Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 CrAccepted-AOC | ₹8.7 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹10.9 Cr+₹2.2 Cr (25.8%)Rejected-Finance | ₹10.9 Cr+₹2.2 Cr (25.8%) | L2 | Rejected-Finance Not lowest |
| Sl No | Description | Qty | Unit | M/s T.K. ENTERPRISE L2 | M/S N T ENTERPRISES L1 |
|---|---|---|---|---|---|
| 0.00NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. | |||||
| 1.00SCHEDULE 'A' PART I DESIGN & BUILD STRUCTURE | |||||
| 1.10 | Design & Construction of Training Infrastructure to include 01 No.Indoor Badminton Court, 01 No. Indoor Basketball Court and 01 No Idoor Volley Ball Court (Single strorey), including Ground Floor Annexure and First Floor Annexure in RCC framed structure and MS roof trusses for Indoor Court and Pre-painted Galvalume sheet for roof, including excavation for foundation, plinth protection, ramp, entry platform and all fixture and fitting as shown on drawings and as per design criteria based on soil investigation report enclosed. Design shall include structural design of super struture, foundation and design of internal services with layout and drawings. Design of services shall be undertaken using items but not limited to as given in respective schedule. complete all as specified and as shown on drawings No. CESZ/SH/2025/AR-195 'A' Dt-07.07.25 & 04.09.25 Sheet No: 1R/6, 2R/6, 3/6, 4R/6, 5R/6 & 6/6 AND CESZ/SH/2025/AR-195 'B' Dt-07.07.25 Sheet No: 1/3,2/3 & 3R/3. | 1 | Lump-sum | 9,00,00,000 ₹9,00,00,000 | 7,70,11,111 ₹7,70,11,111 Lowest |
| 1.20Notes: The Following shall also forms part of Lump sum quoted by the bidders:- (i) M & L for preparing of finising concrete top rough surfaces by using brooms and finally fanning the cleaned surface with air blower to remove all loose dirt, dust and debris etc. (ii) Laying synthetic Acrylic flooring in 8 layers as given below (Make: As per approved list of Make) :- (a) Applying a coat of 0.2-0.3 mm thick pure acylic primer mixed with portable water at the ratio of 1:2 by using a roller or squeegee wiper at the rate of 700 to 900 gms/sqm to prevents delaminating and seals minor cracks and pores. Allow the primer to completely dry at least 2 hours before applying the resurfacer to ensure proper adhesion and durable finish. (b) laying two layers of 0.2-0.3 mm thick each acrylic resurfacer mixed with fine silica sand, cement and potable water in the ratio of 1:1:0.75:1.3 by using squeegee wiper at the rate of 350 to 550 gms/sqm for a layer to fill minor cracks and imperfections, improves surface uniformity, enhances durability and prepares the base for cushioning. Allow for a minimum of 24 hours of curing time under good drying conditions before allowing second layer and second layer should be applied at a 90º angle to the first (c) Laying two layers of 0.2-0.3 mm thick each acrylic cushion coating mixed with coarse rubber particles and potable water in the ratio of 1:0.25:0.75 by using a squeegee wiper at the rate of 600 to 750 gms/sqm for a layer to adds resilence and flexibility. Allow each layer to be dry at least 3 hours before allowing second layer and second layer should be applied at a 90º angle to the first. | |||||
| 1.30Notes: (Contd.../) (d) Laying final coat of 0.2-0.3 mm thick acrylic cushion coating mixed with fine rubber particles and portable water in the ratio of 1:0.25:0.75 by using a squeegee wiper at the rate of 600 to 750 gms/sqm to adds resilence and flexibility. (e) Laying two layers of 0.3-0.5 mm thick each acrylic colour mixed a squeegee wiper at the rate of 250 to 350 gms/sqm for a layer to provide high durability and excellent grip. Allow each layer to be dry at least 1 hour before allowing second layer and second layer should be applied at a 90º angle to the first. (f) Marking of the basket ball court, volleyball court and badminton court using acrylic line marking primer, after masking tape has been laid, to seal voids between masking tape and court surface to prevent bleed-under when line paint is applied then apply a minimum of 1 coat of acrylic line paint in accordance with manufacturer's instructions. (iii) S & F basketball pole movable height adjustable made of MS square pipe 6 inch and 10 feet long painted with acrylic paint and heavy trolley made of channel with 4 wheels including solid polycarbonate boards of size 180 cm x 105 cm x 25 mm with brackets, net and ring. (Quantity- 2 Each) (iv) S & F Badminton pole movable made of MS round pipe 1 inch and 5 feet long painted with acrylic paint and weight not less than 45 Kg per piece with net. (Quantity- 2 Each) (v) S & F volleyball pole movable made of MS round pipe 3 inch and 2.55 metre long with acrylic paint with 100 mm slider type, adjustable height of net and two wheels. (Quantity - 2 EAch). | |||||
| 1.40Notes: (Contd.../) (vi) S & F stainless steel changing bench seating of size 1000 mm in length, 450 mm in width and four legs of 325 mm in height each, the weight of the bench should not be less than 18 Kg each. (vii) Moveable MS lockers shall not be part of the scope of this contract. | |||||
| 2.00 | Lumpsum price worked out by the tenderer for SITE CLEARANCE, SITE DEVELOPMENTS & EARTH WORKS as listed in Schedule ‘A’ Part-II | 1 | Lump-sum | 7,00,000 ₹7,00,000 | 6,07,403.69 ₹6,07,403.69 Lowest |
| 3.00 | Lumpsum price worked out by the tenderer for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-III | 1 | Lump-sum | 13,00,000 ₹13,00,000 | 12,55,912.02 ₹12,55,912.02 Lowest |
| 4.00 | Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IV | 1 | Lump-sum | 1,20,000 ₹1,20,000 | 1,03,195.99 ₹1,03,195.99 Lowest |
| 5.00 | Lumpsum price worked out by the tenderer for ROAD/PATH/CULVERTS/HARD STANDING as listed in Schedule ‘A’ Part-V | 1 | Lump-sum | 27,99,999 ₹27,99,999 | 27,85,042.69 ₹27,85,042.69 Lowest |
Tender Value
Refer Docs
EMD Value
₹7.7 L
Closing Date
1 Nov 2025, 6:00 pmClosed
Cheif Engineer Shillong
Chief Engineer Shillong Shillong Zone Spread Eagle Falls Shillong 793011
PROVN OF TRAINING INFRASTRUCTURE TO INCLUDE COURTS FOR VOLLEYBALL, BADMINTON AND BASKETBALL COURT ETC AT ARC UNDER GE SHILLONG
2025_MES_721501_1
89822/SHL/E8
Open Tender
Civil Works
Lump-sum
540 days
GE Shillong
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,000
GE Shillong
₹7.7 L
Yes
1 Jan 2026
19 Jul 2025
3 Nov 2025
4 Aug 2025
1 Nov 2025
25 Oct 2025
Amount
NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
SCHEDULE 'A' PART I DESIGN & BUILD STRUCTURE
Design & Construction of Training Infrastructure to include 01 No.Indoor Badminton Court, 01 No. Indoor Basketball Court and 01 No Idoor Volley Ball Court (Single strorey), including Ground Floor Annexure and First Floor Annexure in RCC framed structure and MS roof trusses for Indoor Court and Pre-painted Galvalume sheet for roof, including excavation for foundation, plinth protection, ramp, entry platform and all fixture and fitting as shown on drawings and as per design criteria based on soil investigation report enclosed. Design shall include structural design of super struture, foundation and design of internal services with layout and drawings. Design of services shall be undertaken using items but not limited to as given in respective schedule. complete all as specified and as shown on drawings No. CESZ/SH/2025/AR-195 'A' Dt-07.07.25 & 04.09.25 Sheet No: 1R/6, 2R/6, 3/6, 4R/6, 5R/6 & 6/6 AND CESZ/SH/2025/AR-195 'B' Dt-07.07.25 Sheet No: 1/3,2/3 & 3R/3.
Notes: The Following shall also forms part of Lump sum quoted by the bidders:- (i) M & L for preparing of finising concrete top rough surfaces by using brooms and finally fanning the cleaned surface with air blower to remove all loose dirt, dust and debris etc. (ii) Laying synthetic Acrylic flooring in 8 layers as given below (Make: As per approved list of Make) :- (a) Applying a coat of 0.2-0.3 mm thick pure acylic primer mixed with portable water at the ratio of 1:2 by using a roller or squeegee wiper at the rate of 700 to 900 gms/sqm to prevents delaminating and seals minor cracks and pores. Allow the primer to completely dry at least 2 hours before applying the resurfacer to ensure proper adhesion and durable finish. (b) laying two layers of 0.2-0.3 mm thick each acrylic resurfacer mixed with fine silica sand, cement and potable water in the ratio of 1:1:0.75:1.3 by using squeegee wiper at the rate of 350 to 550 gms/sqm for a layer to fill minor cracks and imperfections, improves surface uniformity, enhances durability and prepares the base for cushioning. Allow for a minimum of 24 hours of curing time under good drying conditions before allowing second layer and second layer should be applied at a 90º angle to the first (c) Laying two layers of 0.2-0.3 mm thick each acrylic cushion coating mixed with coarse rubber particles and potable water in the ratio of 1:0.25:0.75 by using a squeegee wiper at the rate of 600 to 750 gms/sqm for a layer to adds resilence and flexibility. Allow each layer to be dry at least 3 hours before allowing second layer and second layer should be applied at a 90º angle to the first.
Notes: (Contd.../) (d) Laying final coat of 0.2-0.3 mm thick acrylic cushion coating mixed with fine rubber particles and portable water in the ratio of 1:0.25:0.75 by using a squeegee wiper at the rate of 600 to 750 gms/sqm to adds resilence and flexibility. (e) Laying two layers of 0.3-0.5 mm thick each acrylic colour mixed a squeegee wiper at the rate of 250 to 350 gms/sqm for a layer to provide high durability and excellent grip. Allow each layer to be dry at least 1 hour before allowing second layer and second layer should be applied at a 90º angle to the first. (f) Marking of the basket ball court, volleyball court and badminton court using acrylic line marking primer, after masking tape has been laid, to seal voids between masking tape and court surface to prevent bleed-under when line paint is applied then apply a minimum of 1 coat of acrylic line paint in accordance with manufacturer's instructions. (iii) S & F basketball pole movable height adjustable made of MS square pipe 6 inch and 10 feet long painted with acrylic paint and heavy trolley made of channel with 4 wheels including solid polycarbonate boards of size 180 cm x 105 cm x 25 mm with brackets, net and ring. (Quantity- 2 Each) (iv) S & F Badminton pole movable made of MS round pipe 1 inch and 5 feet long painted with acrylic paint and weight not less than 45 Kg per piece with net. (Quantity- 2 Each) (v) S & F volleyball pole movable made of MS round pipe 3 inch and 2.55 metre long with acrylic paint with 100 mm slider type, adjustable height of net and two wheels. (Quantity - 2 EAch).
Notes: (Contd.../) (vi) S & F stainless steel changing bench seating of size 1000 mm in length, 450 mm in width and four legs of 325 mm in height each, the weight of the bench should not be less than 18 Kg each. (vii) Moveable MS lockers shall not be part of the scope of this contract.
Lumpsum price worked out by the tenderer for SITE CLEARANCE, SITE DEVELOPMENTS & EARTH WORKS as listed in Schedule ‘A’ Part-II
Lumpsum price worked out by the tenderer for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-III
Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IV
Lumpsum price worked out by the tenderer for ROAD/PATH/CULVERTS/HARD STANDING as listed in Schedule ‘A’ Part-V
Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-VI
Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-VII
Lumpsum price worked out by the tenderer for DRAIN as listed in Schedule ‘A’ Part-VIII
SCHEDULE 'A' SEC-IX (MISCELLANEOUS ITEMS) NOTE: THIS SCHEDULE IS NOT PRE-PRICED BY MES AND THE PRE-PRICED RATE INDICATED AS "RS 0.00" UNDER COL. 5 SIGNIFIES THIS FACT ONLY.
Sewage disposal: M & L for DWCPE (SN8) 100 mm diameter pipes laid on 150 mm thick bed with excavation in any type of soil, including manholes/drop manhole of standard size made of Brick masonry/RCC Precast RCC with SFRC ventilating cover and frame. Includes all items and activities to execute and make sewer line functionnal. Note: As per IS 16098 (Part 2) : 2013 Para A-4 1.2.4(a) any form of cement concrete structural bedding would not be necessary under normal conditions, even for maximum combined loading (wheel load + backfill). However designer may check requirement for special cases, completes for depth up to 1.65 metre all as specified and as directed.
Sewage disposal: M & L for construction on site conventional RCC septic tank (150 users) designed to carry designed to carry sewage and sullage water, excavation in any type of soil, PCC (1:4:8) below foundation, Vent shaft, connection etc., connection etc., complete all as per Drawing No. CESZ/2020/STD-02, sheet 1/2 & 2/2.
Sewage disposal: M & L for construction of Soakage wells, excavation, in any type of soil, foundation in PCC (1:3:6) walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonry in cement mortar, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.6 M dia x 3.00 M depth, complete all as per drawing No. CESZ/2020/TD-45 Sheet 1/2 & 2/2.
S&F of Hot water storage (Geyser) 50 Ltrs capacity,BEE 5 star rated,vertical type,digital temperature display with suitable size of fastner and incl provision and connecting up of ss braided pipe with adopter for inlet and outlet water connection, copper element corrosion resistance antiscaling magnesium anode, having adjustable knob for temperature control and inner tank material of superior glassline coating / percelain Enamel Coating / Titanium Enamel Coating / Nano Blue Diamond Glass Coating / Coating with Single Weld line tank and outer body material ABS with high pressure with standing capacity upto 8 bar presuure, Multiple safety systems for protection against dry heating, overheating and over pressure,IPX4 waterproof technology for longer product life having heating element 2 KW and minimum two year warranty on product, minimum 3 years warranty on heating element 5 years on tank complete all as specified and directed.
S & F Modular blanking plate modular type suitable for fixing in modular switch board, complete all as specified and as directed.
S & F energy saving, environment friendly & robust Mediumbay LED luminaire 80 Watt with high efficacy 140 lm/w with toughned glass, mounting bracket suitable for mounting with truss complete all as specified and directed by Engr-in-charge.
S & F Surge Protection Device (SPD) Single Phase and neutral, T2 -limb, Imax 20 KA per pole complete fixed in distribution board and making connections complete all as specified and directed
S&F digital time switch 2 module, with Astronomical Function for swtching ON/OFF lights according to sun rising/ sun setting, with combination function for creating switching programs in which the devices are switched according to astronomical time and/ or fixed preset times, having daily astronomical calculation of the sunrise/sunset times based on the entered location or location coordinates complete having 2 output 16 Amps, 250 volts, 50 HZ, Astronomical function 2x28 programs 2 channel, 1 MCB SPN and 2 Nos MCB SP as out going for lighting circuit, complete accessories housed in a sheet metal enclosure dully painted with two coats of synthetic ennemelled paint over a one coat of red oxide primer complete all as specified and direcetd.
Supply , installation, testing and comission of Smart energy prepaid Meter confirming to IS-16444: 2015 (Reaffirmed 2020) and as ammended time to time, AC whole current, three phase, 4 wires Smart Energy Meter of rating 415 Volt, 10-100 Amps,50 Hz , Class 1, enclosed in polycarbonate box complete as specified in CEA notification. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I. The slection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meters should be based on RF Mesh communication technology or Cellular communication technology and carry min 5 yrs warranty.
Design, Supply, Installation, Testing and Commisioning of flickerfree, high performance, glare free, sports lighting LED system for Indoor Basketball court including all connected work as per DBR (given in Schedule 'A' BOQ Notes) specification and relavant standards complete all as specified and directed. NOTE: (i) DBs, RCBOs, SPDs, MCBs for sports lighting and submain wiring upto sports lighting DB not included in the scope of DBR. (ii) Location of Sports lighting DB shall be decided by contractor. (iii) Design of lighting system shall be approved by the Accepting Officer.
Design, Supply, Installation, Testing and Commisioning of flickerfree, high performance, glare free, sports lighting LED system for Indoor Volleyball court including all connected work as per DBR (given in Schedule 'A' BOQ Notes) specification and relavant standards complete all as specified and directed. NOTE: (i) DBs, RCBOs, SPDs, MCBs for sports lighting and submain wiring upto sports lighting DB not included in the scope of DBR. (ii) Location of Sports lighting DB shall be decided by contractor. (iii) Design of lighting system shall be approved by the Accepting Officer.
Design, Supply, Installation, Testing and Commisioning of flickerfree, high performance, glare free, sports lighting LED system for Indoor Badminton court including all connected work as per DBR (given in Schedule 'A' BOQ Notes) specification and relavant standards complete all as specified and directed. NOTE: (i) DBs, RCBOs, SPDs, MCBs for sports lighting and submain wiring upto sports lighting DB not included in the scope of DBR. (ii) Location of Sports lighting DB shall be decided by contractor. (iii) Design of lighting system shall be approved by the Accepting Officer.
Supply, fixing and testing DI fittings for spigot & socketed or flanged pipes i.e bends, reducers, tail pieces, tapers, tees, collars, caps, plugs with MS plate, nuts, bolts, washers gaskets etc., of sizes 50mm to 150 mm dia, complete all as specified and as directed.
Supply, install, test and commission LT FEEDER PANEL, TPN 415 Volts, 50 Hz, out door cubical type floor mounted factory made, double door dust and vermin proof IP-54, fabricated out of CRCA sheet not less than 2.0 mm thick with 2.0 mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out of 50x50x6 mm with cable chamber for individual feeders for incoming and outgoing connections, one set of LED indicator lamp RYB with switch and fuse and the panel board shall be provided with proper ventillation including suitable size of cable alley aluminium bus bar suitable for carrying of current 200 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN aluminium bus bars of suitable rating and connections from main bus bar to out going MCCB's (intake point) will be carried out with TPN aluminium bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 m height positioned and fixed with suitable nut, bolts, washers etc all as specified and directed comprising of the following:- (a) INCOMING (i) Thermal and magnetic release based MCCB FP 125 Amps 36 KA I/C - 01 No (ii) Phase indicator lamps (RYB) - 01 set (iii) 3Ph digital multi function meter model A, class 1, 5A with relay Vega Series - 1Nos (b) OUTGOING (i) Thermal Magnetic Released based MCCB FP 100Amps 36 KA - 01 Nos (ii) MCB TPN 20 Amps 10 KA - 01 Nos (C-Curve)
S & F epoxy powder coated sheet metal enclosure for Busbar chamber Box, Triple pole and neutral copper busbar of rating 100A, 415V, drilled for taking upto 4 Nos connection as outgoing including nut bolt of suitable size, embossed Earthing terminal, removable top and bottom gland plates with conduit knockouts with sufficient space for cable of different size complete all as specified and directed by Engr-in-charge.
Supply, installation, testing & commissioning of 10 KVA capacity DSC/micro controller based pure sinewave inverter with weatherproof enclosure and locking arrangement complete including electrical connection, compact design with improved efficiency and load handling, user friendly LCD display and control button using PWM technology with constant voltage & frequency output, easily by pass the device in case of Device fault and allow mains to be available without any wiring change, including 08 Nos of 12V, 200 Ah capacity sealed maintenance free battery 60 months warranty complete all as specified and directed.
Design, supply, installation, commisssioning & customization of digital score board. Model shall be in compliance with EN, DIN & shall be procured from SAI-approved vendors OEM shall ensure at least 5 year support and explicit multi-sport templates as per SAI formats/standards for basketball, volleyball, and badminton. Display system shall have preset sport modes, flexible data fields, branding/messages zones, multi-language, wireless, wireless control, and integration with shot clocks or PA systems. Make: as per approved list of Make.
Design, supply installation, testing & commissioning of wind driven turbo ventilators, 600-650 mm diameter, made from SS 304 grade or anodized aluminium, with sealed bearing/bearing less assembly, provided with rain guard, bird mesh, including ridge side positioning and waterproof UV resistant Polycarbonate/FRP/EPDM flashing base to match roofing profile, inclusive of all fasteners, supports, and sealants all as per DBR attached and manufacturer recommendations complete in all respects with 5 year warranty, complete unit must deliver ≥ 1,800 CFM at 3 m/s wind speed.
Providing and fixing wall mounted continuous fixed blade ventilation louvers (minimum free opening 20 m² in total), made from powder coated extruded aluminium profiles, horizontal blades fixed at 45º, with rain-dust hoods/drip protection, integrated SS 304 bird and mosquito mesh, and modular GI/AI frame, along designated side walls at 1.5-2 m AFFL, including all accessories and sealing of periphery for weather-tightness all as per DBR attached herewith.
Providing and installing lightning protection system for all ventilator banks on rooftop, including copper/aluminium air terminal, down conductor, earthing as per IS:2309 including supply, laying testing and commissioning, complete in all respects.
Provision and installation of maintenance access steel tubular ladder (IS 1161), 3 metre height, anti-corrosive painted, fixed to wall or structure at two points for safe access to ventilators for inspection/cleaning.
M/s T.K. ENTERPRISE (BID ID -3481032)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
Drawings.pdf
Additional Documents • 1.80 MB
Tender.pdf
Tender Documents • 18.05 MB
BOQ_807641.xls
BOQ • 0.48 MB
C89822SHL19E8.pdf
Tender Documents • 0.76 MB
BOQ.xls
BOQ • 0.48 MB
Tenderdocument.pdf
Tender Documents • 18.05 MB
Tenderdocument_2.pdf
Tender Documents • 1.80 MB
89822corrigendumNo9.pdf
PDF • 0.01 MB
89822corrigendumNo8.pdf
PDF • 0.01 MB
89822corrigendumNo7.pdf
PDF • 0.01 MB
89822corrigendumNo6.pdf
PDF • 0.01 MB
89822corrigendumNo5.pdf
PDF • 0.01 MB
89822corrigendumNo4.pdf
PDF • 0.01 MB
89822corrigendumNo3.pdf
PDF • 0.01 MB
89822corrigendumN02.pdf
PDF • 0.01 MB
89822corrigendumN01.pdf
PDF • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .