Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC VILL POST MANJHULI PS BAKHITIYARPUR KHUSRUPUR DIST PATNA BIHAR 803202 | NALANDA | BIHAR | 803202 | ₹20.0 L | L1 | Accepted-AOC Lowest quoted |
| 2 | L2₹22.1 L+₹2.1 L (10.5%)Rejected-Finance SHANTI KUNJ CHESIRE HOME ROAD BARIATU RANCHI 834009 JHARKHAND | RANCHI | JHARKHAND | 834009 | ₹22.1 L+₹2.1 L (10.5%) | L2 | Rejected-Finance Other than lowest quoted |
| 3 | L3₹23.4 L+₹3.3 L (16.7%)Rejected-Finance | ₹23.4 L+₹3.3 L (16.7%) | L3 | Rejected-Finance Other than lowest quoted |
| 4 | L4₹23.8 L+₹3.8 L (19.0%)Rejected-Finance | ₹23.8 L+₹3.8 L (19.0%) | L4 | Rejected-Finance Other than lowest quoted |
| 5 | L5₹24.7 L+₹4.7 L (23.4%)Rejected-Finance 119 LANE NO 4 DAYA NAND NAGAR LAWRENCE ROAD AMRITSAR PUNJAB 143001 | AMRITSAR | PUNJAB | 143001 | ₹24.7 L+₹4.7 L (23.4%) | L5 | Rejected-Finance Other than lowest quoted |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
1 Jul 2024, 6:00 pmClosed
Shri Sahil Ratusaria, IDSE
Garrison Engineer Ranchi, 7th Club Road Ranchi, PIN-834001
REPAIR/ MAINT OF CEILING FAN/ EXHAUST FAN/ WALL MOUNTED FAN AND ELECTRIC GEYSERS AT LPH AREA UNDER GE RANCHI
2024_MES_655157_1
8400/1221/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer Ranchi, 7th Club Road Ranchi, PI
Class E Cat b (i)
6 documents required · 6 mandatory
₹500
Yes
GE Ranchi
₹40,000
Yes
31 Aug 2024
21 May 2024
3 Jul 2024
22 May 2024
1 Jul 2024
3 Jun 2024
Amount
S&F Fan condenser, 2.5 Mfd, 240 volts for ceiling/Exhaust fan including PVC clamp
S&F Fan condenser, 4 Mfd, 240 volts for ceiling/Exhaust fan including PVC clamp
M&L hanging only ceiling/exhaust/wall fan and connecting up including provision of cable from ceiling rose or connector to fan
Taking down ceiling/exhaust/wall fan, sealing cable end, dismantling blades and removing fan and blades to store
M&L for painting of ceiling/exhaust fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust
S&F in replacement for down rod suitable for ceiling fans complete all as specified and as directed.
S&F in replacement for ball bearing No-6201/6202/6203 suitable for ceiling/ exhaust fans complete all as specified and as directed.
S&F in replacement for brass GM bush suitable for fan any size complete all as specified and as directed
S&F in replacement for brass clamp, rubber reel insulator, 3 Nos nut bolt , washer and lock pin complete all as specified and as directed.
S&F in repair 2 core PVC insulated copper flexible wire multistranded of size 40/76 mm gauge from ceiling rose to fan connector
S&F in replacement for canopy made of canopy complete with nut bolt for fixing in position suitable for ceiling fans complete all as specified and as directed.
S&F in replacement for top and bottom cover for ceiling fans of any type and any make complete including nuts and bolts complete all as specified and as directed.
S&F in replacement for spindle for ceiling fans of any type and any make complete all as specified and as directed.
S&F in replacement for starter for ceiling fans of any type and any make complete all as specified and as directed.
S&F in replacement for rotor for ceiling fans of any type and any make complete all as specified and as directed.
S&F in replacement for blades for ceiling fans of any type and any make complete all as specified and as directed.
M & L rewinding of ceiling fan of any size with supper enameled copper wire of existing gauge including varnishing and drying complete reassembling & testing complete of size 1200 mm sweep complete all as specified and as directed.
M & L rewinding of ceiling fan of any size with supper enameled copper wire of existing gauge including varnishing and drying complete reassembling & testing complete of size 1400 mm sweep complete all as specified and as directed.
M & L rewinding of exhaust fan of any size with supper enameled copper wire of existing gauge including varnishing and drying complete reassembling & testing complete of size 450 mm sweep complete all as specified and as directed.
M & L rewinding of exhaust fan of any size with supper enameled copper wire of existing gauge including varnishing and drying complete reassembling & testing complete of size 150 to 300 mm sweep complete all as specified and as directed.
M & L rewinding of wall mounted fan of any size with supper enameled copper wire of existing gauge including varnishing and drying complete reassembling & testing complete all as specified and as directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, copper winding . Min air delivery 210 CFM Five star rated with brushless direct current motor (BLDC)
Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep 1 star copper winding and taking down old unserviceable ceiling fan and deposit it to store
S & F for metal body exhaust fan, AC single phase, 240 V of size 225 mm sweep 1380 rpm with louvers including necessary connection and replacement of flexible copper cable from ceiling rose and M&L for making hole and proper finishing the surface as existing before and taking down of old unserviceable fan complete all as specified and as directed
S & F for wall mounted fan, AC single phase, 240 V of size 400 mm sweep 1350 rpm with minimum cmm air delivery rate including necessary connection and taking down of old unserviceable fan and deposit it to LPH yard complete all as specified and as directed
Disconnecting/Taking down defective storage type electrically operated water heater/geyser including disconnecting the water pipe (Cold and hot water) and electrical connection after unscrewing from the wall mounted hold/fastener etc. from the existing location and cleaning /descaling of scale formation in geysers ineer tank assembly by means of scrubing with wire brush etc. including cleaning salvents etc and reassembling the geyser end plate/inspection plate and refixing in original position by hanging screwing with necessary nut bolts and washer and connecting up waters mains (Hot and cold) and necessary electric connection and testing on completion for proper working up to the entire satisfaction of user for its proper performance all as specified and directed.
Taking out the unserviceable heating element of capacity 1.5 KW of any make and S&F new heating element of capacity 1.5 KW all as specified and directed Make : Roxy/Power Pack or equivalent.
All as per Serial Item No. 27 above but of 2 KW for geyser upto 50 Ltrs capacity. Make : Roxy/Power Pack or equivalent.
S&F in replacement of thermostat cut off switch suitable for electrical storage type water heater (geyser) upto 50 Ltrs complete all as directed. Make : Girish/Roxy/Klick
S&F in replacement of heavy stainless steel connection pipe with brass union fitted at both end suitable for connection to 15 mm GI pipe, 450 mm long for hot water including 01 No PVC washer on both ends.
All as per Serial Item No. 30 above but for cold water supply.
Repair of Geyser assembly complete with brazing of brass tube stud, nut bolts and copper tank for a length not exc 5.0 cm in each geyser.
S&F in replacement of neoprene rubber gasket for apparatus plate of inner tank assembly for any make /specifecation of electrical storage type water heater complete all as specified and directed.
S&F in replacement of bottom plate cover of MS sheet to suit the geyser capacity 25 Ltrs including painting to the cover plate with 02 coat of white synthetic enameled paint over a coat of red oxide primer.
All as per Serial Item No. 34 above but for 50 Ltrs
All as per Serial Item No 34 above but new top covers of geyser capacity 25 Ltrs.
All as per Serial Item No. 34 above but new top covers of geyser capacity 50 Ltrs.
S&F in replacement of outer shell/body without bottom cover for 25 Ltrs capacity geyser made of MS sheets duly painted, complete all as directed.
All as per Serial Item No. 38 above but for geyser of capacity 50 Ltrs.
S&F in replacement of inner tank assembly made of copper sheet suitable for geyser of capacity 25 Ltr to match with any make and specifications of electirically operated water storage heater as per ground requirement/existing at site complete all as directed.
All as per Serial Item No. 40 above but for geyser of capacity 50 Ltrs.
S&F in replacement of inner assembly comprising of inlet and outler brass tubes to make syphon inner tank complete with base plate and necessary hardwares suitable for geyser of capacity 25 Ltr of any description/specification complete all as directed.
All as per Serial Item No. 42 above but for 50 Ltrs capacity geysers.
S&F in replacement of indicating lamp green and red in colour of geysers.
S&F in replacement of non return valve to geyser of 15 mm dia. Make :- Leader/ Shakti.
S&F in replacement of glass wool in geyser tank and taking out U/S glass wool as per sample.
S&F in replacement of switch socket combinations 3 pin 15 Amp, piano type.
S&F in replacement of plug top 3 pin 15 Amp.
S&F in replacement of industrial type MCB SP type metal clad plug and socket outlet comprising of MCB SP 16 Amp and making necessary electrical connection, complete all as specified and directed.
S&F in replacement of PVC flexible copper cable 3 core 2.5 sqmm for geyser cord.
S&F in replacement of Stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwd both ends iron pipe or for union and fixed of 15 mm dia. Make :- Leader/Shakti.
S&F in replacement of fusible plug type safety cap for overheating protection suitable for electrically operated storage type water heater of capacity upto 50 Ltr of any specification/description, complete all as specified and directed
S&F in replacement of spring loaded safety valve suitable for electrically operated storage type water heater of capacity upto 50 Ltr of any specification/description, complete all as specified and directed
Supply and install connection testing commissioning of electric Geysers of capacity 25 Ltrs single phase 230 V AC incl required nut and bolts PVC water connection pipe complete all as specified and directed.
M&L point wiring for using 2.5 sq mm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary running of 2.5 sq mm PVC insulated copper conductor FRLS cable as earth continuity conductor along with wiring and connecting to the common eath dolly with approved colour coding as per ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with frame suitable for modular switches all as specified and directed for the following :- (Note- Modular cover plate of any module with all fittings are included in point wiring.) Contractor should make good even distributed wall/surface as before.
All as per Serial Item No. 55 above but with copper conductor cable for one 3 pin socket outlet 15 Amp independent board with cable 4 Sqmm including one run of 2.5 Sqmm copper conductor as earth continuity wire, all as specified and directed
M&L of Spray Painting of geyser after removing old paint and making surfaces smooth for repainting with super enamelled paint of same tint as of original all as required at site of any capacity.
BHARATI ENTERPRISES
Barehar Construction Pvt Ltd
JAYSHREE ENTERPRISES
india trading company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .