Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.8 LAccepted-AOC | L1 | Accepted-AOC Acceptance of tender | |
| 2 | L2₹54.2 L+₹5.3 L (10.8%)Rejected-Finance 274 A 5TH LANE NISHATGANJ LUCKNOW UP PIN 226007 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226007 | L2 | Rejected-Finance Being Higher bid | |
| 3 | L3₹57.5 L+₹8.6 L (17.6%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L3 | Rejected-Finance Being Higher bid | |
| 4 | L4₹61.0 L+₹12.1 L (24.8%)Rejected-Finance 548 C 259 CHANDRODAYA NAGAR DEOPUR PARA LUCKNOW 226017 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226017 | L4 | Rejected-Finance Being Higher bid | |
| 5 | L5₹62.0 L+₹13.1 L (26.8%)Rejected-Finance 261 BHARAT NAGAR BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L5 | Rejected-Finance Being Higher bid |
Tender Value
₹78.4 L
EMD Value
₹1.4 L
Closing Date
20 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE LUCKNOW
HQ CWE Lucknow, 229 MG Road, Lucknow Cantt, Lucknow-226002
PROVISION OF HIGH MAST LED TYPE WITH ALL CONNECTED ACCESSORIES AT CERTAIN SCATTERED LOCATIONS UNDER GE E/M LUCKNOW
2022_MES_526793_2
CWE/LKO/EM/T-12 OF 2022-23
Open Tender
Civil Works - Others
Item Rate
120 days
Lucknow
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE E/M Lucknow
₹1.4 L
Yes
20 Aug 2022
8 Jul 2022
22 Jul 2022
8 Jul 2022
20 Jul 2022
15 Jul 2022
8 Jul 2022 - 15 Jul 2022
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and exceeding 1.5 m, but not exceeding 3.00 m, in depth for foundations laying of cable etc. and getting out complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick with soft/loose soil.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete all as specified & directed by Engr-in-Charge.
M&L laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified & directed by Engr-in-Charge.
M & Laying, jointing and testing LT under ground electric power cable crossed linked polyethylene (XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 25 sqmm cross sectional area, 4 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
M & Laying, jointing and testing LT under ground electric power cable crossed linked polyethylene (XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 16 sqmm cross sectional area, 4 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
Boring / drilling (Horizontly ) manually/using machines under existing road Max 10 M in width suitable for passing GI tubing 80 mm bore complete all as specified and as directed by Engr-in-charge.
S& F of Mild steel galvanized tubes light grade ISI marked 40mm bore laid in trenches / road crossing/ fixed to pole /walls/path/drain/floor etc all as specified and as directed by Engineer-in-Charge.
S& F of Mild steel galvanized tubes light grade ISI marked 80mm bore laid in trenches / road crossing/ fixed to pole /walls/path/drain/floor etc all as specified and as directed by Engineer-in-Charge.
Taking down of old unserviceable flood fitting any size and capacity and fixing of new LED flood of any capacity complete all as directed. Note: New LED flood light shall be measured and paid seprately under supply only.
S&F in replacement wheather proof pole mounting junction box, base and door of junction box made out of SMC having outside dimention 333x233x120mm, inside dimention 300x200x105mm , single door front openable provided with hinged cover and locking arrangements with 4 Nos aluminium bas bar 63 Amps, mounted on porcelin insulator including M&L for MCB SP 10-1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of junction box body Complete all as directed by Engr-in-Charge
Supply drawing, connecting and testing in replacement 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed` copper conductor (flexible ) industurial cable, 1100 Volts conforming to IS 694 in steel tubular poles from Junction box to floof light fitting including providing suitable copper lugs all as specified and directed by Engr-in-charge.
Earthing in replacement complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by mean of GI wire 4 mm dia by means of bolts, nuts check nuts and washers of GI or steel and connecting to earthing test point, main switch board, testing on completion including PCC cover and frame, PCC (1:3:6) type C-2 as in earthing pit, MS funnel with wire mesh GI pipe 20 mm dia light grade for watering and GI pipe 15 mm dia light grade for the protection of GI wire from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 3 SSR Part-I. PCC chamber shall be constructed at least one metre away from the earth pit and GI pipe fittings for watering shall be provided up to chamber and cost of the same is deemed to be included in the rate of earthing.
Supply, erection and installation of 16 Mtr High mast shaft of approved make with raising system hot dip, having pole sheet thickness 3mm,Top dia minimum 150mm, Bottom dia 360mm, base plate 32mm thick, designed for wind speed 47 m / sec as per IS 875 part- III with head frame, winch mounting bracket, luminaries carriage suitable to install 08 nos of 200 watt flood light. Luminaries in symmetrical arrangement with raising lowering system comprising in double drum winch, 6mm diameter SS wire rope, trailing cable, connector, suitable integral tool motor 1.5 HP, manual handle, junction box, lightening funnel including wiring material from junction box to individual luminaires with MCBs in base compartment. Contd/-
Contd...... Foundation bolts (M30x850mmx8 Nos) shall be of hot dip galvanized steel with high tensile strength along with nuts, washers, anchor plate and common template, suitable of LED type single dome aviation obstruction light including outdoor stand mounted feeder pillar, IP 55 made with 3.15 mm thick CRCA sheet including 01 Nos 32 Amps TPN MCB as incomer, single dial timer switch, 22 Amp TP contactor for the automatic switching of luminaries, power tool control with 02 Nos 9 Amp contactors and raise lower push button of incoming 35 Sqmm and outgoing 16 & 2.5 sq mm terminals and including construction of shallow foundation with M-25 grade concrete for the high mast considering the safe soil bearing capacity at site as 10 T/Sq mtr at 2 meter depth. The cost of construction of RCC foundation including material shall be deemed to be included quoted unit rate. Note : 1. Design, drawings and all data sheets for the foundation and highmast/pole work shall be submitted to GE for approval prior to execution of work. Cost of this provision shall be deemed to be inclusive in quoted unit rate. 2. Fixing of LED flood light shall be deemed to be inclusive in quoted unit rate. LED Lights shall be measured and paid seprately under supply only.
Supply, erection and installation of 12.5 Mtr High mast shaft of approved make with raising system hot dip, having pole sheet thickness 3mm,Top dia minimum 150mm, Bottom dia 310mm, base plate 25mm thick, designed for wind speed 47 m / sec as per IS 875 part - III with head frame, winch mounting bracket, luminaries carriage suitable to install 04 nos of 120 watt flood light. Luminaries in symmetrical arrangement with raising lowering system comprising in double drum winch, 6mm diameter SS wire rope, trailing cable, connector, suitable integral tool motor 0.75 HP, manual handle, junction box, lightening funnel including wiring material from junction box to individual luminaires with MCBs in base compartment. Foundation bolts (M30x850mmx8 Nos) shall be of hot dip galvanized steel with high tensile strength along with nuts, washers, anchor plate and common template, suitable of LED type single dome aviation obstruction light including outdoor stand mounted feeder pillar, IP 55 made with 3.15mm thick CRCA sheet with 01 Nos 32 Amps TPN MCB as incomer, single dial timer switch, 22 Amp TP contactor for the automatic switching of luminaries, power tool control with 02 Nos 9 Amp contactors and raise lower push button of incoming 35 Sqmm and outgoing 16 & 2.5 sq mm terminals. Contd/-
Contd............and including construction of shallow foundation with M-25 grade concrete for the high mast considering the safe soil bearing capacity at site as 10 T/Sq mtr at 2 meter depth. The cost of construction of RCC foundation including material shall be deemed to be included quoted unit rate. Note : 1. Design, drawings and all data sheets for the foundation and highmast/pole work shall be submitted to GE for approval prior to execution of work. Cost of this provision shall be deemed to be inclusive in quoted unit rate. 2. Fixing of LED flood light shall be deemed to be inclusive in quoted unit rate. LED Lights shall be measured and paid seprately under supply only.
Supply only LED flood light luminaire with a of non corrosive high pressure ADC with corrosion resistant powder coating and anti dust exposed lense to ensure protection heat resistant toughened glass provide with silicon gasket for efficient ingress protection.The luminaires should have CRI > 70,SDCM<5 and CCT of 5700K and shall be compliant with IP66 and IK08 classification,Luminaires shall be designed to emit at least 23500 lumens with maximum system wattage of 200W at a system efficacy of at least 120Lm/W.The luminaire shall be designed so as to ensure lumen depreciation of upto 30% over 50k burning hours @ design ambient temp 35 deg C. The luminaire should have fins on the back to ensure good heat dissipation and prevent dirt from setting on the luminaires along with aiming angle scale.The electronic driver should be fully integrated and shall have a power factor >0.95 and THD<10% with a mininimum inbuilt surge protection of 4kV internal & 10kV/kA external and suitable for operating range 140-270 AC & operating temperature range -10 degree c to 50 degre.The driver should be BIS approved,fully potted and encapsulated with 440V high cutt off : 325 V (+/- 15 V) and auto restart function should be avalaible in luminairies and Stress voltage protection for 8hrs.The luminaire should comply with all the required IEC and IS standards. Note: Sample of luminaire shall be submitted to Engr-in-Charge alongwith technical specifiactions for approval of GE before procuring the lot of luminairies.
Supply only LED flood light luminaire with a of non corrosive high pressure ADC with corrosion resistant powder coating and anti dust exposed lense to ensure protection heat resistant toughened glass provide with silicon gasket for efficient ingress protection.The luminaires should have CRI > 70,SDCM<5 and CCT of 5700K and shall be compliant with IP66 and IK08 classification,Luminaires shall be designed to emit at least 14500 lumens with maximum system wattage of 120w at a system efficacy of at least 120Lm/W.The luminaire shall be designed so as to ensure lumen depreciation of upto 30% over 50k burning hours @ design ambient temp 35 deg C. The luminaire should have fins on the back to ensure good heat dissipation and prevent dirt from setting on the luminaires along with aiming angle scale.The electronic driver should be fully integrated and shall have a power factor >0.95 and THD<10% with a mininimum inbuilt surge protection of 4kV internal & 10kV/kA external and suitable for operating range 140-270 AC & operating temperature range -10 degree c to 50 degre.The driver should be BIS approved,fully potted and encapsulated with 440V high cutt off : 325 V (+/- 15 V) and auto restart function should be avalaible in luminairies and Stress voltage protection for 8hrs.The luminaire should comply with all the required IEC and IS standards. Note: Sample of luminaire shall be submitted to Engr-in-Charge alongwith technical specifiactions for approval of GE before procuring the lot of luminairies.
M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by mean of 32X6 mm strip by means of bolts, nuts check nuts and washers of GI or steel and connecting to earthing test point, main switch board, testing on completion including PCC cover and frame, PCC (1:3:6) type C-2 as in earthing pit, MS funnel with wire mesh GI pipe 20 mm dia light grade for watering and GI pipe 40mm dia light grade for the protection of GI strip from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 3 SSR Part-I. PCC chamber shall be constructed at least one metre away from the earth pit and GI pipe fittings for watering shall be provided up to chamber and cost of the same is deemed to be included in the rate of earthing.
M/S S.B. Singh and Sons
Unnati Engineers
M/S National Electrical and Electronics Services
Surindera Kumar Bansal
BHARAT MULTITECH INDUSTRIES PVT LTD
SAKSHAM BUILDERS AND ENGINEERS
Electromech Engineers
M/S ANIL KUMAR
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .