n d t y p e c o l o u r l i g h t s h u n t signal. [Foundation bolts and nuts, cement, M sand, stone jelly o f size 20/25mm a n d all other miscellaneous materials for the work shall be supplied by the Contractor]."
8.00 complete including surface base, signal pole, LED aspects/ l e n s e s , b u l b s with holders (whichever i s applicable), fixing of lens guards, number plate, termination of tail cables, wiring o f signal unit w ith PVC wire 3/0.75mm copper, provision o f EWS locks and painting of one coat of red oxide and two coats of Aluminium/ enamel paint. ( S u p p l y o f G r o u n d t y p e s h u n t signal complete including surface base, signal pole, LED aspects, holder, bulbs, and lenses is not covered i n t h i s schedule). [Wire PVC 3/0.75mm copper, lens guards, EWS locks, Enameled number plates, bolts a n d nuts, lead wool, paints and all other miscellaneous materials shall b e supplied by the Contractor]." SALEM DIVISION-S AND T/SOUTHERN RLY
7.00 nuts, erection o f Post type shunt Signals, termination o f tail cables and wiring using w i r e P V C 3/0.75mm copper, provision of EWS lock and painting o f one coat o f red- "oxide and two coats of aluminium/ enameled paint. The work also includes drilling suitable holes on the CLS post and provision o f a through bolt with nut to prevent the Off-setbracket from slipping down."
1.00 indicator[Fixing bolts and nuts, EWS locks wires PVC 3/0.75mm & 16/0.2mm copper, wire mesh, PVC/Nylon sleeves, paints and a l l other miscellaneous materials shall be supplied by the Contractor]
1.00 w a y t o 6 w a y s - complete/ fi x i n g of additional l i m b t o t h e e x i s t i n g route indicators, termination of tail cables, wiring as per approved circuits diagram using wire PVC 3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting.(Supply o f junction t y p e Route Indicators - complete and additional limb is not covered in t h i s schedule).[3/0.75mm wire PVC, fixing bolts and nuts, EWS locks, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor]. d)Fixing and wiring o f direction type route indicator - 4 way
13.00 n u t s , erection o f Calling O n Signals/ 'A' marker lights, termination of tail cables and wiring using w i r e P V C 3/0.75mm copper, provision o f E W S l o c k , n u m b e r plates/ marker boards and painting. The work also includes drilling suitable holes o n t h e CLS post and provision of a through bolt with nut to prevent the Off-set bracket from slipping down.(Supply of Calling o n Signal/ ' A ' marker light, L E D aspects/holders & bulbs and Off set brackets is not covered in this schedule).['U' bolts a n d nuts, through bolts with nut, wire PVC 3/0.75mm copper, E W S lock, Enameled number plates, wire mesh, PVC/Nylon sleeves, paints a n d all other miscellaneous materials shall be supplied by the contractor].
2.00 m a s o n r y platform a s p e r d r a w i n g No. SG/CN/02/12 w i t h country bricks o f size 220mmx 100mmx60mm (app) a t t h e foot o f s i g n a l p o s t telephones a s p e r the instructions of Railway representative at site.[Country bricks of size 220mmx100mmx60mm (app), cement, M sand and all other miscellaneous materials required for the work shall b e supplied by the Contractor]. SALEM DIVISION-S AND T/SOUTHERN RLY
10.00 circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.)(Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un-charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). a)Provision of track circuit in RE/Non RE area (point zone)
5.00 circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.)(Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un-charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). b)Provision of track circuit in RE/Non RE area (other than point zone) SALEM DIVISION-S AND T/SOUTHERN RLY
4.00 suit RE/Non R E standard a s p e r approved signaling plan. This work includes provision o f double bonding a n d parallel jumpers, provision o f b o n d w i r e c l i p s , wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track l e a d c o n n e c t i o n s wherever necessary using 2c x 2.5 sq.mm cable. a)Alteration t o existing t r a c k circuits at feed end
4.00 suit RE/Non R E standard a s p e r approved signaling plan. This work includes provision o f double bonding a n d parallel jumpers, provision o f b o n d w i r e c l i p s , wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track l e a d c o n n e c t i o n s wherever necessary using 2c x 2.5 sq.mm cable b)Alteration t o existing t r a c k circuits at relay end
50.00 foundation and erection o f apparatus case f u l l s i z e a s p e r D r g . No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door and another f o r t h e back door, fixing of one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red- oxide and two coats of aluminium paints. (Supply of apparatus case is not included in this schedule).[Foundation bolts & nuts, 'E' type locks, cement, M sand, stone jelly of size 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & nuts a n d a l l other miscellaneous materials required f o r thework shall be supplied by the Contractor.]
20.00 foundation and erection o f apparatus case half size as per Drg, No.SG/CN/02/7, fixing o n e ' E ' type loc k f o r t h e front d o o r and latching arrangement for the back door, and fixing o f o n e hardwood s h e l f plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, 'E' type locks, M sand, stone jelly of size 20/25mm,37mm hard wood planks, latching ""arrangements, paints, varnish, fixing bolts & nuts a n d all other miscellaneous materials required for t h e w o r k s h a l l b e s u p p l i e d by the Contractor]""" SALEM DIVISION-S AND T/SOUTHERN RLY
2.00 termination boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia and 300mm long at the bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each p i p e f o r cable throughing, fixing of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside and outside with o n e c o a t of red-oxide a n d t w o c o a t s of aluminium paints.(Supply of CT boxes is not covered i n this schedule. Rails o f different length shall be supplied b y Railways. The contractor shall cut lengthy rails wherever required.)[Cement, M sand, stone jelly of size 20/25mm, p a i n t , varnish, G I Pipes 32mm dia with clamp nuts - 12mm thick - 2 Nos. for eac h pipe, fixing bolts a n d nuts with washers, E W S locks, paints a n d all other miscellaneous materials shall be supplied by the Contractor].
400.00 existing terminals/ fuse blocks in apparatus c a s e s / batte ry b o x e s / C T b o x e s / cable termination racks a s p e r approved circuit diagram. The terminal particulars are to be repainted /corrected o n t h e d o o r s of apparatus c a s e s / b a t t e r y b o x e s / cable termination boxes and FTOT index board as instructed by Railway representative at site. This work includes closing the opening created f o r e n t r y o f n e w c a b l e s i n the apparatus cases with masonry brick work a n d sealing t h e bottom o f t h e apparatus cases/ cable termination racks w ith cable compound.[Paints, wire PVC 3/0.75mm and 16/0.2mm copper, s e a l i n g compound, brick s, cement, M sand and all other required miscellaneous materials shall be supplied by the contractor].(Per Unit = Per Terminal block) SALEM DIVISION-S AND T/SOUTHERN RLY
8500.00 p o w e r c a b l e s a n d i n t e r n a l w i r i n g on terminal/ f u s e b l o c k s i n n e w apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fi x i n g o f Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each a p p a r a t u s case, varnishing all teakwood items, fi x i n g of terminals/ fuse blocks o n t h e terminal b o a r d , d r i l l i n g of necessary holes, termination o f cables, wiring, identification of cables using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars on sleeves andalso on the inner side of the doors of apparatus cases. After terminations are "over, t h e side openings o f apparatus case foundation s h a l l be closed with brick work, cement plastered, the inter-space filled with M s a n d u p to base level and the bottom surface shall be sealed w i t h sealing compound.(Supply of PBT terminals and Fuse blocks is not covered i n this schedule)." a)Termination o n 25/60mm PBT terminals (new location) (Phynolic sheet)(Per Unit = Per Terminal block)
250.00 p o w e r c a b l e s a n d i n t e r n a l w i r i n g on terminal/ f u s e b l o c k s i n n e w apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fi x i n g o f Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each a p p a r a t u s case, varnishing all teakwood items, fi x i n g of terminals/ fuse blocks o n t h e terminal b o a r d , d r i l l i n g of necessary holes, termination o f cables, wiring, identification of cables using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars on sleeves andalso on the inner side of the doors of apparatus cases. After terminations are "over, t h e side openings o f apparatus case foundation s h a l l be closed with brick work, cement plastered, the inter-space filled with M s a n d u p to base level and the bottom surface shall be sealed w i t h sealing compound.(Supply of PBT terminals and Fuse blocks is not covered i n this schedule)." b)Termination on PBT fuse block (new location) (Phynolic sheet)(Per Unit = Per Fuse block) SALEM DIVISION-S AND T/SOUTHERN RLY
100.00 power cables and internal wiring b y fixing additional terminals/ f u s e blocks o n the existing terminal boards of apparatus cases, cable termination b o x e s e t c . The work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, o n t h e existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall b e closed w i t h b r i c k work, cement plastered, the inter-space filled with M sand u p t o base l e v e l a n d t h e bottom surface s h a l l be s e a l e d w i t h sealing compound. a)Termination o f cables o n 25/60mm PBT terminals (existing location)(Per Unit = Per Terminal block)
10.00 power cables and internal wiring b y fixing additional terminals/ f u s e blocks o n the existing terminal boards of apparatus cases, cable termination b o x e s e t c . The work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, o n t h e existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall b e closed w i t h b r i c k work, cement plastered, the inter-space filled with M sand u p t o base l e v e l a n d t h e bottom surface s h a l l be s e a l e d w i t h sealing compound. b)Termination o f cables o n PBT fuse block (existing location)(Per Unit = Per Fuse block) SALEM DIVISION-S AND T/SOUTHERN RLY
60.00 suitable battery stand i n the battery room using M.S.Angles 65mmx65mmx8mm and MS flats 50mmx6mm c o v e r e d with 100mmx50mm hardwood r e a p e r s , and installation of secondary cells. The work involves charging of secondary cells, fixing and connecting the batteries with strips, manufacture and fixing of teakwood terminal box, termination of cables, wiring w i t h suitable w i r e PVC 7/1.40mm and 3/0.75mm c o p p e r through suitable PVC pipes/ casing properly clamped, provision o f b a t t e r y particulars b o a r d made of phynolic sheet 6mm thick of size 900mm x 1200mm with Aluminium grooved channel frame i n t h e relay room. T h e particulars s h a l l b e d i g i t a l l y u s i n g g o o d quality l a m i n a t e d g u m s h e e t , p r o v i s i o n of hydrometer - 1 No. o n a stand and battery tester-1 N o . Charging o f secondary cells shall b e d o n e b y t h e contractor through reputed agencies.(Supply of secondary cells is not covered in this schedule). a) Provision of battery stand and installation of 2V-300AH cell(Per Unit = Per Cell)
45.00 the following capacities in apparatus cases, connecting them with strips, wiring with wire PVC 3/0.75mm copper and termination. This work also includes charging of cells through reputed agencies. The details of the batteries shall be written on the inside of the doors of the apparatus cases.(Supply of secondary cells is not included in this schedule).[Wire PVC 3/0.75mm copper, connecting strips, paint a n d a l l other miscellaneous materials required for the work shall be supplied by the Contractor]. b)Installation of 2V- 40/80AH cells in apparatus cases(Per Unit = Per Cell)
1.00 Non-Interlocked working of Signals and Points, such as erection and wiring of temporary relay racks and wiring of relays, SM's slide instruments, wiring alterations in the cable termination rack, apparatus cases, signals, Control panel etc, as per the instructions of Railway representative at site.(Supply of relay rack, relays, and SM slide instrument is not included in this schedule).[All other miscellaneous materials required for the work shall be supplied by the Contractor].
3.00 telephone communication at stations/ tents a s p e r t h e in s tru c tio n s o f Railway representative a t site. The P A system and magneto telephones will be returned to the contractor a f t e r t h e completion o f NI working. Signalling cables available may be used for the communication.(Hiring o f PA s y s t e m e q u i p m e n t s and magneto telephones shall be done by the Contractor) [All other miscellaneous materials required f o r t h e w o r k s h a l l b e supplied b y the Contractor]. (Per Unit= Per set per day) SALEM DIVISION-S AND T/SOUTHERN RLY
3.00 sam e a t places a s instructed b y Railway representative at site. The spacing inside the tent shall be app 8ft x 8 ft. Each tent shall be provided with a table, chair, tube lights and pedestal fan. Drinking water in cans.The t e n t s shall be fi x e d fi r m l y to withstand rain, strong wind etc.(Per Unit = Per tent per day)
1.00 required by Railways, wiring it as per circuit diagram and painting o f particulars. The work includes connecting 1 No. of magneto telephone with Ni-cad power pack 4V-2.2AH with charger t o work o n 110VAC and connecting t h e annunciator t o the different telephone circuits. The particulars of the circuits and the ringing codes shall be painted on the top of the annunciator box. (Supply of annunciator is not included in this schedule)."[Magneto telephone handle type with Nicad power pack 4V-2.2AH with charger t o work on 110VAC, w i r e PVC 16/0.2mm copper, paint a n d a l l other miscellaneous materials required f o r the work shall be supplied by the Contractor]."
4.00 Nicad pack
2.00 and painting of boards with 'LEGEND' such as "Draw close if signal is at on" at the required places as per the Signalling plan. The work involves concreting of rail post to a size of 600mm x 600mm x 900mm and fixing the board to the rail using MS clamps, bolts and nuts. (Supply of boards is not covered in this schedule. Rails of different lengths will be supplied by Railways and the Contractor has to cut them to the required lengths) [Stone jelly of size 20/25mm dia, M sand, cement, M.S.flats, fixing bolts and nuts, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor].
5.00 the same in LC/HP/FP Locks/SM slides
3.00 termination r a c k s a l o n g w i t h a l l the terminals, fuse blocks, relays, with jacks, holding clips etc., 50 way boards, terminals, connecting wires, cables etc., carefully without causing any damage, accounting and stacking them neatly at a place as instructed by Railway representative a t site. After releasing, the fl o o r s h a l l b e l e v e l l e d and cement plastered"
2.00 different types including tail cables, carefully without causing any damage, accounting and stacking them neatly at a place as instructed by Railway representative at site. SALEM DIVISION-S AND T/SOUTHERN RLY
5.00 STOP board/Warning board/ LEGEND boards along with rails, accounting and s t a c k i n g them neatly a t a p l a c e as instructed b y Railway representative at site. Also the resultant pits shall b e re- surfaced a n d consolidating by ramming and levelling"
8.00 facing point lock,split stretchers, electrical detector, l o c k b a r s , point/trap indicators c r a n k s , r o d s e t c . , carefully without Damaging the materials, accounting and s t a c k i n g t h e m n e a t l y a t a place as instructed by Railway representative at site.
20.00 Half/ Quarter size) without damage after releasing the shelf planks, Terminal blocks, Fuse Blocks, Terminal Boards, Relays o f all t y p e s E K T s , S e c o n d a r y Cells, power equipments, ' E ' t y p e l o c k s , e t c . , and breaking t h e concrete foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. The released materials shall be accounted and stack e d a t a p l a c e as instructed by Railway representative at site.
10.00 existing c a b l e termination b o x e s , after releasing the base plank, Terminal blocks, Fu s e Blocks, Terminal Boards, c u t rails, pipes, etc., closing t h e resultant pits and consolidating i t b y ramming a n d levelling. The released materials shall b e accounted and stacked neatly at a place as instructed by Railway representative at site.
1.00 including b a s e plank, a n d other gadgets connected very carefully without causing any damage t o the panel, accounting and stacking them neatly at a place as instructed by Railway representative at site. The resultant pit in the flooring shall be removed of all cable bits, levelled and cement plastered
3.00 Colour light Signals complete (upto 4 aspects) with or without Route Indicators, c a l l i n g on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work includes breaking t h e concrete foundation,closing t h e resultant p i t and resurfacing it by ramming and levelling.
2.00 m a c h i n e s ( a l l t y p e s ) in c lu d in g ground connections and other accessories available complete w i t h o u t a n y d a m a g e t o the gadgets, accounting a n d stacking them neatly a t a place a s instructed b y Railway representative at site. SALEM DIVISION-S AND T/SOUTHERN RLY
2.00 frame along with all connected gadgets like lever locks, 'E' type locks, HP locks, etc., accounting and stacking them neatly at a place as instructed by Railway representative at site. The work also involves breaking and removal of concrete foundation and the resultant pit shall be filled and consolidated by ramming and levelling.
1.00 stands available in the battery room along with connecting strips, wires a n d terminal boxes carefully without causing any damage to t h e batteries, accounting and stacking them n e a t l y a t a p l a c e as instructed by Railway representative at site. After releasing any holes i n the walls/ flooring shall b e filled with cement mortar and plastered.
1.00 types), B l o c k counters, batteries, block filter, block bell equipment etc., carefully w i t h o u t a n y d a m a g e , accounting and stacking them neatly at a place as instructed by Railway representative at site
20.00 stumps and terminals after releasing all the bond wires. The released materials shall be accounted and stacked neatly at a place as instructed by Railway representative at site.
1.00 including equipment s t a n d s , terminal boards, power panel e t c . , i n t h e power room carefully without causing any damage t o the equipments after disconnecting all the supply wires. The released equipments shall be accounted and stacked a t a place as instructed by Railway representative at site. After releasing a n y h o l e s i n the walls/flooring shall b e filled w i t h cement mortar and plastered.
1.00 c o m p l e t e including way station equipments, telephones, power supply for w a y station equipment a n d telephones, a l o n g w i t h all wiring, accounting and stacking them neatly at a p l a c e as instructed b y Railway representative at site.
2.00 r o u n d t h e c l o c k t o a t t e n d t h e teething trouble of the installation along with SSE/JE after the installation has been brought into commissioning. T h e work includes routine maintenance, failure restoration as per the direction of the SSE/JE SALEM DIVISION-S AND T/SOUTHERN RLY
30.00 oriented technical manpower t o carryout Days works like Drawing, computation, writeup etc., using computer, using software like AUTOCAD, MS Office etc., for 08.00 hrs in a d a y w i t h all expenses of transportation, accommodation, food, consumables etc., w i t h a l l ascents, descents, taxes, octroi, cess, fees, duties, duties w ith contractors c o s t e t c . , a s per special conditions/ specifications/ regulations and as directed by Engineer-in-charge. Note: The person engaged for providing the services shall be c o n v e r g e n t w i t h computer working knowledge in above software.
120.00 S & T gears by deputation of Days Helpers/Unskilled Labour for executing additional S & T portion o f t h e works. The w o r k can involve fixing, releasing, dismantling, replacement,excavation, clearing of vegetation, loading and unloadingof material and assisting skilled persons etc as per instruction of Railway representative.
60.00 S & Tg e a r sb y d e p u t a t i o n of Days Fitter/Wireman/Painter/Welder/ Mason/Cable Jointer ( S k i l l e d Labour or Technician ) etc., for executing additional S&T portion of works. The work can involve fixing, releasing, dismantling, replacement, painting or alteration o f various signallilng assets or parts, termination o f cables, minor patch work on damages at location box, Plastering, Concreting b r i c k work, wiring alterations, cable jointing etc a s per instruction of Railway representatives at size.
2000.00 r o a d a s p e r t h e instructions o f Railway representative a t s i t e . T h e w o r k also includes loading a n d unloading o f the materials a)Transportation o f Signalling materials upto 100kms
1000.00 than 100km
20.00 or other machineries for regarding and levelling the formation, dismantling any infringing structures, clearing and removing debris etc., w i t h a l l leads a n d lifts etc., complete and a s p e r t h e instruction of Railway representative at site. Total 34888886.94
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .