Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-Finance PLOT NO 28 SANTOSHIMA COLONY WEST MARREDPALLY SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L1 | Accepted-Finance Lowest bidder | |
| 2 | L2₹29.9 L+₹3.2 L (11.9%)Rejected-Finance HOUSE NO 2 4 136 LINGREDDY MANSION BLOCK NO IV OPP HANUMAN TEMPLE TADBUND SECUNDERABAD 500009 | SECUNDERABAD | HYDERABAD | TELANGANA | 500009 | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹36.1 L+₹9.3 L (34.9%)Rejected-Finance | L3 | Rejected-Finance Not L1 |
Tender Value
₹32.9 L
EMD Value
₹65,800
Closing Date
24 Mar 2020, 6:00 pmClosed
CWE (ARMY) SECUNDERABAD
CWE (ARMY) MUDFORT COMPLEX, SECUNDERABAD- 500003
REPAIRS / REPLACEMENT OF UNSERVICEABLE PARTS OF AC PLANTS UNDER AGE E/M NO-II OF GE(U) SECUNDERBAD
2020_MES_317647_2
CWE(S)/UTILITY/TOKEN-34 OF 2019-2020
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Secunderabad
As per NIT
6 documents required · 6 mandatory
₹500
GE(Utility) Secunderabad
₹65,800
Yes
7 Apr 2020
28 Feb 2020
27 Mar 2020
28 Feb 2020
24 Mar 2020
2 Mar 2020
Amount
M&L for Blue star 2x40 TR+1x40TR Scroll compressor chiller type air cooled AC Plant inspection and fault rectification carried out by Manufacturer Engineer for releasing out locking setting the programming for proper functioning of AC plant and to rectify other minor/major problems, including Re-programming & rectify faults occured as and when, with all necessary tools and machines and other major problem & faults (faults either software problem or hard ware) including providing new software if software not working properly with all necessary tools and machines. Note :- i)Transportation & loading charge with hiring of machines and equipments are deemed to be included in quoted rates ii) the rate does not includes material cost,material mesured & piad separately under relavent items) iii).The service Engineer shall be from OEM only.
M&L for Hitachi 4x8.5 TR+2x8.5TR ductable type air cooled packaged AC Plant inspection and fault rectification carried out by Manufacturer Engineer for releasing out locking setting the programming for proper functioning of AC plant and to rectify other minor/major problems, including Re-programming & rectify faults occured as and when, with all necessary tools and machines and other major problem & faults (faults either software problem or hard ware) including providing new software if software not working properly with all necessary tools and machines. Note :- i)Transportation & loading charge with hiring of machines and equipments are deemed to be included in quoted rates ii) the rate does not includes material cost,material mesured & piad separately under relavent items) iii).The service Engineer shall be from OEM only.
Evacuation of gas from each Chiller Unit of 8.5 TR package type System/central type AC plant and leak testing the system by giving the dry nitrogen by separating the low side /high side of the system and arresting the leaks including replacement of Teflon seating of the all refrigerant line, suction/discharge valves of compressor, gland package of all angle valves flaring off and charging complete all as directed by Engr-in-charge. Note :- Quoted rate shall be inclusive cost of nitrogen gas
Description same item No. 3 but for 40 TR(each chiller unit) of AC Plant Chilled system.
S & Fix of 'V' Belts ISI marked suitable for existing one of the following size A-32 to 34.
Description same item No. 5 but for size B-84
Supply and charging the Refrigerant Gas R- 410A complete all as directed by Engr-in-charge.
Supply and charging the Refrigerant Gas R- 407C complete all as directed by Engr-in-charge.
Draining out the old compressor oil from various compressors and supplying, filling/ top up of compressor oil of Freezol-68/ freezol F-57 complete all as directed by Engineer-in-charge.
Servicing and cleaning of Double skin AHU(including blower & existing heat bank strip) unit of capacity 4000CFM including Cleaning of the evaporating coil (AHU coil) with cleaning Acid forced feed method to remove the unwanted dust particles formed on the coil and in AHU unit, cleaning of the filter, greasing to the AHU unit bearing of the structure, expansion valve etc and testing complete all as directed by Engineer-in-charge.
All as per item No.10 above but for AHU Capacity 12800CFM.
All as per item No.10 above but for AHU Capacity 6000CFM.
S&F main switch with HRC fuses of 3 pole with neutral 160A capacity,50Hz,3-Ph, front handle operated including necessary cable connections,nuts bolts complete all as directed by Engr-in-charge. Make: Seimens/L&T/Schneider/ABB
Renewal of unserviceable condenser safety valve 15mm to 20mm ,withstand pressure 300-800 PSI complete all as directed by Engr-in-charge
S & F in Liquid line Filter Dryer suitable for 8.5 TR capacity Compressor unit complete all as directed by Engr- in -Charge. Make for item No.15.00& 16.00: Emerson/Jhonson/Honewell
All as per item No.15 above but for 40 TR capacity Compressor unit complete all as directed by Engr- in -Charge.
Disconnecting the Motor of condenser / Blower/ Chiller/ AHU units from installed position, disconnecting the pump and rewinding the same with super enamelled copper wire of same gauge and turns as per existing, replacement of wornout Bearings fixing back on its original exisiting position, testing and commissioning complete for capacity up to 7.5 hp Note : Transportation charges also included in quoted rate
All as per item No.17 above but 7.5hp to 15hp
Renwal/Replacement to existing unserviceable PCB board(mother board) suitable for exisitng Blue star scroll compressor(compatiable for 4 -compressors air cooled DLT type) chiller plant of capacity 40 TR including installation of suitable software with including talking down old unserviceable one complete all as directed by Engr-in-charge. Note:Installation and commissioning shall be done by OEM only. Make:Suitable for OEM recommended.
Renwal/Replacement to existing unserviceable Display PCB board suitable for existing Blue star scroll compressor(compatiable for 4 -compressors air cooled DLT type) chiller plant of capacity 40 TR including installation of suitable software with including talking down old unserviceable one complete all as directed by Engr-in-charge. Note:Installation and commissioning shall be done by OEM only. Make:Suitable for OEM recommended.
Renwal/Replacement of electronic star delta timer along with LED incations,including talking down old one complete all as directed by Engr-in-Charge. Make:GIC/SEIMENS/Minilec
Renwal/Replacement of single phase preventor with following LED indications 3- phase healthy -ON,phase -loss -OFF including talking down old one complete all as directed by Engr-in-Charge. Make:GIC/SEIMENS/Minilec
Taking out unserviceable MS pipe and Supply,erection,testing &commissioning of New 125mm(5") dia bore, mild steel chilled water piping of class'C",cut to required lenth and installed with welded joints,inclduing all necessary fittings such eblows,tees,bends,reducers,flanges and necessary civil/MS supports,pressure testing etc complete.chilled water pipe insulation shall be with 32mm thich nitrile rubber covered with vapour barrier and finished with 26G alumiunium clading complete all as directed by Engr-in-Charge.
Taking out unserviceable MS pipe and Supply,erection,testing &commissioning of New 75mm(3") dia bore,mild steel chilled water piping of class'C",cut to required lenth and installed with welded joints,inclduing all necessary fittings such eblows,tees,bends,reducers,flanges and necessary civil/MS supports,pressure testing etc complete.chilled water pipe insulation shall be with 32mm thich nitrile rubber covered with vapour barrier and finished with 26G alumiunium clading complete all as directed by Engr-in-Charge.
Taking out unserviceable MS pipe and Supply,erection,testing &commissioning of New 40mm(1.25") dia bore, mild steel chilled water piping of class'C",cut to required lenth and installed with welded joints,inclduing all necessary fittings such eblows,tees,bends,reducers,flanges and necessary civil/MS supports,pressure testing etc complete.chilled water pipe insulation shall be with 32mm thich nitrile rubber covered with vapour barrier and finished with 26G alumiunium clading complete all as directed by Engr-in-Charge. Make for item No.23 to 25: TATA/Jindal
Taking out unserviceable butterfly vlave and Supply,erection,testing &commissioning of New 75mm(3") dia bore, butter fly valves PN 1.0 rating as per latest engineering standards and specifications,fixed with necessary insulation(matching to existing) as required all as specififed and as directed complete all as directed by Engr-in-Charge. Make: Advance/Castle
Taking out unserviceable Globe valve and Supply,erection,testing &commissioning of New 75mm(3") dia bore, globe valves PN 1.0 rating as per latest engineering standards and specifications,fixed with necessary insulation(matching to existing) as required all as specififed and as directed complete all as directed by Engr-in-Charge. Make: Advance/Castle
Taking out unserviceable balancing vlave and Supply,erection,testing &commissioning of New 75mm(3") dia bore, balancing valves PN 1.0 rating as per latest engineering standards and specifications,fixed with necessary insulation(matching to existing) as required all as specififed and as directed complete all as directed by Engr-in-Charge. Make: Advance/Castle
Taking out unserviceable 3-way mixing valve and Supply,erection,testing &commissioning of New 62.5 mm(2.5") dia bore, 3-way mixing valves PN 1.0 rating as per latest engineering standards and specifications,fixed with necessary insulation(matching to existing) as required all as specififed and as directed complete all as directed by Engr-in-Charge. Make: Honeywell/Jhonsons/Siemens/rapid control
Taking out unserviceable NRV and Supply,erection,testing &commissioning of New 75 mm(3") dia bore ,Non -return valves PN 1.0 rating as per latest engineering standards and specifications,fixed with necessary insulation(matching to existing) as required all as specififed and as directed complete all as directed by ENgr-in-Charge. Make: Advance/Audco/Inter valves/Sant
Taking out unserviceable Y-strainer and Supply,erection,testing &commissioning of New 75 mm(3") dia bore, Y-strainer PN 1.0 rating as per latest engineering standards and specifications,fixed with necessary insulation(matching to existing) as required all as specififed and as directed including taking down old u/s one complete all as directed by ENgr-in-Charge. Make:Sant/Advance/Emerald
Suuply,test,install & commissioning of the pressure guage suiatble for existing one as per latest engineering standards and spcifications,fixed with necessary insulations(matching to existing) as required including taking down old u/s one complete all as specified and directed by Engr-in-Charge. Make: H Guru/Sant/Waree
Suuply,test,install & commissioning of the Thermo meter suitable for exisitng one as per latest engineering standards and spcifications,fixed with necessary insulations(matching to existing) as required including taking down old u/s one complete all as specified and directed by Engr-in-Charge. Make:H Gru/Sant/Ware.
Supply,install,test & commissioning of the water flow swtich suitable for existing one as per latest enginnering stanards and specifications ,fixied with necessary insualtion(matching to existing) as required including taking down old u/s one complete all as directed by Engr-In-Chrarge. Make: Honey well/Johnsons/Siemens
Supply,test,install & commissioning of the Auto air vent of suitable size 15mm dia to 20mm dia as per latest engineering standards and specifications,fixed with necessary insulation(matching to exisitng) as required inclduing taking down old u/s one comeplete all as directed by Engr-In-Charge. Make:Amtrol/Anergy/flammcotraders
Supply,test,install & commissioning of the rubber bellow connections for pumps as per latest engineering standards and specifications,fixed with necessary insulation(matching to exisitng) as required inclduing taking down old u/s one comeplete all as directed by Engr-In-Charge. Make: Cori/Easyflex
Supply,install,test& commissioning of Micro bubbler Air & Dirt separators,with matching flanges bolts,Nuts,gaskets,insulation,vlaves and airvent for the size of 150mm dia PN 1.0 including taking down old u/s one complete all as specified and directed by Engr-in-Charge. Make:Amtrol/Anergy/flammcotraders
Supply,test,install & commissioning of 6'x8' laminar flow terminal filter units for OT being made of CRCA/Pre insulated panel material suitable for fixing HEPA filters including HEPA filter,perforated stain less steel sheet in the bottom suitable provision for OT light to be supported being part of the module including taking down old u/s one complete all as directed by Engr-in-Charge. Make: Laminar flow/Sagarair,Make of HEPA:AAF/Fudenburg/Camfil
Supply,install testing and commissioning Suction line with fittings of hard copper piping for condensor units with isulation of 6mm thick nitrile rubber pre formed sections includingsupporting fixtures and accessories etc suitable for Hitache 8.5TR packaged type unit complete all as specified and directed by Engr-in-Charge.
Supply,install testing and commissioning liquid line with fittings of hard copper piping for condensor units with isulation of 6mm thick nitrile rubber pre formed sections includingsupporting fixtures and accessories etc suitable for Hitache 8.5TR packaged type unit complete all as specified and directed by Engr-in-Charge.
Supply,insulation,test and commissioning of under deck insulation for exposed roof of 23mm thickness Class'O' grade XLPE material all as specified and as directed by Engr-In-Charge
M&L for cleaning of existing duct unit along with volume control dampers,fire dampers,collar dampers,intake louvers,bird screen,inscet screen,grills & diffusers and removing dust particles with suitable liquid of OT unit ,MH complete all as directed by Engr--in-Charge
M&L for cleaning of existing duct unit along with volume control dampers,fire dampers,collar dampers,intake louvers,bird screen,inscet screen,grills & diffusers and removing dust particles with suitable liquid of ICU unit ,MH complete all as directed by Engr--in-Charge
Disconnecting & Taking out un servicebale MCCB and S&F of new MCCB 400 Amps, 36 KA, 4 pole, 415 volts, 50 HZ adjustable settings,thermal,magnetic release type suitable fixing for exsting panel and including necessary fixing arrangement for fixing of MCCB to the existing panel connecting cable connections and taking out old u/s one complete all as directed by Engr-in-Charge.
Disconnecting &Taking out old u/s MCCB and supply & fixing of new MCCB 100 Amps, 25 KA, 3pole, 415 volts, 50 HZ , suitable fixing for exsting panel and including necessary fixing arrangement for fixing of MCCB to the existing panel connecting cable connections and taking out old u/s one complete all as directed by Engr-in-Charge.
Disconnecting &Taking out old u/s MCCB and supply & fixing of new MCCB 100 Amps, 25 KA, 4pole, 415 volts, 50 HZ adjustable settings, suitable fixing for exsting panel and including necessary fixing arrangement for fixing of MCCB to the existing panel connecting cable connections and taking out old u/s one complete all as directed by Engr-in-Charge.
Disconnecting &Taking out old u/s MCCB and supply & fixing of new S&F MCCB 160 Amps, 36 KA, 3 pole, 415 volts, 50 HZ adjustable settings, suitable fixing for exsting panel and including necessary fixing arrangement for fixing of MCCB to the existing panel connecting cable connections and taking out old u/s one complete all as directed by Engr-in-Charge.
Disconnecting &Taking out old u/s MCCB and supply & fixing of new S&F MCCB 200 Amps, 25 KA, 4 pole, 415 volts, 50 HZ adjustable settings, suitable fixing for exsting panel and including necessary fixing arrangement for fixing of MCCB to the existing panel connecting cable connections and taking out old u/s one complete all as directed by Engr-in-Charge. Make for item No.44 to 48: L&T/Siemens/Schnieder/ABB/Legrand
Taking out old u/s rotary handle and supply & fixing of new S&F of Exended ROM(Rotary handle) kit suitable for existing one inclding neccesary connections and taking out old u/s one complete all as directed by Engr-in-Charge Make:L&T/Siemens/Schnieder/ABB/Legrand
Supply & fixing of 3 pole power contactor MNX-12,50Hz suitable for existing one and including taking down old unserviceable one complete all as direrected by Engr-in-Charge.
Supply & fixing of 3 pole power contactor MNX-18,50Hz suitable for existing one and including taking down old unserviceable one complete all as direrected by Engr-in-Charge.
Supply & fixing of 3 pole power contactor MNX-25,50Hz suitable for existing one and including taking down old unserviceable one complete all as direrected by Engr-in-Charge.
Supply & fixing of Add on block MNX-A1 for 3 pole power contactor suitable for existing one and including taking down old unserviceable one complete all as direrected by Engr-in-Charge.
Supply & fixing of Add on block MNX-A2 for 3 pole power contactor suitable for existing one and including taking down old unserviceable one complete all as direrected by Engr-in-Charge.
Supply & fixing of DOL MN2 -Thermal overload relay suitable for existing one and including taking down old unserviceable one complete all as direrected by Engr-in-Charge.
Supply & fixing of 4 pole power contactor MCX-12,50Hz suitable for existing one and including taking down old unserviceable one complete all as direrected by Engr-in-Charge. Make for item No.50 to 56: L&T/Schnieder/Siemens
Supply & fixing of analog timer suitable for existing one and including taking down old unserviceable one complete all as direrected by Engr-in-Charge. Make: L&T/GIC/Schnieder/Siemens
Supply and Fix Refrigerent gas R - 22 for AC Plant complete all as specified and directed.
Supply&Fixing of 3 pole MCB,40-63amps,C-curve,10kA,50Hz,440v in existing panel including necessary wiring & misc accessroies for satisfactory completion of job and taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply&Fixing of 3 pole MCB,6-32 amps,C-curve,10kA,50Hz,440v in existing panel including necessary wiring & misc accessroies for satisfactory completion of job and taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply & fixing of 3 pole power contactor CHINT NC1-4011,50Hz suitable for existing one and including taking down old unserviceable one complete all as direrected by Engr-in-Charge. Make:CHINT NC1-4011 or its eqlt in L&T/Siemens/Schneider
Supply & fixing of 3 pole Air break (power) contactor suitable 10-0A,50Hz suitable for existing one and including taking down old unserviceable one complete all as direrected by Engr-in-Charge. Make:Seimens -3TS30 10E or its eqlt in L&T/Schneider
Taking out unserviceable VFD drive from its existing position and Supply,test, install & commissioning of VFD drive of capacity 11kW/15Hp,415volts,3-Ph,50Hz including necessary progamming and software & necessary connections suitable for existing one complete all as directed by Engr-in-Charge. Make: Danfoss VLT micro drive- 132F0058 or its techno commerical equivalent in L&T/Yaskawa/Fuzi
Taking out unserviceable VFD drive from its existing position and Supply,test, install & commissioning of VFD drive of capacity 3.7kW/5Hp,415volts,3-Ph,50Hz including necessary progamming and software & necessary connections suitable for existing one complete all as directed by Engr-in-Charge. Make: Danfoss VLT micro drive- 132F0026 or its techno commerical equivalent in L&T/Schnieder/Yaskawa/Fuzi Note for item no.63 &64: Installation & commissioning shall be done by OEM only.
Taking out unserviceable VVVF drive from its existing position and Supply,test, install & commissioning of VVVF drive of capacity 3.7kW/5Hp,415volts,3-ph,50Hz including necessary progamming and software & necessary connections suitable for existing one complete all as directed by Engr-in-Charge. Make: L&T Cx 2000-LTVF-C40010BAA or its techno commerical equivalent in L&T/Yaskawa/Fuzi Note:Installation & commissioning shall be done by OEM only.
Disconnecting & Taking out old u/s On load change over swtich and supply & fixing of new Onload change over switch 200 Amps,4pole, 415 volts, 50 HZ with &fixing for exsting panel and including necessary fixing arrangement for fixing of change over swtich to the existing panel connecting cable connections and taking out old u/s one complete all as directed by Engr-in-Charge. Make: L&T/Schniedier/Siemens
Taking out old u/s handle kit and supply & fixing of new Operating Handle Kit (handle + shaft+ center bush)suitable for 200 Amps on load change over swtich existing one inclding neccesary connections and taking out old u/s one complete all as directed by Engr-in-Charge Make:L&T/Siemens/Schnieder/ABB
Taking out unserviceable chilled water inlet sensor & supply and fixing of new chilled water sensor complete all as directed by Engr-in-Charge.
Taking out unserviceable chilled water outlet sensor & supply and fixing of new chilled water sensor complete all as directed by Engr-in-Charge.
Disconnecting and taking out unserviceable oil tight limit swtich and S& new Oil tight limit switch complete all as directed by Engr-in-Charge. Make:TEKMEC/Honeywell
REPAIRS TO DGQA 12.50 TR AC Plant SM No 198186
Supply and Fix Thermostatic Switch operated on 230 Volts AC Supply suitable for 12.50 TR AC Plant complete all as specified and directed. DGQA AC Plant SM No. 198186
Supply and Fix Coil for loading and un-loading solinoid valve suitable for 12.50 TR AC Plant complete all as specified and directed. DGQA AC Plant SM No. 198186
Supply and Fix Main bearing non end driving for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No. 198186
Supply and Fix Main bearing driving end for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No. 198186
Supply and Fix Connecting rods for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No. 198186
Supply and Fix Discharge reed with springs (set of 4) for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No 198186
Supply and Fix Suction reed with springs (Set of 4) for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No. 198186
Supply and Fix Piston ring( Set of 4) for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No 198186
Supply and Fix Cylinder liner ( Set of 4) for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No. 198186
Supply and Fix Piston for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No 198186
Supply and Fix Gasket set for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No 198186
Supply and Fix Gudgeon pin with bush for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No. 198186
Supply and Fix shaft seal assembly including carbon ring suitable for make ACCEL, Compressor of capacity SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No. 198186
Supply and Fix Thermostatic Expansion Valve suitable for12.50 TR AC Plant complete all as specified and directed. DGQA AC Plant SM No. 198186
Supply and Fix Solinoid valve of existing size and model suitable for 12.50 TR AC Plant complete all as specified and directed. DGQA AC Plant SM No. 198186
Supply and fixing in replacement of crank shaft assembly suitable for 12.5 Ton AC Plant
Station workshop EME AC Plant SM No 181189
Supply and Fix Thermostatic Switch operated on 230 Volts AC Supply suitable for 40 TR AC Plant complete all as specified and directed. Station Workshop EME AC Plant SM No. 181189
Supply and Fix Coil for loading and un-loading solinoid valve suitable for 40 TR AC Plant complete all as specified and directed. Station Workshop EME AC Plant SM No. 181189
Supply and Fix Thermostatic Expansion Valve suitable for 40 TR AC Plant complete all as specified and directed. Station Workshop EME AC Plant SM No. 181189
Supply and Fix Solinoid valve of existing size and model suitable for 40 TR AC Plant complete all as specified and directed. Station Workshop EME AC Plant SM No. 181189
Supply & Fixing following spare parts suitable to RO Plants of capacity 500 LPH-02 Nos including taking down old unserviceable spare parts complete all as specified and directed
Filter for RO Plant 500 LPH
Carbon Sand
40x40 Membrone
Flow meter
Pressure guage
PTMT Ball Valve
Pump NRV of suitable size
UV System
PVC Pipe
Disconnection RAW water feed pump 0.5HP and re-winding,including replacement of unserviceable bearings of suitable size and re-assembling the motor including installation complete all as specified and directed.
Disconnecting High pressure pump 500 LPH and re-winding,,including replacement of unserviceable bearings of suitable size and re-assmbling the motor including instalation complete all as specified and directed.
Mebrane housing for 40x40 RO membranes.
Taking out old blocked GI tubing with all accessories such as Bend, Elbow, Tees, Nipples, sockets, unions, reducers from any position (in trenches/ floors/ walls) and cleaning of the same and refixing in original position with necessry new GI fittings (ISI Marked)(if required) heavy grade and making good with existing surface including if necessary civil works like Brick, cement work etc., for the following dia of pipes complete all as directed by Engineer-in-charge.
(a) 15 mm dia
(b) 20 mm dia
(c) 50 mm dia
Taking out old unserviceable GI pipe line and supply and fixing/ laying GI tubing medium grade laid in trenches/ floors or fixed to walls including necessary GI fittings such as bends, elbows, nipple, sockets, unions, reducers, tees etc and making good with existing surface following dia of pipes complete all as directed by Engineer-in-Charge. Make of GI pipes :- TATA/ JINDAL Note:(i) The rates including GI fittings & fixing/laying of pipe. (ii) Earth work shall be measured & paid separately under relevant items.
(a) 15 mm dia
(b) 20 mm dia
(c) 25 mm dia
(d) 50 mm dia
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in hard/ dense soil for foundation of poles, structures, stay rods, laying of underground cable etc complete all as directed by Engr-in-Charge.
Returning, filling in soils including spreading, leveling, watering and well ramming in layers each not exceeding 25cm thick complete all as directed by Engr-in-Charge
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as directed by Engr-in-Charge.
Supply and spreading of dry river sand in trenches/ transformer yard/ two pole structure yard for cable protection complete all as directed by Engr-in-charge. Note:- Punned thickness only shall be measured for payment purpose.
S&F of 1000 Lts capacity rotational mountain polyethylene water storage water tank tripple layered(cylindrical vertical with closed top) as per IS-1270 - 1989 hoisted including 25 mm dia ball valve brass with polyethylene float and fly nut and fixed in position including necessary platform complete including removing existing unserviceable tank complete all as directed by Engr-in-Charge. Make: SINTEX/POLYCON
S&F GI stop valves 20mm dia,cast copper alloy,screwed down,high pressure,with cruth or butterfly handle,screwed both ends including taking down old unserviceable one complete all as specified and directed by Engr-in-charge. Make:Zoloto/Hindware/Zenith
S&F GI stop valves 15mm dia,cast copper alloy,screwed down,high pressure,with cruth or butterfly handle,screwed both ends including taking down old unserviceable one complete all as specified and directed by Engr-in-charge. Make:Zoloto/Hindware/Zenith
Taking out water sample in clean container and getting the same tested from the “Department of Water and Waste Water Examiner, Institute of Preventive Medicine, Narayanaguda, Hyd” or “NRDC Himayathnagar” for chemical tests complete all as directed by Engr-in-Charge.
Taking out water sample in clean sterilised container and getting the same tested from the “Department of Water and Waste Water Examiner, Institute of Preventive Medicine, Narayanaguda, Hyd” or “NRDC Himayathnagar” for bacterioligical tests complete all as directed by Engr-in-Charge Note for item No 83.00 & 84.00 :- Sample water shall be taken various places MH and adjoing area under AGE EM-II(u) complete all as directed by Engr-in-Charge .
S&F Manifold Wall Needle pins and brass washer including all neccesaary accessories and taking down old unservceable one complete all as directed by Engr-in-Charge
S&F High Pressure IOX Regulator including all neccesaary accessories and taking down old unservceable one complete all as directed by Engr-in-Charge
S&F High Pressure oxygen tail pipe of stainless steel including all neccesaary accessories and taking down old unservceable one complete all as directed by Engr-in-Charge
S&F Oxygen outlets of double lock front mounted including all neccesaary accessories and taking down old unservceable one complete all as directed by Engr-in-Charge
S&F Oxygen flow meters including all neccesaary accessories and taking down old unservceable one complete all as directed by Engr-in-Charge
Supply and fixing of 15mm dia copper pipe including all necessary fittings nuts bolts and clamps for manifold system including taking down old unservceable one complete all as specified and directed.
Supply and fixing of 10mm dia copper pipe including all necessary fittings nuts bolts and clamps for manifold system including taking down old unserviceable one complete all as specified and directed.
Repair/Replacement of ward vacum unit with connected accessories including taking down old unserviceable one complete all as specified and directed.
Repair/Replacement of theatre vacum unit with connected accessories including taking down old unservceable one complete all as specified and directed.
Repair/replacement of adayate valve of size 15mm perole type incl necessary fittings including taking down old unservceable one complete all as specified and directed
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 3 pole, 32-63Amps, 16kA, 415volts,50 Hz, suitable for exisitng panel(frame size shall be matched with existing one) for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- L&T/Legrand/Schneider.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 3 pole, 32-63Amps, 25kA, 415volts,50 Hz, suitable for exisitng panel(frame size shall be matched with existing one) for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- L&T/Legrand/Schneider.
Supply & fixing of 4 pole power contactor MCX-23,50Hz suitable for existing one and including taking down old unserviceable one complete all as direrected by Engr-in-Charge. Make: L&T/Schneider/Siemens
Supply & fixing of 4 pole power contactor MCX-33,50Hz suitable for existing one and including taking down old unserviceable one complete all as direrected by Engr-in-Charge. Make: L&T/Schneider/Siemens
Renwal/Replacement to existing unserviceable PCB board(mother board) suitable for exisitng Hitachi scroll compressor(compatiable air cooled packaged Ductable type) chiller plant of capacity 8.5 TR including installation of suitable software with including talking down old unserviceable one complete all as directed by Engr-in-charge. Note:Installation and commissioning shall be done by OEM only. Make:Suitable for OEM recommended.
Supply&Fixing of capacitor duty contactors rating 20kVAR to 25 kVAR ,50Hz,440v,3-ph,3-pole in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make: Schnieder cat no. LC1DMK11 or its techno commerical equivalent in L&T/Seimens
Supply&Fixing of capacitor duty contactors rating 10kVAR to 15 kVAR ,50Hz,440v,3-ph,3-pole in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make: Schnieder cat no. LC1DFK11 or its techno commerical equivalent in L&T/Seimens
Supply&Fixing APFC relay 8 stage in existing panel including including necessary wiring,programming & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make: L&T/HPL/Schneider
S&F in MS Pipe line laid in trenchs/duct/ug/surface/wall/floor alongwith aluminium Cladding insulation including following accessories complete all as directed by Engr-In-Charge at the Loundry Plant at Military Hospital
2 1/2" MS C Class Pipe
2 1/2" MS T/E Flanges
2 1/2" MS Long Bends
25mm C Class Pipe
25mm T/E MS Flange
1"x 6" MS long Bends
1"x 6" MS Nipples
1" Elbow
1" Steam Traps
1" MS Union
1" Axe Nipples
Bolts and Nuts suitbale to existing Pipes at Loundry plant , MH
1/2" Teflon tapes
1" globe valves
Welding Rods
Metallic Sheet
Cutting Wheels
Supply and fixing in replacement of following spare parts suitable to Oil fired incinerator capacity 60 Kg/ Hrs automatic waste feeding system fuel tank including taking down old unserviceable spare parts complete as under
M&L for Diesel Mono block fully automatic burners of Cat part No LO -20 including necessary spare ie, Sequence control, Ignition coil, transformer including necessary accessories. Make : Alfa Therm or its techno commercial equivalent make approve by GE
Material & labour descaling of Primary Chamber 800 Degree Centigrade + 50 Degree Centigrade by Hydro chloric acid 33% concentration till the scaling is removed and cleaning of the chamber with fresh water.
Material & labour descaling of Secondary Chamber 1050 Degree Centigrade + 50 Degree Centigrade by Hydro chloric acid 33% concentration till the scaling is removed and cleaning of the chamber with fresh water.
Material & labour descaling of Secondary Chamber- static solid hearth mild cleaning by new technology method of the chamber with fresh water.
Repair & Replacement and servicing of automatic through hydraulic Ram pusher, hydraulic power pack.
Dismantling/Removing of oil fired incinerator Ventury Scribbing System ID Fan winding from motor, re-winding and Re-assembling the original position
Dismantling/Removing of FD Fan of Oil fired incinerator winding from motor, re-winding and Re-assembling the original position
omsai thermax engineers
bethelenterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .