| 1 | L1₹22.0 LAccepted-Finance | L1 | Accepted-Finance Lowest one | |
| 2 | L2₹29.9 L+₹7.9 L (35.7%)Rejected-Finance B 101 SURAJ TOWER MIRA BHAYANDER ROAD OPP SAI PETROL PUMP MIRA ROAD EAST THANE 401107 | MIRA ROAD EAST | THANE | MAHARASHTRA | 401107 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹33.8 L+₹11.8 L (53.8%)Rejected-Finance 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹42.2 L+₹20.2 L (91.8%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L4 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
11 May 2022, 6:00 pmClosed
GE (NW) NOFRA
DR HOMI BHABHA ROAD NEW NAVY NAGAR COLABA MUMBAI-05
REPAIR ROUTINE MAINTENANCE OF FIRE FIGHTING SYSTEM OF OUTLAYING AREAS UNDER GE NW NOFRA COLABA MUMBAI
2022_MES_518460_1
8028
Open Tender
Miscellaneous Works
Item Rate
330 days
Mumbai
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE (NW) NOFRA
₹70,000
Yes
18 Aug 2022
16 Apr 2022
16 May 2022
16 Apr 2022
11 May 2022
29 Apr 2022
16 Apr 2022 - 28 Apr 2022
Amount
Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking of system etc. including replacement of unserviceable components/parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at GANGOTRI/ BHGIRTHI Building (G+15) comprising following:- (a) Twenty Zone Main Fire Alarm Control Panel with each zone battery charger and 230 V power units. (b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc. (c) All wiring & cable connections (d) Lead acid battery 12V/9AH Capacity. (e) 60HP Main Fire Hydrant Pump Servicing & Testing (02 Nos.). (f) Testing of Electrical control panel of Fire Fighting System Water Pumps. (g) Testing of Pressure switch & Pressure Guage. (h) Testing of all Sluice Valve, NRV & Air Release Valve. P.M.
Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking of system etc. including replacement of unserviceable components/parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at ADITI AHILIYA Building (G+12) comprising following:- (a) Twenty Zone Main Fire Alarm Control Panel with each zone battery charger and 230 V power units. (b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc. (c) All wiring & cable connections (d) Lead acid battery 12V/9AH Capacity. (e) 60HP Main Fire Hydrant Pump Servicing & Testing (02 Nos.). (f) Testing of Electrical control panel of Fire Fighting System Water Pumps. (g) Testing of Pressure switch & Pressure Guage. (h) Testing of all Sluice Valve, NRV & Air Release Valve. P.M.
Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking of system etc. including replacement of unserviceable components/parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at SASSON COMPLEX – Four Building(Akash, Chandra, Badal & Diwakar) (G+12) comprising following:- (a) Twenty Zone Main Fire Alarm Control Panel with each zone battery charger and 230 V power units. (b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc. (c) All wiring & cable connections (d) Lead acid battery 12V/9AH Capacity. (e) 60HP Main Fire Hydrant Pump Servicing & Testing (02 Nos.). (f) Testing of Electrical control panel of Fire Fighting System Water Pumps. (g) Testing of Pressure switch & Pressure Guage. (h) Testing of all Sluice Valve, NRV & Air Release Valve. P.M.
Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking of system etc. including replacement of unserviceable components/parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at BOAT POOL WORKSHOP Building (G+1) AND NT POOL comprising following:- (a) Twenty Zone Main Fire Alarm Control Panel with each zone battery charger and 230 V power units. (b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc. (c) All wiring & cable connections (d) Lead acid battery 12V/9AH Capacity. (e) 60HP Main Fire Hydrant Pump Servicing & Testing (02 Nos.). (f) Testing of Electrical control panel of Fire Fighting System Water Pumps. (g) Testing of Pressure switch & Pressure Guage. (h) Testing of all Sluice Valve, NRV & Air Release Valve. P.M.
Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking of system etc. including replacement of unserviceable components/parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at VANDANA /VISHAKHA (G+15) / VATSALA Building (G+12) comprising following:- (a) Twenty Zone Main Fire Alarm Control Panel with each zone battery charger and 230 V power units. (b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc. (c) All wiring & cable connections. (d) Lead acid battery 12V/9AH Capacity. (e) 60HP Main Fire Hydrant Pump Servicing & Testing (04Nos.). (f) 10HP Jockey Pump Servicing & Testing (02 No.). (g) Testing of Electrical control panel of Fire Fighting System Water Pumps. (h) Testing of Pressure switch & Pressure Guage. (i) Testing of all Sluice Valve, NRV & Air Release Valve. (j) testing of 60 HP DG fire hydrent pump - 01 No
Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking of system etc. including replacement of unserviceable components/parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at INS SHIKRA (ATC TOWER) Building (G+7), All Hangers and INS SHIKRA (Adm ) Building (G+7) / (New sailors Accn ) Building (G+7) and DSC bldg comprising following:- (a) Twenty Zone Main Fire Alarm Control Panel with each zone battery charger and 230 V power units. (b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc. (c) All wiring & cable connections (d) Lead acid battery 12V/9AH Capacity. (e) 60HP Main Fire Hydrant Pump Servicing & Testing (02 Nos.). (f) Testing of Electrical control panel of Fire Fighting System Water Pumps. (g) Testing of Pressure switch & Pressure Guage. (h) Testing of all Sluice Valve, NRV & Air Release Valve. P.M.
Supply and fixing transformer AC/DC for fire alarm system panel of electronic type
Supply and fixing battery duly charged 12 V, 7.2 AH. Make: EXIDE or as per exixting make at site
Supply and fixing Zone cards. Make : HITESH or as per exixting make at site
Supply and fixing power cards. Make : HITESH
Replacement of manual call point suitable for addressable system duly painted in red colour paint with front glass (to be broken in case of fire ) complete with test key to check the response with out breaking the glass and die cast aluminum housing with IFD indicator all as specified. Make:- GURUTRONIC / HARDIK ENGINEERS
Supply and fixing electronic hooters. Make : GURUTRONIC / HARDIK ENGINEERS
Supply and fixing Addressable type Smoke / Heat detector. Make : APOLLO / MORLEY
Supply and fixing hydrant valve wheel complete incl all necessary fixtures and fittings as reqd.
Supply and fixing hydrant gun metal female coupling at site as directed
Supply and fixing rubber hose drum adopter connection (shank reducer) at site as directed
Supply and fixing brass lock pin (lugs) for 63 mm dia at site as directed
Supply and fixing hydrant valve spindle at site as directed
Supply and fixing rubber hose pipe 20mm dia, plain 2 ply rayon braided high pressure. Make : DEEP JYOTI / DUNLOP
Supply only Aluminium nozzle suitable for 20 mm dia rubber hose pipe.
Supply and fixing 100 mm sluice valve wheel.
Supply and fixing brass hydrant valve nut as per existing size.
Supply and fixing blank flange of size 100mm made out of MS 12 mm thick including flange joint.
Supply and fixing PVC blank cap of hydrants with GI chain.
Supply & Fix Factory fabricated MS fire cabinet box as per give design made out flat CRCA of appropriate size and thickness all as directed including two coat of powder coated approved colour synthetic enamel paint over a coat of red oxide primer & fixed on wall with necessary nuts/bolts or welding to existing MS pipe by supporting angle complete all as specified & directed by Engineer-in-Charge.
Supply and fixing canvas fire hose 63mm dia bore 30metre long confirming to IS Having male/female brass coupling both end complete all as specified.
Supply only brass Nozzle 25 mm bore suitable for 63mm dia canvas pipe complete all as specified.
Excavation in trenches n.ex.c 1.5 meter wide and n.exc 1.5 meter in depth for foundation etc for shafts, wells, cesspits,manholes,pier holes, etc n.exc 1.5min depth and getting out in hard/dense soil.
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level n.exc 1.5m above the starting point.
Returning, filling is including spreading, leveling, watering and well ramming in layers n.exc. 25cms(Soil).
Cutting out concrete blocks, slabs, brickwork or stone masonry(in alternate course) forming toothings for and bonding new work in mortar into old work, including new materials entering old wall.
Taking down existing double acting valve of size 100 x 65mm for servicing including replacement of unserviceable spares ie gland, nut, bolt, lock pin, CI hand wheel with chain, etc complete and re-fixing in position in high rise bldg not exceeding 15 stories.
Supply & Fix Gun metal double acting fire hydrant valve of size 100 x 65mm conforming to IS – 5290/71 with all fitments such as cap cover instantaneous coupler for making flanged joint 100mm dia bore.
Repairing to MS front door of size not exceeding 1.5 mtr x 1.5mtr including welding locking arrangement including providing pad lock 50mm (Make : GODREJ/NAVTAL) all as specified and as directed.
Preparing old painted surface of CI/MS pipe 100mm dia and applying two coats of synthetic enamel paint (Red colour) including a coat or red oxide primer”
Servicing of hose reel drums by applying greasing, oiling etc and making free rotation to hose drum all as specified and directed all as specified.
Removing old paint by paint removers and cleaning with scrappers, any number of coats, steel surfaces of any description over applying two coats of synthetic enameled paint over a coat of red oxide primer on fire valve pit / fire fighting cubical box fitted inside bldg on each floor.
Supply and replacement, installation, testing & commissioning of Micro processor based 2 wire fault tolerant loop, required loop networkable type 5 Loop (each loop accessing maximum 99 detectors and 99 modules ) fire alarm/detection control panel. The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFF respective control module whenever any alarm is triggered. The panel shall have rectifier, Loop cards, 80 character L C D unit to indicate Fire/Fault Signal with address and analog output. The Panel shall support 24 zones Addressable 2 way Talk Back fire fighter communication, in case of emergency. The panel shall have ability to get integrated with PA System for zone wise annoucements. The panel shall support both Loop Powered & conventional Notification devices for emergency responses. the Panel shall support Auto learn feature. The panel should support networking upto 99 panels with maximum distance of 12 Km between 1 & last & 1.5 KM between adjacent panels on RS485. Tha Panel shall support IP connectivity if requred to connect on LAN or WAN network. the panel shall support BMS connectivity through Bacnet/Modbus moduels. The Panel Shallbe Sheet Steel Painted, selaed to IP30. The Panel Shall have 24 Zones with Individual LEd Indicators, expandable to 80 LED Indicators. The Panel Shall have 3 Serial Ports. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 48 hours with battery charger complete as required.and as per specifications. conforming to BS5839 Standards and Duly Approved by EN54/ LPCB/ VDS/ UL/BSA complete all as specified and directed by Engineer-in-Charge, Voice Alarm controller with USB, MP3, AM/FM player )with 1000 watts Power Amplifier. Make :- Cease fire / Apollo / Hardik Engineer / Gurutronic
Supply & Fix in replacement MS pipes 100mm dia conforming to IS 1239 (Part-I) medium grade with both ends flanged and drilled with standard MS fitting including 02 coats of synthetic enamel painting over one coat of red oxide primer in any length and fixed on walls, complete all as specified and directed in high rise buildings Note : MS flanges including welding to MS pipes and all flanged joints shall be measured and paid separately under respective item of Sch ‘A’
Supply & Fixing MS flanges duly drilled including welding to 100/150 mm dia MS pipes complete all as specified and directed by Engr - in- charge
Material & Labour for flanged joints for 100mm/150 mm bore pipe at any location and position complete all as specified and directed by Engr - in- charge .
Supply and fixing Gun metal fire hydrant single acting of size 80 x 63mm for stand post.
Supply & Fix in repairs sluice valve, 100 mm size, both ends flayed with high tensile brass spindle,cast iron body, as per IS-14826 & ISI Marked,PN-1.6 pressure rating including all joints with rubber or fibre board, nuts, bolts, washers etc complete all as specified, Make:Sant / KIRLOSKAR
S&F Non return valve, ball type, conforming to IS, Model B-05, of size 100mm. (Make : Kirloskar/Normex)
Rewinding of electrical induction motor uo to 15HP capacity 3 phase 415 V of terrace booster pump of high rise bldg, including rewinding of the motor by proper gauge of copper wire with class E insulation with Varnishing, heating and re-assembling and testing at the site.
Rewinding of electrical induction motor uo to 40/ 60HP capacity 3 phase 415 V of terrace booster pump of high rise bldg, including rewinding of the motor by proper gauge of copper wire with class E insulation with Varnishing, heating and re-assembling and testing at the site.
Repair of 40/ 60HP pump and disconnecting the electric connection from motor terminal box including insulating the ends of the cable, taking out the pump set of any make from pump houses after opening nuts/bolts, transporting from site to workshop, dismantling pump, removing worn out impeller, ball bearing, gasket, assembling the pump with replacement of pulley, gland packing, greasing, transporting back to pump house and refixing on the existing foundation, connecting the electrilc connection to the motror and testing complete to entire satisfaction of Engineer-in-Charge .
Repair/maintenance of booster pump capacity upto 15 HP including necessary replacement of shaft impeller, bearings gun metal bush and coupling etc.
Supply and fixing in Replacement of electrical motors star delta starter fully automatic of capacity upto 05 HP
Supply and fixing in Replacement of electrical motors star delta starter fully automatic of capacity 60 HP
Supply and fixing in Replacement of star delta starter of capacity MNX 80 suitable for 40/60 HP motor.. Make : L & T / Havells /CG
Supply and fix in repairs FOOT valve, 150 mm size PN-1.6 pressure rating including all joints with rubber or fibre board, bolts, nuts washers, etc. complete all as specified “ Make:- (Kirloskar/Normex/Leader)
Supply and fix in repairs FOOT valve, 100 mm size PN-1.6 pressure rating including all joints with rubber or fibre board, bolts, nuts washers, etc. complete all as specified “ Make:- (Kirloskar/Normex/Leader)
Supply and fixing and takin out U/S cable of 1.5 Sqmm x 6 Core Copper Armored Cable. Make:Polycab
Supply and fix in replacement of rusted and broken cast iron lid and angle iron including locking arrangements/net fixed on RCC fire water tank as in repair suitable for up to 10000 gallons capacity
Cleaning and painting external surface with cement based paint complete, colour as existing Semi under ground RCC sump of cap 01 lakh to 02 lakh ltrs after draining out scraping out bottom and side of wall with wire brush and bleaching powder, removing scaling fungus, flushing thoroughly with clean water, applying on coat of white washing after drying inside, writing of tank capacity and date of cleaning and due date of cleaning in capital letters of 20mm size on external surface of wall with white enamel paint over black paint surface all as directed by Engr-in-Charge
PCC 1:3:6 type C2 (using 20 mm graded crushed stone aggregate) for plingth protection of semi under tank and PCC on fire water tank all as directed by Engineer-in-Charge.
Repair broken valve pit chamber of any size using sub class "B" brick masonry in cement mortar cm 1:4 including plastering internally and painted flush externally as the work proceeds and PCC 1:2:4 type B-1 as in copping and welding work with angle iron frame 40 mm x 40 mm x 6 mm with 2 mm thick MS sheet cover two side open with 2 Nos hinges each side and 2 Nos lifting handle and in built locking arrangement including lock and key and surface with two coats of synthetic paint and a coats of red oxide paint on steel surface including necessary excavation in any type of soil, earth work in any type of soil all as specified and directed.
Repair to unsewrviceable sluice valve of size 150/100 mm dia. Opening the nut,bolts both side flanged ,after taking down unscrew the top cover and taking out the spendle , gate with chucknut. Repair the unserviceable spindle and re-threading, spndle ,and refix the new chuckunt as per spindle size. After repair the suice valve refix the its position and testing all as directed by EIC
Supply and replacing the Gate chucknut of size 150/100 mm diasluice valve
Supply and fixing in replacement chequered plate 6 mm thick and cut to cable duct size & shape machined properly on sides and provide for cable duct protection.
Supply and fixing in replacement equal 45 x 45 mm angle iron 4 mm thick and cut to cable duct frame as per directed by Engr - in -charge
Disconnect electric connection and taking out existing service cable from the cable duct and cleaning sand /mud /other items after cleaning reconnect the service cable and checking electric supply in each Qtrs as per directed by Engr - in -charge
Supply and laying MS tubing 150 mm dia medium grade with all fitting such as tee, socket, bend, union etc in trenches complete.
S&F in replacement of unserviceable with new non return valve of CI body 100 m to 150 mm bore flanged with rubber packing including nuts bolts and wahsers etc complete as directed by EIC
Taking down the broken iron coupling from the 40 HP to 60HP motor / pump and fixing the new coupling with cotter pin, rubber piece and nut bolts.
Supply and replacement single core copper conductor cable PVC insulated of size 35 sqmm , 1100 volt conforming to IS 694/1990 and privide PVC pipe for protection of cable
Supply and fixing in replacemet of beam detectors for hangers directedn byn Engt -in-Charge. Make : APOLLO / MORLEY
Supply and fixing in replacement tyco fire sprinkler fixing in ceiling mounted as per sample and directed by Engr-in-charge
Taking down old unserviceable pressure gauge with the help of gas cutter/ monkey packed and in replacementy new Pressure gauge 100 mm dia with ball valve of pressure 25 Kg/Sqcm directed by Engr-in-Charge.
Taking down old unserviceable air release valve from the pump and supply and fixing brass air release valve as per sample as directed by Engr-in-Charge.
Saviour Security Systems
ASHOK ENTERPRISES
Shree Ayyappa Engineering
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .