Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC VPO BAILLY TEHSIL DALHOUSIE DISTT CHAMBA HP PIN 176303 | CHAMBA | HIMACHAL PRADESH | 176303 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹14.0 L+₹19,160 (1.39%)Rejected-Finance 1ST FLOOR GURJEET MARKET DHANGU ROAD | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹14.6 L+₹81,373 (5.90%)Rejected-Finance NEAR CIVIL HOSPITAL WARD NO 07 VPO CHOWARI DISTT CHAMBA HP 176302 | CHOWARI | CHAMBA | HP | 176302 | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹18.9 L+₹5.1 L (37.0%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹20.3 L+₹6.5 L (47.0%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹21.5 L
EMD Value
₹43,000
Closing Date
1 Jan 2020, 6:00 pmClosed
GE (AF) PATHANKOT
GE (AF) PATHANKOT-145001
COMPREHENSIVE MAINTENANCE TO ELECTRICAL SYSTEM INCLUDING REPAIR/REPLACEMENT OF UNSERVICEABLE WIRING WITH FITTING/FIXTURE , MAINTENANCE OF COOLING APPLIANCES, AT AIR FORCE STATION DALHOUSIE
2019_MES_303211_1
GE/PAF-47/2019-20
Open Tender
Support/Maintenance Service
Item Rate
270 days
GE (AF) PATHANKOT
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) PATHANKOT
₹43,000
Yes
18 Feb 2020
3 Dec 2019
3 Jan 2020
3 Dec 2019
1 Jan 2020
17 Dec 2019
Amount
Repair, maint and making the continuity of supply after rectifying the defects of the electrical items such as tube light fittings,switches, replacement of fuse wires, distribution boards, MCB (light/power), lamp holders (bracket/ pandents/ batten), bell/buzzer, push button, ceiling rose, capacitors and other similar electrical items/fittings etc. including provisioning of small pieces of electrical wire of size 1 sqmm to 10 sqmm single core and length not exceeding 0.50 mtrs complete all as specified and directed by Engineer-in-Charge Note :- (i) any accessories found unserviceable that shall be replaced under respective items of this Sch. (ii) If complaint not completed within the days then Rs 100/- of penelty will recovered for per compalint/per day
Supply and fixing in replacement of Electronic ballast suitable for tube light fitting of 1X 14/18/20/36/40 watts 230 volts with white engineering sleeker white engineering plastic housing complete all as specified and directed by Engineer-in-Charge.
All as per item Srl No 2 here-in-before but 2X 14/18/20 watts 230 volts complete all as specified and directed by Engineer-in-Charge.
All as per item Srl No 2 here-in-before but 2X 36/40 watts 230 volts complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of electronic ballast suitable for CFL fitting 1X9/11/18 watts complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of FTL rod 18/20 Watt 240 volts complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement of FTL rod 36/40 Watt 240 volts complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement of FTL (T-5) rod 14 Watt 240 volts complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement of LED lamp 05 to 10 watts 230 volts 3000 K of cap size B22 & E27 complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement of LED tube light double connection retrofit 20 watt 230 volts complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement of LED tube light double connection retrofit 16 watt 230 volts complete all as specified and directed by Engineer-in-Charge
Comapct flourescent lamp 9 to 18 watts 230 volts complete all as specified and directed by Engineer-in-Charge
Compact fluorescent lamp 36 watts suitable for ressced mounting fittings, 230 volts complete all as specified and directed by Engineer-in-Charge
Lamp holder suitable for LED lamp of 5 to 10 watts as per site requirement or complete all as specified and directed by Engineer-in-Charge
Switch piano flush button single pole one/two way or bell push 5 amps 240 volts complete all as specified and directed by Engineer-in-Charge
Bell electric Ding Dong type 230 volts single pole complete all as specified and directed.
Switch flush type 15 Amps, 240 Volts single pole white finish complete all as specified and directed.
Socket outlet 5 pin, 5 Amps flush type white finish complete all as specified and directed.
Socket outlet 2 in 1, 3 pin, 5/15 A multi purpose flush type 240 V white finish complete all as specified and directed.
Switch socket combination, 5 amps 5 pin flush type, 230 volts.white finish complete all as specified and directed.
Switch socket combination, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts complete all as specified and directed.
Switch Piano modular type, 6 Amp, one way complete all as specified and directed.
Switch Piano modular type, 16 Amp, one way complete all as specified and directed.
Mega bell push Piano modular type, 6 Amp, with indicatorcomplete all as specified and directed.
Socket outlet modular type, 3 pin, 6 Amps, shuttered complete all as specified and directed.
Socket outlet modular type 3 pin, 6/16 Amps shuttered complete all as specified and directed.
Ceiling rose, surface backlite, 65 x 20 mm 3three terminal complete all as specified and directed.
Spring loaded rotary type bipin holder suitable for tube light fittings all as required at site complete all as specified and directed by Engineer-in-Charge
Starter 20/40 W, AC 240 Volts suitable for fluorescent tube light fittings complete all as specified and directed by Engineer-in-Charge
Plastic laminated top sheet cover 3 mm thick of size 5"x5" all as required at site including drilling holes for fixing screws and providing 4 Nos screws with washers for fixing the sheet to sunken box /wooden box. complete all as specified and directed.
Plastic laminated top sheet cover 3 mm thick of size 8"x5" all as required at site including drilling holes for fixing screws and providing 4 Nos screws with washers for fixing the sheet to sunken box /wooden box complete all as specified and directed.
Plastic laminated top sheet cover 3 mm thick of size 11"x9" all as required at including drilling holes for fixing screws and providing 4 Nos screws with washers for fixing the sheet to sunken box /wooden box complete all as specified and directed.
Plastic laminated top sheet cover 3 mm thick of size 13"x11" all as required at site including drilling holes for fixing screws and providing 4 Nos screws with washers for fixing the sheet to sunken box /wooden box complete all as specified and directed.
PVC rectangular switch Board for mounting switches, sockets etc with 3mm thick plastic laminated sheet cover of size 100mmx100mm and 50mm deep , 240 volt complete all as specified and directed by Engineer-in-Charge
PVC rectangular switch Board for mounting switches, sockets etc with 3mm thick plastic laminated sheet cover of size 175mmx100mm and 50mm deep , 240 volt complete all as specified and directed by Engineer-in-Charge
PVC rectangular switch Board for mounting switches, sockets etc with 3mm thick plastic laminated sheet cover of size 200mmx150mm and 50mm deep , 240 volt complete all as specified and directed by Engineer-in-Charge
PVC rectangular switch Board for mounting switches, sockets etc with 3mm thick plastic laminated sheet cover of size 250mmx200mm and 50mm deep , 240 volt complete all as specified and directed by Engineer-in-Charge
PVC rectangular switch Board for mounting switches, sockets etc with 3mm thick plastic laminated sheet cover of size 350mmx300mm and 50mm deep , 240 volt complete all as specified and directed by Engineer-in-Charge
Servicing of exhaust fan Upto 300 mm sweep with two coat of spray painting and rewinding of motor, change of bearing if defected, louvered/shutters including taking down and refixing after satisfactory repaired complete all as directed by Engineer-in-Charge.
Servicing of exhaust fan above 300 to 450mm sweep with two coat of spray painting and rewinding of motor, change of bearing if defect, louvered complete all as dorected by Engineer-in-Charge.
Capacitor 3.15/4 mfd 240 volts for fans complete all as specified and directed by Engineer-in-Charge
Taking down and refixing/relocation of exising tube light fitting, wall bracket or bulkhead fitting including connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 Sqmm 3 core all as per direction or specified by the Engineer-in-Charge
LED bulk head fitting Plastic Body , heat resistant, with specially designed gasket in and including LED lamp 10 watt complete all as per directed by Engr- in -charge.
Building security light fitting of new generation energy saving and environmental friendly long life versatile pressure die cast aluminium housing IP66 LED lumanaire with high power LED 25 watt as light source with toughned glass complete all as specified and directed by Engineer-in-Charge.
Bracket made out of GI pipe 25 mm dia medium grade, 0.9 mtr long bent to shape with welded MS flat 25 x 6 mm for mounting of fitting & MS flat iron clamps made out of 25mmX 6mm thick FI nuts, bolts complete all as directed by Engineer-in-Charge incl taking down old unsv.
Supply and fixing in replacement of LED tube light fitting, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver of 20/22watt (4') in and including 20/22 watt LED complete with all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or directed.
All as per srl item No 46 here-in-above but 12/14watt (2') complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement of Ultra mordern recess mounting flat panel luminaires (2'x2'), 34/36 Watt LED,6000k with seprate electrinic driver & high brightness SMD LEDs including lamp and complete with all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor all as required at site or directed.
Supply and fixing in replacement of Energy saving flood light luminaire high power COB LED as light source with protection IP65 of 50/60 watt LED complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Electronic Meter 10-60 amps Single phase tamper proof with Class 1 accuracy Optical port, LED Indication for earth leakage ,Elegant Polycarbonate Enclosure, anti tamper features, Electro magnetic compatible & 6 digit Display. Make HPL Cat No SPPC15100000000C00 or equivalent in L&T/CG.
Supply and fixing in replacement of Electronic Meter 10-60 amps Three phase tamper proof with Class 1 accuracy Optical port,LED Indication for earth leakage ,Elegant Polycarbonate Enclosure, anti tamper features, Electromagnetic compatible & 6 digit Display. Make HPL Cat No TPPC15100000000C00 or equivalent in L&T/CG.
Supply and fixing in replacement of Indirect up-down light suitable for mirror and as wall light application of 8/10 watt/4000K in and including 8/10 watt LED with all complete fixing accessories and arrangement as required at site complete all as specified and directed by Engineer-in-Charge.
Testing of old earthing using calibrated earth tester & submitting result to engr -in -charge. Earthing which showing much more results as specified in IS rule and disconnetivity should be replaced with new earthing items are considered as below. Note : (i) Watering of earthing with 2 Buckets (30Ltrs) water mixed with salt (total 5 Kg) shall be carried out one day before the testing & the cost of the same shall deemed included in unit rate quoted.
Two coat of spray painting on wall with synthetic enameled paint of black colour of 200 x 150 mm size and writing work for earth test result with date & year all as specified and directed at site by Engineer-in-Charge.
Taking down old unserviceable/deteriorated batten/PVC conduit point wiring from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets, ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar (1 : 3) or plaster of Peris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash all as required and directed by Engineer-in-Charge.
Taking down main switch/DB/ changeover/AC box of any capacity including fixing accessories of single/three phase complete all as specified and directed by Engineer-in-Charge
Taking down old/unserviceable aluminium/copper submain wiring of any size and type complete all as specified and directed by Engineer-in-Charge
Concealed point wiring on wall and surface on ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 0.75 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified for One light, fan, call bell, 5 Amp independent socket point controlled by one switch as directed by Engineer-in-Charge.
All as per Srl item No 58 but for One socket point controlled by one switch on same board complete all as specified and directed by Engineer-in-Charge
All as per item No 58 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead complete all as specified and directed by Engineer-in-Charge
All as per item Srl No 58 here-in-before but point wiring in surface position with casing and caping complete all as specified and directed by Engineer-in-Charge for the following:- One light, fan, call bell, 5Amp independent socket point controlled by one switch.
All as per Srl item No 58 but for One socket point controlled by one switch on same board complete all as specified and directed by Engineer-in-Charge
All as per item No 61 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead complete all as specified and directed by Engineer-in-Charge
Supply and fixing and replacement of Sheet metal enclosure , 32A single pole and neutral with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB 32 Amp fixed properly complete all as directed by Engineer-in-Charge .
Supply and fixing and replacement of Sheet metal enclosure VTPN MCCB DB 4way, 415 V (vertical type) with bus bar double door type IP 43 - IK 09 for DB when MCBs & MCCB 100 Amps (as incomer) to be used, fixed properly on / in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wires complete all as directed by Engineer-in-Charge .
Supply and fixing and replacement of Double door metallic sheet metal enclosure for DB when MCBs to be used TPNL, 4 ways, 415Volts (horizontal type) with 200 Amps rated bus bar suitable for TPN MCB/ 4 pole Isolator fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wires complete all as directed by Engineer-in-Charge .
Supply and fixing and replacement of Double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as directed by Engineer-in-Charge .
All as per Srl item No 67 but DB 4ways complete all as directed by Engineer-in-Charge .
All as per Srl item No 67 but DB 2ways without busbar complete all as directed by Engineer-in-Charge .
MCB SP 240 volt 6 Amp to 40 amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as directed by Engineer-in-Charge .
All as per Srl item No 70 but SP 40-63 Amps complete all as directed by Engineer-in-Charge .
All as per Srl item No 70 but SPN 16-32 Amps complete all as directed by Engineer-in-Charge .
All as per Srl item No 70 but SPN 40-63 Amps complete all as directed by Engineer-in-Charge .
All as per Srl item No 70 but TP 40-63 A 415V complete all as directed by Engineer-in-Charge .
All as per Srl item No 70 but TPN 40-63 Amps complete all as specified and directed by Engineer-in-Charge.
MCCB 100 Amps, 3 Pole, 415V, 25KA complete all as directed by Engineer-in-Charge .
Sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 4 sqmm drawn in MS/PVC conduit with 1.5 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete excluding rigid PVC conduit complete all as directed by Engineer-in-Charge . Note : 2 run of single core cable and one run of earth wire shall be measured as 1 RM.
Sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 6 sqmm drawn in PVC conduit with 2.5 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete excluding rigid PVC conduit complete all as directed by Engineer-in-Charge . Note : 2 run of single core cable and one run of earth wire shall be measured as 1 RM.
Sub main wiring with four single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 6 sqmm drawn in PVC conduit with 1 run of 4 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete excluding rigid PVC conduit complete all as directed by Engineer-in-Charge . Note : 4 run of single core cable and one run of earth wire shall be measured as 1 RM.
Rigid non metallic medium grade white/ivory 20mm dia PVC conduite ISI marked in concealed/surface position inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddlers, pipe hooks etc fixed properly on as in concealed/Surface position all as directed by Engineer-in-Charge .
All as per item No. 80 above but of size 25 mm dia PVC conduit complete all as directed by Engineer-in-Charge .
Cutting chases in brick walls, pinning in at the depth of 10 mm, making good to facings where required and pointing in cement mortar 1:3 cutting chases for concealed conduit wiring,submain wiring etc and making good and palstering the surface with cement or plaster of peris and matching with same colour scheme, cutting not exceeding 10cm girth complete all as specified and as directed by Engineer-in-Charge.
1100 volts grade heavy duty cable PVC insulated aluminium staranded conductor , served with inner sheathed PVC tape and overall PVC sheathed in service connection one twin core flat or circular of size 10 sqmm x 2core complete all as specified and as directed by Engineer-in-Charge.
Dismantling from insulators including taking down ACSR conductor any size from LT overhead lines and depositing to MES store yard complete all as specified.
Dismantling earth wire any size from eye hooks/insulators etc from LT overhead lines and depositing to MES store yard all as specified.
Dismantling insulator any type and any size from LT over head lines and depositing to MES store yard complete all as specified and as directed by Engineer-in-Charge.
Supply and stringing ACSR conductor any size to LT over head lines , stretching properly to achieve proper sag including binding to insulators using GI/aluminium binding wire all as required at site or directed by Engineer-in-Charge.
Galvanized steel wire of size 4mm dia to LT over head line as continuous earth or fabrication of guarding cradles all as specified and directed by Engineer-in-Charge.
Unbinding from insulators ACSR conductor any size of LT over head line for repairs. Restretching of ACSR conductor to achieve proper sag and rebinding to the insulators using aluminium/GI binding wire all as required at site or directed by Engineer-in-Charge.
All as per item srl No 89 above but GI wire all as per specified.
Cutting/trimming tree branches around LT overhead lines to a distance of 01 meter both side from overhead lines or poles after taking proper shut down of electric supply from MES all as directed by Engineer-in-Charge.
Stay assembly set complete with accessories like stay rod/strand/plate ,loop type insulator, clamps, excavation, concreate etc for LT pole any type using necessary T&P as required on site and as directed by Engineer-in-charge.
Pin type porcelain, vitreos, white, brown or green insulators including one galvanized mild steel spindle, two galvanised iron washers and one galvanised iron nut 100mm height, 65mm dia for 1100 volts grade all as specified.
Loop type insulator, vitreous porcelain white brown or green small size with overall dimensions 65x90mm, clearance of hole 16mm for 1100 volts grade all as specified.
Loop type insulator, vitreiys porcelain white brown or green large size with overall dimensions 90x140mm, clearance of hole 25.5mm for 1100 volts grade all as specified.
Aluminium strip 25x3mm complete with saddles/ insulators made out of PVC or fibre and fixing screws for roof conductor/down conductor including welding or brazing for joints all as required at site or directed by Engineer-in-Charge.
Copper strip 25x3mm complete with saddles/ insulators made out of PVC or fibre and fixing screws for roof conductor/down conductor including welding or brazing for joints all as required at site or directed by Engineer-in-Charge.
Street light time switch of size 50 x 50 x 30 cm made out of MS sheet 1.6 mm thick factory fabricated duly powder coated with front door operable heaving pressure lock suitable for and including the followings :- (i) Street light time switch multi functional digital for automatic switching on & off of street lights at a preset time model Astrorex D-21 Cat Pt No 004764 of make MDS or equivalent of Make: L&T, all as required = 01 Nos (ii) Air break contactor AC 415 volts, 50 HZ 3 phase 70 A with operating coil voltage 220 volts conforming to cat pt No CE 15 KN 3 of BCH or cat pt No LCI D-50 of Schneider - 01 No (iii) Bakelite fuse base and carrier with HRC fuses 63 amps 415 V Make : L&T/GE– 04 Nos(v) Bakelite fuse base and carrier with HRC fuses 5 amps 230 V Make : L&T/GE– 02 Nos (iv) All accessories pre wired with suitable size copper conductor cable including making necessary arrangements for fixing to wall / pole / panel all as required at site or directed.
Supplying, laying ,testing and connecting in replacement of XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electrical cable with aluminium conductor, 1100 volts grade, cross-sectional area with suitable lugs of following sizes complete all as specified and directed. 16 sqmm 2 core
All as per Srl item No 99 but 25 sqmm 2 core complete all as specified & as directed by Engineer-in-charge.
All as per Srl item No 99 but 35 sqmm 3.5 corecomplete all as specified & as directed by Engineer-in-charge.
All as per Srl item No 99 but 50 sqmm 3.5 core complete all as specified & as directed by Engineer-in-charge.
All as per Srl item No 99 but 70 sqmm 3.5 core complete all as specified & as directed by Engineer-in-charge.
Excavation in trenches in any type of soil, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, laying of cables and getting out complete all as specified & as directed by Engineer-in-charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm each layer all as specified.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified.
Sand cushioning to under ground cable 8 cm thick layer below the cable and 15cm thick above the cable complete and all as directed & specified.
Brick protection with well burnt sub class ‘B’ brick a butting each other( width wise) across the cable laid in trenches complete and all as specified.
GI pipe light grade of size 40 mm bore for laying in trenches/floors or walls including all fittings for fixing complete as required and directed by Engineer-in-Charge.
GI pipe light grade of size 50 mm bore for laying in trenches/floors or walls including all fittings for fixing complete as required and directed by Engineer-in-Charge.
Battery 12 Volt , 150 AH, dry type with suitable copper connecter terminal lead (positive and negative) for DG set 62.5 KVA complete all as spcified by Engineer-in-Charge.
Battery 12 Volt , 180 AH, dry type with suitable copper connecter terminal lead (positive and negative) for DG set 82.5 KVA complete all as spcified by Engineer-in-Charge.
Portable one battery charger set accommodate with copper connecting +ve/-ve lead terminal, voltage control regulator setector switch of 12 Volt, 24 V,36 V,current control regulator switch, amps meter, electronic fuse, push to reset , AC mains on/off buttons complete as factory made or complete all as specified by Engineer-in-Charge.
Neon indicater lamp set of three (RYB) PVC body with contact block and assembly to be fixed on exsisting panal board complete all as spcified by Engineer-in-Charge.
PVC 1100 volt LT phase seperator/specar for 3 phase 4 wire system incl taking down u/s seperater all as specified by E-in- Charge
PVC 1100 Volts LT phase seperator/specar for 1 phase 2 wire system incl taking down u/s seperater all as specified by E-in- Charge
Supply and installed in replacement ACB 630 Amp TPN, 50 KA 415 volt Microprocessor based (adjustable) fixed type electrical charge complete all as specified & as directed by Engineer-in-charge.
Danger Notice Plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with white letter, figures and conventional skull & bones in signal red colour and fixed with MS clamps, nuts and bolts of approved size, for LT, 20x15cm size complete all as specified & as directed by Engineer-in-charge.
Single core copper multistrandred conductor flexible PVC Insulated heavy duty Industrial cable (unsheathed) 1100 volts size 16 sqmm ( per 100 RM roll) complete all as specified & as directed by Engineer-in-charge.
Load changeover switch in sheet encloser side handle AC 240 volt, double pole 32 amps complete all as specified & as directed by Engineer-in-charge.
Load changeover switch in sheet encloser side handle AC 415 volt, four pole 100 amps complete all as specified & as directed by Engineer-in-charge.
MCCB 4 Pole 415 Volts with rupturing capacity 16 KA 100 Amps fixed type complete all as specified & as directed by Engineer-in-charge.
MCCB 4 Pole 415 Volts with rupturing capacity 16 KA 125 Amps fixed type complete all as specified & as directed by Engineer-in-charge.
Scraping of old paint from the steel tubular/PCC pole 09/11 mtr height with out removing accessories and preparation of surfaces for repainting. Repainting the pole with one coat of alternative black and yellow (existing colour) straps of 30 cm each upto 1.5 mtr height using synthetic enamell paint .Repainting the remaining pole and iron parts i.e U clamps, chanels etc above 1.5 mtr height by applying one coat of alumn paint including writing Pole Nos. with Black paint all as per specified at site and directed by Engineer-in-Charge.
Disconnecting the Split type Air conditioner cap 1.5/2 Ton from Outer unit and repair the followings as required on site & as directed by Engineer-in-Charge :- Servicing the Split type AC cap 1.5/2 Ton, Cleaning of condenser coil unit from Stand and inner unit
Vacuum the compressor unit and testing of leakage and charging Gas of F-22 and topup the Gas F-22
Replacement of capacitor 45 mfd.
Replacement of filter dryer
Replacement sealed Comppresser Unit as per Existing Make. As per sample
Taking out the defective eletronic circuit board or PCB unit indoor unit of split type AC and supply and fix eletronic circuit board for split AC of capacity 1.5 /2TR of any exixting make and model or as per required at site
Taking out only burnt/unserviceable blower motor and replace the same with new (Company sealed) blower motor as per exiting size, specification and Make suitable for AC of capacity 1.5/2 Ton of any make and model as applicable and connectnig up all the system all as directed by the Engineer-in-Charge
Taking out unserviceable evaporator coil and replace the same with new (company sealed) evaporator coil as per size, secification and make suitable for Ac of 1.5/2 ton of any make & model as applicable and connecting up all system with and including charging of refrigment (F-22) and testing complete to the satisfaction of the Engineer-in-Charge
Taking out unserviceable condenser coil and replace the same with new(company new) condenser coil as per exiting size, secification and make suitable for Ac of 1.5/2 ton of any make as applicable and up all the system eith and including charging of refrigrant (F-22) and testing complete to the satisfaction of the Engineer-in-Charge.
Disconnecting the Deep freezer cap 210/300 Ltr and refrigerator cap 165 to 310 Ltrs and repair the followings as required on site & as directed by Engineer-in-Charge :- Servicing the Refrigerator ,Deep freezer, Cleaning of condenser coil unit from Stand and inner unit complete
(b) Taking out unserviceable condenser coil and replace the same with new(company new) condenser coil as per exiting size, secification and make suitable for refrigerator of capacity 180/310 ltrs of any make as applicable with and including charging of refrigerant gas (F-12) and testing complete to the satisfaction of the Engineer-in-Charge.
Vacuum the compressor unit and testing of leakage and charging Gas (F-12)
Replacement of capacitor or starting realy as suitable exsisting capacity.
Replacement of filter dryer pencil of any size
Replacement of cooling fan with electric motor-
Supply and fixng in replacement of compressor(sealed unit) as per existing size specification and make suitable for refrigerator of capacity 180/310 ltrs of any make as applicable and connecting up all the system with and including Relay & OLP and Re- gas charging of refrigerant and testing complete to the satisfaction of the Engineer-in-Charge.
All as per items No 126.6 here in before but for refrigerator of capacity 310 ltrs of any make.
Replacement of defective componants /accessories suitable for refrigerator of capacity 165 ltrs to 310 ltrs of any model and make as applicable and testing complete as directed by the Engineer-in-Charge Freezer complete with freezer door braket suitable for refrigerator of capacity 165 ltrs.
All as per items No 127 above but suitable for 280 / 310 ltrs
Ice tray PVC / Plastic for all models.
Chiller tray suitable for refrigerator of capacity 165 litrs
Thermostat control switch complete with knob and box suitable for refrigerator of capacity 165 ltrs to 310 ltrs as approved.
Table top for refrigerator suiatable for as per exiting size and colour.
Replacment of unserviceable components/ parts such as power circuit board (PCB), time relay, socket outlet, regualtor /toggle switch,Voltmetre , Indicator lamp, circuit wiring fuse unit etc including rewinding of transfarmor &painting voltage stablizer extamally with two coats of synthetic enamal paint after preparation of old painted steel surface and testing all complete for stablizer up to 10 KVA capacity as directed.
Supply only Heigh Strength Calsium based granualar chlorination chemical containing approprate qty of dispersants / corrision inhibitors to prevent encrustation / scalling in distribution system. Thebrand & make of chlorination chemical must be stated and certified by All India Institute of Hygine & Public Health (Govt. of India), conferming compliance to all the above specifications with a declaration from the Laboratory that from the Technical strength, stability, health, safety, and operational point of view, as well as the fact that this product is used for drinking water applications for consumption by humans, the brand and make of calsium based granular chlorination chemical is suitable for drinking wayer chlorination and is recommended for use. the reportmust indicate that the sample has been drawn by All india Institute of Hygine & Public Health. MAKE : All Make approved by NMPT committee of E-in-C's Branch.
Heating element any type 1.5/2.0 KW 240 Volts, ISI marked for water heater storage type complete all as specified.
Thermostat switch 0 to 100°C , 240 volts suitable for water heater storage type any make complete all as specified.
Syphon assy any type for water heater storage type upto 25/50 ltr cap complete all as specified & as directed by Engineer-in-charge.
Inner copper tank any cap for water heater storage type upto 25/50 ltr cap complete all as specified & as directed by Engineer-in-charge.
Outer body suitable for25/ 50 ltr geyser made out of MS sheet factory made complete with fixing bracket matching with existing complete all as specified & as directed by Engineer-in-charge.
Glass wool of 25/50 ltrs capacity geyser complete all as specified and directed by Enginner-in-Charge.
Indicator lamp round/square type suitable for geyser 25/50 ltr all as per sample AC 230 Volt complete all as specified & as directed by Engineer-in-charge.
Hot and cold PVC connection 15mm dia complete with brass flair nuts at both ends. (ISI marked and suitable for hot water supply upto 100 degree celcius) complete all as specified & as directed by Engineer-in-charge.
Brass pressure relief valve chromium plated suitable for geyser 25/50 ltr capacity complete all as specified & as directed by Engineer-in-charge.
Anchor bolt 12mmX100mm long complete all as specified & as directed by Engineer-in-charge. (Note:- Anchor bolt shall be grouted with hammer drill only)
Bottom cover plate of geyser of capacity 25/50 ltr complete with MS screw all as per sample complete all as specified & as directed by Engineer-in-charge.
Stop valve, cast copper alloy, screwed down,m high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions for bore dia of pipe 15mm complete all as specified & as directed by Engineer-in-charge.
Plug top 3 pin 6 amps AC 240 Volts complete all as specified & as directed by Engineer-in-charge.
Plug top 3 pin 16 amps AC 240 Volts complete all as specified & as directed by Engineer-in-charge.
Cord flexible PVC insulated and over all sheathed, 3 core, flexible copper conductor of size 1.50 sqmm, cut to size complete all as specified & as directed by Engineer-in-charge.
As per item No 144 here-in-before but size 2.5 sqmm complete all as specified & as directed by Engineer-in-charge.
Cord flexible PVC insulated , 2 core, (22/0076) flexible copper strandred conductor of , cut to size for connection ceiling rose to fittings and fixture all as required at site complete all as specified & as directed by Engineer-in-charge.
Carbon fiber heating element 1000 watt , 240 volt, suitable for existing heat piller make gopi/ belco or equvilent complete all unit all as directed by Engineer-in-Charge .
Slim panel type wall mounting heater, less burning oxygen, eco friendly convection tech,240 volt 1000 watt complete with nut bolt clamp and hanging unit etc all as directed by Engineer-in-Charge .
Supply, fixing installing and testing ISI marked, metalic body, energy efficient , Storage water heater (five star rating) 50 liters capacity, cooper tank, AC 230 Volts,single phase, 50 Hz including wire armoured 450 mm long, 15 mm dia, brass coupler etc, flexible pipe suitable to withstand upto 1000 c for hot and cold water, anchor faster -04 nos of suitable size, 3 core PVC insulated, FRLS multistanded copper conductor cable and plug top of 15 Amp capacity, complete all as specified and directed.
Earth continuity conductor or main earthling lead of fixed to wall or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthling etc as required 4 mm dia galvanized iron or steel wire complete and all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of Voltage surge protector, 230/240 volts AC, 1.4 KV protection level type II with indicator doble pole (two modules) with rupturing cacpacity 40 KA including makeing connection and providing thimble for out going cables and enclosure complete and all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement outdoor intergal fantsy decorative LED bollard with IP protection 65 post top lantern suitable for landscap lighting in and including 08 watt LED with all complete fixing accessories and suitable arrangement as required at site complete and all as specified and as directed by Engineer-in-Charge.
Vijay Kumar Contractor and Engineers
m/S Varun Gupta
M/s. Rishav Sood
somyaenterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .