Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹36.9 L+₹5.0 L (15.7%)Rejected-Finance 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹38.9 L+₹7.0 L (22.0%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹41.0 L+₹9.2 L (28.8%)Rejected-Finance 852 EKTA VIHAR 1 C NEAR ANAND NAGAR 9 B PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹41.6 L+₹9.7 L (30.6%)Rejected-Finance | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
Refer Docs
EMD Value
₹95,400
Closing Date
21 Mar 2024, 6:00 pmClosed
LT COL SANDEEP KUMAR
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
SPL REPAIR TO LOGISTIC SECTION FEEDER PILLAR BOXES ,LT CABLES ,LT EQPTS AND PROVN OF DEFI EXHAUST FANS GEYSER AND INSTALLATION OF COMMUTATED AERIAL DIRECTION FINDER UNDER GE (N) PATIALA
2024_MES_643671_1
GE (N)/TOKEN-94/2023-2024
Open Tender
Civil Works
Works
180 days
PATIALA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE NORTH PATIALA
₹95,400
Yes
28 Mar 2024
22 Feb 2024
23 Mar 2024
22 Feb 2024
21 Mar 2024
7 Mar 2024
Amount
Excavating over areas in soft / loose soil, n exc 1.5 m deep and getting out complete all as specified and as directed.
M & L for Plain cement concrete 1:4:8 , type C-2 (using 40mm graded crushed stone agg) in foundation filling and mass concrete complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick each, complete all as specified and as directed.
Removing of surplus soil/ excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Filling of winning earth under floor incl. spreading and levelling, ramming, watering complete all as specified and as directed.
M & L for Brick work with sub class B bricks straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed.
M & L for TMT deformed steel bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
M & L for TMT deformed steel bars, 6mm dia and over upto and including 8mm dia as in stirrups, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
M & L for Reinforced cement concrete (nominal mix) 1:2:4 type B1 (20mm graded aggregate) Slabs supported on walls,beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M & L for Reinforced cement concrete (nominal mix) 1:2:4 type B1 (20mm graded aggregate) Beams, cantilevers, bressumm?ers, lintels over 1.5m span complete all as specified and directed
M & L for Reinforced cement concrete (nominal mix) 1:2:4 type B0 (12.5mm graded aggregate) chajja, kerbs or mud stop or on edges complete all as specified and directed
Use & waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter with rough finished surfaces of concrete complete all as specified and as directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail?ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon?tal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed
M&L rendering 10 mm thick on fair faces of brick walls or concrete surfaces in CM 1:6, to be finished even and smooth (without using extra cement), complete all as specified and directed.
M&L rendering 5 mm thick in CM 1:3 on concrete surfaces of ceiling complete all as specified and directed.
M&L rendering 15 mm thick on fair faces of brick walls or concrete surfaces in CM 1:4, mixed with liquid water proofing @ 200ml per bag of cement, finished even and smooth without using extra cement, complete all as specified and directed. NOTE: WPC shall be measured and paid separately.
Supply only Liquid water proofing compound complete all as specified and directed.
M & L for Providing and laying 3mm thick APP (Atactic Polyproplene Polymer) modified prefabricated five layer, weight not less than 4.0 Kg/Sqm water proofing membrane black finished, reinforced with non-woven polyster matt make as approved including of a coat of bitumen primer @ 0.40 ltr/sq.m by the same membrane manufacturer of density 0.87 to 0.89 Kg/Ltr at 25 degree C temperature and viscosity 70 - 160 cps Over the coat, 3mm thick 5 layered APP membrane shall be laid using butane torch and sealling all joints, overlaps of joints shall be 75mm longitudnal and 100 mm on transverse direction etc after the surface complete as per standard practice as per manufacturers instructions. The vital physical and chemical parameters of the membrane shall be as under - (i) Joint strength longitudnal and transverse direction at 23 degree C as 650/450N/5cms (ii) Tear strength in longitudinal and transverse direction as 300 / 250 N/. Softening point of membrane not less than 150 degree C Cold flexibility upto 20 degree C when tested in accordance with ASTM (D05147) (iii) The laying of membrane shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed.
M & L Precast PCC plain factory made tiles, ISI marked, 22 mm thick of size 250 mm x 250 mm, fabricated using grey cement & no pigments. on 15 mm thick cement mortar (1:3) bedding and joints grouted flush in cement mortar (1:3) mixed with integral liquid water proofing compound over roof surfaces complete all as specified.
M&L 20 mm thick screed bed in CM 1:4 for laying floor finishes complete all as specified and directed by Engr-in-Charge.
M&L 75 mm thick Cement concrete type D- 2, 1:4:8 (40mm graded aggregate), complete all as specified and directed.
M&L 100 mm thick Cement concrete type B- 2, 1:2:4 (40mm graded aggregate), complete all as specified and directed.
Providing machine cut Kota stone slab flooring 18-20 mm thick laid over 20mm thick cement mortar 1:3 screed bed laid and jointed with grey cement slurry mixed with pigments to match the shade of the slab including rubbing and polishig to mirror finish complete to be fixed in any position as described and specification.
M&L for Powder coated (Minimum thickness of powder coating 50 micron) Anodised aluminium frames and shutters for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engineer-in-Charge.
S&F stainless steel (304 grade) finished butt hinges 125mm complete all as specified and directed
S&F powder coated aluminium tower bolt 200mm long complete all as specified and directed.
S&F powder coated aluminium handles 150mm complete all as specified and directed.
S&F powder coated aluminium hook and eye of suitable length adjustable to aluminium window shutters complete all as specified and directed.
S&F tinted sheet glass ordinary quality 4mm thick area n.exc 0.50 sqm each pane complete all as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and 1.40mm avg width of aperature complete all as specified and directed.
S&F 12mm thick high density fibre board pre-laminated on both sides (water proof) below & above middle/lock rail in powder coated aluminium doors and to be fixed with and including EPDM gasket to render the glazing, air and water tight etc aluminium beads 20 mm size with and complete all as specified and directed by Engr-In- Charge
M&L 2 coats of OBD over a coat of primer complete all as specified and directed.
M&L for preparation of new plaster surfaces and applying two coat of cement base paint over priming coat incl a coat of 2mm thick wall care putty complete all as specified ands directed.
M&L 50 mm thick Cement concrete type C- 2, 1:3:6 (40mm graded aggregate) as in plinth protection, finished the concrete surface even and smooth W/o using extra cement, complete all as specified and directed.
M&L Broken stone Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified and directed.
M&L for 100mm thick PCC 1:4:8 type D-2 using 40mm graded stone agg as in a sub base of floors/ path complete all as specified and directed.
M&L for machine pressed precast concrete inter locking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness made of M-35 grade concrete with grey cement and pigment complete all as sepcified and diected.
Sand filling under floors or in foundations including watering and consolidation.
Dismantling, floor, hearth or wall tiling including CM(bedding (but not backing), removing serviceable tiles to store & rubbish off the premises
M&L 20 mm thick screed bed in CM 1:6 for laying floor finishes complete all as specified and directed by Engr-in-Charge.
M&L for full body , vitrified, stain & scratch resistant, joint free, premium quality coloured tiles 600 X 600 mm and 8-10 mm thick, as in floors/skirting etc. in any pattern of light & dark tiles as approved, set and jointed adhesive of Sika (Ceram Grey) @ 5 Kg/sq.m and pointed in white or coloured cement to match, in floors etc. complete all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified.
Taking down chowkhats or frames (without taking off shutters from the frame) n. exc 1.5 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified.
S&F 5mm thick tinted glass for aluminium windows including EPDM gasket to render the glazing, air and water tight etc and power coated aluminium beeds 20 mm size complete.
S&F aluminium door closer hydraulically regulated designation No. 3, universal type, suitable for door shutters of 851 to 1000mm in width and weight between 61 to 80 Kg complete.
S&F PVC hollow Wall panelling of section sizes 150x10 mm (colour/pattern as approved by Accepting Officer) complete fixed in position in all respect including supply and fixing of all accessories like fasteners/screws/solvent etc all as recommended by manufacturer all as specified.
Demolition of brick work or stone/boulder masonary built in cement mortor including all quoins,arches,pillars etc complete all as specified.
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in Cement mortar 1:4 complete all as specified and directed.
Preparation of new/old plaster surfaces and applying 02 coats of interior emulsion paint (light shade) @ 12 sq.m/litre/2 coats to wall surfaces over & including a coat of interior wall primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion, complete all as specified and directed.
Supply and fix Exhaust fan AC single phase 230/240 volt made of sturdy Engineering plastic complete with louvers shutter, 50 Hz, RPM 1200, Copper winding of sweep 300 mm,electrically connecting with twisted three core PVC insulted unsheathed flexible cord of 0.75 Sqmm copper conductor from ceiling rose to PVC Exhaust fan complete all as specified and directed by Engineer-in-Charge.
Supply and fix Exhaust fan AC single phase 230/240 v of size 300 mm sweep 900 rpm metal body, high efficiency motor, dynamically balanced blade for better performance and corrosion-resistant powder coated metallic finish including Louver,electrically connecting with twisted three core PVC insulted unsheathed flexible cord of 0.75 Sqmm copper conductor from ceiling rose to PVC Exhaust fan complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for sub main wiring two single core PVC insulated and unsheathed FRLSH cable with 1.5 Sqmm multi -strand copper conductor drawing in PVC concealed conduit of suitable dia with 1.5 Sqmm PVC FRLSH copper conductor cable as in earth wire system complete all as specified and directed. Note1: Neccessary cutting chasing wherever required and making good the disturbed surface shall be part of job at no extra cost. Note 2: Two runs of 1.5 sqmm cable alongwith one run of 1.5 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length
S&F Modular switch 1 way, 6 Amps, 1 module, 230 volts complete all as specified.
S&F ceiling rose surface bakelite surface 65 x 50mm 3 terminals all as specified & directed
M&Lmetal flush box, 1 module complete all as specified and directed.
M&L modular cover plate, 1 module complete all as specified and directed.
Material and labour for making hole of suitable size for exhaust fan 300 mm sweep in wall including grouting and making good the disturbed surface complete all as specified and directed by Engr-in-charge. Note: Cost of plastering,painting & cement work is included in this rate.
Supply and fixing earth metal plug and socket single pole and neutral with a two pin and earth plug and socket alongwith one single pole MCB of 20 Amp concealed in wall all as directed by Engineer-in-charge.
Supply and fixing for sub main wiring two single core PVC insulated and unsheathed FRLSH copper conductor cable with 4 Sqmm multi -strand copper conductor drawing in PVC concealed conduit of suitable dia with 4 Sqmm PVC insulated and unsheathed FRLSH copper conductor cable as in earth wire system complete all as specified and directed., Note1: Neccessary cutting chasing wherever required and making good the disturbed surface shall be part of job at no extra cost. Note 2 : Two runs of 4 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length).
Supply,installation and testing of minimum 5 star rated electric water heater (Geyser) metal body storage type of 25 ltrs capacity of Steel tank including 04 nos anchor fastining for mounting geyser and other nut,bolt and washers with 3 core flexible wire of size as recommended by OEM from Geyser to metal plug and socket complete all as specified and directed. Note: cost of NRV and plastering including making good disturbed surface as per exisiting surface shall be deemed to included in quoted rates complete all as specified and directed by Engr-in-charge
Supply and fixing on wall/roof or laid in trench galvanised steel tubing (GI Pipe) 15 mm dia medium grade with all fittings (i e bends,elbow,tees,plug,union etc) and fixed with clamps,wooden plugs etc all as directed .
Supply and fixing Fancy type Bib tap of cast copper alloy with crutch screwed down, screwed for iron pipe of dia 15 mm dia bore pipe complete all as specified and directed..
Supply and fixing Stop valves of 15 mm, cast copper alloy, screwed down, high pressure, with crutch screwed both ends for iron pipe or for unions of dia 15 mm dia all as directed by Engr-in-Charge .
Supply and fixing PVC connections wire impregnated 15 mm bore suitable for hot water with PTMT nuts of length 450 mm of 06 Kg/cm² pressure rating with two sets of mild steel chromium plated adopters,one at each end,suitable for fixing to 15mm dia Gi tubing complete all as directed by Engr-in-Charge.
Cutting/drilling or taping from existing 15 or 20mm dia in position for branch connection of 15mm dia including suitable fitting/fixtures all as directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1,5 mtr in depth for laying of cables errecting of pole including getting out in any kind of soil complete all as specified and directed by Engr-in-charge.
Clean dry sand laid in trenches/ducts for bedding and cushioning to cable, including spreading and leveling complete, all as specified. Note:-(i) Consolidated/punned sand shall be considered for purpose of payment.(ii) Sand shall be same as specified for plastering work.
Taking out old unserviceable LT cable, supply,laying, commissioning and testing or passing through pipe, XLPE insulated, armoured, electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade in duct / trenches for small length for extension/replacement of the defective cable of nominal cross sectional area 10 sqmm 4.0 core including brass compression cable gland, terminal aluminium lugs etc making connection and testing complete all as specified and directed. Note :-(i) Pipes and bricks for protection, mild steel clamp nut and bolts sand cushioning shall be measured and paid separately.
All as per item No. 70 here-in before but for cable of size 4 core 16 sqmm.
All as per item No. 70 here-in before but for cable of size 3.5 core 70 sqmm.
All as per item No. 70 here-in before but cable of size 3.5 core 95 sqmm.
All as per item No. 70 here-in before but cable of size 3.5 core 120 sqmm.
All as per item No. 70 here-in before but cable of size 3.5 core 240 sqmm.
M & L for precast concrete cable covers type 2 flat, size 250mmx150mmx40mm laid dry in trenches for cable protection all as specified and directed by Engineer in Charge.
Material and labour for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate for coping around the pole strut above ground level, foundation of stay etc. including necessary form work and finishing the surface fair and even without using extra cement all as directed and specified
M&L cable jointing kit for 1100 Volt grade cable heat shrink type joint complete with jointing material and ascessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 150 sqmm complete all as specified and directed by Engr-in-charge.
Supply,laying,galvanised steel tubing light grade complete with all fitting of size 40 mm dia for cable protection along with pole across road etc. Complete all as specified and directed by Engr-in-Charge.
All as per item Ser No 79 above but size of pipe 50 mm dia
Boring of holes under road, pavement, hard standing by trench-less technology using ultrasound technique and necessary machine suitable to pass through 40 to 80 mm bore GI tubing and cable etc complete all as specified and directed.
Cutting of walls/hardstanding for laying cable including matching surface with PCC /cement mortar as required complete, all as specified and directed.
M & L for Earthing complete with galvanized earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground to the depth of not less than 2.25 mtr below ground level with top edge of earth plate or a depth not less than 1.50 m below ground level connected to GI strip 32 x 6mm as earth lead by means of galvanized bolts, nuts check nuts and washers and necessary excavation and earth work PCC 1:2:4 type B-1 using 20mm graded brick aggregate for earth pit RCC cover , charcoal & common salt filled in alternate layers funnel with 20mm bore light grade watering pipe, 40mm dia GI pipe light grade for protection of GI strip, wire mesh and connected to earth point including testing on all as specified and shown in electric plate No 3 of SSR part I.
M & L for point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH(FLAME RETARDANT LOW SMOKE AND HALOGEN) single core multi-stranded copper conductor for one light/fan and including pvc cashing caping to be terminated in pressed steel terminal boxes with top cover plate including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor controlled by one switch and/or one regulator including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment required for fitting of flush and junction boxes all as specified and directed (Switches and regulators shall be measured and paid for separately.) ( Wiring shall be done as per colour code in IS for phase, neutral and earth) (In case of Modular: Modular cover plate and metal flush boxes incl in Point wiring) NOTE:-1.The contractor must produce certificate of FRLSH wire as well as on site testing of FRLSH wire. 2.Make of The modular cover plate must be same make of switch/socket.
One light/fan point controlled by one switch 6 amp one way
All as described above but point wiring with 2.5 sqmm single core multi stranded copper conductor PVC insulated & unsheathed cable 1100 volt grade and 1.5 sqmm PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board.
All as per Sl item No 2 above herein before but one socket out let 5 pins 5 Amp on the same board but with other switches complete all as specified and directed.
M&L modular socket, 6A-2/3 pin combined, 2 module complete all as specified and directed.
M&L modular switch 16 Amps, 1 module with indicator complete all as specified and directed.
M&L modular socket 16 Amps, 6 pin, 2 module complete all as specified and directed.
S/fix ceiling rose 65x17mm three terminals complete all as specified and directed.
S&F down 20 watt wall mounted, new generation LED batten fitting length ~ 4 feet with polycarbonate diffuser andextruded thermoplastic body > 90 lumen/watt having correleted color temperature(CCT) of Emitting light 6500/3000 K with CRI of LED >90 . including all fixing accessories & connecting up with PVC insulated twin core flexible copper conductor cable of suitable size complete all as specified and directed by Engr in Charge.
S&F MCB DB double door 240 volts with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting type, drilling holes for incoming and out going cables complete suitable for 8 ways with IP54 protection complete all as specefied and directed. (Note: MCB should be B or C curve as directed by engineer in charge)
S&F MCBs 240/415 Volts 10 KA (B or C curve as directed by engg-in-charge) finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB . (DB will be measured and paid separately under respective items of sch A):-
(a) MCB TPN 40 Amps.
(b) MCB SP 6 to 32 Amps
Supply and fixing for sub main wiring Four single core PVC insulated and unsheathed cable with 4 Sqmm multi -strand copper conductor drawing in PVC cashing caping with 4 Sqmm 2 core PVC copper conductor cable as in earth wire system ,including taking out old wiring complete all as directed.
Earthing complete with galvanised steel earth plate electrode, 600x600 x 6.0mm thick buried directly in ground(earth pit not less than 2.25m deep below normal level) connected to galvanised earth lead wire 4.0mm dia by means of nuts, bolts, & washers of GI as shown in electrical plate No 3 of SSR Part I. Connected to earthing test point testing complete including necessary earth pit chamber PCC 1: 3: 6 type C1, and 50mm thick RCC 1 : 2: 4 chamber cover and with 8mm dia mild steel re-enforcement of 15Cm C/C spacing both ways with a handle made of 8 mm bar for fitting, galvanised iron funnel, wire mash watering pipe GI 20 mm dia light grade, and protection to earth lead shall be provided with GI pipe light grade 15mm dia up to 7.5m from the earth plate electrode, excavation, charcoal and common salt mixed refilling of soil etc complete all as directed.
supply and laying un-reinforced precast concrete cable cover class LV, Type 2, with peak size 250mmx180mmx40mm. complete all as specified and directed by Engr-in-charge.
Supply , laying , jointing and testing XLPE insulated screened armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25 Sq mm 4 Core with aluminum thimble of same size complete all as directed.
SWAMI ENGINEERS
DELTA CONSTRUCTION CO
Arneja Builders
AR CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .