Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAccepted-AOC 49 PARAG DAS STREET SEUJI LAKSHMI PATH PANDU SADILAPUR KAMRUP M GUWAHATI 781012 ASSAM | KAMRUP METRO | ASSAM | 781012 | L1 | Accepted-AOC Being L1 bidder. | |
| 2 | L2₹32.7 L+₹1.3 L (4.00%)Rejected-AOC | L2 | Rejected-AOC Not being L1 bidder. | |
| 3 | L3₹33.6 L+₹2.2 L (7.02%)Rejected-AOC F A ROAD MACHKHOWA PO PS BHARALUMUKH DIST KAMRUP M ASSAM GUWAHATI 781009 | KAMRUP METRO | ASSAM | 781009 | L3 | Rejected-AOC Not being L1 bidder. | |
| 4 | L4₹34.0 L+₹2.5 L (8.03%)Rejected-AOC HOUSE NO 22 BHAGADUTTAPUR BELTOLA RUKMINIGAON ROAD GUWAHATI 781028 | KAMRUP METRO | ASSAM | 781028 | L4 | Rejected-AOC Not being L1 bidder. | |
| 5 | L5₹34.2 L+₹2.7 L (8.74%)Rejected-AOC | L5 | Rejected-AOC Not being L1 bidder. |
| Sl No | Description | Qty | Unit | M/S TRADE CENTRE L5 | MS DAS CONSTRUCTION L6 | M/S RAJA CONSTRUCTION L3 | Nripen Kalita L1 | M/S DAS CONSTRUCTION L2 | M/S B.H. ENTERPRISE L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches, not exceeding 1.50m wide and not exeeding 1.50m in depth for foundations, trenches of cable or pipe lines etc or and getting out in soft / loose soil complete all as specified and as directed. | 312 | Cum | 400 ₹1,24,800 | 430 ₹1,34,160 | 310 ₹96,720 | 295 ₹92,040 Lowest | 300 ₹93,600 | 405 ₹1,26,360 |
| 2.00 | All as per Sl Item No. 1.00 here-in-above but exeeding 1.5m in depth. | 0.19 | Cum | 652 ₹123.88 | 650 ₹123.5 Lowest | 750 ₹142.5 | 756 ₹143.64 | 770 ₹146.3 | 651.5 ₹123.79 |
| 3.00 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all specified and as directed. | 161 | Cum | 200 ₹32,200 | 198 ₹31,878 | 100 ₹16,100 Lowest | 137 ₹22,057 | 140 ₹22,540 | 201 ₹32,361 |
| 4.00 | Removing excavated materials (soil) to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point complete all as specified and directed. | 151 | Cum | 330 ₹49,830 | 329 ₹49,679 | 250 ₹37,750 | 145 ₹21,895 Lowest | 150 ₹22,650 | 325 ₹49,075 |
| 5.00 | M&L for sand cushioning with coarse sand in trenches for protection of underground electric cable, spread to uniform 23 cm thickness and punned down gently to 18 cm after spreading over the cable complete all as specified and directed. | 107 | Cum | 2,110 ₹2,25,770 | 2,200 ₹2,35,400 | 1,250 ₹1,33,750 Lowest | 1,310 ₹1,40,170 | 1,325 ₹1,41,775 | 2,150 ₹2,30,050 |
| 6.00 | Supply and laying well burnt sub class 'B' old size bricks, laid flat dry, in trenches with width of the bricks laid to the axis of cable for cable protection complete all as specified and as directed. | 10,720 | Each | 14 ₹1,50,080 | 15 ₹1,60,800 | 17.5 ₹1,87,600 | 9 ₹96,480 Lowest | 11 ₹1,17,920 | 12 ₹1,28,640 |
| 7.00 | Disconnecting electrical connections & taking out old unsv UG cable of any size & type. | 1,340 | RM | 37 ₹49,580 | 40 ₹53,600 | 50 ₹67,000 | 18 ₹24,120 | 15 ₹20,100 Lowest | 36.5 ₹48,910 |
| 8.00 | Supply, laying, jointing and testing XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with stranded aluminum conductor 1100 volts grade, laid in trenches/duct/on pole including all necessary fizing arrangement such as lugs, glands end termination etc. of cross sectional area 120 Sqmm x 3.5 core complete all as specified and as directed. | 120 | RM | 1,253 ₹1,50,360 | 1,300 ₹1,56,000 | 1,350 ₹1,62,000 | 1,249 ₹1,49,880 Lowest | 1,300 ₹1,56,000 | 1,255 ₹1,50,600 |
| 9.00 | All as per item No- 8.00 here in above but of size 150 Sqmm x 3.5 core. | 50 | RM | 1,382 ₹69,100 Lowest | 1,400 ₹70,000 | 1,400 ₹70,000 | 1,610 ₹80,500 | 1,550 ₹77,500 | 1,382 ₹69,100 Lowest |
| 10.00 | All as per item No- 8.00 here in above but of size 185 Sqmm x 3.5 core. | 70 | RM | 1,498 ₹1,04,860 Lowest | 1,610 ₹1,12,700 | 1,650 ₹1,15,500 | 2,010 ₹1,40,700 | 2,100 ₹1,47,000 | 1,565 ₹1,09,550 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
2 Mar 2026, 6:00 pmClosed
GE (P) AF Digaru
GE (P) AF Digaru PO Digaru Dist Kamrup Assam 782401
REPAIR/MAINTENANCE AGAINST DAY TO DAY COMPLAINTS OF LT UG CABLE, POLES, CABLE TERMINATIONS, JOINTING OF DIFFERENT SIZES CABLES AND DISTRIBUTION PANELS AND SERVICING OF SERVO VOLTAGE STABILIZER AND CONNECTED WORKS AT VARIOUS INSTALLATION AT AFS DIGARU
2026_MES_752276_1
C/8858/E8 of 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Digaru
Please ref Tender Documents
6 documents required · 6 mandatory
₹500
GE (P) AF Digaru
₹60,000
Yes
4 Apr 2026
11 Feb 2026
9 Mar 2026
11 Feb 2026
2 Mar 2026
18 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches, not exceeding 1.50m wide and not exeeding 1.50m in depth for foundations, trenches of cable or pipe lines etc or and getting out in soft / loose soil complete all as specified and as directed. | 312 | Cum | 100 | ₹31,200 |
| 2 | All as per Sl Item No. 1.00 here-in-above but exeeding 1.5m in depth. | 0.19 | Cum | 100 | ₹19 |
| 3 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all specified and as directed. | 161 | Cum | 10 | ₹1,610 |
| 4 | Removing excavated materials (soil) to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point complete all as specified and directed. | 151 | Cum | 11 | ₹1,661 |
| 5 | M&L for sand cushioning with coarse sand in trenches for protection of underground electric cable, spread to uniform 23 cm thickness and punned down gently to 18 cm after spreading over the cable complete all as specified and directed. | 107 | Cum | 100 | ₹10,700 |
| 6 | Supply and laying well burnt sub class 'B' old size bricks, laid flat dry, in trenches with width of the bricks laid to the axis of cable for cable protection complete all as specified and as directed. | 10,720 | Each | 10 | ₹1,07,200 |
| 7 | Disconnecting electrical connections & taking out old unsv UG cable of any size & type. | 1,340 | RM | 11 | ₹14,740 |
| 8 | Supply, laying, jointing and testing XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with stranded aluminum conductor 1100 volts grade, laid in trenches/duct/on pole including all necessary fizing arrangement such as lugs, glands end termination etc. of cross sectional area 120 Sqmm x 3.5 core complete all as specified and as directed. | 120 | RM | 100 | ₹12,000 |
| 9 | All as per item No- 8.00 here in above but of size 150 Sqmm x 3.5 core. | 50 | RM | 10 | ₹500 |
| 10 | All as per item No- 8.00 here in above but of size 185 Sqmm x 3.5 core. | 70 | RM | 11 | ₹770 |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
BOQ_842578.xls
BOQ • 0.51 MB
PS8858.pdf
Tender Documents • 1.00 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .